Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC 23609 A INDERJEET SINGH BATH MANSA ROAD NEAR I T I CHOWK BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.6 L+₹69,410 (36.0%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹2.6 L+₹71,400 (37.0%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹7,100
Closing Date
6 Aug 2022, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
SOIL INVESTIGATION FOR CONSTR OF (PROVN OF OTM ACCN FOR SUP DEPOT (PH-I OF TWO PHASES) TYPE B AT MIL STATION AT SRI GANGANAGAR AND PROVN OF MULTI PURPOSE SHED IN KLP AT MIL STN FAZILKA
2022_MES_540219_1
GE SGNR/ JOB-02 OF 2022-23
Open Tender
Job Works
Item Rate
30 days
GE Sri Ganganagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹7,100
Yes
2 Sept 2022
22 Jul 2022
8 Aug 2022
22 Jul 2022
6 Aug 2022
23 Jul 2022
Amount
Bore hole dia shall be 150mm. depth of bore shall be decided as per the site condition and may be taken 15 m for N value reaches 50, whichever is earlier. Note : Under this test preferably following results to be provided : (i) Grain size analysis, identification & classification of soil. (ii) Unit weight (bulk density), natural moisture content, liquid limit , plastic limit, Shrinkage limit, Plasticity index, specific gravity. (iii) Dry density, degree of saturation of soil. (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear parameters (C-Ø analysis). (vi) Consolidation test & Permeability test. (vii) Depth of water table below ground level. (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specified in table-1 of IS 1893 (Part-I) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0 m interval. (xi) Reccomendation for filling under floor and filling under protection including plinth protection. (xii) For open foundation, calculation of net SBC at 1.5 m, 2 m, 3.0 m from shear as well as settlement criteria. SBC values shall be calculated based on C-Øanalysis as well as SPT value. For calculation formula given in IS 6403 shall be used. (xiii) if pile foundation are required the depth of pile shall be mentioned and pile capacity in compression, uplift & lateral load shall be given for 300, 400, 450, 500 dia for underreamed piles & for 450, 500, 550, 600 mm dia for long piles. (xiv)Recommendations regarding type of foundaion to be adopted & net SBC/pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil and soil stabilisation required, if any (xv) Borehole position duly marked on plan and their distances from adjacent prominet reference points. Plan size of bldgs shall also be marked in the plan. This plan shall be signed by GE,AGE & soil consultant. (xvi) Undisturbed soil sample shall be collected at 1.5 m interval and at change of strata. K-value of soil 0.5 m depth required in case of swimming pool and water retaining structure. Modulus of subgrade reaction , Direct shear test on dusturbed soil sample(xvii) Submission of report in sextriplicate. Note: Colour photograph on A4 size paper of the site with the locations of the boreholes duly flagged should be submitted. The photographs should also preferably include any reference structree and the identification of the same be marked
Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation complete all as specified and directed by Engineer-in-Charge
Chemical analysis of ground water (water to be obtained from bottom of bore hole). complete all as specified and directed by Engineer-in-Charge
Tri axial shear test on undisturbed soil sample (Unconsoliated undreained, Consolidated, consolidated drained test) complete all as specified and directed by Engineer-in-Charge
Conducting Geo Technical Investigation standard pentration test for record the actual N- Values for calculating SBC and collection of undisturbed disturbed samples for determining the engineering properities and also recommended for the type of foundation at several depth upto 10 mtr depth at Mil Stn Fazilka complete and Submission of report in sextriplicate all as specified and directed by Engineer-in-Charge
Research and Engineer Enterprises
National Soil Testing and Research Laboratories
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .