Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC PO HATIALI SIDING CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹44.2 L+₹1.6 L (3.75%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹44.4 L+₹1.8 L (4.17%)Rejected-Finance AT ROAD HATIALI PO CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹44.8 L+₹2.2 L (5.10%)Rejected-Finance PO CHABUA DISTT DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹45.0 L+₹2.4 L (5.56%)Rejected-Finance AT ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹43.6 L
EMD Value
₹87,500
Closing Date
24 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) CHABUA
GE (AF) CHABUA
ADDITION/ ALTERATION TO BUILDING NO. 03 (STN HQ) AT AF STN CHABUA UNDER GE (AF) CHABUA
2023_MES_626568_1
530/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) CHABUA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (AF) CHABUA
₹87,500
24 Dec 2023
3 Nov 2023
27 Nov 2023
3 Nov 2023
24 Nov 2023
17 Nov 2023
3 Nov 2023 - 10 Nov 2023
Amount
SCH 'A' PART-I
Dismantling asbestos cement (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F structural steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, tubular section, channel or flat sections) as in trusses, purlins, rafter, post etc. conforming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plat, gusset plate and also erecting in true position complete all as specified and directed.
S&F gusset plates, cleats etc including necessary welding drilling for fixing using Fe 410-W (Gde E-250 Quality- A) complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour having tensile strength of 550 Mpa as in plain sheet as in ridges, gutters, facia bed etc, fixed with self tapping screws or 'J'/'L' hooks complete all as specified and directed.
All as per item No. 05 here-in-before but plain sheet as in ridges, gutters, facia bd etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
S & F for suspended false ceiling using anodised GI exposed ceiling suspension system of grid size 60 cm x 60 cm width main runner ' T " section of size 38 mm x 24 mm x 0.4 mm thickness and wall angle of size 24 mm x 24 mm x 0.3 mm thickness and cross Tee of size 24 mm x 24 mm x 0.43 mm thick GI system duly suspended with 4 mm dia Gl bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing position for light fixtures, air conditioning diffuser and ducks, sprinkler, smoke detector etc. The main runner to be secured to structural soffit by hanger @ 1220 mm maximum C / C . The last hanger at the end of each runner should not be placed at more than 450 mm from the adjacent wall . Flush fitting 1200 mm cross ' T " to be inter locked between main runner @ 610 mm C / C so as to form 600 mm x 600 mm grid complete all as specified and directed.
S&F 4 mm thick non asbestos cement building boards (E boards) to framework with screws in false ceiling one face printed engraving to match existing and factory coted (white) complete all as specified & directed.
Taking down existing false ceiling boards and refixing in same position/grid after replacement of roof sheets complete all as specified & directed.
M&L for preparation of old plastered or unplastered surfaces of ceiling boards of any description and applying one coats of oil bound distemper complete all as specified and directed.
Demolition of brick work built in cement mortar of any description complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping and kerbs etc including necessary form work etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15 mm thick plaster in CM (1:4) on brick wall or concrete surfaces finished even & smooth complete (without using extra cement) complete all as specified and as directed.
M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick or concrete surfaces finished even & fair complete all as specified and as directed.
M&L for applying two coats of acrylic smooth exterior paint of required shade (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) after complete removal of old treatment by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth any surfaces of wall of any description over 10 cm width or girth not otherwise described complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over 2mm thick wall care putty complete all as specified and as directed.
M&L for preparation of old painted steel surfaces over 10 cm width or girth and applying one coats synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling floor hearth and wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises, complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc 15 cm thickness (above or below GL) complete all as specified and as directed.
M&L for 25 mm thick levelling course in cement concrete type B-1 (1:2:4) using 20mm graded aggregate complete all as specified and directed.
M&L for vitrified ceramic tiles 8-10 mm thick dark shade, (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for vitrified ceramic tiles 8-10 mm thick light shade, (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
All as per item No. 26 here-in-before but on dado/skirting over 10 mm thick plastering in CM(1:4) complete all as specified and directed.
Taking down carefully existing bituminous felt including plaster lime or concrete of any thickness, and cleaning of the surface of roofs, terrace including flushing and junction of parapets, kerb walls, PCC fillets benching etc. with wire brushes complete all as specified and directed.
M&L water proofing treatment to RCC roof slab, shall be carried out as specified below and as directed by Engineer-in-Charge:- (a) Applying 10mm hick plaster screed bed layer in CM 1:3 on concrete surfaces after preparation of surfaces. (b) Preparing plastered surfaces by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20kg/Sqm of area. (c) Laying App polymer modified approved membrane, non woven, polyester, weighing not less than 3.0 kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of engineer-in-charge.
Supply only integral water proofing compound complete all as specified and directed.
S&F in repairs solid PVC wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site complete all as specified and directed.
S&F in repairs 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame complete all as specified and directed.
SCH 'A' PART-II
Taking down carefully copper/aluminium point wiring from existing conduit (light, fan, socket or power) complete, fittings such as switches, ceiling roses, pendants, regulator, sockets and DBs, MCBs, Sub main wiring etc) and making good disturbed surfaces of walls, floor etc of exist point complete all as specified and directed.
M&L for point wiring complete with PVC insulated unsheathed FRLS-H multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two single core drawn through in and including PVC concealed conduit pipe 20mm dia medium grade ISI Marked complete with one run of PVC insulated copper conductor cable 1.5 Sq mm single core green colour earth wire and connecting to earth dolly including colour coding of cable shall be for phase, neutral and earth wire as specified in MES SSR Part I 2009 with provision of sunken galvanised not less than 1.12 mm thick MS sheet pressed terminal boxes concealed on wall, with 3 mm thick laminated sheet top cover for fixing of switches/socket/regulator with screws complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing for one light/fan/bell point controlled by one switch. Complete all as specified and directed. Note:- Cutting chases, making good disturbed surface shall be included in quoted rate.
All as per item No. 34 here-in-before but for one 5 amps switch socket combination on independent board complete all as specified and directed.
All as per item No. 34 here in before but with 2.5 Sqmm PVC insulated unsheathed FRLS-H multistranded copper conductor for power point complete all as specified and directed.
Supply and fix switch piano flush type, 5 Amps 240 volts single pole one way complete all as specified and directed.
Supply and fix modular switch 1 way, 6 amps, 1 module complete all as specified and directed.
Supply and fix modular switch 1 way, 16 amps, 1 module complete all as specified and directed.
S&F modular socket, 6 Amps, 2/3 pin combined 2 module complete all as specified and directed.
S&F modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified and directed.
S&F modular fan regulator, 120 watt, 2 module complete all as specified and directed.
Supply and fixing surface and wall mounted LED batten fitting, including LED light with complete fitting of 18 watt, including provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100Volts grade complete all as specified and directed.
Supply and Fixing LED light fittings 36 Watt Recess Mounting type, with mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) Sheet aluminium housing with high quality LGP and PMMA diffuser, Separate HPF driver suitable for Armstrong and grid ceiling LED 240 volt along with fixing arrangements all as directed.
Taking down existing Ceiling light any type carefully and refixing the same ceiling light complete all as specified and directed.
Taking down existing ceiling fans (any make) of 1200mm sweep and refixing the same after cleaning, greasing, oiling and servicing, oiling and greasing complete all as specified and directed.
S&F in replacement Modular ceiling rose three terminals complete all as specified and directed.
Supply and fixing in replacement LED light fitting Surface mounting Round type complete 1x12 W, (Dimensions for round light minimum : Ø180x40mm), complete all as specified and directed.
S&F modular cover plate with frame, 6 module complete all as specified and directed.
S&F modular cover plate with frame, 8 module complete all as specified and directed.
S&F modular metal flush box 6 module complete all as specified and directed.
S&F modular metal flush box 8 module complete all as specified and directed.
M/S Dee Dee Singhania & Sons
D.D Construction
M/s KL Agarwalla & Co
M/S MAHATO ENTERPRISE
M/S DURGA CONSTRUCTION & CO
pintoo construction
M/S D P BERLIA
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .