| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.9 L+₹4.7 L (15.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹34.5 L+₹5.2 L (17.9%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹35.2 L+₹6.0 L (20.4%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹36.1 L+₹6.9 L (23.5%)Rejected-Finance H NO 283 PHASE 3 KRISHNAPURAM MISROD HOSHANGABAD ROAD BHOPAL MP PIN 462046 | BHOPAL | BHOPAL | MADHYA PRADESH | 462046 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
5 Oct 2023, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF CEILING FANS EXHAUST FAN WALL MOUNTED FAN AND MISC EM WORKS AND REPAIR MAINT OF INTERNAL WIRING INCLUDING SUB MAIN WIRING SPN TPN DBs BUILDING SECURITY LIGHTS AND CONNECTED ITEMS TO OTM ACCN AT BAIRAGARH UNDER GE BHOPAL
2023_MES_617938_1
8205/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹99,980
Yes
12 Dec 2023
9 Sept 2023
7 Oct 2023
9 Sept 2023
5 Oct 2023
23 Sept 2023
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down old ceiling fan/exhaust fans/wall mounted fan of any capacity/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantling of fan, carried out repair/over hauling including removing dust and grease and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed. NOTE: (i) Rewinding and replacement of defective parts, painting etc shall be measured and paid seperately. (ii) Burnt out fan shall be kept separately and to be repaired/rewinded at AGE E/M yard and to be hanged in existing position after rewinding. (iii) Old ceiling fan will be deposited to MES Store.
Supply only the following items for fixing against defective parts of fan taking down under item No 1.00 here in before complete all as specified and directed.
(a) Bearing No 6201 Make : SKF/NBC/FAG
(b) Bearing No 6202 Make : SKF/NBC/FAG
(c) Bearing No 6203 Make : SKF/NBC/FAG
(d) Bearing No 6204 Make : SKF/NBC/FAG
(e) Rubber bush as required at site suitable for ceiling fan
(f) Condenser 2.5 mfd Make: Epcos/Tibcon
(g) Condenser 4.0 mfd Make: Epcos/Tibcon
(k) Lath work of Fan shaft any type / size.
Notes for ser items Nos 1.00 to 2.80 1. Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the AGE E/M Bairagarh sub-division in present of concern JE E/M. 2. Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. 3. Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. 4. Contractor detail the staff electrician to attend the complaints of fans daily in morning from concern JE E/M and submit the report daily in the evening regarding the attended complaints. 5. The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted.
M&L for rewinding of ceiling fan of sweep 1200 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
M&L for rewinding of ceiling fan of sweep 1400 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
M&L for rewinding of exhaust fan of 450 mm any make any model, 1400 RPM with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
M&L for rewinding of exhaust Fan of 380 mm any make any model, 1400 RPM with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
M&L for rewinding of exhaust fan/ fresh air fan of 280/300 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
M&L for rewinding of wall mounted fan 400 mm sweep any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
M&L for rewinding of pedestal fan 400 mm sweep any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing testing etc. complete all as specified and directed.
S&F of blade assy of wall mounted fan of 400 mm sweep complete all as specified and directed.
S&F of 'U' clamp for hanging ceiling fan in ceiling to be fixed with 3" long ancher fasterner 3 Nos for each clamps complete all as specified and directed.
S&F of ceilling fan down rod of size 15mm GI pipe medium grade(ISI mark) length upto 1500 mm including making holes, nut bolts, spilit pin washers etc complete all as specified and directed.
S&F of PVC insulated multistranded copper conductor, sheated round cable ISI marked 1.0 Sqmm, 3 core complete all as specified and directed.
M&L for painting of following items with two coats of DUCO paint (ISI grade) white using spray machine for spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos in all ceiling and exhaust fan complete all as specified and directed. Note:- Taking down and hanging of fan will be measured under item No. 1.00 separately.
(a) Ceiling fan upto 1200/1400 mm sweep
(b) Exhaust fan upto 300/380/450 mm sweep with smoke grey
M&L for attending the complaint of fan not working/ slow speed at site by deploying electrician and checking all electrical connection, tightening/ refixing of any loose electrical connections/ wires, cleaning and oiling of fan, replacement of weak / unserviceable condensor etc at site and to make the fan functional without taking down from ceiling complete all as specified and directed. Note:- Cost of condensor will be paid under relevant item separately.
S&F of blade assy of celling fan of 1200 mm sweep (set of three) complete all as specified and directed.
S&F in repairs switch piano flush type single pole one way 5 Amps complete all as specified and directed.
S&F in repairs switch socket combined outlet 6 pin flush type 15 Amp multipurpose complete all as specified and directed.
S&F of fan rod of length 2 feet complete all as specified and directed.
Taking down of geyser of any capacity any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new heating element of round/triangle for 1.5/2.0 KW, 230 volts to match with the existing system complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified and directed. Make: Danfoss / Ranco / Indfoss or equivalent as approved by GE.
Disconnecting, dismantling & taking up or down existing unserviceable geyser indication lamp of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new indication lamp (set of two) complete all as specified and directed.
Disconnecting and taking up or down existing unserviceable PVC connections of any description from geyser installed at site and supplying and fixing new 15mm PVC connection with steel reinforced pipe for hot water connection of length 450mm including rubber washers complete all as specified and directed.
M&L for geyer of capacity 25/50 ltrs for painting of the items given below of any description and in any position, by applying two coats of paint (DUCO) white by spray machine including preparation of existing decorated surfaces including writing MES No. in capital letters of height not less than 20 mm in the pattern and style all as specified and directed.
S&F in repairs of 3 pin plug top AC-230 V, 15 Amp complete all as specified and directed.
S&F of BLDC type ceiling fan sweep 1200 mm BEE 5 star rated without remote control type also including multistranded PVC wire for connection complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for concealed point wiring for one light/fan point with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping of size 25 mm , ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS multi stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be conclead in wall, duly painted with two coats of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coats of aluminium paint on internal surface including laminated hylem sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule. Rate includes chase cutting for concealed wiring.
All as per item No. 29.00 here-in-before but for one light point controlled by 2 way switches, with FRLS cables of 1.5 sqmm complete all as specified and directed.
All as per item No. 29.00 here-in-before but for 3 pin socket outlet, 5 Amp on the same board with other switches, complete all as specified and directed.
All as per item No. 29.00 here-in-before, but for 3 pin 5 Amp switch socket combination on independent board with other switch complete all as specified and directed.
All as per item No. 29.00 here-in-before, but for bell buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 Sqmm. complete all as specified and directed.
All as per item No. 29.00 here-in-before but wiring with 2.5 Sq mm FRLS multistranded copper conductor cable for 5/15 Amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item No. 29.00 here -in- before but wiring with 4.0 Sq mm FRLS multistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core, FRLS cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, ISI marked, drawn in existing concealed conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLS cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including new laminated hylem sheet cover of min 3.0 mm thick , ISI marked of Make" Hylem" of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer complete all as specified and directed for the following:- Note : Wiring to be done as per approved colour code.
(a) One light/fan point controlled by one switch.
(b) One bell point controlled by one bell Push
(c) One light point controlled by two 2-way switches.
(d) One 5 Amps socket out let point controlled by one switch on independent board.
(e) One 5 Amps socket out let point controlled by one switch on same board.
(f) All as per item 36.00 here-in-before but wiring with 2.5 Sq mm FRLS multistranded copper conductor cable for 5/15 Amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
(g) All as per item 36.00 here-in-before but wiring with 4.0 Sq mm FRLS multistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, including sunken box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface, including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per approved colour code.
(a) One light/fan point controlled by one switch.
(b) One call bell point controlled by one push button on the same board with other switces or independent.
(c) One light point controlled by two 2-way switches.
(d) One 3 pin socket outlet 5 Amps on independent board.
(e) One 3 pin socket 5Amp outlet on same board with other switch.
(d) All as per item 37.00 here-in-before but wiring with 2.5 Sq mm FRLS multistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
(e) All as per item 37.00 here-in-before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Polycarbonate switch piano, flush button, single pole, one way 5 Amp , 240 volts ISI marked complete all as specified and directed.
S&F Polycarbonate switch piano, flush button, single pole, two way, 5 Amp, 240 volts ISI marked complete all as specified and directed.
Supply and fixing polycarbonate ceiling rose, surface type, 3 terminal, 240 , ISI marked complete all as specified and directed.
Supply and fixing polycarbonate, socket outlet 2-in-1, 5 pin 5 Amps, 240 volts, flush type complete all as specified and directed.
S&F Polycarbonate switch socket combination, outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete all as specified and directed.
S&F Polycarbonate switch piano, flush button, single pole one way 15 Amp 240 volt ISI marked complete all as specified and directed.
S&F Polycarbonate socket, pianotype, flush button, single pole one way 15 Amp 240 volt ISI marked complete all as specified and directed.
S&F, stepped type electronic fan regulator, Delux model, 100 watt, 240V, flush type complete all as specified and directed.
Supply and fixing in lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings including 9 watt LED lamp, and all cnnected accessies complete all as specified and directed.
S&F for Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed.
S & F Bell push, flush type, SP, 5 Amp, 240V complete all as specified and directed.
Taking down old unserviceable sub main wiring of any size and any description all as directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as earth continuity conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed.
Taking down old unserviceable TPN / SPN, MCB DB's incl MCB of any size and any discription complete all as specified and directed.
S & F sheet metal enclosure for MCB, DB, TPN 415 Volts, 200 Amps rated busbar 4 way double door, factory made conforming to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link and 200 Amp , 440 volt rated bus bar suitable for mounting 63/100 Amp MCC DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere, IP 43 protection class. DB shall also be provided with lable marking indicating the incoming and outgoing circuit complete all as specified and directed.
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 Amps rated busbar 4 way, double door ( Vertical DB with MCB as incomer) factory made conforming to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel , neutral link and 200 Aamp , 440 volt rated bus bar suitable for mounting 63/100 Amp MCCB as incomer. DB shall be semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003) and baked at high temperature with anti rust conditoning protection against corrosive atmosphere. DB shall also be provided with lable marking indicating the incoming and outgoing circuit IP 43 protection class complete all as specified and directed.
S&F MCB/MCCB TPN 100 Amps, 'C' Curve, breaking capacity 10 KA, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in MCB/MCCB TPN 63 Amps, 'C' Curve, breaking capacity 10 KA, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated busbar, 12 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated busbar, 8 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated busbar, 4 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 Amps rated busbar, 2 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed.
S&F MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F MCB, SPN 5 to 32 amps 10 KA , 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F of MCB, TPN 40 to 63 Amps, 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F of single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V with one single pole MCB of capacity 20 Amps having, 'C' curve, breaking cap 10 KA, including industial plug top, complete all as specified and directed.
S&F in repairs LED tube light box type highly durable surface mounted LED batten constructed of fire retardant engineering grade extruded plastic and decorative end caps. 22/25 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, system luminious efficiency> 100Lm/W, approx length 4 feet to be fixed in existing or new batten including taking down of existing tube light fitting and changing the wiring suitable for T8 LED tube light in existing tube light fitting including taking down existing fitting complete all as specified and directed.
M&L for earthing with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth wire of 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 SSR including earth pit in any soil charcoal common salt , 15 mm all around earth plate PCC (1:3:6) type culprit, with 40x40x6 mm angle iron frame and PCC cover (1:2:4) type B1, water pipe funnel and GI protection pipe light grade 15mm dia upto panel connecting earth lead to panel complete all as specified and directed. Note : Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate.
S&F of galvanised steel tubing, light grade, 40 mm dia fixed/ laid on floor/wall fixed with including GI clamps complete all as specified and directed.
S&F of galvanised steel tubing, light grade, 50 mm dia fixed/ laid on floor/wall fixed with including GI clamps complete all as specified and directed.
S&F of galvanised steel tubing, light grade, 15 mm dia for protection of GI wire fixed/ laid on floor/wall fixed with including G I clamps complete all as specified and directed.
M&L of earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer complete all as specified and directed.
S&F of bulk head luminare weather proof, including LED lamp 9W and connecting with copper flexible three core 23/0.0076 and all necessary fittings complete all as specified and directed.
M&L for cutting PCC/floor/road for taking out/ laying of cable, GI earth wire etc in protection pipe and making good, including material as per existing after laying of pipe for cable protection, GI wire etc and size of trench not more than 0.30 x 0.30m complete all as specified and directed.
Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm, 2 core nominal cross section in service connections including taking down old cable complete all as specified and directed.
Taking down unserviceable cable any type, any size and Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 16 Sqmm, 4 core nominal cross section in service connections complete all as specified and directed.
Taking down unserviceable cable any type, any size and supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 25 Sqmm, 4 core nominal cross section in service connections complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out complete all as specified and directed.
Returning filling in including spreading, leveling and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand filling in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and directed. Note:-Punned thickness only measured for payment.
M&L for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
Taking out old building security light and S&F of building secutity light including GI Pipe of approx 1 mtr length and suitable size of led light of capacity 25 watt including weather protection cover nut , bolt and connected accessories complete all as specified and directed.
S&F in repairs single phase direct connection type KWH meter, temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conforming to IS 13779, IP 54, with (parameters to show Date, time, current reading, KW, PF) in existing position by providing wooden board wooden board first quality of size 250 mm x 300 mm, including making elctric connections complete all as specified and directed. Make : Secure/HPL/ L&T or equivalent as approved by GE. Note : Old meter to be deposited in AGE E/M store.
S&F in repairs three phase direct connection type KWH meter, temper proof, plastic body with LCD display, 230/240V per phase, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with (parameters to show date, time, current reading, KW, PF) in existing position by providing wooden board wooden board first quality of size 250 mm x 300 mm, including making elctric connections complete all as specified and directed. Make : Secure/HPL/ L&T or equivalent as approved by GE. Note : Old meter to be deposited in AGE E/M store.
S&F of LED tube light of 20/22 watt T-8 type, 220 volt, 50 Hz, one side connection including connecting wire of Approx 0.6 mtr, nut, led lamp, wire all connecting accessories complete all as specified and directed.
S&F of 9 Watt LED bulb, 220 volt, 50 Hz complete all as specified and directed.
S&F of cable 1 Sq mm X 3 core suitable flexible wire FRLS for 220 volt, 50 Hz complete all as specified and directed.
S&F of hanging rod of 1 or 2 feet sizes for fan, rubber type, suitable for hanging ceiling fan, complete all as specified and directed.
S&F of MS screws of required sizes for mounting / tightning electric boards, complete all as specified and directed.
Supply and replacement of 3 pin plug top AC-230 v 15 Amp. complete all as specified and directed.
Supply and replacement of 3 pin plug top AC-230 v 5 Amp. complete all as specified and directed.
S&F of 1 Sqmm x 3 core mutistranded copper conductor flexible wire, suitable for 220 Volts, 50 Hz, complete all as specified and directed.
S&F in repairs laminated hylem sheet cover, ISI marked of Make "Hylem" cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in location with new galvanised screw and cup washer complete all as specified and directed for following sizes:
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
S&F of cable 2.5 Sqmm X 1 core suitable FRLS for garden light 220volt, 50 Hz complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 126815.00
ELITE WORKS
UMESH ENTERPRISES
M/S Shanti Enterprises
M/s logitech solution
M/S SURINDER KUMAR MAHAJAN
M S MEWALAL UPADHYAY
M/s VIKAS TRADERS
MODI CORPORATION
M/S J J ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .