CWE MHOW
HQ CWE MHOW, MHOW CANTT, MHOW (M.P)-453441
COMPREHENSIVE MAINT SERVICING OF CENTRAL TYPE AC PLANTS INSTALLED AT MH MHOW AND DET SIGNAL INF AUDITORIUM AND OTHER CONNECTED WORK UNDER GE MIS MHOW
2026_MES_798999_1
CWE/MHOW/30(T) OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
360 days
HQ CWE MHOW
Please refer Tender docs
8 documents required · 8 mandatory
₹500
GE (M) Inf School Mhow
₹44,000
16 Nov 2026
16 Nov 2026
11 Dec 2026
16 Nov 2026
9 Dec 2026
2 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive/ routine maintenance of Three Nos Chillers of 110 TR capacity having each chiller unit through OEM ,Chiller Model:- LCUX1-0425FI Make:- Blue Star , Ser No A6158A700545, A6158A700544, A6158A00530 ,AC plant installed at MH Mhow for per months including complete overhauling work through OEM complete all as specified and directed by Engg -in-charge. | 12 | Per Calender Month | - | - |
| 2 | Comprehensive/ routine maintenance of One Nos Chiller unit of capacity 25.4 TR through OEM ,Chiller Model:- XWC2S-026AR2 Make:- Blue Star , Ser No ASI00006, ASI00007, ASI00008 , AC plant installed at Det Signal Mhow for per months including complete overhauling work through OEM complete all as specified and directed by Engg -in-charge. | 12 | Per Calender Month | - | - |
| 2.02 | (vii) Contractors shall provide all kind hand tools,tester, test lamp without any extra cost as per OEM recommendations.
(viii) Checking the functioning of chiller unit/Air Handling unit/Pumps/Cooling tower/Controls and all such equipment covered under the contract.
(ix) Free replacing of defective/worn-out parts with new or repaired parts for compressor/thermostat/cut outs based on our assessment.
(x) Repairing of equipment as listed in the equipment list at site/service station as the case may be.
(xii) Descaling of condensers/chemical cleaning of evaporator coils/replacement of pre-filters based on our assessment and working parameters of the plant.
(xiii) Replenishing refrigerant gas and compressor oil in the system arising out of system defect, excluding sealed compresser.
(xiv) Checking of compressor for its proper working.
(xv) Annual pumping-down and restarting as and when required.
(xvi) Checking of Microprocessor control panel, control boards, transducers of packaged chillers/condensing unit for their correctness and replace if necessary.
(xvii) Replacing of parts due to normal wear and tear.
(xviii) OEM rep will submit service report for each plant after their visit. | - | - | - | - |
| 3 | M&L for Taking out Condenser Motor 15HP Capacity 1450 rpm 3 phase 415 volt , head-15 mtr, Discharge- 160 cum/H, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end , non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa | 2 | Each Job | - | - |
| 4 | M&L for Taking out Chiller Plant Monoblock type Motor 15 HP Capacity 2900 rpm 3 phase 415 volt , discharge-14 LPS, Head-26 mtr, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa | 2 | Each Job | - | - |
| 5 | M&L for taking out Chiller Plant Monoblock type Motor 7.5 HP Capacity 2880 rpm 3 phase 415 volt , discharge-26 LPS, Head- 31 mtr, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa | 2 | Each Job | - | - |
| 6 | Material and Labour for cleaning, servicing, overhauling to all component of AHU for various CFM with and including replacement of all old fins, cleaning of heating & cooling coil with caustic soda solution, including welding / brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom tray of existing size with drain pane made out of 16 guage thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nut, bolt, washer and other packing material etc, with and including testing, commissioning of Air handling Unit at optimum efficiency, complete all as specified and directed by Engineer -in-charge. | 6 | Each Job | - | - |
| 7 | S&F in replacement AHU belt as per existing Size and model complete all as specified and directed by Engineer-in-charge. | 8 | Each Job | - | - |
| 8 | M&L for taking out Cooling Tower Motor 5HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including,bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and from transportation for workshop and vice versa | 2 | Each Job | - | - |
| 9 | Material & Labour for repairing of hot water pump cap 5kw 3 phase, overhauling and replacing bearings and mechanical seal complete all as specified and directed. | 2 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_896389.xls
BOQ • 5.04 MB
Credit30T.pdf
Tender Documents • 0.10 MB
GENPAGES30T.pdf
Tender Documents • 0.82 MB
PS30T.pdf
Tender Documents • 0.56 MB
SpecialCondition30T.pdf
Tender Documents • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .