| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹11.5 L+₹40,763.70 (3.68%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹11.7 L+₹57,641.20 (5.20%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹12.3 L+₹1.2 L (10.6%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹13.1 L+₹2.0 L (18.4%)Rejected-AOC 19 AIRVIEW APARTMENT VAKOLA BRIDGE NEHRU ROAD SANTACRUZ EAST MUMBAI 400 055 | MUMBAI SUBURBAN | MAHARASHTRA | 400055 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
15 Mar 2022, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-400 088
REPAIR/MAINTENANCE OF SECURITY LIGHTS, GARDEN LIGHTS, SOLAR LIGHTS AT DOMESTIC AREA AT MANKHURD AND REPAIR/ MAINTENANCE LIGHTENING PROTECTION, LIGHTNING CONDUCTOR AND EARTHING OF BUILDING AT MANKHURD UNDER GE(NW) MANKHURD
2022_MES_508617_1
8143/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (NW) MANKHURD
₹36,000
Yes
4 Apr 2022
17 Feb 2022
16 Mar 2022
17 Feb 2022
15 Mar 2022
23 Feb 2022
17 Feb 2022 - 22 Feb 2022
Amount
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick etc complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point etc complete all as specified and directed.
M & L for sand cushioning by spreading in trenches fine crush sand by gently by punning down manually as in cable protection etc complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches etc complete all as specified and directed.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid etc complete all as specified and directed. Note :- Serviceable cable cover obtained from Ser Item No 9.00 & 10.00 here-in-after shall be reused.
Dismentling of PCC foundation / pole coping from ground level etc complete all as specified and directed.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work etc complete all as specified and directed.
Supply and Laying or fixing or passing through pipe, XLPE insulated ISI marked, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required including disconnection/taking down of existing cable etc complete all as specified and directed.
-Ditto- all as per item No 9.00 above but 10 Sqmm 4 Core etc complete all as specified and directed.
M&L for earthing complete with Copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materils
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. Note - Reinforcement and form work will be measured and paid separately.
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 12 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 10mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished surfaces of concrete, complete all as specified and directed.
Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.
Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed.
Preparing surfaces of steel tubular swaged pole LT with scraping out old paint by emmery paper, wire brush complete and painting with two coats of aluminium paint and numbering of poles with white paint on black paint background and stripping with black and yellow synthetic enamel paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete.
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black synthetic enamel paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height all as directed by Engineer in Charge.
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1616B /National/Sintax
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1010B /National/Sintax
M&L for cutting existing road/hard standing not exc 30x60 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well rammaing watering finish suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top', including removal of surplase soil all as directed.
S& F in replacement of GI steel tubing medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / PLAZA / HAVELLS
Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and remove the carbon after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. Note:- Electronic drivers and LED will be measured and paid separately on respective item of Sch 'A' here-in-after.
Supply and fix in replacement flood light fittings in buildings etc the fitting shall be of LED type 150 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make : Crompton Cat part No: LFLN-150-CDL/60/Philips/Bajaj
S&F in repair of building Security light fitting made up of pressure die cast alluminium body with mid power 60 Watt LED (PINNACLE PLUS) as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge.Make : Cat No. LST-60-CDL-M of Crompton / Havells /Bajaj
Dismantling complete old Bolard light fitting and Supply & Fix 8/9 watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3 Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry , the Fitting Shall Conform to Cat No - CONEBL8WLED857SSYMTOPC of Havells / Bajaj/Crompton
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including removing old unsv lights complete. Bajaj The fitting shalll conform to cat No - CORALPT35WLED757PSYMTOPC of Havells /Bajaj/Crompton
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including removing old unsv lights complete. The fitting shalll conform to cat No - RUBYT25WLED757PSYMTOPC of Havells or equivallent of Crompton/Polycab
Supply and fixing Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. The fitting shalll conform to cat No - LPTH-20-CDL of Crompton
S & F in repair/replacement of LED Driver 60 to 70 Watts Suitable for street light fitting etc complete all as specified and directed. Make: Crompton /Havells/Bajaj
S & F in repair/replacement of LED Driver 30 to 40 Watts Suitable for street light fitting etc complete all as specified and directed. Make : Crompton /Havells /Bajaj
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 25 to 50 Sqmm complete with testing till satisfaction of Engr-in-Charge.
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 120 to 185 Sqmm complete with testing till satisfaction of Engr-in-Charge.
S & F in repair analog time switch FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY). Make L&T
S & F in repair pole power contactor MNX-18 of coil voltage 415 Volts Make-L&T
S & F in repair spare coil for MNX-18 3 pole power contactor of 415 volts Make L&T
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
S&F GI 32x6 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in pipe, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
S&F copper 20x3 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in conuit / pipe or fixed to poles or any other indicated situation for earthing, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
M & L for depute service representative to attend the LED Solar Light fittings of 18 wattage once in a month . Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd for 26 fittings per month (a)Solar PV Modules - Check the Circuit Voltage and current characteristics. Also, check the mechanical integrity of the Solar PV Modules. (b)Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. Note:- Electrolyte solution will be measured seprately under this Schedule. (c)Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring. (d)Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed. (e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering ifa any required (f)Module Cleanliness - Cleaning of the dust accumulated over the Solar Module, and taking corrective measures
M&L for preparation of old painted surfaces of Solar Street Light Poles including acessories by scarping old paint and applying two coats of paint including numbering of pole with black synthetic enamel paint all as directed by Engineer in Charge
Supply and fix in replacement of LED 18 watt DC solar light fitting etc complete all as specified and directed. Make - Emvee / ICPC Solar
Supply and fix inreplacement of low maintenance VRLA lead acidic battery of 120 AH suitable for 1 x 18 watt Soalr Light fitting all as per recommanded by Manufracturer
Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required
Supply only electrolyte solution to be incorporated in servicing, suitable for Solar charged battery of any capacity.
M & L for Taking down of aluminium/copper strip of any size laid as roof conductor, down conductor, earth contunity conductoor including air termination rod from any position / location of sheds/ buildings of height up to 30 meter & refixing the same after straightning the conductor/removal of bends, including replacing the old insulators with new one and saddles all as directed at site Note - 1. The quoted rae is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. 2. The raete is deemed to be inclusive for providing Procealin insulator, Galvanised screws, Plugs 3. PCC Block required shall be measure and paid under respective items
S&F aluminium earth strip as roof/down/earth Contunity conductors of size 25x3mm with saddles, insulators, screws, etc to / at any position / location of sheds/ buildings of height up to 30 meter complete all as specified and directed by the Engineer-in-charge Note - 1. The quoted rate is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. 2. The rate is deemed to be inclusive of Procealin insulator, GI screws, Plugs 3. Space of insulator support shall not be more than 30 cm on roof / wall and 70 cm if insulator is placed over PCC block.
Refixing of Alluminium roof conductor/ down conductor including Air termination rod including provision of new insulator (procelain type) support, GI screw and all connected item etc complete all as specified and directed.
S&F air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary terminal base plate of not less than 3 mm, scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge
M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw in replacement of the unserviceable. Including MS box made out of 3 mm thick shheet for fixing the block
M&L for pre-cast cement concreate block of size 0.15M x0.15M x0.15M for fixing of Aluminium strip type C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the coccrete block on terrace of bldgs of height up to 30 meter all as directed at site Note 1 : The quoted rae is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. Note 2 : A sum of Rs 49,976.00 towards sch of credit shall be deducted to arrive the contract sum.
bajaranga enterprises
Shree Ayyappa Engineering
Radha Engineering Services
GAJANAN SALES CORPORATION
M/s Bhagirathi Electricals
A P ENTERPRISES
AGRAWAL ASSOCIATES
joshua construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .