Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC ACCEPTED FOR L1 | |
| 2 | L2₹54.9 L+₹9.5 L (21.0%)Accepted-AOC | L2 | Accepted-AOC REJECTED FOR L2 | |
| 3 | L3₹58.5 L+₹13.1 L (28.7%)Accepted-AOC | L3 | Accepted-AOC REJECTED FOR L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical The firm change in constitution in UE |
Tender Value
₹54.2 L
EMD Value
₹1.1 L
Closing Date
6 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-90 OF 2020-21 PROVISION OF COVID RELATED INFRASTRUCTURE UNDER PARA 35 OF DWP 2020 AT 173 MH IN MILITARY STATION FARIDKOT
2021_MES_426800_1
CA NO. CWE SGNR - 90 OF 2020-21
Open Tender
Civil Works - Others
Item Rate
90 days
GE FARIDKOT
Class C
Category a(i) and c(i)
9 documents required · 9 mandatory
₹1,000
Yes
GE FARIDKOT
₹1.1 L
Yes
10 Apr 2021
2 Mar 2021
8 Apr 2021
2 Mar 2021
6 Apr 2021
22 Mar 2021
60 days
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L RCC 1:1 ½:3 type A1 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases beams; under-reamed piles slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L RCC (1:1½:3) type A1 using (20mm gradded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m , lintel bend complete all as specified and directed by Engineer-in-Charge.
M&L RCC (1:1½:3) type A1 using (20mm gradded aggregate) in column complete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:1½:3 A1 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies and in shelves complete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:1½:3 A1 (20mm graded aggregate) in chajjas all as specified complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits of foundation and plinth beam and similar wk vertical or to batter complete all as specified and directed by Engineer-in-Charge.
Form work to sides and soffits of floor or roof beam, beam, hauchings, girders, bressum-emers, lintels, cantilevers, shelves incl supports overhangs etc also splays between floors and beams complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of pillars, posts, struts, piers, columns complete all as specified and directed by Engineer-in-Charge.
Formwork to chajjas, troughs and similar items including edges complete all as specified and directed by Engineer-in-Charge.
S&F MS TMT Bars of 10 mm dia and over,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer-in-Charge.
S&F MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders,cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks (old size bricks) straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified.
M&L Brick work with old size sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L ATT Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Engineer-in-Charge.
M&L ATT Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer-in-Charge.
M&L ATT Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed by Engineer-in-Charge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as specified and directed by Engineer-in-Charge.
S&F Mild steel box type ventilator fixed type complete with sash bars dovetailed or welded and with shop coat of zinc chromate primer ready for wire mesh/glass pan fixing complete all as specified and directed by Engineer-in-Charge.
M&L mild steel framed work of Fe-290 (Gde E-165) as in grills/guard bars shouldered with steel windows/ventilators frames. Cooler stand, ladder etc including redoxide primer coat complete all as specified and directed by Engineer-in-Charge.
S&F 3mm th glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engr-inCharge.
S & F steel rolling shutters, 1.25mm thick, without ball bearing, as specifed and including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete, gear operated type with bevel gear box and crank handle. all as specified and directed by Engineer in Charge.
S & F steel ball bearing for fixing of steel rolling shutter complete all as specified and directed by Engineer-in-Charge.
S&F safety lever locks mild steel with 4 lever for rolling whutters complete all as specified and directed by Engineer in Charge. Note: Rate includes necessary arrangement for fixing with new rolling shutter and making good in operating condtion.
Hardcore of broken stone boulders gauge not exceeding 63mm deposited spread and leveled in layers not exceeding 15 Cm thick watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Polythene film, black, 50micron laid in floors complete all as specified and directed by Engineer-in-Charge.
M&L 75 mm thick PCC 1:4:8 type D-2 (Using 40 mm graded aggregate), as in flooring complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed by Engr -in - charge.
Machine cut kota stone slab in flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 15mm thick screed bed or bedding layer CM 1:4 for laying finishes complete all as specified and directed by Engineer-in-Charge.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Finishing surface of concrete by belting or making chequred finish complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 50mm thick type C2, 1:3:6 using 20mm graded aggregate as in plinth protection/path finishing surfaces even and fair (without using extra cement) complete all as specified and directed by Engineer-in-Charge.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified and directed by Engineer-in-Charge.Note. (Payment for providing grooves shall be made separately).
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per pecifications and direction of the Engineer-in-charge
M&L Preparation of new surfaces plastered or unplastered and applying two coat of white wash over one coat of primer on wall complete all as specified and directed by Engr -in - charge.
M&L Preparation of new ceiling surfaces plastered or unplastered and applying two coat of white wash complete all as specified and directed by Engr -in - charge.
M&L preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Surface Excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thickcement concerete type D-2, 1:4:8 using 40 mm graded stone aggregates complete all as specified and directed by Engineer-in-Charge.
M&L coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, with grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
Providing factory made precast cement concrete solid block type B1, 1:2:4 (20mm graded aggregate) as in kerb stone of any size/thickness setting in cement mortar 1:4 for path edgings etc, embedded in positon including all necessary excavation, tamping ground arround blocks and removal of rubbish/surplus soil complete all as specified and directed by Engineer-in-Charge.
M&L for providing cement concrete type C1 (1:3:6) using 20mm aggregate, as in coping, kneelers, apex stones, bed plates, kerbs etc. and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
Preparation of new concrete surfaces of any description, over 10cm width or girth and applying two coats of plastic emulsion paint including priming paints complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 10 mm thick in cement plaster 1:4 with WPC on roof, fair faces of brick work or concrete surfaces all as specified and directed by Engr -in - charge. Note : WPC will be measured and paid separately
M&L for Roof Treatment as specified below and complete all as specified and directed by Engineer-in-Charge. (a) Cleaning, washing of surface and removing all existing bitumen coatings completely with intense wire brushing or high speed water jet. Surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal/ Epoxy Primer/ShaliUret:-ane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm (0.20 kg BTD+0.20 Kg water) (d) Laying polyster reinforced fiber net/50 gsm Geotextile mesh, upto 300 mm on walls. (e) Applying three coat of HydroShield PUD microfibre reinforced UV resistent polyurethane (solid content 68% ) / Damp Proof ultra UV Stable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers (Solid content 55%)/ SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%)/Single Component Elastomeric Liquid Membrane ShaliUrethane BTD White/coloured (Elongation 400% ± 50, Solid Contents > 80% & Specific Gravity @ 30 OC 1.5 ± 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (f) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge. (ii) The plan area of floor shall be considered for payment
Supply only Integral waterproofing compound complete all as specified and directed by Engineer-in-Charge.
M & L for concealed conduit point wiring complete for light on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes 60mm deep ,suitable length and 1. 2 mm thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No -56 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No -56 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 56 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 4 Sqmm complete all as specified and directed by Engineer-in-Charge.
S & F switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S & F switch socket combination 6 Pin, 15/16 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S & F ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified and directed by Engineer-in-Charge.
S & F Switch piano, flush type, single pole, one way, 5 Amp complete all as specified and directed by Engineer-in-Charge.
S & F of LED tube light fitting 20 Watt (4 feet long) 230 V, surface and Wall mounted LED Batten with polycarbonate housing & intergrated electronic driver and including connections up with copper conductor wire with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch Belll Push flush type single pole complete all as specified and directed by Engineer-in-Charge.
Supply and fix Electric bell Ding-Dong type single phase 230 volts & senser based to locate indigation of bed Number complete all as specified and directed by Engineer-in-Charge.
S & F exhaust fans AC single Phase 230/240 V of size 300 mm sweep with louver complete all as specified and directed by Engineer-in-Charge.
S&F Automatic Hand Drayer Machine complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in PVC conduict including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer-in-Charge.
Supply and fix SP&N DBs, double door, 240 volt, 8 way complete all as specified and directed by Engineer-in-Charge.
S & F Distribution board, VTPN, 4 way, vertical type, double door, 415 volts with provision for DPX 125 MCCB as incommer and SP/TP MCB as outgoing and electrically connecting up complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCCBs,125 Amps, 16 KA, 3 pole with adjustable thermal & magnetic settings complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCCBs,100 Amps, 16 KA, 3 pole with adjustable thermal & magnetic settings complete all as specified and directed by Engineer-in-Charge.
M&L for MCB single pole, 240 volts, 6 - 40 Amps, 10 KA complete all as specified and directed by Engineer-in-Charge.
M&L for MCB single pole & neutral 240 volts 63 Amps complete all as specified and directed by Engineer-in-Charge.
M&L for MCB blanking plate complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed by Engineer-in-Charge.
M&L for river sand, washed and screened dry for cushioning to underground cable in trenches below and around underground cable including spreading and levelling complete all as specified and directed by Engineer-in-Charge.
M&L for laying well burnt old size bricks, sub class 'B' bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified and directed by Engineer-in-Charge.
Boring / Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing Galvanised mild steel pipe / tubing, of size 80 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 82 here-in-before but for size 40 mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing testing and commissioning LT under ground electric cable, crossed linked polythelene (XLPE) insulated, galvanised steel strip or wire armoured, IS-7098 marked with aluminium conductor mult stranded, heavy duty 1100 volts grade of size 10 Sqmm cross sectional area 4 Core, laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note : Excavation and earth work and sand coushing, brick protection of pipes shall be measured and paid separately under relevant item of this BOQ.
All as per item No 84 above but LT cable of cross sectional area 16 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
All as per item No 84 above but LT cable of cross sectional area 50 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per item No 84 above but LT cable of cross sectional area 95 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
All as per item No 84 above but LT cable of cross sectional area 120 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engr-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement shall be 1 kg for each earth pit cover
Supply, installation, testing commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by card lean and kay locking arragement front & back, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The TPN busbar shall be insulated with colour coaded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of theTPN busbar. The cubicle incomer MCCB as well as outgoing shall have aluminium TPN extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300 mm long supported on suitable size "F" class insulator. All inter connections between the main busbar as well as outgoing feeder shall be carried out with TPN aluminium busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves.comprising , Including taking down old unsv panel any size of the following:- INCOMING (a) MCCB 4 pole, 415 V, Thermal Magnetic Release Manual Draw out type of capacity 400 Amps, 36 KA - 01 No. (INCOMERI) OUTGOING (b) MCCB 4 Pole, 36 KA, 320 Amps - 01 No. (COVID 19 Ward No. 01) (18 Beds) (c) MCCB 4 Pole, 36 KA, 200 Amps - 01 No. (Surgical Ward) (d) MCCB 4 Pole, 25 KA, 100 Amps - 01 No. (Surgical Ward) x (01 Spare) (e) MCCB 4 Pole, 25 KA, 63 Amps - 01 No.
S&F in repair MCCB, 3 phase 4 pole, 415 volt of capacity 500 Amp, 50 Hz, short circuit, breaking capacity not less than 36 KA , with fixed thermal and fixed magnetic setting including thimbles, nuts, bolts ,washers etc complete all as specified and directed by Engineer-in-charge
OXYGEN MANIFOLD (AKTIV) 6 + 6 cylinders OXYGEN Manifold Bank complete with high pressure copper tubing, NRV’s, Flexible tail pipes, etc complete all as specified and directed by Engineer-in-Charge.
Automatic Control Panel (AKTIV) complete all as specified and directed by Engineer-in-Charge.
EMERGENCY MANIFOLD (AKTIV) 2 cylinders OXYGEN Manifold Bank complete with high pressure copper tubing, NRV’s, Flexible tail pipes, with Regulator , etc complete all as specified and directed by Engineer-in-Charge.
NITROUS OXIDE SYSTEM (AKTIV) 2 cylinders NITROUS OXIDE Regulation System complete all as specified and directed by Engineer-in-Charge.
SUCTION SYSTEM: 5 H P (DUPLEX SYSTEM) Suction Pump, single stage , two cylinder, Air Cooled , Motor (ABB) and DOL Starter (L & T) with Tank mounted , 300 litres Reservoir 3 mm thickness, complete with Switch, Starter, Automatic Pressure switch, NRV, Interconnecting pipes, etc complete in all aspects complete all as specified and directed by Engineer-in-Charge.
AIR SYSTEM 5 H P (DUPLEX SYSTEM) Air Compressor Air Cooled , Motor (ABB) and DOL Starter (L & T) with Tank mounted , 300 litres Reservoir 3 mm thickness, complete with Switch, Starter, Automatic Pressure switch, with Drier 20 cfm, Air Filter .01 microns , Control Panel , Interconnecting pipes, etc complete in all aspects complete all as specified and directed by Engineer-in-Charge.
COPPER TUBINGS: (JANYA EXTRUSIONS) DHP Copper Tube and Fittings as per specifications: EN : 13348, 28mm OD x 0.9mm wall thickness complete all as specified and directed by Engineer-in-Charge.
DHP Copper Tube and Fittings as per specifications: EN : 13348, 22mm OD x 0.9mm wall thickness complete all as specified and directed by Engineer-in-Charge.
DHP Copper Tube and Fittings as per specifications: EN : 13348, 15mm OD x 0.9mm wall thickness complete all as specified and directed by Engineer-in-Charge.
OUTLET POINTS Double Locking, Front Loaded Medical Gas Outlet Points as per DIN / BS Standards for OXYGEN complete all as specified and directed by Engineer-in-Charge.
Double Locking, Front Loaded Medical Gas Outlet Points as per DIN / BS Standards for VACUUM complete all as specified and directed by Engineer-in-Charge.
Double Locking, Front Loaded Medical Gas Outlet Points as per DIN / BS Standards for COMPRESSED AIR complete all as specified and directed by Engineer-in-Charge.
SUCTION TROLLEY Theatre Suction Trolley with 2 nos of Jars's 2000 ml each , Suction Regulator , Control Valve , Tubings, etc complete all as specified and directed by Engineer-in-Charge.
CEILING PENDENT Swivel Pendant horizontal movement of 320 degrees, comprising of Double shelf, 2 I V Hangers , 4 Mains Socket .Provision for 8 Medical Gas Terminal & Hose Assembly One Set (Medical Gas point i.e O2 -2nos, Vac- 2nos, Air 2 and Nitrous Oxide - 2 complete all as specified and directed by Engineer-in-Charge.
BED HEAD PANELS Extruded Aluminium , 2 mm thickness, double railing having provision for Gas Outlet & Electricals: 4 feet in length complete all as specified and directed by Engineer-in-Charge.
Electrical 20 amps / 10 amps : 2 switches + 2 sockets in one plate complete all as specified and directed by Engineer-in-Charge
AREA ALARMS (DIGITAL) (AKTIV)Three Gas for OXYGEN, SUCTION , AIR complete all as specified and directed by Engineer-in-Charge.
ISOLATION VALVES 15mm complete all as specified and directed by Engineer-in-Charge.
ISOLATION VALVES 22mm complete all as specified and directed by Engineer-in-Charge.
OXYGEN FLOW METERS BPC Oxygen Flowmeter of range 0-15 Ltrs per minute of Brass Body with polycarbonate Humidifier Bottle complete all as specified and directed by Engineer-in-Charge.
WARD VACUUM UNITS 600ml Polycarbonate Suction Jars and Regulators with tubings complete all as specified and directed by Engineer-in-Charge.
M/s Balvinder Singh Engineer and Contractors
M/s Kataria Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .