Loading…
Loading…
Tender Value
₹4.2 Cr
EMD Value
₹8.4 L
Closing Date
31 Jul 2026, 3:00 pm
Provision of Supply, execution, testing and commissioning of outdoor and indoor S&T works in connection with Utility Shifting to facilitate Engineering Works for yard remodeling at stations in Sini-Kandra, Gamharia-Chandil, Dangoaposi-Jaroli, Bimalgarh - Barsuan Sections and Badampahar Yard in CKP Division of S.E Railway.
ST-CON-ROU-UTILITY-SHIFT
ST-CON-ROU-UTILITY-SHIFT
Open
24 Months
Mayurbhanj, Odisha
₹0
₹8.4 L
2 Jul 2026
2 Jul 2026
17 Jul 2026
Item Breakup - A1-S&T SOR - EXECUTION
1000.00 of roots of trees etc. in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom. Supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 10262- 2019 or latest and IS-456-2000 as per SEM Drawing No. 15- D3 (Sheet-2) on sieved soil of 30 mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This also includes supply of collar and all the materials for concreting by the contractor. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
1000.00 including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 metre. Track/Pucca road/Platform crossing/Level crossing as per SEM Drawing No.15-D5 or latest including supply, transportation and laying of RCC Pipes (full) with collar (for jointing pipes) Inner diameter/Outer diameter: 100mm/150mm to Specification No. IS:10262-2019 or latest and IS-456-2000. RCC structural drawings should be as per SEM Drawing No. 15-D3 (Sheet-2) and drawing of cable through RCC Pipes with collar (for jointing pipes) including back filling and ramming after cable laying as specified in Technical Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of platform/pucca road after cable laying.
2000.00 including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. Track/ Pucca road/Platform crossing/ Level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830 (Part-2):2001 as per SEM Drawing No. 15-D4 and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of Platform/Pucca road after cable laying.
500.00 of sizes 80 mm deep and 170 mm width for single/multiple cable chase in concrete or hard rocks or platform or cemented floor. This work includes laying and covering of cable laid in the chase with standard sizes Second class/Fly Ash brick placed and embedded longitudinally and plastered on the top of the bricks and curing 72 hrs. as per Drawing No. Con/SK/T/1 Note: Sundries materials such as Bricks, sand, cement etc., shall be supplied by the contractor at site and to be inspected by Railway Site Engineer before placing in the chase. Note: In case, chase cutting & smoothening are other than prescribed depth & width, Proportionate payment shall be released.
5000.00 existing working cables by precision digging for diversion of cables in connection with cable clearance for engineering earth work or for utility shifting without interfering the circuits as per the advice of Railway site engineer. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
500.00 Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 80 mm nominal bore Specification No. IS: 1239, Pt-1, 2004 thickness 3.2 mm medium grade, on bridges, culverts, drain or at places as per instruction of the site Engineer including supply and transportation of materials required for fixing the pipe as per SEM Drawing No.15- D7 on culverts and others including drawing of cables inside the pipe with masonry work at bridge entry and exit of the culvert and curing for 72 hours and pipes are to be clamped at max. 2 meter apart with drilling of holes on the pipe at 10 cm apart for S&T Cables. Note:- This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store.
200.00 Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 100 mm nominal bore Specification No. IS: 1239, Pt-1, 2004 thickness 3.6 mm medium grade and fixing on girder bridges as per Drawing No. CON/SK/T/4 or latest including supply and transportation of channel, angle, iron brackets, Steel Nuts and bolts with hole and split pin of proper size for fixing of trough as per above drawings including drawing of cables inside the pipe with masonry work at bridge entry and exit of the Bridge and curing for 72 hours and pipes are to be clamped at min. 1.5 meter apart for S&T Cables. Note: This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store.
500.00 RCC pipe as per Spec. No. IS: 10262-2019 or latest and IS-456-2000 & SEM Drawing No.15-D3 having plain ends with their jointing loose split collar half round of size 150 mm (inner diameter)/25mm thickness at site over the single/multiple cable laid in the trench.
500.00 of Split RCC pipe as per Spec. No. IS: 10262-2019 or latest and IS-456-2000 & SEM Drawing No.15-D3 having plain ends with their jointing loose split collar half round of size 200 mm (inner diameter)/25mm thickness at site over the single/multiple cable laid in the trench.
200.00 without wooden drums (S&T Cables) from concerned store to the site of works. Note: The unit Drum-KM indicates Drum X length of cable in that drum. It doesn't have any significance over the distance it has to be carried for execution of the work. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
200.00 in the excavated trench to Drawing No. CON/SK/T/5 or latest. Supply and transportation of 'U' clamps, anchoring of cable at every 10 metres interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81 or latest. Supply, transportation, and placing of cable demarcating led belt to Drawing No. CON/SK/T/6 or latest punched at an interval of 30 metres and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER or as per latest guidelines and guarding the cables. Collecting empty drums with left over cable and to be returned to the stores of stock holder. Note: Cables will be meggered before & after its laying by contractor under supervision of Railway representative & Contractor will submit their reports.
50.00 of Optical Fibre Cable along with HDPE pipe from the stores of SSE/Store or from any store of SE Railway to the site with care laying of HDPE pipe & blowing of OFC in it as per procedure and returning empty cable drums with or without left over cable to the stores of SSE/Store. It also includes supply and placing of warning & Detection tape orange colour of 100 mm wide printed in black as "CAUTION OFC CABLE" and laid throughout the trench as directed by the Representative of Railway. Note: OTDR of cables will be done before & after its laying by contractor under supervision of Railway representative & contractor will submit their reports.
100.00 good working condition for earth cutting, levelling, dressing etc., of ground/dismantling structures including disposal of debris through dumpers/Shifting the location box or signal post with foundation etc. with contractor's labour including machine operator, fuel etc. Payment shall be made for actual working hours at site & proportionate payment to be made in case less than hours. Note: Vehicle shall not be more than 3 years old.
50.00 of cable route trench, signal/location box foundation, track crossing etc. In case of less or more than 13 m, proportionate payment to be done. These obstructions will be removed by the contractor for ensuring proper execution of related works.
100.00 the way of cable route trench, signal/location box foundation, track crossing etc. These obstructions will be removed by the contractor for ensuring proper execution of related works. Note: In case of broken sleepers, proportionate payment will be made. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
10.00 0.25m to 0.75m at the entry of room, placing of flexible HDPE pipe as per the instructions of Railway site-in-charge and repairing of masonry wall and cement plastering after the cable is taken inside the flexible HDPE/GI pipe (to be supplied by Railway) of suitable diameter with Clamps. The supply of Clamps, masonry materials etc. are to be supplied by the contractor. Note: Unit in no. denotes as number of entry point which is required during course of cable insertion. For illustration - 1 Drum having 1Km of cable when transported for any distance will be paid this amount.
100.00 Cable Route Marker as per SEM drawing No. 15-D1 or latest.
100.00 earth excavation for pit, concrete foundation, surrounding earth work, erection and installation as per Drawing No. Con/SK/T/8 or latest and wiring to be done as per SEM Drawing No.19-D8 or as per direction of site engineer. Supply and fixing of Hylam sheet strip of appropriate size of 3 mm or 6 mm as required with hole for fixing of terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, proper soldering of cable armour with earth catenary wire, earthing of cable armour as required. Writing & terminal description including Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This also includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement. The contractor shall supply 4 no. of foundation nuts & bolts of size 22 mm dia. x 450 mm long with 2 flat spring washers, with each nut & bolts, sand for filling up cable pit inside the apparatus case including plaster and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
40.00 earth excavation for pit, concrete foundation, surrounding earth work, erection and installation as per Drawing No. SEM, 19-D2 or latest and wiring as per SEM Drawing No.19-D9 or as per direction of site engineer. Supply & fixing of Hylam sheet strip of appropriate size of 3mm/6mm as required with hole for fixing of terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, earthing of cable armour as required. Writing & terminal description including Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This also includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement. The contractor shall supply 4 no. of foundation nuts & bolts of size 22 mm dia. x 450 mm long with 2 flat spring washers, with each nuts & bolts, sand for filling up cable pit inside the apparatus including plaster and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%.
100.00 boxes, includes fixing/Removal or both the equipment, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagram. This includes filling with sand and plastering the same. Note: All the sundry materials such as paint, sand, cement, screws etc to be supplied by the contractor.
10.00 Signal Post for MACLS as per drawing no. Con/SK/T/12 or SEM-Drawing No. 19-D3 or RDSO/M-00011RU dated 12.01.18 or latest complete with signal units, base, ladder and other fittings, excavation of earth pit, casting concrete foundation, erection of posts, thereof as specified in the note given in drawing, fixing of complete fittings of the signals with necessary earth screen protection arrangement as required including termination of cables, painting and lettering as required. Foundation nuts & bolts of appropriate size as per above drawings or latest as per RDSO Drawing No. SA-116 A/M confirming to IS: 226 and IRS:S-10/78 Rev.8. or latest to be supplied. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
15.00 Aspect Signal Post for MACLS as per Con/SK/T/12 or SEM-Drawing No. 19-D3 or RDSO/M-00011RU dated 12.01.18 or latest complete with signal units, base, ladder and other fittings, excavation of earth pit, casting concrete foundation, erection of posts, thereof as specified in the note given in drawing, fixing of complete fittings of the signals with necessary screen protection arrangement including termination of cables, painting and lettering as required. Foundation nuts & bolts of size appropriate size as per above drawings or latest as per RDSO Drawing No. SA-116 A/M confirming to IS: 226 and IRS:S-10/78 Rev.8. or latest to be supplied. Transportation and fixing of Junction type Route Indicator with Route arm on the erected signal post including termination of cables, painting lettering as required.
10.00 Shunt Signal as per Con/SK/T/13 or SEM Drawing No. 19-D4 or latest complete with units, base and other fittings, excavation of earth pit, casting of concrete foundation thereof as per note given in drawing, fixing in complete fittings of signal including termination of cables, painting and lettering as required. Foundation nuts & bolts of size 20 mm x 305 mm as per RDSO Drawing No. SA-110 A/M confirming to IS: 226 and IRS:S-10/78 Rev.8.
10.00 Signals/ Guard Repeater unit/Dependent Shunt Signals / Illuminated 'A' /Illuminated 'AG' marker for MACLS on the erected signal post complete with marker including termination of cables, wiring, painting and lettering as required.
of Numbers 'P'/'G'/'C'/'A'/'AG'/'IB'/Marker/Arrow marker/ Signal Number plates with complete fittings as per site requirement.
Installation, Testing & Commissioning of LED Signals Lamps for Main signals Lighting Unit (i.e. Red/Yellow/Green) as per instruction of railway Engineer at the site. Note: LED particulars such as aspect, make, type, Sr. No. etc. to be recorded in proper in proper register.
Installation, Testing & Commissioning of LED Signals Lamps for Subsidiary signals lighting unit (i.e. Route aspect/Shunt Signal/Calling on aspect/A marker/AG marker etc.) as per instruction of railway Engineer at the site. Note: LED particulars such as aspect, make, type, Sr. No. etc. to be recorded in proper register.
testing, Numbers commissioning, two coat painting, wiring, lettering of the existing Multi aspect signals/Shunt/Calling-On Signals to suit the circuit as per approved wiring diagram. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
2.00 expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice of SER and earthing the screen with MS flat of 2"x 1/4"using GI nut bolts and washer.
5.00 47638.00 as per approved wiring diagram on 19" Relay rack/Composite/Q-Series Relay Rack with subsequent alteration. This includes supply of 3/4 X 9" anchor nuts & bolts, washer, D-bracket & 60mm insulator, supply & fixing of M.S. ladder as per requirement for rack to rack connection, on CTR and control panel, fixing of plug boards, relays, terminal blocks, terminals, filter units, tag blocks, fuses, bus bars, shelves, strips, 6mm Hylam sheet of required length for writing terminal description etc., fixing and termination of cables on the relay racks with number embossed ferrules, bunching of cables with PVC tape, earthing of cable armour including painting and lettering. Wiring and testing of complete relay rack accommodating all relays as per wiring diagram. Cement, stone chips & sand as required for mounting to be provided by contractor. All materials such as eyelets, Hylam sheets, ferrules, trough etc., if required for modification of rack shall be supplied by the contractor and to be carried out at site with no extra cost to the Railway.
5.00 51944.00 and installation of Cable Termination rack (CTR), fixing of MS Wiring ladder from relay rack to CTR, and on to top of the CTR- including supply of 3/6mm Hylam sheet of required size for fixing terminal blocks & writing terminal description, termination of cables, bunching of cables by PVC tape and earthing of cable armours, painting, lettering as required. The contractor shall draft terminal analysis chart on the white bond paper of appropriate size & supply wiring materials like eyelets of sizes, trough, condensers and resistances as per required capacity, HV protection cover with fixing top caps and danger symbol, soldering material of approved quality etc. shall be supplied by the contractor. Cement, stone chips and sand as required for mounting CTR, Sand for filling of cable pit and other required masonry work, Sundry materials such as MS plate/angles, MS wiring ladders as per approved Drawing, , Anchor bolt 5/8" X 9" with nut and washers -4 No., Nickel plated screws 2BA X1" with nuts and washers for fixing Hylam sheet, numbers embossed ferrules 2.5 sq. mm, PVC bunching tapes and buttons, paint synthetic enamel of smoke grey colour for painting, MS clamps with bolts and nuts of sizes, D-bracket and 60mm insulator, for fixing cables, screws of sizes as required shall be supplied by the contractor. Cables should be routed properly through ladder. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
works existing relay rack (Q-series/ Composite Relay Racks)/Cable Termination Racks (CTR) including works of installation, wiring, termination, testing and commissioning. The work includes fixing of aluminium/steel/M. S ladder along with supply as per requirement to accommodate additional plug board, relays, terminals/blocks, terminals, tag blocks, fuses, transformers, bus bars, TW shelves/strips etc. in the existing relay racks/CTR's, 6 mm Hylam sheets of required length for writing terminal description etc. fixing and termination of cables on the relay racks, CTR's with number embossed ferrules, bunching of cables with PVC tapes, earthing of cable armours, covers including painting and lettering, making anti tilting arrangement. Note:- a) Relay rack (Q-series/ Composite Relay Racks) : Payments for alterations in existing relays upto 20 nos. relays & above 20 nos. shall be made 50% & 100% respectively. b) Cable Termination Racks (CTR):- Payments for alterations in existing CTR upto 120 cores & above 120 nos. cores shall be made 50% & 100% respectively.
10.00 Rotary key transmitters/KLCR on Hylam sheet board including wiring & fixing of push button bell switch on Hylam sheet of 12mm including termination, painting & lettering. The sundry materials such as Hylam sheet, push bell switch etc. to be supplied by contractor. Transportation, installation and charging of 2V lead acid type Secondary Cell and preparation of electrolyte for each cell. Charging to be done as per OEM's instruction with uninterrupted power supply in presence of Railway representative. After charging, it should be kept at the dedicated location as per use. Note- If power is not available at site of work, charging may be done at nearby location as per convenience of the railway. This includes transportation of uncharged cells at the site of charging, supply of acid, distilled water at the site of charging and transportation of charged cells back to the site of work.
Numbers SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
wiring, commissioning of track circuit on Straight Portion of Track (without involving points and crossings) as per Drawing No. SK/DRG/OL/27 or latest and track bonding plan. The work includes drilling of 9/32" hole on Rails, provision of bonding, fixing and painting of Track Lead Junction Boxes, termination of tail cables, termination of Track lead wires, double Jumper wires, Installation & wiring of track feed set (Track Charger, Adjustable Resistance, choke coil, fuses, battery, relays etc.), testing of Glued/Block Joints and also lettering/numbering of track lead junction boxes, block joints and track circuits. This also includes transportation of all materials required for the above installation. Note: Track feed set, bonding wires, TLJB, channel pin, tail cable to be supplied by Railway.
10.00 track circuit on Point & Crossings as per Drawing No. SK/DRG/OL/27 or latest and track bonding plan. The work includes drilling of 9/32" hole on Rails, provision of bonding, fixing and painting of Track Lead Junction Boxes, termination of tail cables, termination of Track lead wires, double Jumper wires, Installation & wiring of track feed set (Track Charger, Adjustable Resistance, choke coil, fuses, battery, relays etc.), testing of Glued/Block Joints and also lettering/numbering of track lead junction boxes, block joints and track circuits. This also includes transportation of all materials required for the above installation. Note: Track feed set, bonding wires, TLJB, channel pin, tail cable to be supplied by Railway.
10.00 location and installation, wiring, testing and commissioning in new axle counter room/ location box. This includes fixing of DPs at site if shifting required, evaluator in relay room/ location box or goomties together with termination of cables, fixing and wiring of LV boxes, painting, lettering etc as required. Necessary insertion/modification on the control/ indication panel to be carried out as per site condition. Note: 1 set means one end of the block section.
20.00 during Engineering work, fixing, wiring, Detection testing of existing MSDAC DP as per Point direction of site engineer of Railway. This (DP) includes excavation of trenches for fixing of Tx/Rx cable, foundation etc. if required and re-erection of same DP. Note: Track device means 01 DP of MSDAC. Any Rail connect/Track device accessories like nut & bolt, insulation etc. and damage during shifting has to be supplied by the contractor. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
5.00 13523.00 point machine on MS plate fixed on concrete sleepers complete with fixing of anti-theft cover, crank handle key interlocking arrangements, Junction boxes, ground connections including smithy works, insulation of MS plate on which the point machines to be fixed from the gauge tie plate involving riveting/welding of angle cleats, termination of cables, preliminary adjustment of operation of points by crank handle, wiring, painting and lettering as required. Drilling of holes for fixing of switch extended bracket and leading stretcher bar, lubrication etc. Note: All the required nut-bolt, washer, MS-plate for anti-theft, eyelets, etc. for fixing of point machine to be supplied by contractor.
3.00 53846.00 commissioning of Electric lifting barrier ( E L B ) which includes excavation of pit, casting of foundations, fixing of pedestals, Boom rest etc., installation and wiring of control panel, booms for level crossing gate complete in all respect including provision of boom locking arrangements with fixing of boom light box, stop board boom rest and equipment of operation of gate from control panel, painting, lettering with following accessories:- (i) 2 (two) nos. lifting barriers with all accessories. (ii)1 (one) Control panel (iii) Positive boom locking arrangements for above. (iv) Emergency crank handle attachment (v) Timer unit to adjust the time for operating the barrier (vi) Fixing of Hooters/Flashers on either side of gate barrier.
3.00 49416.00 commissioning of Emergency Sliding Boom at LC gates which includes casting of total 10 nos. concrete foundation including surrounding earthwork, fixing of lock post, clamps, welding of channel, cutting of rail post if required as per site condition. Note: All materials to be supplied by the contractor except Sliding Boom gates & key lock 'E' type.
wiring, commissioning of the Control cum Indication panel type Mid-section interlocked LC Gate/IBS/Siding motor operated point operation panel /Non- Interlocking panel of third line section as per approved interlocking plan, FPD, circuit diagram etc. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
100.00 Earth electrode with construction of cement enclosure to SEM Drawing No. 19- D6 and drawl of 6 SWG GI/Copper cable from earth electrode to goomties/relay room/cabin/station, etc. and drawl of MS flat 35mm x 6mm for signal post/Location box shall be used as the case may be, including fixing at both ends of the wire/MS flat. This includes transportation of materials. Note: Materials such as charcoals, salt, sal ammoniac, 6 SWG GI wire, copper lugs with Steel bolts & nuts etc. shall be supplied by the contractor. MS flat 35mm x 6mm/Copper cable shall be supplied by Railway.
50.00 Earth pit as per RDSO Drawing No. SDO / RDSO/ E&B/001 which includes the following, a) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer.
100.00 0.5 meter and laying 50 mm X 6 mm bare Galvanized steel tape connecting all the earth pits. Carrying out exothermic weld connections on all the earth electrodes. It shall be ensured that the distance between any two earth electrodes shall be minimum 3 meter (length of the earth electrode) and maximum up to 6 meter (twice the length of the earth electrode) to avoid mutual resistance effects. Earth enhancement compound of 10 Kg along each meter also to be spread along the Galvanized steel tape.
100.00 copper tape/8 mm solid copper round conductor which is to be fixed inside the equipment room with 60 mm, 6KVA insulation studs including supply of insulation studs. The separation of the two successive insulation studs should be 600mm apart. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
100.00 equipment in the equipment/relay room to SEEB with 10 sq. mm copper cable using copper lugs with stainless steel nut and bolts and fixtures. The work includes laying and routing the copper cable in PVC / conduits and fixing them on wall. The PVC/conduit pipe to be supplied by Railway.
200.00 the equipment room/SEEB to MEEB with 16 sq. mm copper cable using copper lugs with stainless steel nut and bolts. The work includes laying and routing the copper cable in PVC / conduits and fixing them on wall. The PVC/conduit pipe to be supplied by Railway.
100.00 meter and run the two 35 sq. mm earth conductor in protective PVC conduit pipe, procured against supply item, from Earth pit to MEEB. Routing and exothermic termination of two 35 sq. mm cable on earth conductors as well as on 300 mm X 25 mm X 6mm MEEB, which is to be fixed inside the equipment room with two 60mm insulation studs. The 60mm insulation studs have also to be supplied.
wiring, commissioning of managed SDH (STM-1 Add/Drop MUX and upgradable to STM-4) fully wired for 2 X 63 MB and equipped for 21 E1s and a Virtual Container (VC)-12 with STM-1(L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or with latest amendment.
2.00 15176.00 krone modules, testing and commissioning of 2 Mb Programmable Primary Digital drop insert multiplexer as per RDSO Specs. No. - IRS/TC/ 68/2012 Rev.0 with Amendment No.1 or latest. It includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of the system.
2.00 48V/50amp SMPS based power plant in 2+1 configuration using 3 Nos. of 48V/25A modules to charge the VRLA battery bank of 48V/200AH or 48V/300AH with lightening & surge protection as per Specification No. RDSO/SPN/TC/23/1999 Ver.4 Amnd.1 or latest. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
100.00 jelly filled Telecom cable using Thermo- shrink/Universal jointing kit (RTSF). This includes excavation of cable joint pit of size 1.5 m X 1.5 m X 1.2 m for jointing of cables, back filling and ramming after jointing. After jointing, the cable through test such as insulation test, continuity test etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing the contractor has to redo the joint free of cost. Note: In case jointing is required to be done in the Location boxes, then 80% payment will be released.
8.00 Fibre Distribution Management system (FDMS) for 24 Fiber complete with all accessories such as patch cord & pigtail etc. as per TEC Spec. with latest amendment. The sundry material if required any to be supplied by contractor.
8.00 Fibre Distribution Management system (FDMS) for 48 Fiber complete with all accessories such as patch cord & pigtail as per TEC Spec. with latest amendment. The sundry material if required any to be supplied by contractor.
250.00 in joint closure/FDMS as per instruction of site Engineer.
10.00 RCC joint chamber with two piece top cover and bottom cover with holes for drainage and cable entry, as per Drawing No. RDSO/TCDO/COP-21 or latest. This includes trenching for jointing pit of size min 1.5 m X 1.5 m X 1.2m for all types of soils, back filling and ramming of the pit after placing the joint closure and cable loop in the chamber including dry sand upto 600mm height without causing any damage to same and consolidation of soil as well as disposal of excess soil. Transportation and fixing of following types of C.T. Box (Aluminium/Wago type) and termination of cable as per details of jointing schedule approved by the Railway Engineers.
10.00 commissioning of Magneto Portable Telephone (desk type) as per specification IRS/TC/79/2000, Amdt 4 or latest including supply of dry cell batteries. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
20.00 termination of cable, erection of rail post of size minimum 2.8 meter including foundation of post in cement concrete (1:2:4) as per the direction of the section engineer in charge, testing and commissioning of Emergency socket box of FRP Material as per RDSO/SPN/TC/44/2002 Ver.3 or latest with 6 pin Emergency Plug and Socket as per TC-42/20 Version- 1.1 or latest and other accessories. This includes transportation of rail posts, provided by the Railway, from any place/Station to work site; fixing of GI pipe and emergency socket box. GI pipe (make: TATA/Jindal or better) minimum 40 mm. dia., minimum 1.8 meter long as per IS 1239 grade medium, FRP emergency socket with complete fittings. Supply of materials required for masonry work, U- bolt for fixing emergency socket etc., cutting of Rails and welding or suitable clamp of GI pipe on the rail post will be done by the contractor.
100.00 (Cement: Sand: Stone chips of 20mm nominal size) for miscellaneous works. It includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor.
200.00 pipe/channel/casing caping on wall or structure with drawls of Telecom/Power/Data cable with proper finishing. This includes supply of fixing materials including flexible pipe/bend etc. as required during course of execution.
300.00 S & T gears by deputation of Days Helper/Unskilled labour for executing additional Signalling & Telecom portion of the works. The work can involve fixing, releasing, dismantling, replacement, excavation, clearing of vegetation, loading and unloading of material and assisting skilled persons etc. as per instruction of Railway representative at site. The contractor has to carry materials to field and the released materials from site has to be taken back to the concerned SSE/Signal/Telecom store. The contractor has to arrange necessary tools such as bar, sickle, cutter, pickaxe, rake, hoe etc. as per instruction of Railway representative. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
300.00 S & T gears by deputation of Days Fitter/wireman /Painter/welder/Mason/cable jointer i.e., Skilled labour for executing additional Signalling & Telecom portion of the works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration of various signalling assets or parts, termination of cables, minor patch work on damages at location box, Plastering, concreting brick work, wiring alterations, cable jointing etc. as per instruction of Railway representative at site. The contractor has to carry materials to field and the released materials from site has to be taken back to the concerned SSE/Signal store. The contractor has to arrange necessary tools for carrying out the work as per Railway representative instruction. Total 23267856.00
Item Breakup - A2-NON SOR MICRO TUNNEL
HDD: machine/Micro Tunnelling through Horizontal directional drilling (HDD) machine with accessories including handling of stores materials, preparation of sites, boring and laying of DWC/HDPE/GI pipes for crossing of S&T cable at bridges/culverts/track crossing/pucca road crossing. Boring diameter should be at least 110mm & shall be minimum 3 (three) meter below the river bed and minimum 1 m at track/road/pucca road crossing area etc. In case the site doesn't allow to perform as per schedule, written approval must be obtained from at least site in charge officer. The ground level shall be considered ignoring the bank height of the bank of the road. Note: DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after laying of the cables into DWC/HDPE/GI pipe is laid in the bore.
Supply of ISI Marked HDPE pipe 110mm Metre dia conforming to IS.4984 or latest. Made of virgin material and grade of PE63 pressure at 30 degree centigrade PN6 coil type or 6Mtr Length Pipe. Colour: Black. Make: VENUS, Amatron, Apollo, Surya, Finolex or equivalent. Total 1032270.00
Item Breakup - A3-NON SOR EXECUTION
Alteration of Existing Location Box Sheet Drawings (Including Contact Analysis, Fuse Particulars etc) and submission of Three paper copies for approval Note : Unit will be read as Per Sheet.
Alteration of Existing Goomty Drawings Sheet (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) and submission of Three paper copies for approval Note : Unit will be read as Per Sheet. Total 64243.75
Item Breakup - B1-S&T SOR SUPPLY
50.00 No. RDSO/SPN/TC/45/2013 Rev-2.0 or latest with OD/ID of size 50mm/42mm with suitable couplers, plugs, end caps, spacer, T band etc. as required during execution at the site.
100.00 as per Drawing No. SK/Drg./OL/SER /198 or latest with E type lock . E-type lock & their key ward No. will be decided by site engineer as per Specification No. IRS: S- 10/78 with Rev. 8 or latest. Supply of Hylam sheets is not covered under this scope. This includes supply of one key & handle for each four Apparatus Case or minimum one.
40.00 as per Drawing No. RE/S&T/ALD/SK/ 220/82 Alt.A and 221/82 with Alt. B or latest with E type lock. E type & their key ward No. will be decided by site engineer as per Specification No. IRS:S-10/78 with Rev. 8 or latest. This includes one key & handle for each four Apparatus Case or minimum one.
100.00 955mm x 400mm per specification no. IS 2036 of 1995 or latest. Note:- In case the requirements are different from the above, proportionate payment will be done. Supply of Non-Deteriorating type of low voltage electric fuse for Railway signalling use, fuse with cylindrical cap without indication, cylindrical fuse as per Specification No. IRS:S-78/2006 or latest.
300.00 co-efficient self-Restoring Type fuse (PPTC) of 24-110 V, 4 Amps capacity Fuse should have an insulating coating of flame retardant epoxy to meet UL-94, V0 requirement working temperature range 40 Degree Celsius to 85 Degree Celsius and leads to be tin platted copper.
10.00 Post for Colour Light Signal Specification No. IRS:S-6/81 or latest to suit 140mmm dia. base. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
10.00 Light Signal as per RDSO Drawing No. SA- 23156 (Adv.) or latest and Stage with Ladder foundation as per Drawing No. S- 2033/M (IRS) or latest & as per Specification No. IRS:S-10/78 & IS:210 or latest.
45.00 Lighting unit working on 110V AC as per Specification No. RDSO/SPN/ 199/ 2010 Rev 1.1 or latest.
60.00 Lighting unit working on 110V AC as per Specification No. RDSO/SPN/ 199/ 2010 Rev 1.1 or latest.
45.00 Lighting unit working on 110V AC as per Specification No. RDSO/SPN/ 199/ 2010 Rev 1.1 or latest.
10.00 unit working on 110V AC as per Specification No. RDSO/SPN/153/2023 Rev 5.0 or latest.
50.00 working on 110V AC as per Specification No. RDSO/SPN/153/2023 Rev 5.0 or latest.
30.00 working on 110V AC as per Specification No. RDSO/SPN/153/2023 Rev 5.0 or latest.
100.00 inside dia. 40.5mm, outside dia. 60mm. Thickness 20mm, lock length 65mm.
27.00 terminal block, screwless type i.e. Wago confirming to Specification No. RDSO/SPN/189/2004, Ver.3 or latest. Connection method: Spring-cage connection, Cross section: 0.2 mm² - 2.5 mm², Nominal current: 16 A, Nominal voltage: 400 V, Color: as per instruction of site engineer. Flammability rating according to UL 94-V0.
300.00 slotted) Size: 35mmx7.5mm as per Specification No. RDSO/SPN/189/2004, Ver.3 or latest.
500.00 disconnect terminal as per RDSO/SPN/189/2004 or latest.
20.00 terminal.
200.00 wago terminal.
200.00 wago terminal.
1.00 343262.00 conductor Indoor Cable of size 40 Core x 1.0mm diameter as per Specification No. IRS:S-76/89 or latest.
1000.00 conductor dia. PVC Switch Board Cables as per TEC specification GR/WIR-06/03 of march 02 or latest.
1000.00 conductor dia. PVC Switch Board Cables as per TEC specification GR/WIR-06/03 of march 02 or latest. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
200.00 Relay, Non-AC immune, plug-in type, working over 24V DC and having 8F/8B metal to carbon contact with plug board, retaining clip & connectors conforming to BRS:930A, and IRS:S-34 /68 Amd.6 or latest & IRS:S-23/88 Amd.1 or latest. The interlocking code for this unit shall be "ABCDF".
300.00 Relay, AC immune, plug-in type, working over 24V DC and having 8F/8B metal to carbon contact with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60/78 Amd.1 or latest, IRS:S 34/68 Amd.6 or latest & IRS:S 23/88 Amd.1 or latest. The interlocking code for this unit shall be "ABDGH".
20.00 latched DC Neutral Line Relay, plug in type, working over 24V DC and having 11F/4B metal to carbon contacts, complete with plug board, retaining clips and connectors conforming to BRS:935, IRS:S 34/68 Amd.6 or latest & IRS:S 23/88 Amd.1 or latest. The interlocking code for this unit shall be "ABDEG".
50.00 Relay, AC Immune, plug-in type, working over 24V DC slow to pick up and having 8F/4B metal to carbon contact, complete with plug board, retaining clip and connectors confirming to BRS:933A, IRS:S 60/78 Amd.1 or latest, IRS:S 34/68 Amd.6 or latest & IRS:S-23/88 Amd.1 or latest. The interlocking code for this unit shall be "ABDEJ".
60.00 Relay, AC Immune, plug-in type, 9 Ohm, 2F/1B metal to carbon contacts, complete with plug board, retaining clip and connectors confirming to BRS:939A, BRS:966 (Appendix F2), ,IRS:S 34/68 Amd.6 or latest & IRS:S 23/88 Amd.1 or latest. The interlocking code for this unit shall be "FGHKX".
10.00 Relay, AC Immune, plug-in type, 9 Ohms, 2F/2B metal to carbon complete contacts with plug board, retaining clip and connectors confirming to RDSO Specification No. RDSO/SPN/084 Ver 2.0 with Amd.1 or latest. The interlocking code for this unit shall be "ABEJX".
5.00 device operated over 24V DC as per Specification No. RDSO/SPN/173/2002 with Amd-2 or latest.
of (EKT)/Rotary key transmitter (RKT) as per Specification No. IRS:S-21/2001 Rev 1.0 or latest & Drawing No.SA-22601 or latest with the keys and wards nos. will be per instructions given by site Engineer in charge. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY Supply of uncharged Low Maintenance Lead Acid (LMLA) Secondary Cells for S&T installations having nominal voltage 2 volts as per Specification No. IRS-S- 88/2004 Ver. 1.0 or latest.
Numbers Supply of VRLA Secondary Cells for S&T installations having nominal voltage 2 volts as per Specification No. IRS-S-93/96 with Amdt. 1.0 or latest.
60.00 made of fibre reinforced plastic as per RDSO drawing No. SA 20101/M (IRS) or SI- 10272 (FRP) and as per Specification No. RDSO/SPN/151/1997 or latest with bush & ARA terminals conforming to IRS: S-75/91 or latest. 1 way 60mm PBT terminals, 18" GI pipe of adequate size & MS angles 1500x50x50 mm3 are also to be supplied by the contractor.
60.00 Resistance (Porcelain Base, Phenolic, Moulding Base) 0-30 Ohm (with tapping at 2, 4, 8 & 16 Ohm) as per RDSO Drawing No. SA-20161-66 or latest and Specification No: IRS:S-23 or latest.
500.00 wire for Track Circuit Bonding or for other application as per Specification No.IS:279/81 or latest.
2.00 single groove for bonding Track Circuiting wires of 7mm dia. for 4mm dia. bond wire to RDSO Drawing No. S-69/M or latest as per Specification No. IRS: S17-75 Rev 3 & IS: 1573-70 or latest.
1000.00 stranded wire rope 7x7 construction, 19 mm circumference, Tensile Strength 125- 140 Kg per square mm as per Specification No. IRS:S-3/61 or latest wrapped with Extruded jacket of PVC, thickness 2 mm. Wire colour will be decided by Engineer in charge.
2.00 machine cycle gear type suitable for size 9/32 inch diameter rail hole in Railway Track suitable for 52 kg or 60 kg.
50.00 track drilling machine. Make-JK or similar.
3.00 51788.00 voice logging facility for LC Gate Telephone System as per Specification No. RDSO /SPN/TC/51/2011 Rev 1.0 or latest.
9.00 Gate Telephone System as per Specification No. RDSO /SPN/TC/51/2011 Rev 1.0 or latest.
3.00 both 12V & 24 V DC Output including battery charger with minimum 7AH, 24V DC MF Battery. 12V DC supply shall be connected to the Station Telephone Unit & 24V DC shall be fed to Line Circuit for LC gate telephone system as per Specification No. RDSO/SPN/TC-51/2011, Rev 1.0 or latest. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
1.00 RDSO Drg. No. IRS-3529/M Alt-1 or latest and Specification No. IRS-S-10/78 Rev 8 or latest.
100.00 No. 19-D6 of SEM-2021 or latest. GI pipe confirming to IS:1239 or latest of 3.17 mm thickness, minimum 2.5 m long, 50.8 mm diameter, 4.76 mm diameter drilled holes staggered at distance of 152.4 mm.
500.00 Plate Strip as per IS: 226-1975 or latest for earth connection to Signal post, L/Box etc.
30.00 Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002 or latest are as under, (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 No. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. It also includes supply of (i) 35 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter.
20.00 Maintenance Free Earth for Ring Earth consisting as per Specification No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/RDSO/E&B/002 or latest. (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm dia. minimum with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No. (d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No. (e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No.
100.00 tape for interconnecting the earth pits.
50.00 strips or 8mm round solid copper in the equipment room.
1000.00 treatment of earth pits as per Specification No. RDSO/SPN/197/2016 Ver 1.0 or latest. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
1.00 159694.00 all necessary accessories including rechargeable battery pack and charger Liquid Crystal Display (LCD) with back light. Low Insulation Faults Mode Max. Range: 20 Km etc. Make - Radiodetection/Stanley/3M or better.
2.00 358237.00 enable 10 Watt transmitter, rechargeable battery pack and main charger, direct connection lead 10 meter extension cable with all other accessories. Make- Radiodetection/Stanley/3M or better.
of Reflectometer (OTDR) as per TEC Spec No. : TEC/GR/TX/OTD001/05/SEP-19 or latest. Make- Yokogawa/ Fuzikura/ Sumimoto or better.
2.00 cycle as per specification are as under, Mechanical 5 digits counter, ABS Plastic wheel with rubber tyre, measure Forward & Backward, Telescopic handle, Precision measuring wheel with bag. Make: Stanley/Bosch/ JCB/Freeman or better.
1.00 201674.00 MUX and upgradeable to STM-4) fully wired for 2 X 63 MB and equipped for 21E1s and a virtual container (VC-12) with STM1 (L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or latest. The contractor will supply all other accessories as mentioned in the above said TEC Specifications and system will have provision of different redundancy cards as per the TEC Specifications. Note: It shall be possible to increase capacity from 21E1 to 63 E1s by adding / inserting tributary cards. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH equipment with all cards to the 48V Bus including supply of wires and connectors. Termination of all E1s on DDF taking PVC cable over runway or a wall. At the terminal station, one port may be disabled if required as per instructions given by site engineer incharge.
1.00 151761.00 Digital Drop/Insert multiplexer with conference facility as per RDSO Specification No. IRS: TC-68/2012 Amd.1 or latest wired for 30 Circuits complete with power supply, Control and Basic/Common cards, Remote control supervision facility and all other accessories etc. The mux shall be equipped with fallowing interface cards A) 2W/4W E&M interface card (4 ckts per card)-04 Nos. B) FXO Exchange loop interface card (4 ckts per card)-2 Nos. C) FXS Subscriber interface card (4 ckts per card)-02 Nos. SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
1.00 76694.00 based power plant in 2+1 configuration using 3 Nos. of 48V/25A modules to charge the VRLA battery bank of 48V/200AH or 48V/300AH with lightening & surge protection as per Specification No. RDSO/SPN/TC/23/1999 Ver.4 Amnd.1 or latest.
100.00 for jointing underground Quad cable of size 0.9mm/1.4mm diameter conductor for straight/condenser/Y-(Derivation)/Loading Coil/Transformer Joints as per Specification No. IRS-TC-77/2012 Rev.3 with Amd. 3.0 or latest.
20.00 Specification No. RDSO/SPN/TC/68/ 2014 Rev 1.0 or latest complete with all accessories including sealing with mechanical clamp facility.
15.00 similar to Specification No. RDSO/SPN/TC/68/2014 Rev 1.0 or latest including sealing with mechanical clamps.
20.00 CRC sheet with disconnection and reconnection (wago type). The CT Box should be grey colour powder coated with terminal, washer, nut & bolt should be of brass. There shall also be locking arrangement.
1.00 35914.00 complete with all fitting for housing the subrack SDH ADMs & PD Mux or other equipments as per instruction of Railway Engineer fully wired including, Power supply distribution system, DDF, Internal wiring and other accessories, runway ladder etc. or for other application. The components of the rack are specified below- (i) Rack size 2035 HX 600 WX 600 D (ii) Fixed side panels 42U X 600 D (iii) Front glass door plain 42U X 600D (iv) Rear MS door plain 42 U X 600W (v) Levelling screws-4 Nos. (vi) Compact Fan Module working with 48 V DC or other voltage - 2 Nos. (vii) Earth connecting kit-1 No. (viii) Cable manager with cable loops-2 Nos. (ix) Krone mounting bracket-01 No (x) Caster with breaks-2Nos (xi) 20" length 1" width 5 mm thickness copper strip with 12 Nos. of holes including SS bolts & nuts for every hole to connect cables-2 Nos. (xii) 10A single pole DC MCB-2 Nos. (xiii) 6 A single pole DC MCB-2 Nos etc.
1.00 dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws. Make: CP Plus, D- Link, or better
10.00 dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws. Make: CP Plus, D- Link, or better SER-CONST-HQ-S AND T/SOUTH EASTERN RLY
of (1120:470/1120:1120/470:470/470:600/ 1200:600 Ohm) as per Specification No. IRS-TC-76/2021 Ver 1.0 or latest (Cylindrical type) or IRS/TC/22/ 2021 Ver 1.1 or latest (Rectangular type).
100.00 rigid plain ended conduit size IS:9537 (part-3) or latest and 9537 (Part-1) 1980 with latest amendment ISI marked with minimum 1.2 mm wall thickness & minimum one socket at every 3 meter pipe.
10.00 with metal enclosure. Make: Schneider/Legrand/L&T/Havells. Total 16533064.00
Item Breakup - B2-NON SOR SUPPLY
Supply of FRP type vertical point Junction Numbers Box as per as per drawing No. SI./TYP/102 issued by ER on 04.08.25
Supply of Non-metallic (FRP) Colour Light Numbers Signal, for Two aspect Complete without lenses, lamp holder and Signal transformer as per RDSO Drawing No. SA/23003 A/M (Adv.) or latest and as per Specification No. RDSO/ SPN/194/2006 Rev. 2.0 or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post.
Supply of Non-metallic (FRP) Colour Light Numbers Signal, for Three aspect complete without lenses, lamp holder and Signal transformer as per RDSO Drawing No. SA/23002A/M (Adv.) or latest and Specification No. RDSO/SPN/194/2006 Rev.2.0 or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post.
Supply of Non-metallic (FRP) Colour Light Numbers Signal, for Four aspect complete without lenses, lamp holder and Signal transformer as per RDSO Drawing No. SA/23001 A/M (Adv.) or latest and Specification No. RDSO/SPN/194/2006 Rev.2.0 or latest. Mounting socket including its material shall be as per RDSO Drawing No. S 23005/M or latest for mounting on 140 mm outside diameter post.
Supply of Non-metallic (FRP) 4 way Numbers Junction Route Indicator Unit Without Lens & Holder as per Specification No. RDSO/SPN/194/2006 Rev.2.0 or latest as per RDSO Drawing No. SA 23404 or latest suitable for LED signal lighting unit as per IRS:S-66/84 Amd. 1 or latest. Total 1049792.95
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
InspectionAuthority.pdf
ATTACHMENT
TenderDocumentforUtilityShifting.pdf Tender Document
ATTACHMENT
1.IRGCCApril2022.pdf
ATTACHMENT
2.ACS1toACS11ofIRGCC2022.pdf
ATTACHMENT
3.UpdatedSERSTSOR2024Ver2.1.pdf SOR S AND T 2024
ATTACHMENT
4.JPOfordiggingwork.pdf
ATTACHMENT
3.UpdatedSERSTSOR2024Ver2.1.pdf
ATTACHMENT
TenderDocumentforUtilityShifting.pdf
ATTACHMENT
Download all tender documents and submit your bid