| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96.7 LAccepted-AOC PLOT NO 927 SECTOR 47 GURGAON 2022R6406 | GURGAON | ₹96.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.0 Cr+₹3.4 L (3.49%)Rejected-Finance ADJOINING PREET PALACE LUDHIANA HIGHWAY NH 95 MORINDA BYPASS VILLAGE BADDI MADOULI MORINDA RUPNAGAR PUNJAB 140101 | MORINDA | RUPNAGAR | PUNJAB | 140101 | ₹1.0 Cr+₹3.4 L (3.49%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.0 Cr+₹4.1 L (4.20%)Rejected-Finance TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | ₹1.0 Cr+₹4.1 L (4.20%) | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Prime Computers L3 | PROMARK TECHSOLUTIONS PRIVATE LIMITED L2 | Kenbrook Automation Private Limited L1 |
|---|---|---|---|---|---|---|
| 1.01 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] | 9,400 | Metre | 35 ₹3,29,000 | 33 ₹3,10,200 | 32 ₹3,00,800 Lowest |
| 1.02 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 2,000 | Metre | 35 ₹70,000 | 31 ₹62,000 Lowest | 32 ₹64,000 |
| 1.03 | `Supply Installation Testing and Commissioning of Micro processor based Fire Alarm Control Panel (FACP) with required 2 wire fault tolerant loop Cards (each loop should support 120 detector, 120 devices or 240 in any combination). The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. Addresses of each Fire Alarm Detector/Module/Hooter/Manual Call Point etc., shall be legibly marked near/on respective sensors. It Should have provision for triggering/integrating the Gas Suppression System, PAVA System and Fire Fighters Telephone System. Panels should have provision of CPU Redudancy, and should work in degrade mode in case of CPU failure.
• Up to 3000 soft zones, logic groups with (AND, OR, NAND, NOR functions) can be created, in network configuration upto 250 Panels. • FACP should support networking. • FACP should support programming through i) Touchscreen ii) USB port iii) TCP/IP Port. • Control-by-event (CBE) equations for activations with logical operators • Historical log : 1,00,000 events • Auto-programming with automatic recognition of the model of the devices • Decision algorithms for the alarm, pre-alarm and faults • Automatic day / night sensitivity change • Indication of the need to clean the smoke sensors • Programmable alarm threshold for detectors. • Zone wise Walk-Test function. • Onboard Repeater Circuit, should be able to connect upto 64 repeaters. • 7-inch Touch Screen, 800 x480 resolution • Inbuilt Modbus / BACnet Card for BMS Integration • The Panel Shall have provision to add Zones LED display with Individual Zone Indicators expdable upto 1280 LED Indicators and provision to add 640 individual Programmable buttons. • Relay Output: 1 fault (NO/NC): 1 alarm, 1 Supervisory/FPE, and 2 optional (Form C contact user defined). • Souder Output: 1 (monitored balanced with resistor or diode) • 1 Programmable NAC Output or 24V Selectable output Max 2.5 A (NAC plus AUX) • The panel shall have a built in power supply 100 ~ 240 V AC, 50 / 60 Hz and Battery charger which should maintenance free type from 12Ah to max 65Ah of 12 V each. • The supply and installation of the entire FACP system shall conform to EN54 Part-2 / NFPA 71 and 72 norms. All equipment and systems shall be tested and approved by LPCB/UL/FM confirming to IS2189 Standard.6 loop panel
Make:GST/ Honeywell/ Edward/` | 1 | Each | 5,05,300 ₹5,05,300 | 4,85,700 ₹4,85,700 Lowest | 4,98,500 ₹4,98,500 |
| 1.04 | `SITC of Intelligent Addressable Heat/Thermal Detector with 3600 LED view, Electronically addressable complete with Mounting Base. The detector shall share the analog datapoints to the panel. The detector should have strong environmental adaptability by drift compensation with 2 programmable sensitivity levels. The detector shall operate in -10°C ~ 50°C Temperature and will give alarm in case of ROR (Rate of rise plus 10 ºC in 1 min) or at a Fixed heat temperature at (58 ºC). Operating Voltage shall be 16 to 28 Vdc. The Detector shall meet RoHS standard and shall confirm to IS2189 Standards and Duly Approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices).
Make:GST/ Honeywell/ Edward` | 6 | Each | 3,200 ₹19,200 | 2,900 ₹17,400 Lowest | 2,950 ₹17,700 |
| 1.05 | `SITC of Intelligent Addressable Photoelectric smoke Detector with 3600 LED, Electronically addressable complete with Mounting Base. The detector shall share the analog datapoints to the panel. The detector should have strong environmental adaptability by drift compensation with 2 programmable sensitivity levels. Operating Voltage shall be 16 to 28 Vdc. The detector shall operate in -10°C ~ 50°C Temperature and will give alarm in case of smoke detection. The Detector shall meet RoHS standard and shall confirm to IS2189 Standards and Duly Approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices)
Make:GST/ Honeywell/ Edward`. | 165 | Each | 3,350 ₹5,52,750 | 3,120 ₹5,14,800 | 3,000 ₹4,95,000 Lowest |
| 1.06 | `Supply, Installation, Testing and Commissioning of Active Network Repeater Panel (NRP) with minimum 7`` 800 x480 resolution Color Touch Screen display having controls for reset, mute, accept, silence alarms and self test conforming to IS2189 standards, mapping 250 panels on network and 100000 event History. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. NRP can act as Remote Zone Annunciation panel and should work on 30 VDC and 1A as required to complete the installation and complete as per specification/drawings and as directed by Engineer In Charge and duly approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard.
Make:GST/ Honeywell/ Edward` | 3 | Each | 98,500 ₹2,95,500 | 80,000 ₹2,40,000 | 77,500 ₹2,32,500 Lowest |
| 1.07 | `SITC of Intelligent Intelligent Addressable Type Manual Call Point having Surface or flush mounting option with Electronically Addressable type. Operating voltage 16 to 28 Vdc and shall complete with Back Box for Mounting Complete as required conforming to IS2189 Standards and Duly Approved by LPCB/UL/FM/relevant NFPA/EN Standard required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.
Make:GST/ Honeywell/ Edward` | 12 | Each | 3,800 ₹45,600 | 3,750 ₹45,000 | 3,650 ₹43,800 Lowest |
| 1.08 | `SITC of approved make Addressable Loop Powered Sounders cum Strobes or Sounder Strobe with Control Module and Power Supply with all accessories. Device should be Electronically Addressable type and should support 16 type programmable alarm tones with option to switch off light/sound for special applications. Operating voltage shall be 20 to 28 Vdc. Sound output of 86 dB @ 1m with High output Light technology and superior lens design optimize light outputs conforming to IS2189 Standards and device shall be compatible with the detector base and Duly Approved by LPCB/UL/FM/relevant NFPA/EN Standard
Make:GST/Honeywell/ Edward` | 12 | Each | 6,800 ₹81,600 | 6,500 ₹78,000 Lowest | 6,750 ₹81,000 |
| 1.09 | `Supply Installation Testing and Commissioning of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power suppl, relay etc..
Make: National/Kheraj/Heinrich` | 1 | Each | 9,000 ₹9,000 Lowest | 10,900 ₹10,900 | 10,000 ₹10,000 |
| 1.10 | `Supply Installation Testing and Commissioning of Co2 type Fire Extinguisher 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark
Make:Safex / Minimax /Ceasefire` | 15 | Each | 8,540 ₹1,28,100 | 7,900 ₹1,18,500 Lowest | 8,100 ₹1,21,500 |
Tender Value
₹98.3 L
EMD Value
₹2.0 L
Closing Date
20 Apr 2026, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Construction of Admin Block in SDO Civil Complex at Tauru in Nuh District (CMA 25674 dated 23.01.2021) (Pdg. CCTV, LAN, EPABX, Fire Alarm and Access Control System only)
2026_HRY_514447_1
202637E561ED C519 4FD5 8CA6 5B5A3E091975668BAR
Open Tender
Civil Works
Works
200 days
Taoru
2 documents required · 2 mandatory
₹5,000
₹2.0 L
Yes
13 Aug 2026
10 Apr 2026
21 Apr 2026
10 Apr 2026
20 Apr 2026
10 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] | - | Metre | - | - |
| 1.02 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | - | Metre | - | - |
| 1.03 | `Supply Installation Testing and Commissioning of Micro processor based Fire Alarm Control Panel (FACP) with required 2 wire fault tolerant loop Cards (each loop should support 120 detector, 120 devices or 240 in any combination). The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. Addresses of each Fire Alarm Detector/Module/Hooter/Manual Call Point etc., shall be legibly marked near/on respective sensors. It Should have provision for triggering/integrating the Gas Suppression System, PAVA System and Fire Fighters Telephone System. Panels should have provision of CPU Redudancy, and should work in degrade mode in case of CPU failure.
• Up to 3000 soft zones, logic groups with (AND, OR, NAND, NOR functions) can be created, in network configuration upto 250 Panels. • FACP should support networking. • FACP should support programming through i) Touchscreen ii) USB port iii) TCP/IP Port. • Control-by-event (CBE) equations for activations with logical operators • Historical log : 1,00,000 events • Auto-programming with automatic recognition of the model of the devices • Decision algorithms for the alarm, pre-alarm and faults • Automatic day / night sensitivity change • Indication of the need to clean the smoke sensors • Programmable alarm threshold for detectors. • Zone wise Walk-Test function. • Onboard Repeater Circuit, should be able to connect upto 64 repeaters. • 7-inch Touch Screen, 800 x480 resolution • Inbuilt Modbus / BACnet Card for BMS Integration • The Panel Shall have provision to add Zones LED display with Individual Zone Indicators expdable upto 1280 LED Indicators and provision to add 640 individual Programmable buttons. • Relay Output: 1 fault (NO/NC): 1 alarm, 1 Supervisory/FPE, and 2 optional (Form C contact user defined). • Souder Output: 1 (monitored balanced with resistor or diode) • 1 Programmable NAC Output or 24V Selectable output Max 2.5 A (NAC plus AUX) • The panel shall have a built in power supply 100 ~ 240 V AC, 50 / 60 Hz and Battery charger which should maintenance free type from 12Ah to max 65Ah of 12 V each. • The supply and installation of the entire FACP system shall conform to EN54 Part-2 / NFPA 71 and 72 norms. All equipment and systems shall be tested and approved by LPCB/UL/FM confirming to IS2189 Standard.6 loop panel
Make:GST/ Honeywell/ Edward/` | - | Each | - | - |
| 1.04 | `SITC of Intelligent Addressable Heat/Thermal Detector with 3600 LED view, Electronically addressable complete with Mounting Base. The detector shall share the analog datapoints to the panel. The detector should have strong environmental adaptability by drift compensation with 2 programmable sensitivity levels. The detector shall operate in -10°C ~ 50°C Temperature and will give alarm in case of ROR (Rate of rise plus 10 ºC in 1 min) or at a Fixed heat temperature at (58 ºC). Operating Voltage shall be 16 to 28 Vdc. The Detector shall meet RoHS standard and shall confirm to IS2189 Standards and Duly Approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices).
Make:GST/ Honeywell/ Edward` | - | Each | - | - |
| 1.05 | `SITC of Intelligent Addressable Photoelectric smoke Detector with 3600 LED, Electronically addressable complete with Mounting Base. The detector shall share the analog datapoints to the panel. The detector should have strong environmental adaptability by drift compensation with 2 programmable sensitivity levels. Operating Voltage shall be 16 to 28 Vdc. The detector shall operate in -10°C ~ 50°C Temperature and will give alarm in case of smoke detection. The Detector shall meet RoHS standard and shall confirm to IS2189 Standards and Duly Approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices)
Make:GST/ Honeywell/ Edward`. | - | Each | - | - |
| 1.06 | `Supply, Installation, Testing and Commissioning of Active Network Repeater Panel (NRP) with minimum 7`` 800 x480 resolution Color Touch Screen display having controls for reset, mute, accept, silence alarms and self test conforming to IS2189 standards, mapping 250 panels on network and 100000 event History. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. NRP can act as Remote Zone Annunciation panel and should work on 30 VDC and 1A as required to complete the installation and complete as per specification/drawings and as directed by Engineer In Charge and duly approved by LPCB/UL/FM with relevant IS/EN/NFPA Standard.
Make:GST/ Honeywell/ Edward` | - | Each | - | - |
| 1.07 | `SITC of Intelligent Intelligent Addressable Type Manual Call Point having Surface or flush mounting option with Electronically Addressable type. Operating voltage 16 to 28 Vdc and shall complete with Back Box for Mounting Complete as required conforming to IS2189 Standards and Duly Approved by LPCB/UL/FM/relevant NFPA/EN Standard required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.
Make:GST/ Honeywell/ Edward` | - | Each | - | - |
| 1.08 | `SITC of approved make Addressable Loop Powered Sounders cum Strobes or Sounder Strobe with Control Module and Power Supply with all accessories. Device should be Electronically Addressable type and should support 16 type programmable alarm tones with option to switch off light/sound for special applications. Operating voltage shall be 20 to 28 Vdc. Sound output of 86 dB @ 1m with High output Light technology and superior lens design optimize light outputs conforming to IS2189 Standards and device shall be compatible with the detector base and Duly Approved by LPCB/UL/FM/relevant NFPA/EN Standard
Make:GST/Honeywell/ Edward` | - | Each | - | - |
| 1.09 | `Supply Installation Testing and Commissioning of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power suppl, relay etc..
Make: National/Kheraj/Heinrich` | - | Each | - | - |
| 1.1 | `Supply Installation Testing and Commissioning of Co2 type Fire Extinguisher 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark
Make:Safex / Minimax /Ceasefire` | - | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
BOQ_593274.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .