Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹26.4 LAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹26.4 L | l1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹27.3 L+₹89,981 (3.40%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹27.3 L+₹89,981 (3.40%) | L2 | Rejected-Finance Being NOT Lowest |
| 3 | L3₹28.6 L+₹2.2 L (8.19%)Rejected-Finance | ₹28.6 L+₹2.2 L (8.19%) | L3 | Rejected-Finance Being NOT Lowest |
| 4 | L4₹29.1 L+₹2.7 L (10.0%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹29.1 L+₹2.7 L (10.0%) | L4 | Rejected-Finance Being NOT Lowest |
| 5 | L5₹29.5 L+₹3.0 L (11.5%)Rejected-Finance | ₹29.5 L+₹3.0 L (11.5%) | L5 | Rejected-Finance Being NOT Lowest |
Tender Value
₹41.6 L
EMD Value
₹83,300
Closing Date
5 Jun 2021, 6:00 pmClosed
SHRI ARJUN PATRO,IDSE
GE(U) ELECTRIC SUPPLY,DELHI CANTT-10
MANNING AND OPERATION OF RECEIVING AND DISTRIBUTION SUBSTATIONS REPAIR MAINTENANCE TO LT DISTRIBUTION PANELS AND CONNECTED WORKS AT CVD CHITRA LINE SUB STATION, PIRU VIHAR DIPAC HQ TGKOTWALI SUB STATION AND ASSOCIATED AREA OF AGE U ES NO I UNDER G
2021_MES_443259_1
GE ELECT/D-24/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE(U) ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(U)ELECTRIC SUPPLY
₹83,300
Yes
16 Jun 2021
17 May 2021
7 Jun 2021
18 May 2021
5 Jun 2021
31 May 2021
Amount
Maintanance services to be provided for 11 KV CVD Chitral line Sub station as per details as under (a) The installation is main receiving sub station and complaint center minimum 01 electrician shall be provided (per shift) around the clock (24 x 7) . the electrician shall have adequate knowledge of above maintioned job and GE/Engr-in-charge can reject the proposed electrician giving reasoned rejection. No claim shall be admissible on account of rejection of person. (b) Details of equipment :- Transformer step down 11 KV/0.433 KV of capacity 630 KVA capacity -4 Nos, 250 KVA - 01 No, 11 KV 4 pole structure - 01 No, 11 KV VCB - 17 Nos, Battery Bank - 01 No, LT Panel - 05 Nos and Capacitor Panel - 02 Nos (c) The following checking, testing, supervision shall be carried out by electrician in respect of equipments mentioned at para (b) above:- (i) Recording of all parameters of system as per indication of all equipments installed in the log sheet as directed by ngr-in-charge round the clock on daily basis. (ii) Maintainance of fault register (iii) Maintainance of shutdown register (iv) Proper operation of 11 KV Breaker (v) Giving of Shutdown by draw out of trolley of breaker (vi) Proper operation of 11 KV GO DO. (vii) Fixing of burnt out fuse on GO of 11 KV 4/6/8/10 pole structure. (viii) Checking of LED indication for breaker ON, OFF, Trip, Spriing charge, trip circuit heakthy on daily basis. (ix) Checking of annunciatore, hooter, indicators, meters, TNC switch, emergency trip push button, MCB for AC DC isolation,heater, thermostate on daily basis (x) Checking of status of Main protection numerical relay Auxillary protection relays such as trip circuit supervision relay(xi) Attending of all complaint of the Sub station area. (xii) Cleaning of dust & foreign particles on and around the panel, loose connection earthing connection in the sub station. (xiii) Testing of earth resistance of all earthing as directed by Engr-in-charge. (xiv) Checking of DC voltage of system as directed by Engr-in-charge.
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day per shift (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 1.02 to 1.05 as applicable.
LWC as per existing rules on total of srl no 1.02 to 1.06. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 1.02 to 1.06 are exclusive of GST for calculating of labour cess. Refer Sch 'A'Note No 33 (e) on Page No 17 of Tender Document.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC, BONUS and LWC under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.
(d) Contractor is required to quote upto two digits after decimal place or otherwise it will be consdered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) Any variation in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’
Maintanance services to be provided for 11 KV Piru Vihar Sub station as per details as under (a) The installation is main receiving sub station and complaint center minimum 01 electrician shall be provided (per shift) around the clock (24 x 7) . the electrician shall have adequate knowledge of above maintioned job and GE/Engr-in-charge can reject the proposed electriciangiving reasoned rejection. No claim shall be admissible on account of rejection of person. (b) Details of equipment :- Transformer step down 11 KV/0.433 KV of capacity 630 KVA capacity -4 Nos, 750 KVA - 01 No, 11 KV 4 pole structure - 01 No, 11 KV VCB - 09 Nos, Battery Bank - 01 No, LT Panel - 05 Nos and Capacitor Panel - 02 Nos (c) The following checking, testing, supervision shall be carried out by electrician in respect of equipments mentioned at para (b) above:- . (i) Recording of allparameters of system as per indication of all equipments installed in the log sheet as directed by ngr-in-charge round the clock on daily basis. (ii) Maintainance of fault register (iii) Maintainance of shutdown register (iv) Proper operation of 11 KV Breaker (v) Giving of Shutdown by draw out of trolley of breaker. (vi) Proper operation of 11 KV GO DO. (vii) Fixing of burnt out fuse on GO of 11 KV 4/6/8/10 pole structure. (viii) Checking of LED indication for breaker ON, OFF, Trip, Spriing charge, trip circuit healthy on daily basis. (ix) Checking of annunciatore, hooter, indicators, meters, TNC switch, emergency trip push button, MCB for AC DC isolation,heater, thermostate on daily basis (x) Checking of status of Main protection numerical relay Auxillary protection relays such as trip circuit supervision relay (xi) Attending of all complaint of the Sub station area. (xii) Cleaning of dust & foreign particles on and around the panel, loose connection earthing connection in the sub station. (xiii) Testing of earth resistance of all earthing as directed by Engr-in-charge. (xiv) Checking of DC voltage of system as directed by Engr-in-charge.
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day per shift (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 2.02 to 2.05 as applicable.
LWC as per existing rules on total of srl no 2.02 to 2.06 as applicable. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 2.02 to 2.06 are exclusive of GST for calculating of labour cess. Refer Sch 'A'Note No 33 (e) on Page No 17 of Tender Document.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC, BONUS and LWC under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.
(d) Contractor is required to quote upto two digits after decimal place or otherwise it will be consdered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) Any variation in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’
Supply, install, test and commissioning in replacement of factory made tested LT panel board of size not less than 1.9 mtr x 0.6 mtr x1.5 mtr cubical double door compartment outdoor type floor mounted on Medium Channel 75/40 mm suitable for , 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bar of rating not less than 1.5 times of incoming/ outgoing ACB/MCCBs installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 2.0 mm, 40 X 40 X 6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 2.5 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:-
INCOMING:- (i) MCCB 4 pole, 400 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 1 Nos (ii) Voltmeter digital type - 01 No (iii) Ammeter digital type - 01 No (iv) CT ratio 400/5 Amp class-1 ISI marked - 01 Set of three (v) Indicating LED lamp one set of three
OUTGOINGS:- (i) MCCB 4 pole, 63-100 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermal and Adjustable Magnetic setting- 7 Nos (ii) MCCB 4 pole, 63 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermal and Fixed Magnetic setting - 1 No Location :- (i) Basantar Line
All as item no-3.00 above (here in before) but as followings:- Panel Size should not be less than 1.5 mtr x 0.6 mtr x 1.5 mtr.
INCOMING:- (i) MCCB 4 pole, 320 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 1 Nos (ii) Trivector Meter ,Model ER300P, Base mounting , 3 Ph, 4W TVM 240V (L-N) 5A Class 0.5 BM, with CT. Make -L&T or equivalent (iii) CT ratio 250/5 Amp class-1 ISI marked - 01 Set of three
OUTGOINGS:- (i) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermal and Fixed Magnetic setting-2 No (ii) MCCB 4 pole, 63 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermal and Fixed Magnetic setting-3 No Location :- HQ TG (Offr Mess)
All as item no-3.00 above (here in before) but as followings:- Panel Size should not be less than 0.8 mtr x 0.5 mtr x 1.5 mtr
INCOMING:- (i) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermal and Adjustable Magnetic setting- 1 Nos (ii) CT ratio 250/5 Amp class-1 ISI marked - 01 Set of three OUTGOINGS:- (i) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermo and Fixed Magnetic setting-3 No Location :- Near HQ TG EME
All as item no-3.00 above (here in before) but as followings:-
Panel Size should not be less than 1.35mtr x 1.1 mtrx 0.44 mtr INCOMING:- (i) MCCB 4 pole 400 Amps thermal magnetic releases 50 Hz 415 Volts 35 KA -1 No (ii) CT ratio 400/5 Amp class-1 ISI marked - 01 Set of three
OUTGOINGS:- (i) MCCB 4 pole, 200 Amps, thermal magnetic releases, 50 Hz, 415 Volts, 25 KA - 1 No (ii) MCCB 4 pole, 100 Amps, thermal magnetic releases, 50 Hz, 415 Volts, 25 KA - 4 No Location :- DIPAC
Note for item No- 3 to 7:- (i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimbles. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel paint/ Flourcent refelctive lettring . (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. (iv) Costruction of Foundation & taking out of the old UNSV LT Panel with connected cables and reconnection of the cables with new thimbles ,gland of suitable size after installation of new panel are deemed to the above quoted rate.
M&L in replacement Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized strip 32 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised iron side complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in soft/loose soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 type C2 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement 6mm dia both ways as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade any size PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098, Part-II marked, laid in trenches/ duct/ under road/ footpath/ etc complete all as specified and directed. Cables of the following size
400 sqmm 3.5 core
240 Sqmm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
25 sqmm 3.5 core
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/losse soil) for laying of cables or GI pipe and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement battery bank comprising 02 Nos of 12 Volts-100 AH, 24 volt sealed maintenance free battery.
S&F in replacement of change over switch 400 Amps OFF load (side handle) in sheet enclosure four pole to be fixed on wall , nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
Material and labour for shifting of LT panel from one site to another site including necessary Foundation , reconnection of LT cables (incoming/outgoing) as directed by Engr In Charge.
Note : (i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
M/s Adhikari construction co.
Rajindera Enterprises
V r traders
Garg Engineers
Ridhi engineers and builders
Buddham Builders
MV Engineers And Contractors
RUHI ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .