Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
22 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work that includes Smoke and Fire Detection and Alarm System for signalling installations at RRI/EI/PI stations or for Telecom installation in Indian Railways or in any other Govt/PSU Organizations.
50 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Instructions and conditions to Tenderers :
Every tenderer shall state in the tender his postal address fully and clearly. Any communication sent in time to the tenderer by post at the said address shall be deemed to have reached the tender duly and in time. Important documents shall be sent by Registered post.
In case of any information/certificates submitted by tenderer is found to be false/forged or incorrect at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of EMD/SD and Performance guarantee besides any other action provided in the contract including banning of business for a period of upto five year.
The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the Contractor. The Contractor shall be responsible for deposition of applicable GST to the concerned authority.
I f the bidder (any member i n case o f JV/consortium) must not have suffered bankruptcy/ insolvency during the last 5 years. The Bidder should submit an undertaking to this effect as part of the bid.
Bidders must not have a conflict of interest. Following shall be considered as conflict of interest in this bidding process :
If a Bidder or her associates/affiliates (inclusive of parent firms) has been engaged by the Employer (Railways) to provide consulting services for the preparation related to procurement or on implementation of the project;
Provision of Aspiration type Smoke Detector System at stations as per RDSO's TAN vide No. STS/E/AFD&SS Vol.-V dt: 17/02/2025 in RNY Division
RN-ST-21-2026-27~NFR
RN-ST-21-2026-27
Open
Works - General
365 Days
Kamrup, Assam
₹0
₹3.2 L
28 Sept 2026
28 Sept 2026
8 Oct 2026
17 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,62,26,037.1 | ||
| — | 2.00 | — | — | ||
| Supply, Installation,Testing & Commissioning of Networkable type Microprocessor based intelligent Addressable,FireAlarm Control Panel (FACP) with LCD Display complying to RDSO spec.No. RDSO/SPN/217/2025Version-3.1or Latest. The panel should have inbuilt TCP/IPcommunication for Panel Program and Remote Monitoring option through LAN or WAN communication. It should have GSM interface for SMS generation.The panel shall be able to give location of all fire and More Fire/fault and isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing up to a minimum of 512 fire events and other events Further the panel must be able to automatically switch ON/OFF respective control module whenever any alarm is triggered. The panel should have in built commonAlarm, Fault and monitored sounderoutput.Thepanel shall havea LCD/LED display and alphanumeric keyboard and analog output, external/inbuilt printer to logall fireor fault events complelte inall respects. ThePanel shouldhaveprotection category of IP30.Also thepanel shouldhave theoption to operate in manned and unmanned mode.The control panel shall have inbuilt charging facility forDCbattery backup for at least 24 hours for operating the system atquotient loadand then15 minute under fire or emergency condition at maximum connected load (Cl. 10.6.7.2.1.2ofNFPA72Edition2016), The Panel Shall be approved by UL or FM or Vds or LPCB | — | — | — | 4,48,700.1 | |
| — | 15.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicatorwith 360 degree viewing angle.Detector shall communicate3danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current.Detector shouldhave unique address for communicationand assigned through panel with mounting base as required with the protection category of IP 40. All items as per RDSO Specification No. RDSO/SPN/217/2025 Version -3.1 or latest. | — | — | — | 46,830 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of intelligent Addressable Loop Powered Sounder cum beacon withbase inbuilt fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/SPN/217/2025 Version -3.1 or latest. | — | — | — | 16,550 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing&Commissioning of Analogue Addressable Manual Call Point with integral short circuit isolator, inbuild fault isolator suitable for wall or surface mounting, have protection category of IP44, Analogue addressable protocol having status LED for alarming & standby mode, electronically addressed), call point shall include test key featurewithout removing the glass as per RDSO Specification No.RRDSO/SPN/217/2025Version-3.1 or latest. | — | — | — | 7,500 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of LHS interface module as per RDSO Specification No. RDSO/SPN/217/2025 Version -3.1 or latest. | — | — | — | 88,520 | |
| — | 150.00 | — | — | ||
| Supply and Installation of Linear Heat Sensing (LHS) cable as RDSO/SPN/217/2025 Version -3.1 or latest. (Should be procured from RDSO approved Vendor) | — | — | — | 1,24,500 | |
| — | 81.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Air Sampling Type detector shall use LASER type. This type of detector shall use piping or tubing distribution network that shall run from the detector to the area as to be protected. It should be supplied with required module & Power supply unit complete as a system with all accessories like pipes, Sampling points etc. as per RDSO Specification No. RDSO/SPN/217/2025 Version -3.1 or latest. | — | — | — | 1,53,10,377 | |
| — | 1620.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of FRLS armoured copper cable 2C X1.5 sq mm, 1000V rated, twisted (when the entire circuit is not within the same building) OR unarmoured 2C X 1.5 Sq mm, LSH cable-500 V rated twisted, with ATC insulated circuit protective conductor of 1.5 Sq mm, aluminium tape screening (when the entire circuit is within the same building) as per item no. 4.11.3 & 4.11.4 of RDSO/SPN/217/2025 Version -3.1 or latest. | — | — | — | 1,83,060 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CorrectionslipNo-12GCC.pdf
ATTACHMENT
TDAirsamplingtypeAFDASatStation.pdf
ATTACHMENT
Acceptance of eBG
ATTACHMENT
FORMATFORWORKCOMPLETIONCERTIFICATE_1.pdf APPENDIX1
ATTACHMENT
ACS-1to11_compressed.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
JPOCablelaying.pdf
ATTACHMENT
2.0TenderForms.pdf
ATTACHMENT
3.0ChapterVI-VII.pdf
ATTACHMENT
4.0MakeInIndia.docx.pdf
ATTACHMENT
FORMATFORWORKCOMPLETIONCERTIFICATE_1.pdf
ATTACHMENT
2026_06_16Acceptanceofe-BankGuaranteee-BGinWorksContractsandPGMS_PMS_PSSAGC.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .