| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.3 L+₹2.1 L (18.9%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹14.0 L+₹2.9 L (25.8%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹14.8 L+₹3.6 L (32.5%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L4 | Rejected-Finance Being L4 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
10 Aug 2020, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Mohanbari
GE (AF) Mohanbari
COMPLETION OF INCOMPLETE WORKS AGAINST REPAIR/MAINT AND REPLACEMENT OF LT DISTRIBUTION AND CONTROL SYSTEMS AND OTHER CONNECTED ACCESSORIES AT AF STN DINJAN UNDER GE AF MOHANBARI.
2020_MES_358838_1
NIT No . 8001/248/01/E8 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFS Dinjan
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Mohanbari
₹20,000
Yes
17 Oct 2020
7 Jul 2020
13 Aug 2020
7 Jul 2020
10 Aug 2020
27 Jul 2020
60 days
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations of poles, /taking out/ laying of cable/ pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5 m in depth for foundations of poles/ stay wire set etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for Plain Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations of pole/ stay , filling and mass concrete complete all as specified.
Material and labour Plain Cement concrete 1:2:4 type B-1, (using 20mm graded stone aggregate) in foundations, filling and mass concrete as in coping including necessary formwork in finished surfacecomplete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed .
Material and labour for laying well burnt old size bricks, having compressive strength 75Kg/sqcm, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Laying only old burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Boring/Drilling ( horizontally) manually under existing road , pavements, hard standing ( maximum 10 M in width) suitable for passing GI tubing of 40 to 150 mm bore complete all as specified.
Supplying and fixing in repairs 40 mm bore dia, galvanised steel pipe /tubing, light grade complete with all fittings, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Supplying and fixing in repairs 50 mm bore dia, galvanised mild steel pipe /tubing, light grade complete with all fittings, laid in trenches / under roads, fixed to poles/ walls with mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Material and labour for disconnecting unservicable under ground LT cable of any size/type from existing pole or building or any location including removing of dismentalled material from work site complete all as specifoed and as directed
Supply and Laying LT under ground XLPE cable of size 10 sqmm, 2 core including testing and commissioning insulated, screened, PVC bedded, armoured steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specifoed and as directed Note:- Excavation,sand cushioning,brick will be measured and paid separtely.
All as per Item No.14 above but size 16 Sqmm, 4 core
All as per Item No.14 above but size 25 Sqmm, 3.5 core
Dismantling taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and as directed by Engineer-in-Charge. Note - Cost of cutting of bolts (Slag bolts) if reqd shall deemed to be included in the unit rate quoted for this item.
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nuts, bolts, washers , welding, bending, cold or hot , drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zinc Chrome and two coats of synthetic enamel paint all as specified.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, TPN (4 Pole), 63 Amps, 50 KA breaking capacity, with overload and thermal tripping feature, 415 Volts AC 50 Hz, ICU=100%, including certain addition or alteration if required at site complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, TPN (4 Pole), 200 Amps, 50 KA breaking capacity, with overload and thermal tripping feature, 415 Volts AC 50 Hz, ICU=100%, including certain addition or alteration if required at site complete all as specified and directed
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panels etc. MCCB, TPN (4 Pole), 400 Amps, 36 KA breaking capacity, with overload and thermal tripping feature, 415 Volts AC 50 Hz, ICU=100%, including certain addition or alteration if required at site complete all as specified and directed
Supply & fixed in repairs Stay Assembly complete with accessories as shown in electrical plate No.1 ( loop type insulator, stay clamps, excavation and concrete measured separately) 20 mm dia GI stay stay rod complete all as specified.
Supply and fixed in repairs Insulator loop type insulator, vitreous porcelain, white , brown or 'green', large size, with overall dimensions 90x140 mm, clearance of hole 25.5 mm, brown or green, complete all as specified.
Supply and fixed in repairs Shackle type, Porcelain vitreous , white, brown, white or green insulator including galvanised mild steel straps washers, insulator bolts, washers and nuts ; 1100 Volts working pressure, 100 mm height, 115 mm Maximum dia., with 31x5 mm galvanised steel straps and 14 mm dia. of bolts complete all as specified.
Supply and fixed in repairs Insulator Pin type, pocrcelain , vitreous, white , brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut , 100 mm height, 65 mm dia. For 1100 volts grade complete all as specified.
Supply and fixed in repairs PVC separator, sprial type in position for four wire ACSR conductor LT OH line complete all as specified.
Supply and fixed in repairs PVC separator, sprial type in position for two wire ACSR conductor LT OH line complete all as specified.
Restreching only existing LT OH/ HT OH lines consisting following lines of ACSR and GI wire , any size and tightening with aluminium binding wire of suitable size complete all as specified and directed . (a) 4 Lines of ACSR and 2 line of GI wire Note :- (i) Linear length centre to centre of the poles shall only be measured ) (ii) Cleaning/pruning of tree branches falling around the conductor shall also to deemed to be included in the quoted rates. (iii) Payment shall be made for linear length of poles as one span.
Restreching only existing LT OH/ HT OH lines consisting following lines of ACSR and GI wire , any size and tightening with aluminium binding wire of suitable size complete all as specified and directed . (a) 2 Lines of ACSR and 2 line of GI wire Note :- (i) Linear length centre to centre of the poles shall only be measured ) (ii) Cleaning/pruning of tree branches falling around the conductor shall also to deemed to be included in the quoted rates. (iii) Payment shall be made for linear length of poles as one span.
Supply and fixed in repairs galvanised steel wire 4 mm dia. complete all as specified.
Supply and fixed in repairs Cradles, hexagonal/ rectangular, fabricated with galvanised steel wire 4 mm dia. complete all as specified.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint \, including taking out of existing unserviceable pole and removing from work site complete all as specified and directed.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-22 ( 8.50 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint \, including taking out of existing unserviceable pole and removing from work site complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for earthing complete with copper galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply and fixed in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation of size 32x6 mm galvanised iron strip complete all as specified and directed .
Supply and fixed in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation of size 4mm dia GI wire stripcomplete all as specified and directed .
Supply and fixing in repairs of insulated synthetic mat suitable for 1100 volts working pressure of size 2000 mm x 1000 mm x 12 mm thick including taking old worn out insulated mat from various locations of E/M installations all as directed and specified.
Servicing and overhauling LT ACB current rating from 600 amps to 1000 amps of any type, make and taking out faulty ACB from existing LT panel/LT feeder pillar box by disconnecting all electrical and mechanical connections. Finding fault by dismantling parts, cleaning by cleaning agent, repairing/ replacement of faulty parts and refixing to its original position duly rectified the fault, calibration and testing complete in all respect or as directed or specified. NOTE:- (a) Minor spares such as cotton waste, On/off button & cover spring charge indication switch, trip indication swtich, grease, oil, lubricant, push button, cleaning agent deemed to be included in the quoted rates. (b) Major spares such as fixed contact, moving contact, IDMTearth fault/ over load relay to be measured and paid separately under respective Sch'A'' items as supply only.
Supply only of over load coil for LT ACB 600 Amps to 1000 Amps capacity.
Supply only fixed contact of LT ACB 600 amps to 1000 amps capacity.
Supply only moving contact of LT ACB 600 amps to 1000 amps capacity.
Supply only of IDMT earth fault relay complete
Supply only of IDMT over load relay compelte
Supply and fixed in repairs shock treatment chart duly framed in wooden frame made out 2nd class hardwood of cross-sectional area 25 sqcm, including varnish polished and glass cover size 75 cm x 50 cm, 4mm thick duly described in English/Hindi/Assami complete.
Supply and fixed in repairs first aid kit box size not less than 600 mm x 450 mm x 300 mm depth, made out of aluminium sheet complete with locking arrangements and with all medicines. bandage, burncare etc.required for first aid at electric supply installations all as specified..
Supply and fixed in repairs notice board made out of softwood duly framed in wooden frame size 1800 mm x 1200 mm, 20 mm thick and boardering with soft wood batten duly polished complete for electric supply installations all as specified.
Supply and fixed in repairs Installation signage board made out of two pieces of stainless steel Grade 304 H tubing nominal outer dia of 50mm (2") diameter each tube having 300 cm in length and 3x4mm retrofit reflecting tape both side printed complete all as specified.
Less Schedule of credit Bidder are requested to quote same rate inserted in estimate cost col 6 for credit items. Refer Schedule of credit
M/s PRABIR ENTERPRISE
M/S S. P. ENTERPRISE
S K ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .