Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹80.8 L
EMD Value
₹1.6 L
Closing Date
8 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SANJEEV KUMAR TYAGI
Hansi PHED
Hansi Town Detailed estimate for renovation and Up gradation of 1st and 2nd water Works Hansi Town Distt. Hisar. 2 Nos Crossing of NHAI NH-9 and laying of 600 mm i/d DI pipe line for Hansi Town Distt Hisar
2025_HRY_493527_1
202509354FA5 A8AE 4DA4 BF2B 616CF17BFD8B567PUH
Open Tender
Civil Works
Works
365 days
Hansi
5 documents required · 5 mandatory
₹5,000
₹1.6 L
Yes
27 Jan 2026
29 Dec 2025
8 Jan 2026
29 Dec 2025
8 Jan 2026
29 Dec 2025
Boring excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine In normal soil condition but not In Rock/Boulders, any underground utility like foundation, water supply line coming in alignment or other underground obstruction complete in all respect Including site clearance etc. before finalizing the alignment for 1030 mm o/d MS Casing Pipe (14 mm Thick)
Boring excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine In normal soil condition but not In Rock/Boulders, any underground utility like foundation, water supply line coming in alignment or other underground obstruction complete in all respect Including site clearance etc. before finalizing the alignment for 830 mm o/d MS Casing Pipe (12 mm Thick)
Cleaning of surface of M.S pipe (casing pipes) inner surface and outer surface by sand blasting at site to make the surface ready for P.U coating /high build epoxy paint/ polythene tap system complete in all respect.
Cleaning of surface of M.S pipe (casing pipes) inner surface and outer surface by sand blasting at site to make the surface ready for P.U coating /high build epoxy paint/ polythene tap system complete in all respect…
Coating of 1030 o/d MS pipe outer and inner surface of casing with 100 % elastomeric polyurethane coating to AWWA-C2A/C222-1999 specifications to 1000 V dry film thickness for protection again corrosion complete in all respect..
Coating of 830 o/d MS pipe outer and inner surface of casing with 100 % elastomeric polyurethane coating to AWWA-C2A/C222-1999 specifications to 1000 V dry film thickness for protection again corrosion complete in all respect.
Dismantling of Electric Poles with foundation and reinstalling the poles and making the foundation at same place after completion of work as per norms of Railway Department
Ground probe rader survey to check any underground obstruction before finalization the alignment
Providing and fixing caution sign boards, signals, watching fencing etc.
Providing and fixing spacer at distance of 2 mtr. avoid contact of casing pipe and carrier pipe complete in all respect. for 1030mm o/d M.S. Pipe with 14 mm thick casing pipe..
Providing and fixing spacer at distance of 2 mtr. avoid contact of casing pipe and carrier pipe complete in all respect. for 830mm o/d M.S. Pipe with 12 mm thick casing pipe..
Providing and insertion of 1030 mm o/d M.S. casing pipe 14 mm thick (For-330 grade) fabricaled as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high build epoxy paint as per R.D.S. specification and C/PCN.I/88 to a dry film thickness of 250 micron for protection against corrosion including cost and carriage of material to site of work complete in all respect 1030 mm o/d MS casing pipe.
Providing and insertion of 830 mm i/d M.S. casing pipe 12 mm thick (For-330 grade) fabricaled as per IS: 3589 of 1991 from steel plates conforming to IS 2062 including cutting, beveling, grinding and radio graphically welding of pipes as per IS-1182 and also coating of inner and outer surface of casing pipe with high build epoxy paint as per R.D.S. specification and C/PCN.I/88 to a dry film thickness of 250 micron for prelection against corrosion including cost and carriage of material to site of work complete in all respect 830 mm i/d MS casing pipe.
Percentage BoQ
BoQ_Ver3.0
Contact No: 01663-256145
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
HSR Itmes
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.06 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
BOQ_571921.xls
BOQ • 0.26 MB
FF3G9NZ140094.pdf
Additional Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .