| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 Cr+₹12.8 L (7.28%)Rejected-AOC | ₹1.9 Cr+₹12.8 L (7.28%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.9 Cr+₹18.8 L (10.7%)Rejected-AOC | ₹1.9 Cr+₹18.8 L (10.7%) | L3 | Rejected-AOC L3 |
| 4 | L4₹2.1 Cr+₹30.6 L (17.4%)Rejected-AOC | ₹2.1 Cr+₹30.6 L (17.4%) | L4 | Rejected-AOC L4 |
| 5 | L5₹2.1 Cr+₹34.2 L (19.5%)Rejected-AOC 245 2 RAJPUR ROAD OPPOSITE HOTEL MADHUBAN DEHRADUN | ₹2.1 Cr+₹34.2 L (19.5%) | L5 | Rejected-AOC L5 |
Tender Value
₹2.6 Cr
Closing Date
24 Aug 2021, 5:00 pmClosed
Head, Electrical Division
3rd Floor, North Wing, DCSEM, V.S. Bhavan, Anushaktinagar, Mumbai-94.
Providing Street lighting and Area lighting works for Phase-II construction at GCNEP Campus site in Kheri Jassaur, Bahadurgarh, Haryana
2021_DCSEM_641651_1
DCSEM/CQD/QSC/GCNEP-II/CS/SL
Open Tender
Electrical Works
Item Rate
300 days
Kheri Jassaur, Bahadurgarh
Please refer Tender documents
8 documents required · 8 mandatory
₹0
Exempted
24 Dec 2021
4 Aug 2021
26 Aug 2021
4 Aug 2021
24 Aug 2021
16 Aug 2021
5 Aug 2021 - 11 Aug 2021
Amount
STREET LIGHT POLES : Design, manufacture, testing at works, supply, assembling, installation, and erection of Octagonal pole internally & externally hot dipped galvanised , fabricated out of 3mm thick sheet as per relevant I.S, complete with built in junction box, base plate size 200X 200 X 12 mm, as per detailed specifications. Junction box should be provided 500 mm above base plate with 4 Nos brass terminals on epoxy insulator,1 no. 6A SP MCB (D-curve) & 1 no. neutral link mounted on 4 mm thick bakelite sheet, gland plate etc. Base plate should have 4 nos holes suitable for mounting on RCC foundation 200 mm above FGL. Min 2 nos. The cost of pole shall include the cost of RCC foundation , foundation bolts, anchor plates, nuts, washers, min 2 nos. HDPE PLB pipe 40/33 mm dia bend to shape min. 1.5 m in length shall be embedded in RCC foundation for cable entry/exit etc. all as per enclosed detailed. The cost of pole shall also include the excavation of all types of soil/foot path cutting, temperory reinstatement, back filling, dewatering, consolidation disposal of excess earth within the radius of 500 m and making good to the original finish etc as per enclosed detailed specifications & drawings, as required to complete the work in all respect as per instructions of the E-I-C . Note: 1) The RCC foundation shall be as per Drg. No.DCSEM/SDS/ STD.DRG./STREET LIGHT POLE-01/8719 -R0
7m pole with 1 no. 1.5m bracket fabricated out of galvanised pipe of 40 NB medium class.
4m pole with 1no. 1.2m bracket fabricated out of galvanised pipe of 40 NB medium class.
4m pole with 2 nos. 1.2m bracket (90-180 degree) fabricated out of galvanised pipe of 40 NB medium class.
3m pole without bracket
LED luminaires for Street Lighting : Supply, Installation, testing & commissioning of following LED luminaires on existing poles, including internal wiring with 3 Core 2.5 sq.mm FRLS PVC insulated copper conductor cable from terminal box at bottom of the pole to the luminaire, earthing of luminaire etc as per instructions of the EIC. Note: 1) The scope includes providing suitable GI nipple to mount the LED luminaires on existing poles. 2) Independent wiring to be done for each fixture from terminal box. 3) No negative tolerance is allowed on the min. system performance parameters indicated in SOQ & specifications.
Street light LED luminaries having a minimum efficacy of 110 lumen/watt and a minimum output of 7000 lumens, with 4000 to 5700 degree K CCT & pressure die cast Aluminium housing, UV stabilized polycarbonate / toughened glass diffuser having IP66 & IK07 protection etc. as per specifications
Street light LED luminaries having a minimum efficacy of 110 lumen/watt and a minimum output of 3500 lumens, with 4000 to 5700 degree K CCT & pressure die cast Aluminium housing, UV stabilized polycarbonate / toughened glass diffuser having IP66 & IK07 protection etc. as per specifications
All-in-one Solar street light fixture complete with 12V, LED luminaire with min. output of 3000 lumens (min. lumen efficacy of 100 lumen/W), IP 65, 4000 to 5700 degree K CCT, MPPT Solar charge controller, Solar PV Panel, inbuilt protection & suitable lithium-ion battery for min.18 hours autonomy with dimming.
Post top LED indirect lighting type luminaries having a minimum efficacy of 100 lumen/watt and a minimum output of 3500 lumens, with 4000 to 5700 degree K CCT, having IP65 & IK07 protection etc. as per specifications.
Earthing of street light pole with 2 nos of 8 SWG G.I earth wires each 8 m long coiled in 1m dia at a depth of 1400 mm below ground level complete with soldering and connections with sockets etc all as per drawings specifications, and as per instruction of E.I.C
L.T Cables: Supply, installation, testing & commissioning of 1.1 KV grade aluminium/ Cu stranded circular/ sector shape core conductor with XLPE insulation, extruded PVC inner sheathed, G.I flat strip/wire armoured, extruded FRLS grade antirodent & anti termite PVC (ST-2)outer sheathed cable conforming to IS : 1554 Part I / IS 7098 Part-I with latest amendments, fixed on wall/existing HDPE pipe/ existing cable tray /existing hume pipe/trench/ shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles and saddles as per enclosed detailed specifications, drawings & as per instructions of the E-I-C & of the following sizes : Note: HDPE pipe shall be measured separately under item no. 7
4C x 16 Sq.mm Al. conductor cable in existing HDPE pipe
3C x 4 Sq.mm Cu. conductor cable in existing HDPE pipe
LT Cables End Joints: End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket, double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
4C x 16 Sq.mm Al. conductor cable
3C x 4 Sq.mm Cu. conductor cable
Fabricated Distribution Boards : Supply, installation, testing & commissioning of Main distribution board surface mounted type/ floor mounted with concealed hinges fabricated out of min 16 SWG thick MS CRCA sheet complete with 40 X 40 X 5mm MS angle iron frame work, supports, accessories, interconnections, earthing, locking arrangement, wire way box, cable entry box with gland & gland earthing, metal treatment (Seven tank process) painting, 2 nos 10mm dia 32 mm long brass earthing, studs, enameled danger board name plate, neoprene gasket, all required & as per instruction of E-I-C. The powder coating colour shade for MDB's shall be as follows:- 1. MDB's fed from normal power supply - RAL 9001 (White/Cream) 2. MDB's fed from DG power supply - (Emergency) - RAL 7024 (Graphite grey) Note: 1) The MCCBs shall be provided with microprocessor based overcurrent & short circuit release. 2) MCCBs shall be of minimum 36 KA Ics breaking capacity. 3) All MDBs shall be provided with RYB indication lamps (heavy duty LED cluster type) with HRC protection fuses.
Street Light Control Box: (Substation Building) Incomer :- 1. 63A FP MCCB -1 No. 2. 240 V modular astronomical digital time switch - 1 no. 3. 63A FP power contactor - 1 no. 4. 1 no. Auto/Manual switch 5. 1 set ON/OFF push button 6. 1 set ON/OFF indication lamps Bus bar 100 A TPN tinned copper bus bar having maximum current density of 1.24A/sq.mm to withstand symmetrical fault level of 35 kA at 415 V. The neutral bus bar shall have 100% capacity Outgoings :- a) 6 Nos. 25-32A FP MCB (D-curve). The feeder shall be complete with suitable size interconnection PVC FRLS Cu. wires and auxiliary contactor for contact multiplication, if required.
Readymade Distribution Board : Supply, installation, testing & commissioning of following readymade distribution boards, double door, IP 42 degree protection complete with necessary, MCBs, earth leakage circuit breaker (ELCB) etc including interconnections with appropriate capacity size of FRLS insulated copper conductor wires (ISI marked),suitable for concealed mounting /wall mounting with MS frame work of 40 x 40 x 5 mm MS angle iron, with M.S. enclosure fabricated out of M.S. CRCA sheet as per manufacturers standard, with concealed hinged door, locking arrangement etc. including earthing clamps for both incoming & outgoing circuits, interconnections, per phase isolation kit as required,cable end box & wire way box if required, continuous copper earth wire in the wire way box with single/duplicate brass earthing terminals, danger board, name plate, flexible earthing for the door, metal treatment & powder coated painting, Phase Distribution drawing etc. all as per drawings (G.A. & fabrication drawing to be got approved), etc. relevant IS & instruction of Engineer-in-charge. Note: 1.MCBs (Type –C/D) shall be minimum 10 KA breaking capacity, as specified. 2. Blanking Plates shall be included in scope of work. 3. DB shall be of standard readymade type as per catalouge No. from approved manufacturers as indicated in preferred makes of material. 4. Routine tests will be conducted at factory as per relevant IS. 5. The MCCBs shall be provided with thermal magnetic based overcurrent & short circuit release. 6. MCCBs shall be of minimum 25 KA Ics breaking capacity.
Flexi-DB- Street light DB : (SETBF & CB) 1) 63 A FP MCB -- 1 No. 2) 63A,FP, 2 NO Power contactor -- 1 no 3) 63A auxiliary changeover switch --1 No. 4) 25-32A FP MCB (D-Curve) --6 nos. 5) 8 way brass neutral link -- 3 set
Supply & laying of 50/42 mm OD/ID self lubricated HDPE pipes in ground at depth of 600 mm including excavation in all types of soil including hard rock if any cutting of existing footpath, road etc, sand bedding, laying of warning tape on top, temporary reinstatement, back filling, dewatering if necessary consolidation, disposal of excess earth with in the radius of 500 m etc. or fixed on wall/column/slab with 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/ grouted in wall/anchor fasteners 2mm thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles all as per the attached work specification and instructions of EIC. Note: 1) The scope of work includes HDPE pipe accessories such as couplers, cable end plugs, cable sealing plugs etc.
Cable Marker : Supply, installation of oval/circular shaped G.I cable marker engraved as "LT/HT Cable/HT straight through joint" complete with 32mm dia NB medium G.I pipe support as per IS 1239 with 1:2:4 PCC base concreting, G.I nut bolts, including excavation in all types of soil upto required depth and refilling etc all as per drawing, specifications and as per the instructions of E.I.C
Supply, installation of GI pipe of B class sleeves in beams/ column/slab for passing electrical cables/conduit as per instruction of E-I-C.
40 mm dia
EV Charging Points : Supply, installation, testing & commissioning of single phase 16A, 3.7kW mode1/2 charging , IP 55, IK10 metal socket for Electric vehicle charging with bracket, mounting box, similar to M/s Legrand cat no. 077856+090478+077890 fixed in existing streetlight pole junction box/ separate GI pedestal as per site condition & instructions of EIC. Note: The scope includes providing autoglo signage of 150 x 150mm with EV charging symbol on the pole junction box surface/ pedestal as per instructions of EIC.
Supply & installation of 25A, DP, 30mA Hpi RCBO in existing Feeder Pillar including providing DIN rail channel, connection with 4 sqmm Cu FRLS PVC flexible wires from existing 63A MCCB spare feeder, as per instruction of EIC.
Supply & installation of following components in existing Feeder Pillar including providing DIN rail channel, connection with 4 sqmm Cu FRLS PVC flexible wires from existing 63A MCCB spare feeder, as per instruction of EIC. a) 1 no. 63A TP contactor b) 1 no. Auto/Manual switch c)1 set 240 V modular astronomical digital time switch d) 1 set ON/OFF push button e) 1 set ON/OFF indication lamps f) 4 Nos. 25-32A FP MCB (D-curve). (for SETBF FP)
Supply & installation of 250 mm dia heavy duty RCC Hume pipe of class 'NP2' to be laid in ground/from concrete cable trench to ground, for passing of cables with necessary joints, concrete supports. Scope includes excavation below ground level in all types of soil/concrete road cutting/foot path cutting, nallah cutting /any RCC wall/floor cutting including back filling, dewatering, consolidation, reinstatement of excess earth within the radius of 500 m and original, disposal making good to the original finish etc. spare space of hume pipes after cable laying and spares hume pipes shall be sealed properly with fireproof materials.
Power and Instrumentation Guj. Ltd.
Naagar Infrastructure Pvt Ltd
Vishal Electricals
Modern Electric Company
RMS CONSTRUCTION PVT. LTD.
Highlight Associates and Contractors
HITECH ERECTORS PVT. LTD.
Konstelec Engineers Pvt. Ltd.
S.T.ELECTRICALS PVT. LTD.
EVERCREST PROJECTS PVT LTD.
Ethos Power Private Limited
S.L. ELECTROMECH PVT. LTD.
SEW ENGINEERING WORKS PVT LTD
Naresh Agarwal Constructions Pvt Ltd
RAVINDER KUMAR CONTRACTOR
sachdeva electricals
ENERGYGREEN TECHNOPOWER PVT LTD
stage.html
html • 0.10 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .