Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 CrAccepted-AOC NATIONAL TOWER 5TH FLOOR SCO 89 DSC RANJIT AVENUE AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹17.6 Cr Quoted ₹17.8 Cr | L1 | Accepted-AOC Being lowest. |
| 2 | L2₹18.6 CrRejected-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹18.6 Cr | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹18.8 CrRejected-Finance | ₹18.8 Cr | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹19.2 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹19.2 Cr | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹20.7 CrRejected-Finance | ₹20.7 Cr | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹19.7 Cr
EMD Value
₹13.1 L
Closing Date
6 Jun 2024, 6:00 pmClosed
CE Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt
AUGMENTATION OF FIRE FIGHTING SYSTEM OF MAIN HOSPITAL BLDG BLDG NO. P100 AT AHRR UNDER PARA 36 OF DWP 2020 UNDER GE EM RR HOSP DELHI CANTT-10
2024_MES_651057_1
CEDZ/TOKEN-24 OF 2023
Open Tender
Civil Works
308 days
Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹3,000
GE EM RR Hospital
₹13.1 L
Yes
18 Sept 2024
16 May 2024
8 Jun 2024
16 May 2024
6 Jun 2024
23 May 2024
16 May 2024 - 23 May 2024
Amount
Supply, installation & testing , yard hydrant valve made of stainless steel, ISI marked, 75mm NB flange inlet, single way outlet type with hose coupling adaptor of 63 mm size, instantaneous spring lock arrangement and blank cap with chain, conforming to IS 5290, type 'A', suitable for hydraulic pressure of 21 kgf/cm2 incl MS pipe line of size 80 mm upto 1.5 mtr height incl MS flanged both ends making all connection for smooth functioning complete all as directed.
Supply, installation, testing of oblique type hydrant valve made of stainless steel, ISI marked, 75mm NB flange inlet, single way outlet type with hose coupling adaptor of 63 mm size, instantaneous spring lock arrangement and blank cap with chain, conforming to IS 5290, type 'A', suitable for hydraulic pressure of 21 kgf/cm2 complete all as directed.
S&F hose box made of 18 gauge MS sheet 800mmx600mmx250mm with double door locking arrangement in front with 4mm thick glass and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside making good surface and making arrangement for 2 hose pipe inside the box incl 65 mm pad lock complete all as specified.
S&F Reinforced rubber lined fire hose pipe as per IS 636, type 'A', ISI marked, 63 mm nominal internal dia, 15 M long each, duly fitted with stainless steel coupling of 63 mm size, ISI marked with multi serrated tail and double instantaneous spring lock arrangement comprising of male half at one end and female half at other end complete with rubber cup washer and conforming to IS 903, suitable for hydraulic pressure of 21 kgf/cm2, complete all as directed.
S&F short branch pipe nozzle, made of gun metal, ISI marked, instantaneous pattern type to suit fire hose delivery coupling of 63 mm size complete with stainless steel nozzle of 15 mm nominal size conforming to IS 903, suitable for hydraulic pressure of 21 kgf/cm2, complete all as directed.
Supply and fix first aid hose reel with drum of 20 mm dia and 30 mtr length including branch nozzle conforming to IS-884 complete all as directed.
Providing and fixing fire hose cabinet of size 900 x 600 x 300mm weather proof fabricated from 18 SWG MS sheet with double front central opening partially glazed with 4mm thick glass with locking arrangement duly painted suitable to house incl 2x30Mtr (two length) of RRL house and hose reel drum with coupling, Branch pipe one firemans axe, first aid hose reel and hydrant outlet complete all as directed.
Supply and fix fire brigade valve connection 2 way incl MS pipe line of 80 mm size upto 1.5 mtr fsize making all connection for smooth functioning complete all as directed.
Supply and fix pressure gauge 100 mm dia ball valve of pressure 0 to 21 Kg/Sqcm complete all as directed.
S&F stop valves , cast copper alloy, screwed down , high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed suitable for 25 mm bore complete all as directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 metre wide for laying of pipes in trenches and getting out, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, after laying of pipeline complete all as specified & directed.
Removing excavated surplus material to a distance not exceeding 50 metres and depositing where directed, at a level not exceeding 1.5 metre above the starting point, complete all as specified & directed.
M&L for road cutting for laying of MS pipe, incl excavation, returning filling in, spreading, levelling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix capeting 25mm thick using ready mix patch repair work, complete all as specified & directed.
Taking down MS pipe of any size incl all fittings all as specified and directed.
Supplying, installation, testing and commissioning of electrically driven high pressure centrifugal fire hydrant pump suitable for automatic operation comprising of the following: (a) Horizontal end suction centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase 50 Hz AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced ) and stainless steel shaft with mechanical seal, capable for delivering 2280 LPM at outlet head of 70m and coforming to IS-12469 : 1988. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65 % of the rated head (b) Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply, for the above pump with synchronous speed of 1450 RPM, conforming to IP 55 protection & class F insulation. (c) Common base plate for (a) and (b) of MS (d) Suitable cement concrete foundation duly plastered with anti vibration pad complete as required.
Supplying, installing and commissioning C.I.flanged "Y" type Strainer 200 mm dia with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete.
Supply and fixing cast iron sluice valve of size 200 mm bore class PN10 conforming to IS-14846 flanged ends drilled having stainless spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets complete all as specified.
Supply and fixing of Butter Fly Valves (Manual) with CI body, Stainless steel disc, nitrile rubber seal & O ring, PN 16(16 bar) Pressure rating for chilled water circulation of following size, all as specified and directed.
Supply and fixing Non return valve of following size with dual plate of CI body, Stainless steel plates, vulcanised NBR seal flanged ends and PN 16(16 bar) Pressure rating, all as specified and directed of following size
Supply and fixing alarm check valve assembly/(ICV) 100 mm dia fitted with motor alarm, isolation valve and necessary gauges complete all as specified and as directed.
Supply and fixing pressure reducing valve for Controlling the system pressure within specified limits for following sizes:
Supply and fix gate valve 25 mm dia all as specified and directed.
Supply and fixing Pressure switches of suitable range (0.2 bar to 7.5 bar) for pump sets with ball valve, Fittings like unions / collars / reducers etc and interlock with pump starter for automatic operation complete all as specified and as directed.
Supply and fixing water flow switch 80mm to be fitted in sprinkler main distribution line to operate electrically operated alarm complete all as specified and as directed.
Supply and fixing 28 zone wall mounted sprinkler annunciation panel to give signal to zone hooter AC Input and 12/24 V DC output complete all as specified and as directed.
Supply and fixing of Automatic air-vent having 15mm end connections complete all as specified and as directed.
S&F ball valve 15 mm & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- 1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fasteners and lever and screwed /socket weld end connection with accessories etc., as required all as specified and directed.
M&L for providing Air Vessel complete with drain arrangement tripot stand etc 250 mm dia and 1m height complete all as specified and as directed.
Supply and fix Sprinkler quick/early response type , pendent type, set to operate at 68 deg C brass body quartzoide bulb type automatic sprinkler heads. Sprinkler heads shall be complete with deflector.The finish shall be chrome complete all as specified and as directed .
Supply and fix Sprinkler quick/early response type , upright type, set to operate at 68 deg C brass body quartzoide bulb type automatic sprinkler heads. Sprinkler heads shall be complete with deflector.The finish shall be chrome complete all as specified and as directed..
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) indoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated alluminum bus bar 315 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 2.5 Sqmm. The scope of work includes the following
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm buried directly in ground not less than 2.25 Mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts, check nuts and washers of galvanised iron and 32x6mm GI strip Procter by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip up to main earthing complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed . (i) Main earthing strip from earth plate electrode to test point up to length of 7.5 meters length shall deem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item. (iii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department .
S&F Test point terminal block made of Gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as directed.
Supply and fix aluminium strip 25x3mm complete with saddles and fixing screws for fitting the strip complete all as specified.
Supply and fixing 6 kg capacity Multipurpose dry chemical powder (ABC) type (IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged all as specified and as directed.
Supply and fixing CO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683. Extinguisher shall be painted with red enamel apint and fixed to wall with bracket complete all as specified and as directed.
Supply and fixing 9 Ltr capacity Foam type (IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged all as specified and as directed.
M&L for repair of wall incl. plastering,brick work as per requirement after dismantling of MS pipe ,Fire Hose Cabinet etc and then distemper 2 coats of existing wall colour all as specified and directed
Supply and fixing hose flexible type 1m long all as specified and directed
Supply and fix Sprinkler rossette 25mm dia complete all as specified and directed.
S&F in repair air cushion tank with relief valve 200mm complete all as specified and directed.
M&L for cross arm ,bracings supports clamps,and back plates fabricated from structural steel sections including nuts ,bolts,washers,welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one fininshing coat of paint
Supply installation testing and commissioning of 5Kg automatic modular clean agent fire extinguisher capacity 5 Kgs ceiling suspended working pressure of 30 Kg/cm2 with discharge time 10-15 seconds heat sensitive glass bulb sprinkler head ,heat sensitive range 68 degree UL listed - OT Rooms
Supply installation testing and commissioning of Clean Agent Novec 1230 based Gas Suppression system:- CCOE approved high pressure seamless BIS 7285 pt 34.5 bar approved cylinders , UL/FM approved based Novec 1230 clean agent having zero ODP & GWP<1, stored pressurised system with PESO approved valve assembly incl supervisory switch, panel,nozzle, all pressure gauges, valve electric control wiring etc and any other required to make the system operational
(a) Hospital- Switch Room of size not exceeding 34m3
(b) Hospital- Switch Room of size not exceeding 42m3
(c) Hospital server room of size not exceeding 60m3
(d) Room Integrity test
Supply and fix foot valves, without bypass arrangement, vertical installation, flanged type for iron pipe of dia 150 mm as per IS 4038 incl. taking out old unserviceable valve complete all as directed.
Supply installation testing and commissioning of test drain assembly complete with 25mm dia complete all as specified and directed.
Supply installation testing and commissioning of 50 sqmm 3 core XLPE insulated extruded PVC inner & outer sheathed 1100V aluminium armoured cable including cable trays/supports as per site conditions all as specified and directed.
Supply and fixing one coat of 4 mm thick 'PYKOTE' or 'COATEK' anti rust pipe protection conforming to IS:2021 including PYKOTE primer as per manufacturer specifications and lap of 25mm to make an impermeable layer on M.S pipes running underground/buried/in trenches complete including surface preparation including conducting holiday test.The application process shall be strictly according to manufacturers specification/recommendation.
S&F controlled percolating (CP) fire hose pipe as per IS 636, type 'A' ISI marked, 63 mm nominal internal dia, 30 Mtr long each, duly fitted with stainless steel coupling of 63mm size, ISI marked with multi serrated tail and double instantaneous spring lock arrangement comprising of male half at one end and female half at other end complete with rubber cup washer and conforming to IS 903, suitable for hydraulic pressure of 21kgf/cm2, complete all as specified and directed.
Description of Work / Item(s)
Amount
Supply, installation, connecting, testing and commissioning of addressable Type Multi Sensor Smoke Detectors with mounting base etc. complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable photoelectric type Smoke Detectors with mounting base, blinking LED etc. complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable rate of rise cum fixed temperature Heat Detectors with mounting base, blinking LED etc. complete all as specified and directed
Supply, installation, connecting, testing and commissioning of Addressable Hooters cum strobe min. 80 db output and 110 candelas complete with modules. The strobes shall be synchronised for better evacuation.
Supply, installation, connecting, testing and commissioning of Control Module for Hooter Cum Strobe complete all as specified and directed
Supply, installation, connecting, testing and commissioning of Manual Call Box in ABS plastic as required complete.It shall be Pull handle type with cover complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable fault Isolator complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable control module for A.C. & Access Control System complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable control module for Builder AHUs complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable monitor module for integration of builder panel to main fire panel complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable control module for integration of builder panel to main fire panel complete all as specified and directed
Supply, installation, connecting, testing and commissioning of addressable monitor module for flow switch complete all as specified and directed
Supply, installation, testing and commissioning of Microprocessor based 4 loop panel Networkable analog addressable type fire alarm control panel with 640 character LCD display. The panel shall equiped with sufficient no. of loops, each loop shall have capacity of 250 analog devices in each loop four access levels, capable of taking flash scan devices, Flash EPROM sufficient no. of programmable relay controls for controlling AHU's, pressurization fans, ventilation fans at fire pump room, monitoring of fire hydrant and fire sprinkler, 240v AC power supply, automatic battery charger, 24v sealed lead acid battery sufficient for 24hrs in normal working and 2hrs during emergency as required according to specification. The panel shall be UL864 9th edition listed with response time less than 10sec. The Panel shall be able to Integrate with BMS & Security System on Common TCP/IP Ethernet Communication Bus using BACnet Transfer protocol. The panel shall have the web enabled facility which can able to send or receive e-mails with memory of 1000 events recording complete all as specified and directed.
Supply, installation, testing and commissioning of Microprocessor based 6 loop panel Networkable analog addressable type fire alarm control panel with 640 character LCD display. The panel shall equiped with sufficient no. of loops, each loop shall have capacity of 250 analog devices in each loop four access levels, capable of taking flash scan devices, Flash EPROM sufficient no. of programmable relay controls for controlling AHU's, pressurization fans, ventilation fans at fire pump room, monitoring of fire hydrant and fire sprinkler, 240v AC power supply, automatic battery charger, 24v sealed lead acid battery sufficient for 24hrs normal working and 2hrs during emergency as required according to specification. The panel shall be UL864 9th edition listed with response time less than 10sec. The Panel shall be able to Integrate with BMS & Security System on Common TCP/IP Ethernet Communication Bus using BACnet Transfer protocol. The panel shall have the web enabled facility which can able to send or receive e-mails with memory of 1000 events recording complete all as specified and directed. Note for the Item No 13 & 14 : (a) Main Fire Panel shall have 2 way communication with Main Fire Panel. In case of fire signal all the access control doors shall deactivate. (b) The access control doors will get de activated for people evacuation (c) Emergency evacuation message will pass through public address system (d) The fire panel shall be suitable for BMS compatible with following parameter (i) Should be BMS Compatible (ii) BACnet / MSTP or Modbus output to be provided (iii) Termination of cables in the respective device i.e Deterctors, Manual Call Point & Modules. (e) The vendor shall provide panel UL 9th edition listing certificate.
Supply, installation, connecting, testing and commissioning of UL listed addressable Active Repeater panel complete all as specified and directed.
Providing and fixing in position 1.2mm thick M.S. rectangular outlet boxes for housing smoke detectors, Heat Detectors, manual Call Points, monitor module, control module on the true Ceiling / wall complete with all fixing accessories as required.
Supply, installation, connecting, testing and commissioning of Response Indicator complete all as specified and directed.
Supplying & laying of 2 x 1.5 sqmm fire survival armoured cable, 600 / 1000 V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete all as specified and directed.
Supplying and fixing 25 mm dia MS conduit alongwith all ancillaries and accessories etc complete all as specified and directed.
Supplying and fixing speaker cable two pair, 2 core, 1.5 sqmm complete all as specified and directed.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating alongwith all ancillaries and accessories like coupler etc complete all as specified and directed.
Taking down carefully by disconnecting the following including electrical / mechanical connections complete all as direcated:- (a) Zonal Panel - 29 Nos (b) Heat Detectors - 3869 Nos (c) Ionization Smoke Detectors - 1002 (d) Response Indicators - 2284 Nos (e) Manual Call Points - 272 Nos (f) Hooter - 30 Nos (g) Siren - 01 Nos (h) Optical Smoke detectors - 94 Nos (j) Mimic Panel - 06 Nos (k) Repeater Panel - 01 Nos
Supply, installation, testing and commissioning of loud speaker ceiling mounted type (Simliar to Bosch LBD 0606) with metal grill complete all as specified and directed
Supply, installation, testing and commissioning of loud speaker ceiling mounted type (Simliar to Bosch LC1-PC15G6) with metal grill complete all as specified and directed
Supply, installation, testing & commissioning of Bosch Plena Pree Amplifier capable of delivering 480 W RMS power output, built-in fan for temperature control, built in line matching transformer distortion typically 0.03% @ 1 KHz, Hum and Noise 90 dB below rated output complete all as specified and directed
Supply, installation, testing & commissioning of suitable size of equipment rack for above system made out of CRCA sheet to house all the control equipment complete all as specified and directed
Supply, installation, testing & commissioning of Main Termination Box complete all as specified and directed
Description of Work / Item(s)
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
S&F false ceiling of 12.5 mm thick tapered edge gypsum board confirming to IS 2095 including providing and fixing frame work made out of special sections power pressed from MS Sheet and galvanised in accordance with zink coating and consisting of angle cleat of size 25 mm wide X 1.6 mm thick with flange of 22 mm and 37 mm at 1.2 mtr C/C , Angle fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bolts to the angle hangers of 25x25x0.5-0.8 mm thick running @1.2 mtr C/C to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm , shall be fixed in a direction perpendicular to GI Channel with connecting clips made out of 2.64 mm dia x 130 mm long GI wire at every in including fixing the gypsum board with ceiling section and perimeter channel 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long the perimeter of ceiling fixed to wall / partition with the help of raw plug at 450 mm c/c with 25 mm long screws @ 230 mm internal including jointing and fixing to a flush finish of tapered and square edge the gypsum board with filler and finish with POP as per approved colour, paper tapes including making opening for light fittings ,AC grills,diffusers cut outs made with frames of perimeter channels complete in plain horizontally / vertically location including applying coats of plastic emulsion paint over a coat of approved primer on gypsum board false ceiling horizontally / vertically as specified (at ceiling height up to 8 mtr appx) complete all as specified . Note:- (i) Dismantling of E/M & AC services such as cables and supply lines, ducts and any other service lines has to be removed and refixed as per E/M schedule without affecting existing services and problem during execution. (ii) Ceiling to be executed in any design / pattern / level as per site requirement and measured as clear span.
Taking down carefully existing false ceiling tiles and members of any type/make/size for repair/replacement and refixing the same in its original position without any damage complete all as specified and directed. Note:- If any kind of damage occurred to false ceiling and other services due to negligance or poor workmanship of contractor, the same will be repaired /replaced by the contractor free of cost and no extra payment will be made in this effect to the contractor.
Refixing the dismantled boards of any type/size/make as obtained from Srl item No. 1
M&L for exposed GI frame/grid system duly powder coated for module size of 600x600 mm suitable for lay-in aluminium/mineral fibre ceiling tiles, having main T runner of 24mm size, suspended at 1200mm C/C and cross T runner of 24mm size, suspended at 600mm C/C with interlocking arrangements to form grid of 600x600mm, perimeter runner/channel of 15mm size, main and cross T runner supported by 4mm dia GI rod from slab/Roof, wall angle etc with and including all fixing accessories, complete all as directed.
M&L for metal false ceiling, lay-in type, 0.5mm thick duly powder coated, perforated type with glass fibre acoustic fleece, suitable for false ceiling grid/frame module of 600x600 mm size, complete all as specified and directed. Note:- The grid/frame shall be measured and paid for separately
Supply, installation, testing and commissioning of Addressable TCP/IP enabled Emergency Lighting control Panel (Approved as per BS EN 60598) with 2 lines 160 luminaire circuit self-test system using self contained luminaries, each circuit with maximum 80 luminaires, Circuit length 1000 meters & locally. LCD screen display of 320*480 with keypad to operate & test all addressable luminaires. Automatic function test and duration test of luminaires with search function which require no manual addressing. Automatic e-mail dispatch if faults occur. Panel should monitor lamp, communication, battery & test failure. Electronic log book storage for a period of 4 years. Degree protection IP20. The Panel shall comply as per technical specifications complete all as specified and directed. Certification - EN62368 certified. Makes: Eaton, CEAG, ABB, Apollo Advanced
Supply, installation, Testing & Commissioning of Addressable LED self-contained luminaire - suitable for open area / escape route illumination as per NBC2016 standards. Automatic test for reduced inspection effort, Simple fault analysis and status display via bicolor LED. Housing material Polycarbonate (850 °C glow wire resistant), Ingress protection IP44, Built in lithium battery with 3 hours battery back-up complete all as specified and directed. Certification - EN 60598 & BIS certified. Makes: Eaton, CEAG, ABB, Apollo Advanced
Supply, Installation, testing and commissioning of EN54/BIS approved Addressable Escape sign luminaire with LED Lightguide technology having Additional function: Displaying a red ‘X’ to signify an area as closed or blocked, Minimum service requirement due to high service life of the LEDs (50 000 hours) with complete necessary accessories as per specification complete all as specified and directed. Makes: Eaton, CEAG, ABB,Apollo Advanced
Supply , installation , testing and laying of 2 core *1.5 Sqmm Non shielded FRLS armoured cable for panel to luminare communication.complete all as specified and directed
Supply , installation , testing and laying of 2 core 1.5sqmm - flexible cable for luminare power supply complete all as specified and directed.
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan/plug/bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof/ wall/ floor by applying putty and applying colour/ white wash finish complete all as specified and directed.
(a) One light/fan/bell/exhaust fan point controlled by one switch.
(b) One 3 Pin socket outlet 5 Amps on Independent board.
(c) One 3 Pin socket outlet 5 Amps on same board.
(d) One light point controlled by two, two way switch
All as per srl item No. 14 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
All as per item No. 14 above but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 20 / 25 Amps point and one single core 4 sq mm PVC insulated unsheathed copper cable as earth continuity conductor.
S & F Modular Switch 1 way 16 A, 1 Module complete all as specified and directed
S & F Modular Socket 6 / 16 A - 2/3 Pin combined 2 module complete all as specified and directed
S & F Modular Switch 1 way 6 /10 A, 1 Module complete all as specified and directed.
S & F Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module complete all as specified and directed.
S & F Modular Switch 2 way 6 / 10 A, 1 Module complete all as specified and directed.
S & F Modular fan regulator step type, 120W 2 Module complete all as specified and directed.
S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed.
S & F of Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, 240 Volts, complete all as specified and directed.
S & F Modular AC Box Metal box, power socket with top 240 volts AC complete with one SP MCB, 20 amps concealed / flush to wall surface complete all as specified and directed.
Supply Installation, testing & comissioning in replacement of intregral LED 4ft luminaire of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 18/20Watt LED with colour consistency SDCM≤ 5,CRI≥ 80 and colour temperature - 4000 to 6500K, Luminaire shall be designed to emit at least 2000 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 18W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 2.5KV, electrical insulation class should be Class I &driver should be of class B serviceablility. the PIR sensor should be able to dim the fixture to 50% in case of no movement, sensor should have a detection angle of 60 degree and luminaire should be at least IP20 & IK02 rated. the minium dimensions (+5mm) of the batten shall be 40mm(+5mm)x80mm(+5mm)x1100mm(+5mm). The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & "FAT" before dispatch as per IS 10322. the successful bidder must submit the NABL accredition certificate for luminaire manufacturer along along with technical bid. the LED Luminaire & It's driver both should be BIS registered successful bidder shall submit the following reports before supply of material for approcals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. Similar to above specs in Signify (Philips/Havells/Wipro/regent).
Supply install testing and commissioning of 34/35 watt, (2' x2') Recessed Mounted square luminaire made of CRCA & with single piece molded polycarbonate diffuser. The diffuser shall be so designed that it deos not protude below the luminaire/ceiling & is able to give more volumetric light & higher vertical illumination. The luminaire shall be so desiged that it emits light from the inner side walls of the luminaires & shall be hollow from centre. The outer dimentions of the luminaire shall be L-595mm, W:595mm & H: 70mm & the cutout size hollow portions shall be approx 580mmX580mm (Tolerance in all dimentions ± 5mm). The hollow portion of the luminair should an option to be covered with customizable backplate or un-cut grid ceiling tile.Luminaire shall deliver minimum system lumens of 3910lumens with a system luminous efficacy ≥115 lm/W, system wattages ≤ 34W & integral module with lumen efficacy of ≥140lm/W and viewing angle of 120°to ensure better uniformity.It should have CCT of 5700K CRI ≥ 80,SDCMs. The life shall be L70850@ 50K Hrs. The luminaire driver shall have THD≤10% @ full load,PF ≥ 0.90@ full load, internal surge protection of 2KV,operating voltage range of 140V-270V.The luminaire shall have serviceability of Class B. The luminire shall be IP20 compliant. The fixture design should be with flicker free operation having ripple ≤ 5% the LED driver should comply to IEC61000.3.2,2009 for Harmonics, IEC61347-2-13, 2006 IN Conjuction WITH IEC61347-1 ED 2.0, 2007 for Electrical safety, CISPR 15/EN 55015 (9 khZ TO 30MHz) for RFI, EMI/EMC, IEC 62384 for driver performance test. The luminaire driver shall have efficiency of ≥85%. The luminaire driver shall be of the same make /manufacturer/ brand as that of LED luminaires. The luminaire & driver shall have BIS registration & the bidder shall submit the BIS certificate along with technical BID. The LED luminaire manufacturer should have in-house NABL accredited lab to conduct type test, factory acceptance test before dispatch of material,LM79 test & IK test.The bidder shall submit the NABL accreditation of LED luminaire manufacturer alone with technical bid. The bidder shall submit the type test of luminaires & LM79 test reports issued by NABL accredited lab before supply of material. product complying to above specs in signify, LT or Endo (Philips/Havells/Wipro/regent).
S & F in replacement of IP20 Recessed LED Downlight 18 W, made of pressure die cast aluminum housing, Fixture should have minimum efficacy at System level (Not Chip Level) >=110 lumens/watt with Minimum system Lumens 2000 with maximum system wattage of 18W. Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<5), CRI >80, PF >0.95, working temp range - 0°C < Ta < 45°C, and operating Voltage Range of 240 VAC. It should has a Minimum Internal Surge Protection of 2.5KV. Electronic Switchable ballast. The fixture design should comply with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire.Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer. Product complying to above specs in Signify, (Philips) / Wipro / LT.
S & F in replacement of IP20 Recessed LED Downlight, not less than 13 W, made of pressure die cast aluminum housing, Fixture should have minimum efficacy at System level (Not Chip Level) >=110 lumens/watt with Minimum system Lumens 1500 with maximum system wattage of 13.5W. Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K (SDCM<5), CRI >80, PF >0.95, working temp range - 0°C < Ta < 45°C, and operating Voltage Range of 240 VAC. It should has a Minimum Internal Surge Protection of 2.5KV. Electronic Switchable ballast. The fixture design should comply with EMC / EMI compliance along with BIS certification for LED Driver & Luminaire.Luminaire manufacture shall provide LM79report from NABL accredited lab & LM80 report issued by LED manufacturer. Product complying to above specs in Signify, (Philips) / Wipro / LT.
S & F in replacement of LED light Bulkhead fitting 1x9W / 1X10W, luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make Philips / Havells / Wipro.
Taking down carefully LED lumainaire of 600mm x 600mm recessed type complete with electrical wiring and refixing the same connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Taking down carefully LED lumainaire of roundtype recessed type complete with electrical wiring and refixing the same connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Taking down carefully Tube fitting 20 W of any type complete with electrical wiring and refixing the same connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified and directed.
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including steel conduit 20 mm dia or higher, complete with all conduit accessories and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as directed. Note :1. The two run of 6 Sqmm wire, one run of 6 Sqmm wire and 1 mtr steel conduit pipe will be measured as one unit. 2. Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including steel conduit 20 mm dia or higher, complete with all conduit accessories and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB complete all as directed. Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire and 1 mtr steel conduit pipe will be measured as one unit. 2. Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 6 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 12 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed.
S & F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 8 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed.
S & F in replacement RCBO, 230 Volt, 40 Amp, 30mA, 50 Hz, with 10 kA short circuit capacity of Double pole for ensuring protection from leakage current, short circuit & over load to the user for a particular circuit. In normal use, it is safe to use and free of threat to user as well as to environment in accordance with IS 12640-2 & IEC 61009-1 in the SPN DB as outgoing all as specified. Make :Legrand/Siemens /Havells /Schneider
S & F in replacement RCBO, 415 Volt, 40 Amp, 30mA, 50 Hz, with 10 kA short circuit capacity of 4 pole for ensuring protection from leakage current, short circuit & over load to the user for a particular circuit. In normal use, it is safe to use and free of threat to user as well as to environment in accordance with IS 12640-2 & IEC 61009-1 in the TPN DB as outgoing all as specified. Make :Legrand/Siemens /Havells /Schneider
Supply and installation of a Surge Protective Device (SPD) , 40Amp with T2/20KA, 2-pole, CT1 protection mode. SPN DB as incomer complete with all necessary connections.(Incomer)
Supply and installation of a Surge Protective Device (SPD) , 40Amp with T2/20KA, 4-pole, CT1 protection mode. TPN DB as incomer complete with all necessary connections.(Incomer)
S & F in replacement MCB, SP, 40 to 63 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed
S & F in replacement MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed
S & F in replacement MCCB, 415 Volt, 16kA, 4 pole, 100 Amp capacity with over load and short circuit protection complete all as specified and directed
Taking down carefully ceiling / exhaust fan of any size, sealing cable end, dismantling blades & removing fan and blades to store complete all as directed.
M & L for painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filter one coat after cleaning all as directed
Hanging only with fixing accessories ceiling fan and connecting with and including 3 core flexible copper cable from ceiling rose to fan all as directed
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose to fan all as directed.
M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Operation Threatre distribution board/ panel (medical grade) as per specifications mentioned below :- (a) The panels shall be isolated panel system only, having critical (isolated) and non-critical circuits. Both circuits shall be monitored on the building management system. The monitoring parameters shall include On/Off status, load monitoring and shall generate alarms if any critical parameters such as isolation is anomalous. The panel shall enable electrical shock protection: according the IEC 60364-7-710 standard the solution is in compliance with the group 2 location through isolation transformer and associated monitoring system. (b) The system shall be according the IEC standard, the switchgear is energy by 2 separate sourcing. (c) The “Main incomer supply” is coming from the UPS system. The “Safety incomer supply” is coming directly from the other part of the main low voltage switchgear. An automatic change over shall transfer the energy sourcing from the “Main incomer supply” to the “Safety incomer supply” in case of outages in less than 30ms. (d) The Utility and Genset sourcing should limit by 15 seconds at least any potential outage to re-energise the Main and Safety incomers. The wiring shall be in compliance with the recommendations of IEC 60364-4-4-44, IEC 61000-6-2 and IEC 61000-6-3. It shall be possible for the protective devices to be controlled by the maintenance staff, without risk of direct contact. (e) The power and communication circuit routing shall be completely separate. Pulse energy meters with inbuilt CTs shall be provided with incomers to the panel for getting the energy consumption data for operation theatre. (f) The system should be able to locate faults in case of tripping Communication auxiliaries, for communicating ON/OFF/Trip status shall be provided with all MCBs, RCCBs, RCBOs used for protection. The status shall be available over Modbus TCP/IP network. Smartlink or equivalent shall be used for communicating the status of protection devices.
(g) The System Controller shall transfer all data to BMS/ Central Monitoring room, shall include suitable number of DI/DOs to control and monitor the panels. The controller has 01 Nos. isolated RS 485 communication port, 1 Nos. Ethernet communication port with 10BASE-T/ 100BASE-TX, support : Modbus master/slave, BACnet, MBUS and DNP 3.0 protocols, and shall conform to ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, EN/IEC 61131-2:2007 standards, 230VAC with inbuild 4G modem and has DIDO Capability for adding upto 256 DI/DOs/AI/AOs. The controller sends data with TLS encryption and the data on controller shall be encrypted. The controller shall be able to store data till it is received by the BMS room to avoid any data loss. The system shall have the following components :- (i) 63A, FP, Isolator, Complies to IEC/EN 60947-3- 2 Nos (ii) Contactor 60A, FP AC-1 duty 230V 50/60Hz for 10 KVA- 2 Nos (iii) Mechanical interlock for LC1 D60- 1 No. (iv) On delay Timer 2C/O, 230V AC- 1 No. (v) Miniature circuit breaker ACTI 9, C60, 2 poles, 2A, C Curve - 2 Nos (vi) Polybloc 160A 1P - 2 Nos (vii) Miniature circuit breaker ACTI 9, C60, 2 poles, 2A, D Curve- 1 No. (viii) AC Residual Current Circuit Breaker, 40A, 100mA- 1 No. (ix) Digital VAF Meter With RS 485 Modbus Port- 1 No. (x) Current transformer 40/5A Class 1 10VA- 3 Nos (xi) CT Shorting Links- 3 Nos (xii) Miniature circuit breaker ACTI 9, C60, 2 poles, 16A, C Curve- 6 Nos (xiii) Auxiliary contact, 1 OC- 6 Nos (ix) Multiclip distribution block- 1 No. (x) Miniature circuit breaker ACTI 9, C60, 2 poles, 4A, C Curve- 1 No. (xi) Universal Power Supply 24V DC 5A- 1 No. (xii) Miniature circuit breaker ACTI 9, C60H-DC, 500Vdc, 2A, 2 poles, C Curve- 1 No. (xiii) IMD Vigilohm IM20-H a positive safety 220/240V AC, 50H- 1 No.
Supply, installation, testing and commissioning PVC insulated Copper Conductor (Sheathed), flexible cable, 1100 volts grade of size 4 core 25Sq mm including taking out old un-serviceable cable complete all as specified and directed.
Supply, installation, testing and commissioning PVC insulated Copper Conductor (Sheathed), flexible cable, 1100 volts grade of size 4 core 16Sq mm including taking out old un-serviceable cable complete all as specified and directed.
Supply, installation, testing and commissioning PVC insulated Copper Conductor (Sheathed), flexible cable, 1100 volts grade of size 4 core 10Sq mm including taking out old un-serviceable cable complete all as specified and directed.
Supply, installation, testing and commissioning PVC insulated Copper Conductor (Sheathed), flexible cable, 1100 volts grade of size 4 core 6Sq mm including taking out old un-serviceable cable complete all as specified and directed.
M&L for cablofil hot dip galvanized cable trays, top cover, wall supports and jointing/fixing accessories for fixing over walls complete, size 54mm (Height) x 100mm (Width) all as per cat No. CM000073 of Legrand-Cablofil or techno commercially equivalent in other makes specified and directed.
B D Raizada Projects Pvt Ltd
M M SHAWL Engineers and contractors pvt ltd
SOOD ASSOCIATES PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
SHREE GAUTAM CONSTRUCTION COMPANY LIMITED
Cosmos Systems
SOOD ASSOCIATES PVT LTD
M M SHAWL Engineers and contractors pvt ltd
B D Raizada Projects Pvt Ltd
Cosmos Systems
NITYA NAND AND SONS CONTRACTORS PVT LTD
SHREE GAUTAM CONSTRUCTION COMPANY LIMITED
M M SHAWL Engineers and contractors pvt ltd
NITYA NAND AND SONS CONTRACTORS PVT LTD
SOOD ASSOCIATES PVT LTD
B D Raizada Projects Pvt Ltd
SHREE GAUTAM CONSTRUCTION COMPANY LIMITED
NAFREF ENGINEERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid