Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.5 LAccepted-AOC S NO 50 8 MAMTA SOCIETY VADGAONSHERI BEHIND AYYAPPA TEMPLE PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹89.1 L+₹62,340 (0.70%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Bidder not quoted L1 rates | |
| 3 | L3₹91.7 L+₹3.3 L (3.71%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Bidder not quoted L1 rates | |
| 4 | L4₹94.6 L+₹6.1 L (6.91%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L4 | Rejected-Finance Bidder not quoted L1 rates | |
| 5 | L5₹99.8 L+₹11.4 L (12.9%)Rejected-Finance | L5 | Rejected-Finance Bidder not quoted L1 rates |
| Sl No | Description | Qty | Unit | PARAMOUNT ELECTRICALS L1 | Vijaypower Generators Limited L7 | AIRCON SYSTEMS L5 | Shree Ayyappa Engineering L2 | M/S. Niksun Electro-Infra Private Limited L3 | Prasur Electricals & Engineering Co. L8 | Leo Enterprises L6 | SBS Enterprises L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply Installation, testing and commissioning of 2500A Aluminium sandwich type 3P4W 100% N and 50% internal earth busbar other than housing, operating voltage 415V, Insulation voltage 1000 V rated short time current 80kA for 1Sec IP54, Mechanical strength IK10 protection. Bus duct shall be seismic zone-5 certified. the bus duct shall be type tested at a reputed test laboratory (Certified by CPRI/ ASTA/ ERDA or any NABL accrediated lab) for the tests as per IEC- 61439 Part-1 (Low voltage switchgear & control gear assembly -General rules) & Part 6 (Bus bar trunking systems & bus ways); The rated current of busbar trunking systems is always rated at the average ambient temperature of 40 degree C, Enclosure shall be of 1.6 mm GI. Insulation material used shall be of Polyethylene Terephthalate (PET) of class F (155 degree) UL certified, ROHS compliant. the conductors shall be made from an aluminium and tin plated at joints, provided with a monoblock pre-installed at the factory at one end. It shall ensure the IP55 degree of protection at the end of the run. All insulating plastic componenets shall comply with the incandescent wire test and have the standard degree of protection i.e IP 55 without using additional IP protection kits. the whole busbar is resistant to flame propagation and building penetration as per IEC in compliance with standard 61439-6. Complete all as specified and directed.
Make:- L&T/ABB/Siemens. | 150 | RM | 36,000 ₹54,00,000 Lowest | 51,500 ₹77,25,000 | 37,000 ₹55,50,000 | 38,486 ₹57,72,900 | 40,500 ₹60,75,000 | 53,775 ₹80,66,250 | 43,960 ₹65,94,000 | 45,000 ₹67,50,000 |
| 1.01NOTE for Ser. Item No. 1.00 above :- (i) Cost of any material and labour required for fixing of new bus bar in homogeneous with the existing old trunking bus bar is deemed to be included in the quoted rate. (ii) All safety measures required for the work shall be adopted as per manufacturers direction during execution. (iii) Any minor spare/work technically required for proper operation of system but missed out above is deemed to be included in the quoted rate. (iv) For any addition/alteration for completion of job required at site will be done at no extra cost. (v) A factory visit to be conducted during manufacturing of BBT. (vi) The Contractor shall submit all the related Test Reports on Completion of Work. (vii) The Testing & Commissioning of the entire system as per OEM Instructions shall be carried out in presence of OEM. Signed MOU with OEM shall submitted by the Contractor. (viii) Before connection into HVAC Panel all the switch gears (ACB) shall be tested and necessary servicing / repair work shall be carried out at No extra cost. | |||||||||||
| 2.00 | Supply Installation Testing Commissioning of Flange end of Busduct wherever required, complete all as specified and as directed. | 2 | EACH | 40,000 ₹80,000 | 65,000 ₹1,30,000 | 35,000 ₹70,000 | 1,67,503 ₹3,35,006 | 33,000 ₹66,000 | 49,999 ₹99,998 | 36,900 ₹73,800 | 15,500 ₹31,000 Lowest |
| 3.00 | Supply Installation Testing Commissioning of Horizontal Bend/Vertical Bend of Busduct wherever required, complete all as specified and as directed. | 18 | EACH | 30,000 ₹5,40,000 | 39,702 ₹7,14,636 | 28,000 ₹5,04,000 | 35,418 ₹6,37,524 | 17,000 ₹3,06,000 | 18,499 ₹3,32,982 | 11,900 ₹2,14,200 | 7,500 ₹1,35,000 Lowest |
| 4.00 | Supply Installation Testing Commissioning of Horizontal Fixing Clips (2 Nos per Horizontal Channel supports), complete all as specified and as directed. | 200 | SET | 250 ₹50,000 | 999 ₹1,99,800 | 200 ₹40,000 | 203 ₹40,600 | 200 ₹40,000 | 1,149 ₹2,29,800 | 55 ₹11,000 Lowest | 1,500 ₹3,00,000 |
| 5.00 | Supply Installation Testing Commissioning of Expansion joint panel (fabrication), complete all as specified and as directed. | 1 | SET | 2,00,000 ₹2,00,000 | 1,80,000 ₹1,80,000 | 3,00,000 ₹3,00,000 | 2,73,102 ₹2,73,102 | 2,40,000 ₹2,40,000 | 2,85,000 ₹2,85,000 | 1,93,000 ₹1,93,000 | 68,500 ₹68,500 Lowest |
| 6.00 | Supply Installation Testing Commissioning of Horizontal Channel with Clamp, complete all as specified and as directed. | 1 | SET | 500 ₹500 | 1,000 ₹1,000 | 300 ₹300 Lowest | 3,347 ₹3,347 | 2,570 ₹2,570 | 1,39,950 ₹1,39,950 | 400 ₹400 | 10,000 ₹10,000 |
| 7.00 | Supply Installation Testing Commissioning of Copper flexible, complete all as specified and as directed. | 2 | SET | 1,50,000 ₹3,00,000 | 75,000 ₹1,50,000 Lowest | 1,15,000 ₹2,30,000 | 86,105 ₹1,72,210 | 1,02,000 ₹2,04,000 | 1,72,500 ₹3,45,000 | 1,35,000 ₹2,70,000 | 2,05,000 ₹4,10,000 |
| 8.00 | Supply Installation Testing Commissioning of Threaded Rod (1.5m Length , Dia 16 mm ) with anchor Fastener, complete all as specified and as directed. | 300 | SET | 2,000 ₹6,00,000 | 501 ₹1,50,300 Lowest | 2,500 ₹7,50,000 | 502 ₹1,50,600 | 2,600 ₹7,80,000 | 849 ₹2,54,700 | 2,500 ₹7,50,000 | 800 ₹2,40,000 |
| 9.00 | Supply Installation Testing Commissioning of MS Structure supports for Indoor or outdoor application,complete all as specified and as directed. | 3,000 | KG | 175 ₹5,25,000 | 125 ₹3,75,000 | 180 ₹5,40,000 | 251 ₹7,53,000 | 120 ₹3,60,000 | 149 ₹4,47,000 | 150 ₹4,50,000 | 100 ₹3,00,000 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
29 Jan 2026, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE - 01
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85965 PROVN OF STANDBY SUPPLY THROUGH BUSBAR TRUNKING SYSTEM AND ALLIED WORKS AT AC PLANT IN NEW COMMAND HOSPITAL (SC) UNDER GE (SOUTH) PUNE
2025_MES_741810_2
85965 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (SOUTH) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (SOUTH)
₹1.9 L
Yes
11 Mar 2026
16 Jan 2026
31 Jan 2026
16 Jan 2026
29 Jan 2026
24 Jan 2026
Supply Installation, testing and commissioning of 2500A Aluminium sandwich type 3P4W 100% N and 50% internal earth busbar other than housing, operating voltage 415V, Insulation voltage 1000 V rated short time current 80kA for 1Sec IP54, Mechanical strength IK10 protection. Bus duct shall be seismic zone-5 certified. the bus duct shall be type tested at a reputed test laboratory (Certified by CPRI/ ASTA/ ERDA or any NABL accrediated lab) for the tests as per IEC- 61439 Part-1 (Low voltage switchgear & control gear assembly -General rules) & Part 6 (Bus bar trunking systems & bus ways); The rated current of busbar trunking systems is always rated at the average ambient temperature of 40 degree C, Enclosure shall be of 1.6 mm GI. Insulation material used shall be of Polyethylene Terephthalate (PET) of class F (155 degree) UL certified, ROHS compliant. the conductors shall be made from an aluminium and tin plated at joints, provided with a monoblock pre-installed at the factory at one end. It shall ensure the IP55 degree of protection at the end of the run. All insulating plastic componenets shall comply with the incandescent wire test and have the standard degree of protection i.e IP 55 without using additional IP protection kits. the whole busbar is resistant to flame propagation and building penetration as per IEC in compliance with standard 61439-6. Complete all as specified and directed. Make:- L&T/ABB/Siemens.
NOTE for Ser. Item No. 1.00 above :- (i) Cost of any material and labour required for fixing of new bus bar in homogeneous with the existing old trunking bus bar is deemed to be included in the quoted rate. (ii) All safety measures required for the work shall be adopted as per manufacturers direction during execution. (iii) Any minor spare/work technically required for proper operation of system but missed out above is deemed to be included in the quoted rate. (iv) For any addition/alteration for completion of job required at site will be done at no extra cost. (v) A factory visit to be conducted during manufacturing of BBT. (vi) The Contractor shall submit all the related Test Reports on Completion of Work. (vii) The Testing & Commissioning of the entire system as per OEM Instructions shall be carried out in presence of OEM. Signed MOU with OEM shall submitted by the Contractor. (viii) Before connection into HVAC Panel all the switch gears (ACB) shall be tested and necessary servicing / repair work shall be carried out at No extra cost.
Supply Installation Testing Commissioning of Flange end of Busduct wherever required, complete all as specified and as directed.
Supply Installation Testing Commissioning of Horizontal Bend/Vertical Bend of Busduct wherever required, complete all as specified and as directed.
Supply Installation Testing Commissioning of Horizontal Fixing Clips (2 Nos per Horizontal Channel supports), complete all as specified and as directed.
Supply Installation Testing Commissioning of Expansion joint panel (fabrication), complete all as specified and as directed.
Supply Installation Testing Commissioning of Horizontal Channel with Clamp, complete all as specified and as directed.
Supply Installation Testing Commissioning of Copper flexible, complete all as specified and as directed.
Supply Installation Testing Commissioning of Threaded Rod (1.5m Length , Dia 16 mm ) with anchor Fastener, complete all as specified and as directed.
Supply Installation Testing Commissioning of MS Structure supports for Indoor or outdoor application,complete all as specified and as directed.
Design, manufacture, test including Supply, unloading, fixing, testing and commissioning of LT Panel, (415 V) panel cubicle, indoor type, IP 48 degree of protection fabricated out of 2mm thick CRCA Sheet, (as per IS 8623) made to shape, for housing bus bar chamber, incomer, outgoing, etc. powder coated by means of electrostatic gun after rigorous minimum seven tank treatment after due preparation of surfaces,manufactured by CPRI approved manufacturer, free standing, floor mounted, dust and vermin proof. The panel shall be provided with separate compartments for each switchgear etc. with double stud hinged door,front openable with locking arrangement ,suitable for 1100 Volts grade, 3 phase, 415 Volts, 50 hz, AC supply, suitable to withstand short circuit fault level of 75 kA. In the panel all connections shall be through Busbar except for control wiring. Earth bus shall be part of the L.T panel). The incomer supply for the panel will be provided by the means of busduct and the supply will be taken from the existing LT -2 panel and the cost of necessary arrangement for the same as per site requirement is deemed to be included in the quoted rate. The panel shall be comprising of the following :-
A. Bus Bar (a) 4000 Amps, TPN aluminium bus bars of suitable length and suitable cross section. (b) Bus bars shall be insulated by heat shrinkable sleeves and clip on shrounds for joints. Bus Bar shall be designed to with stand a fault level of 75 kA at 415 Volts.
B. Incomer (a) The incomer feeder shall be provided with Digital Ammeter , CT's,Three number Phase indicating lamp as required. (b) 1 No's, 2500 Amps, 75 kA rating manually operated, Four pole, ACB of horizontal drawout pattern, for bus bar connection on incoming side and bus duct connection on outgoing side. The breakers shall be provided with Thermal Magnetic based releases.
C. Outgoing (a) The outgoing feeder shall be provided with Digital Ammeter, CT's,Three number Phase indicating lamp as required. (b) 1 No's, 2500 Amps, 60 kArating manually operated, Four pole, ACB of horizontal drawout pattern, for bus bar connection on incoming side and bus duct connection on outgoing side. The breakers shall be provided with Thermal Magnetic based releases.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.47 MB
BOQ_838698.xls
BOQ • 0.29 MB
85965TenderDocsNEW.pdf
Tender Documents • 5.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .