| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAccepted-AOC 93 SRP KOVIL STREET PERAVALLUR CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹52.3 L+₹2.4 L (4.71%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹52.4 L+₹2.5 L (5.08%)Rejected-Finance 2 755 ELAIYATHAMMAN KOIL MAIN ROAD BHARADHI NAGAR PTMS IAF POST AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹52.9 L+₹3.0 L (6.10%)Rejected-Finance OLD NO 191 NEW NO 616 M T H ROAD PATTABIRAM CHENNAI 600 072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹53.3 L+₹3.4 L (6.91%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Mariammal Constructions L8 | G HARI ELECTRICALS L3 | JANANIKARTHIK ENTERPRISES L1 | SUBAMAGENCYANDCONSTRUCTION L4 | Shri Varaghaa L7 | SAMYDOSS CONSTRUCTIONS L2 | M/s Omm Muruga Enterprises L5 | pmv.enterprises L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00PART -I - SPECIAL REPAIR TO REPLACEMENT OF COOLING APPLIANCES AGAINST BER AND CONNECTED ITEM AT ARMY AREA | |||||||||||
| 2.00 | Disconnecting electric supply from source, taking down window type air conditioner of any capacity along with voltage stabilizer, without causing damage to connected wiring and other existing installations, including making good disturbed surfaces to match existing finish, complete in all respects, including stacking at MES Store Yard, GE Avadi, complete, all as specified and as directed. | 2 | Each Job | 425 ₹850 | 179 ₹358 Lowest | 499 ₹998 | 330 ₹660 | 250 ₹500 | 500 ₹1,000 | 400 ₹800 | 650 ₹1,300 |
| 3.00 | Supply, installation, testing and commissioning of Hi-Wall Split Type Air Conditioner of 1.5 TR capacity (5 Star rated) having minimum EER 3.2, complete with indoor and outdoor units, cordless remote control, in-built ioniser and plasma filter, copper condenser coil, including copper refrigerant tubing set (1/4" and 1/2") of required length with PUF insulation, 15 mm dia flexible PVC drain pipe with clamps( 6 Rm), GI powder coated brackets (16 SWG) for outdoor unit with suitable fasteners and grouting, power and control cabling, earthing, mounting arrangements and all connected accessories, complete in all respects, all as specified and as directed. | 2 | Each Job | 49,560 ₹99,120 | 59,990 ₹1,19,980 | 49,000 ₹98,000 Lowest | 53,500 ₹1,07,000 | 75,000 ₹1,50,000 | 57,500 ₹1,15,000 | 65,000 ₹1,30,000 | 58,750 ₹1,17,500 |
| 4.00 | Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input varition between 90V to 260V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 4KVA complete all as specified and as directed. | 2 | Each | 5,300 ₹10,600 | 5,200 ₹10,400 | 5,000 ₹10,000 | 4,250 ₹8,500 Lowest | 9,200 ₹18,400 | 4,500 ₹9,000 | 5,000 ₹10,000 | 4,850 ₹9,700 |
| 5.00 | Supply and fix copper tubing set 1/4" and 1/2" suitable for Split AC including PUF insulation and connected accessories, fixcing for outdoor unit for user requirement complete all as directed by eng-in-charge | 12 | Running Meter | 1,200 ₹14,400 | 1,200 ₹14,400 | 950 ₹11,400 | 650 ₹7,800 Lowest | 990 ₹11,880 | 700 ₹8,400 | 950 ₹11,400 | 775 ₹9,300 |
| 6.00 | Supply &Fix for Sub main wiring with 2x 4 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in to and including PVC conduit and conduit accessories , including 4.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed. | 350 | Running Meter | 330 ₹1,15,500 | 325 ₹1,13,750 | 300 ₹1,05,000 | 290 ₹1,01,500 | 375 ₹1,31,250 | 250 ₹87,500 Lowest | 250 ₹87,500 Lowest | 285 ₹99,750 |
| 7.00 | Supply & fixing in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed. | 20 | Each | 1,275 ₹25,500 | 990 ₹19,800 Lowest | 1,200 ₹24,000 | 1,150 ₹23,000 | 1,100 ₹22,000 | 1,500 ₹30,000 | 1,300 ₹26,000 | 1,350 ₹27,000 |
| 8.00 | Material and labour for providing and fixing plywood not less than 10 mm thick to window/opening area for installation of window type air conditioner of any capacity, including cutting to required size, proper fixing with screws/fasteners and making good disturbed portions to match existing finish, complete in all respects, all as specified and as directed. | 1 | Square Meter | 650 ₹650 | 500 ₹500 | 950 ₹950 | 450 ₹450 | 500 ₹500 | 560 ₹560 | 400 ₹400 Lowest | 555 ₹555 |
| 9.00 | M&L for PVC drain pipe flexible type 15 mm dia fixing with clamp all as specified and as directed. | 12 | Running Meter | 99 ₹1,188 | 115 ₹1,380 | 100 ₹1,200 | 50 ₹600 Lowest | 122 ₹1,464 | 70 ₹840 | 90 ₹1,080 | 77 ₹924 |
| 10.00 | Supply , installation & commissioning of refrigerator, electric driven (single phase), capacity 300- 310 Litres, double door ,BEE 5 star rating complete all as specified and as directed. | 6 | Each | 52,500 ₹3,15,000 | 52,000 ₹3,12,000 | 43,000 ₹2,58,000 Lowest | 49,000 ₹2,94,000 | 50,000 ₹3,00,000 | 46,000 ₹2,76,000 | 51,000 ₹3,06,000 | 48,200 ₹2,89,200 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
13 Apr 2026, 6:00 pmClosed
Garrison Engineer, Avadi
GE Avadi
SPECIAL REPAIR TO REPLACEMENT OF COOLING APPLIANCES AGAINST BER AND CONNECTED ITEM INCLUDING SPL REPAIR FOR REPLACEMENT OF BER CEILING / WALL MOUNTED/ AIR CIRCULATOR FANS FOR DGQA ESTTS INCLUDING PROVN OF GATE WITH PILLAR FOR MUSTERING IN AND OUT GAT
2026_MES_758381_1
8380/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Avadi
As per tender documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹97,000
Yes
27 May 2026
28 Mar 2026
15 Apr 2026
28 Mar 2026
13 Apr 2026
6 Apr 2026
28 Mar 2026 - 2 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | PART -I - SPECIAL REPAIR TO REPLACEMENT OF COOLING APPLIANCES AGAINST BER AND CONNECTED ITEM AT ARMY AREA | - | - | - | - |
| - | Disconnecting electric supply from source, taking down window type air conditioner of any capacity along with voltage stabilizer, without causing damage to connected wiring and other existing installations, including making good disturbed surfaces to match existing finish, complete in all respects, including stacking at MES Store Yard, GE Avadi, complete, all as specified and as directed. | - | Each Job | - | - |
| - | Supply, installation, testing and commissioning of Hi-Wall Split Type Air Conditioner of 1.5 TR capacity (5 Star rated) having minimum EER 3.2, complete with indoor and outdoor units, cordless remote control, in-built ioniser and plasma filter, copper condenser coil, including copper refrigerant tubing set (1/4" and 1/2") of required length with PUF insulation, 15 mm dia flexible PVC drain pipe with clamps( 6 Rm), GI powder coated brackets (16 SWG) for outdoor unit with suitable fasteners and grouting, power and control cabling, earthing, mounting arrangements and all connected accessories, complete in all respects, all as specified and as directed. | - | Each Job | - | - |
| - | Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input varition between 90V to 260V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 4KVA complete all as specified and as directed. | - | Each | - | - |
| - | Supply and fix copper tubing set 1/4" and 1/2" suitable for Split AC including PUF insulation and connected accessories, fixcing for outdoor unit for user requirement complete all as directed by eng-in-charge | - | Running Meter | - | - |
| - | Supply &Fix for Sub main wiring with 2x 4 Sqmm size PVC insulated unsheathed single core multistranded copper conductor cable ISI marked for working voltage 1100 volts grade, drawn in to and including PVC conduit and conduit accessories , including 4.0 sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to earth dolly and to be terminated and including taking down the old wiring complete all as specified and as directed. | - | Running Meter | - | - |
| - | Supply & fixing in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed. | - | Each | - | - |
| - | Material and labour for providing and fixing plywood not less than 10 mm thick to window/opening area for installation of window type air conditioner of any capacity, including cutting to required size, proper fixing with screws/fasteners and making good disturbed portions to match existing finish, complete in all respects, all as specified and as directed. | - | Square Meter | - | - |
| - | M&L for PVC drain pipe flexible type 15 mm dia fixing with clamp all as specified and as directed. | - | Running Meter | - | - |
| - | Supply , installation & commissioning of refrigerator, electric driven (single phase), capacity 300- 310 Litres, double door ,BEE 5 star rating complete all as specified and as directed. | - | Each | - | - |
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
8380Tenderdocuments.pdf
Tender Documents • 1.28 MB
BOQ_849449.xls
BOQ • 8.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .