SPECIAL REPAIR REPLACEMENT OF OLD FLAME PROOF LIGHTS AT VARIOUS LOCATIONS AT AT STN SIRSA
2022_MES_531846_1
GE/SRA/T-16 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
364 days
GE (AF) SIRSA
As per NIT and Tender Documents
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹7.5 L
Yes
15 Sept 2022
18 Jun 2022
29 Jul 2022
18 Jun 2022
26 Jul 2022
1 Jul 2022
18 Jun 2022 - 25 Jun 2022
Amount
Taking down carefully Aluminium/copper point wiring(light,socket,power)complete (fittings) such as sockets,ceiling roses,pendants,regilators,switches,etc and making good disturbed surfaces and complete all as specified and directed by Engineer-in-Charge.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, and complete all as specified and directed by Engineer-in-Charge.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including ERW Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
S&F in repairs LED Flameproof weather proof fittings in IP-66 construction with 1x20 W certified by CMRI dhanbad and complete all as specified and directed by Engineer-in-Charge. Note. (i) Contractor/Vendor will submit the test certificate for flame proof LED Light by the any approved NABL accredited LAB before incorporation of the work . (ii) Contractor will submit certificate for LM-79/80 for Flame Proof LED Light before incorporation in the work. (iii) Contractor will submit the guarantee/warranty certificate of two years after completion of work.
S&F in repairs LED Flameproof weather proof fittings in IP-66 construction with 2x20 W certified by CMRI dhanbad and complete all as specified and directed by Engineer-in-Charge. Note. (i) Contractor/Vendor will submit the test certificate for flame proof LED Light by the any approved NABL accredited LAB before incorporation of the work . (ii) Contractor will submit certificate for LM-79/80 for Flame Proof LED Light before incorporation in the work. (iii) Contractor will submit the guarantee/warranty certificate of two years after completion of work.
S&F in repairs LED Flameproof weather proof highbay light fittings in IP-66 construction with 1x100 W certified by CMRI dhanbad and complete all as specified and directed by Engineer-in-Charge. Note. (i) Contractor/Vendor will submit the test certificate for flame proof LED Light by the any approved NABL accredited LAB before incorporation of the work . (ii) Contractor will submit certificate for LM-79/80 for Flame Proof LED Light before incorporation in the work. (iii) Contractor will submit the guarantee/warranty certificate of two years after completion of work.
S&F in repairs LED Flameproof weather proof flood light fittings in IP-66 construction with 1x100 W certified by CMRI dhanbad and complete all as specified and directed by Engineer-in-Charge. Note. (i) Contractor/Vendor will submit the test certificate for flame proof LED Light by the any approved NABL accredited LAB before incorporation of the work . (ii) Contractor will submit certificate for LM-79/80 for Flame Proof LED Light before incorporation in the work. (iii) Contractor will submit the guarantee/warranty certificate of two years after completion of work.
S&F in repairs LED Flood light fitting made up of pressure die cast alluminium housing with toughned glass and high power 45 W LED IP-66 Protection and complete all as specified and directed by Engineer-in-Charge.
Supply,laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire aromured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core and complete all as specified and directed by Engineer-in-Charge.
S&F submain wiring in ERW conduict with two single core 2.5 Sqmm PVC insulated,unsheathed sttranded copper FRLSH conductor drawn in and including stove enameled ERW steel conduict 20 mm including 1.5 Sqmm copper stranded conductor PVC insulated FRLSH earth wire connected to main board and complete all as specified and directed by Engineer-in-Charge.
S&F in repairs flameproof weather proof MCB DB in cast alluminium alloy LM6 construction DB TPN-4 Way with cable termination chamber all cable entries from bottom external operating knob incomer 100 A MCCB-01 No and outgoing 02 Nos TPN MCB 32 A and MCB SP-20 Nos certified by CMRI dhanbad with cable glands suitable for hazardous area and confirming to IS and degree of protection IP65 and complete all as specified and directed by Engineer-in-Charge.
S&F in repairs flameproof weather proof MCB DB in cast alluminium alloy LM6 construction DB SPN 8 Way with cable termination chamber all cable entries from bottom external operating knob incomer 32 A SPN MCB-1 No and outgoing 06 Nos SP MCB 32 A certified by CMRI dhanbad with cable glands suitable for hazardous area anf confirming to IS and degree of protection IP65 and complete all as specified and directed by Engineer-in-Charge.
M&L of XLPE insulated armoured heavy duty electric cable fixing with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 2 core and complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exc 1.5m wide out next 1.5m in depth for laying/taking out of cable and getting out soil including the side and forming bottom surface to required level complete all as specified and complete all as specified and directed by Engineer-in-Charge.
Removal of surplus spoils soil to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 Mtr above the starting point all as specified & directed by Engr-in-Charge.
Returning filling soft/loose soil including spreading, leveling watering and well ramming in layers next. 25cm thick in layers complete all as specified and directed by Engineer-in-Charge.
Supply and lay in trenches burnt class ‘B’ bricks for cable protection all as specified and complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable and complete all as specified and directed by Engineer-in-Charge.
Making Hole under road/hardstanding including cutting etc with manual anger or bookie n.exc 100 mm dia and complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of galvanised steel tubing pipe 50 mm bore light grade with bend laid in trenches or under roads/walls/flooring/culverts and/or fixing to electric poles including repair work required as per existing with suitable size mild steel flat iron clamps,bolts,nuts,washers etc and complete all as specified and directed by Engineer-in-Charge.
All as per item no 18 here-in-before but of size 80 mm and complete all as specified and directed by Engineer-in-Charge.
NISHTHA BUILDERS
BHATIA ENTERPRISES
YOGINDER KUMAR GUPTA AND COMPANY
RAGHAV ELECTRICALS
Aman Enterprises
M/s Shree Bala Ji Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .