Supply, installation, testing and commissioning of Telecom material in connection with Ratlam Division: Upgradation, augmentation and replacement of Telecom passenger amenities and Information System to facilitate Divyangjan at Chittaurgarh, Ratlam and Dewas station.
SnT-RTM-25-Tele-13~WR
SnT-RTM-25-Tele-13
Open
Works - General
10 Months
Chittorgarh, Rajasthan
₹0
₹3.3 L
29 Dec 2025
4 Dec 2025
15 Dec 2025
1-XS-NS Schedule
Item Breakup - 1-XS-NS Schedule
Supply of PVC insulated flexible 3 core x 2.5 Metre sq.mm multi strand power cable as per specification no. IS: 694:1990 reaffirmed 1995 or latest RATLAM DIVISION-S AND T/WESTERN RLY
Supply of Central Data Controller Unit Set conforming to system requirement as per RDSO /SPN/TC/ 108/2019 ver 1.0 or latest. The Control Console shall have Main and standby CPU to work in stand by mode one no UPS of 1 KVA with two independent batteries Two LCD Monitor (19) CCU Rack KVM Switch CDS (Layer 3, 12 port Switch) and other accessories housed in a standard size cabinet along with driving software for IPIS as per RDSO specifications. This also includes supply and installation of SW for Announcement system with necessary interface and announcement recording (Hindi/English/local) fresh studio copy of voice files.) as per RDSO Specification No.RDSO/SPN/TC/108/2019 Ver.1.0 or latest (the same to be interfaced with existing audio and video system installed at the station)the software should support all types of display/announcement by merely adding necessary hardware in future (single/multiline arrival / departure train information display boards. (single sided/double sided) CGDB AGDB LCD/LED/Plasma TVs etc.
Supply of LED-based double-faced Coach Numbers guidance display boards suitable for 5-digit train numbers with all necessary accessories as per RDSO Specification No- RDSO/SPN/TC/108/2019 Ver-1.0 or latest.
Supply of Platform Data Controller as per Numbers RDSO Specification No- RDSO/SPN/TC/108/2019 Ver-1.0 or latest.
Supply of True color Indoor Video Display Numbers (IVD) of Pixel Resolution (WxH) 432x128 (6- line Single face) as per RDSO specification No. RDSO/SPN/TC/108/2019 Ver-1.0 or latest.
Supply of True color Outdoor Video Display Numbers (OVD) of Pixel Resolution (W x H)- 432x128 (6- line).Technical Specification as per RDSO/SPN/TC /108/2019Ver-1 or latest.
Supply of STP CAT-6 Cable (Shielded Twisted Metre Pair) STP compliant with latest EIA/TIA-568- B2-1. D- link, polycab, finolex, Molex or securenet mak
Supply of Fault Analyser Equipment.as per Numbers given technical specification
Supply of optical Patch cord cable (3 Meter Numbers long with connectors) as per RDSO specs no.RDSO/SPN/TC/69/2007 or latest
Supply of Microphone with cord & connector Numbers and conforming to as per technical specification.
Supply of 6 core armoured Mono mode OFC Metre cable as per specification
Supply of 19'' 24 U rack to accommodate Numbers amplifier with all accessories as per technical specifications
Supply of Galvanized Iron Hot dipped Powder Metre Coated Perforated Type Cable TRAY Size W100 mm H 50 mm 1.5 mm thick. Tray Material Specification should be as per EN ISO 1461
Supply of Modern Tool Kit (For OFC) Numbers consisting of Optical power meter, Multimeter As per Technical Specification attached RATLAM DIVISION-S AND T/WESTERN RLY
Supply of Permanently Lubricated (PLB) High Metre density polyethylene (HDPE) Telecom duct for use as underground cable conduits 40/33 mm as per RDSO specification No.RDSO/ SPN/TC/45/2013 Rev.2.0 amd 1 & 2 orlatest (Necessary coupler and bend included in above)
Supply of White PVC Pipe of dia 1 Inch of as Metre per Standard IS:9537 (Part 3) with Pipe length of 3 mtrs each (Bend and Eblow as per site requirement will be supplied along with pipe)
Supply of 9U Dust proof Cabinet with cooling Numbers arrangement as per Technical specification
Supply of 14" LCD/LED based UTS-PRS Numbers (Universal) fare repeater with facility of QR code display as per specification
Supply of Smart Television Tv 65 Inch LED Numbers Backlit as per technical specification with 3 Year OEM Warranty
Supply of Remote Craft Terminal as per Numbers specification
Supply of twin core shielded cable of size of Metre each core 24/36 SWG with standard colour (Red & Black) having screening coverage of 95% area of the sheath of the cable using braided copper conductors
Supply of Horn speaker with tapping, Numbers matching transformer and driver unit, make reputed as UHC-15XT of Ahuja make or superior
Supply of Rodometer (Distance Recorder) as Numbers per the technical specification attached
Maintenance Free Earth Electrode of length Set 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.
Supply of Telescopic Ladders 19.5 FT (6.0 Numbers Meter) Extension Portable, Telescoping Extendable Aluminum Ladder with stabilizer Bar, Ladder for official and Industrial use, 15 steps. Make/Brand : Athena creations, Easymove, Sumer
Supply of Portable Electric Drill machine with Numbers battery as per technical specification attached Total 25139984.42 Item- 2 B1-Execution items S No. Item Description of Item Unit Qty Rate Amount No
Installation, testing and commissioning of Set CDC set as per RDSO Specification No- RDSO/SPN/TC/108/2019 Ver-1.0 or latest.
Supply commissioning of RMS Server along with software as per RDSO Spec. No. RDSO/SPN /TC/108/2019 Rev .1.0 Or Latest.
Installation & commissioning of Double- Numbers Faced Coach Guidance Display Boards in shade area. This includes all required accessories required including hanging structure for fixing arrangements to commissioning the item. RATLAM DIVISION-S AND T/WESTERN RLY
Installation & Commissioning of double face Numbers coach guidance display boards /Speaker as supplied under schedule A in open area. It includes Supply hanging & Fixing arrangement of coach indication board/speaker along with hood (Cover shed) in open space (without shed area) 100 mm Dia (OD) & 15 feet's long G.I. to be erected with concrete foundation (1:3:6) of 3 Feet deep from platform level and on the pipe an angle to be fixed on G.I. pipe as per site condition. Contractor to supply all required materials with G.I. pipe & G.I. sheet of 2x3 which should be placed on the top of the board in open space as preapproval of site engineer with angle fastening and crow guard. (supply of G.I. pipe included in this)
Installation, testing and commissioning of Numbers PDC as per RDSO/SPN/TC/108/2019 ver 1.0 or latest.
Supply, Commissioning of Single line Double face train Arrival/ Departure display boards as per specifications RDSO/ SPN/ TC/ 108/2019 Rev.1.0 with Amdt-1 or latest. This includes all required accessories required including hanging structure for fixing Suitable clamping arrangements to commissioning the item.
Installation, Testing and Commissioning of Numbers True color Indoor Video Display (IVD) of size Pixel Resolution (WxH) 432x128 (6-line single face) with required Mechanical Structure and as per site condition and as per RDSO Spec RDSO / SPN / TC /108/2019 Ver. 1.0 or latest
Installation, Testing and Commissioning of Numbers True color Outdoor Video Display (OVD) of Pixel Resolution (W x H)-432x128 (6-line) with required Mechanical Structure and other accessories, as per site condition and as per RDSO/SPN/TC/108/2019 Ver-1 or latest, as per direction of site engineer.
Supply & Installation (Ahuja or similar) Numbers Amplifier 1000 Watt Specification: Type - Powered, Number of Channels-2, Inputs- 8 x Mic 0.8mV/4.7k Ohm, 3 x Aux 100mV/50 k ohm, 1 x Aux 250mV/50 k ohm, 1 x Line 1V/50k ohm, Outputs: Preamp 200mV/600 ohm, Line 1V/1k ohm, Signal to Noise Ratio (dB)-60 Power supply: AC: 220-240V 50/60Hz-48Volts , Tone Controls Bass: ±10dB at 100Hz, Treble: ±10dB at 10kHz, .
Supply & Installation of Weatherproof Self Numbers Amplified IP Speaker with mounting arrangement as per specification
Supply Commissioning of PA IP Controller (Itconsists of two ServersActive & redundancyServer in standbymode with licenses) asper specification
Splicing of fibres OFC Cable and making Numbers Splice joint with contractors own splicing machine (rate for single splice) RATLAM DIVISION-S AND T/WESTERN RLY
Removal of paver blocks/tilesand cutting of Metre trench acrosson platform for a depth of 15cm & width of 15 cm withmarble cutting machine &filling the trench after layingthe cables & restoring thesurface with original tiles with smooth finish as per instructions of site incharge at site. All the materials except pipe are to be arranged by the contractor at site the debris is to be cleared from platform to outside the station premises.
Supply, commissioning of UPS 5 KVA capacity with battery bank for 1 hrs backup (On-Line) at rated load & battery trolley as per specification no RDSO /PE/ SPEC/PS/ 0023, (Rev. '0') 2001 Amdt 4 or latest.
Fixing of tray for housing all type of telecom Metre cable. (All accessories required for fixing of tray is provided by the contractor)
Supply, Commissioning of GPS-based double-faced platform Clock as per RDSO/SPN/TC /62 / 2008 Rev.3 Amd 1 &2.0 or latest along with required SMPS charger and battery Backup of at least 180 Mins, along with other accessories.
Blowing of OFC through HDPE duct & Metre protective work (elicited in above item) already provided.Where it is not feasible to blow OFC due to curves road/track crossings bridges or for anyother reason OFC shall be drawn or laid manually as per standard procedure.All the equipments and machinery required shall be arranged by thecontractor at his own cost.In case OFC is to be laid adopting Direct in trench method then this item shall be paid as peraccepted rate of thisschedule.OFC and HDPE pipe shall be supplied by the Railway.Blowing/Laying shall bestarted from one end and each drum laying shall be monitored afterblowing/laying and before leaving the sitetrace/cable parameters for all the fiber/ conductors shall be taken from one central location by contractors engineer with his own OTDR optic talk set/ measuring equipments with railway engineer.
Laying of HDPE pipe as per approved cable Metre route plan in the excavated trench taking due care while transporting andlaying the same in the trenches or otherprotective works. Both the end of duct should besealed with end plugsbefore laying and should remain sealed till blowing is done.
Wiring drawing fixing laying and clipping of Metre all telecom cable/PVC Power cable in PVC pipe/duct/Casing caping with complete fitting as per the instruction of site Engineer
Installation of Universal Fare display System Numbers for UTS Ticketwindows compatible with all PRS& UTS thin client/ Dumb Terminalincluding all necessary material.
Supply, Installation, testing & commissioning Numbers of full HD large format display monitor (55"or higher) with HDMI & DVI Ports complete with all accessories and HDMI cables, remote controller as per RDSO SPN No. RDSO/SPN/TC/65/2021, Rev6.0 with amendment-1 or latest. RATLAM DIVISION-S AND T/WESTERN RLY
Supply Installation testing & commissioning Numbers of rack mountable 24 port manageable Layer 2 aggregate switch with 24 x GE SFP port and 4x 10GE SFP ports as per RDSO spec. No: RDSO/SPN /TC/65/2021 Version 6.0 with amend ment1or latest Clause 14.0(i). All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
Installation, commissioning of different types of speakers with supply of all necessary clamps, bolts etc. as per instructions of Site Engineer.
Supply and installation of 2-Way Compact PA Numbers Wall Speaker including necessary fixtures required for the work and fixing the same as per specification.
Shifting of Existing cable and fix in cable Metre tray at platform, Fob. Type of cables PIJF Cable, data cable, power cable, PA cable and other S&T cables.
Release of old and defective unused cable Metre from Plafform , Fob & Shed
Installation of Maintenance free Earth Set Electrode for Maintenance free earth spec of RDSO/SPN/197/2008
Supply and Installation of PA WALL SPEAKER Numbers including necessary fixtures required for the work and fixing the same.
Installation of accessories
Supply, installation and complete wiring of Numbers optical fibre cable termination box for 6 fibres complete with base housing, base mountings with fixing arrangement etc. & splicing of fibre with low loss of pigtail cables. Splice losses in no case should be more than 0.1 dB. Necessary 0dB connectors should be provided in OFC termination box Total 10219029.43
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .