| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.1 CrAccepted-AOC 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | ₹1.1 Cr | 1 | Accepted-AOC Being lowest |
| 2 | 2₹1.2 Cr+₹7.2 L (6.29%)Rejected-Finance D 89 SHASTRI NAGAR MEERUT 250004 | MEERUT | UTTAR PRADESH | 250004 | ₹1.2 Cr+₹7.2 L (6.29%) | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹1.4 Cr+₹22.6 L (19.9%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | ₹1.4 Cr+₹22.6 L (19.9%) | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹1.6 Cr+₹42.3 L (37.2%)Rejected-Finance | ₹1.6 Cr+₹42.3 L (37.2%) | 4 | Rejected-Finance Not being lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
5 Aug 2022, 6:00 pmClosed
HQ CWE AGRA
112 TAJ ROAD AGRA CANTT
SPL REPAIR TO BLDG NO. P-20 (M AND R GP) AND ADDN / ALTN TO BLDG FOR SWATHI UNDER GE (EAST) AGRA
2022_MES_529596_1
84230/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
MES contractors enlisted in Class B category a(i) and b(ii) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE EAST AGRA
₹2.0 L
Yes
22 Aug 2022
9 Jun 2022
13 Aug 2022
9 Jun 2022
5 Aug 2022
30 Jun 2022
9 Jun 2022 - 16 Jun 2022
Amount
Dismantling of aluminium partition of aluminium section including aluminium beads rubber gasket and 5 mm thick glass in upper portion and 12 mm thick prelaminated particle board in lower portion, complete all as specified and directed at site.
Re-fixing aluminium partition of aluminium section with 5 mm thick glass in upper portion and 12 mm thick prelaminated particle board, exterior grade in lower portion including new aluminium beads and rubber gasket complete all as specified and directed. (Old material as retrievd under item No.1 except new beads & gasket shall be reused).
S&F aluminium partition of specified aluminium section (83 x 44mm x 2 mm thick) including aluminium beads rubber gasket and 5 mm thick frosted glass in upper portion and 12 mm thick prelaminated particle board, exterior grade one side with decorative choice lamination & other side balancing white lamination in lower side portion complete all as specified and directed.
S&F anodized aluminium door & frame made out of 2 mm thick aluminium section including 5 mm thick tinted glass in half portion and in other half portion with 12 mm thick prelaminated particle board, exterior grade prelaminated one side with decorative choice lamination & other side balancing white lamination complete and fixed with anodized aluminium snap beading and rubber gasket, glazing clips, jointing clips, screws and 02 Nos of aluminium handle on each door shutter, aluminium anodized tower bolt 200 mm long 02 Nos on each shutter and mortice lock device complete with duble keys for each lock, 01 No hydraulic door closer for each shutter complete all as specified and directed with following specifications :- (a) Aluminium door frame = 101.50 x 44.45 mm (b) Aluminium style / top & middle rails of shutter = 83.5 x 44.45 mm (c) Aluminium bottom rail of shutter = 114.50 x 44.45 mm (d) Aluminium door frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed.
Taking down and refixing of aluminium door of size n.exc. 8 sqm Each in the same opening after easing and adjusting and made proper functional by cutting or adjusting of existing frame and refixing aluminium snap beading and rubber gasket etc and tightening of loose parts complete all as specified and directed.
M&L for PVC sheet laminated plain coloured 2 mm thick mottled finish, homogeneous flexible type laid with approved rubber based adhesive in flooring complete all as specified and directed.
M&L in repair of vitrified ceramic tile light shade 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bedding in CM 1:6 complete all as specified and directed.
M&L in repair coloured vitrified ceramic tiles 10 mm thick (Square/rectangular) of Dark Shade, polished, area of each tile n.exc 0.36 sqm, fixed in skirting / dado etc over & including 10 mm thick cement screed bed in CM 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match with shade of tiles complete all as specified and directed.
Taking down cement plaster on brick or stone walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
M&L for preparing old plastered or unplastered surfaces of walls by brooming down or by steel wire brushing scraping down smoke soot, moulds moss and efforescent salts and applying two coats of oil bound distamper complete all as specified and directed.
M&L for insulated PVC wall lining consisting of PVC insulated panel with wood grain printed PVC sheet having expanded polystyrene (EPS) stuck to 2 mm thick plain colour PVC sheet duly fitted into the wall including necessary fittings as per specification and drawing complete all as specified and directed.
M&L for 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per manufacturers instruction complete all as specified and directed.
M&L for excavating in soft / loose soil for post holes (or similar holes) each n. exc. 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete etc complete all as specified and directed.
M&L for mild steel hand rails, half round or other section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars, for door, balusters, nosing to steps including embedding in concrete and screwing etc wind ties for roof including securing bolts posts and structs in fencing incuding cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165(R) complete all as specified and directed.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E-250) grade A complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall / north light curve, fixed with self tapping screws complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillar etc complete all as specified and directed.
M&L for surface dressing n. exc. 15 cm deep in soft / loose soil complete all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth for foundation etc or depth for foundation etc or for shafts, wells, cesspits, pier holes etc n. exc. 10 sqm or plan and n. exc. 1.5 m in depth and getting out in any type of soil including for laying of cable complete all as specified and directed.
M&L for brick work with sub class B bricks old size straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles (square / rectangular) area of each tiles exc. 0.06 sqm but n. exc. 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over & including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for glazed Ceramic tiles,first quality( of approved class , colour and design/ shade ) of size 300X200X6 mm thick , as on vertical surface of walls ie skirting/dado etc over & including 10 mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles, complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick wall surface or concrete surfaces and finishing the surfaces even and fair without using extra cement (mixed with integral water proofing compound) as per manufacturer instruction complete all as specified and directed. Note :- WPC shall be measured and paid separately.
M&L for 20 mm thick rendering in CM (1:4) as bearing plaster on fair faces of brick work or concrete surface and finishing surface even and fiar complete all as specified and directed.
M&L for 5 mm thick rendering in CM (1:3) on fair faces of brick work or concrete surface of ceiling and finishing surface even and fair complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying three coats of white wash on wall complete all as specified and directed.
M&L for three coats of white wash on new plastered surfaces of ceiling including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement base paint over one coat of white cement primer including preparation of new or previously untreated surface of wall complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in roof kerbs, paddings, mud stops slightly chamfered or rounded in edges including required groove cutting and using water proofing compound as per manufacturer's instruction complete all as specified and directed. ( Note - WPC shall be measured & paid for separately).
M&L for applying 10 mm thick plaster in CM (1:4) using water proofing compound as per manufacturer's instruction complete all as specified and directed. ( Note - WPC shall be measured & paid for separately).
S&F of anodised aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and directed.
S&F in figured glass 4 mm thick, pin head type and glazing with oil putty in squares n. exc. 0.5 sqm in each pane complete all as specified and directed.
Returning, filling in any type of soil including spreading levelling watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed .
Removal of surplus excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
S&F three layered rotational moulded polyethylene water storage tanks 500 liter capacity (cylindrical vertical with closed top) with and including ball brass valves, high pressure with polythene float and fly nut complete screwed for 20 mm bore iron pipe or for brass ferrule, hoisted and fixed in position complete as specified in SSR Part I 2009 complete all as specified & directed.
S&F vitreous china wash down water closet pan (Pedestal pattern) with cast iron 'P' or 'S' trap with run lead joint including connection to trap and cistern and flush pipe (excluding flusing cistern ) and making good to disturbed surface of floor complete all as specified and directed.
S & F of plastic WC seat cover and mild steel chromium plated or aluminised hinging device etc complete all as specified and directed.
S & F of Flushing jet(health faucet) for pedestal pattern WC incl. flexible pipe and Brass Chcomium Plated nuts and bolts and water pipe of size 1150 mm long between stop valve & WC & fixed complete all as specified and drected.
S&Fof Vitreous China wash hand basin white flat back of size 550x400mm including brackets , 32 mm PTMT weste coupling and 32 mm PVC flexible waste pipe 800mm long complete all as specified and directed.
S&F of Toilet paper holder, brass chromium plated complete all as specified and directed.
S&F of PVC low level flushing cistern of 10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed.
S&F 20 mm dia steel water tubes medium grade galvanised with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 15mm dia steel water tubes medium grade galvanised, with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 15mm bore CP bib taps, cast copper alloy fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F 15mm bore CP stop cock, cast copper alloy fancy type, screwed down high pressure, screwed for iron pipe or for unions and fixed complete all as specified and directed
S&F 15mm bore CP pillar taps, cast copper alloy fancy type, screwed down high pressure, screwed for iron pipe or for unions etc and fixed complete all as specified and directed by EIC.
Supply & fixing PVC connections of 450mm long suitable for 15mm dia iron pipe incl PTMT nuts complete all as specified & directed.
M&L for re-inforced cement concrete 1:1.5:3 Type A-1 (using 20mm graded stone aggregate) (nominal mix) for slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies,deck slabs and in shelves etc complete all as specified and directed.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work n exc 200mm thick (Horizantal or sloping ) for flat fair finished surfaces complete all as specified and directed
M & L formwork to edges of concrete roofs exc 10cm and n. exc 20cm wide for fair finished surface complete all as specified and directed
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for 75 mm thick PCC (Cement concrete) 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection finished even and fair and making 50mm deep joints at every 3 metre interval and at every corner and filling the joints with bitumen of grade 85/25 and sand mixture 1:3 complete all as specified and directed
M&L borken stone or boulders hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base etc finishing surface even and rough using broom complete all as specified and as directed.
S & F PVC (SWR) floor trap, plain with grating including jointing with solvent cement (Diameter of outlet 75mm) complete all as specified and directed.
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
M&L for 100mm internal dia salt glazed stone-ware drain pipe Grade'A' laid in trenches and jointed complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded stone agg) as in concrete bed to drain pipe, 100mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete and laying beds to falls complete all as specified.
M & L for 40 mm thick damp proof course in cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) to horizontal or vertical surface including necessary formwork using water proofing compound as per manufacturer's instruction complete all as specified and directed. ( Note - WPC shall be measured & paid for separately)
M&L for Providing precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate ) set in cement mortar 1:6 in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex tones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
Dismantling asbestos cement (corrugated, semicorrugated sheet/ North light curve, Ridge etc.) sheets in roof coverings complete all as specified and directed.
Hacking out old broken glass (any thickness, size quality or description) from wooden or metal frames, glazed with putty or fixed with beads etc complete all as specified & as directed.
S&F of rough cast wired glass 6.4 mm thick exc 0.5 sqm but not exc 0.75 sqm in each panel and glazing with oil putty complete all as speified and directed
Dismentling wall and ceiling board or insulation board /slabs/blanket any description & any thickness including cover fillets complete all as specified and directed.
S&F in repairs 605x605mm snap grid of powder coated galvanized iron of angle of size 23mm x 23mm of 30 gauge (Perimeter), T section of size 23mm x27mm and main T 23mm x 35 mm of 30 gauge suitable for false ceiling including GI wire 4 mm thick @ 1200 mm centre to ceter both ways for hanging arragement complete all as specified and directed
M&L for 4 mm thick non asbestos fibre cement building plain boards fixed in ceiling or laid/inserted to timber/GI/aluminun frame cover fillet etc complete all as specified and directed.
Dismantling timber fillets below 40 Sq. cm in section and in any position complete all as specified and as directed.
M&L plain fillets square rectangular or triangular section exc 13 & n.exc 25 Sqcm 2 nd class hard wood clean sawn secured with nail or breads complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section framed work in any position complete all as specified and as directed.
M&L for second class hard wood (Sal wood) in scantling timber framed complete all as specified and as directed.
M&L for preparing surface of wood and wood based materials , new or old , of any description and girth , not otherwise described and treated with a coat of creosote oil complete all as specified and as directed.
M&L plain fillets square rectangular or triangular section exc 06 & n. exc 13 Sqcm of 2nd class hard wood clean sawn secured with nail or brads complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface n exc 10cm width or girth including preparation of new or previously untreated wood surfaces complete all as specified and directed
Dismantling of wrought iron of mild steel work of any description not otherwise poivided
Preparation of old steel surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint of any height complete all as specified and directed
S&F in repair Plain galvanised mild steel sheeting 1 mm thick in ridges , hips , valley gutters drip and straight flashings ( length and girth as fixed ) with grade of zink coating 275 including welded or soldered joints provided, complete all as specified and directed.
Taking down eaves gutters and rain water pipes ( any size or pattern ) including all fittings, heads ,shoes etc complete all as specified and directed.
S & F of PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall (200mm bore ) complete all as specified and directed.
S&F of PVC (SWR) bends any radius 200 mm dia complete all as specified and directed
M&L for MS angles (internal or external) or nozzle pieces (Out lets) thickness of MS sheet 1.25mm and dia 150 mm complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors / dados, etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for two coats of oil bound distemper over and including a coat of average 1mm thick cement base Birla wall care putty on new plastered surfaces complete all as specified and directed.
Preparing old plastered or unplastered surfaces of walls by brooming down or by steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and applying one coats of oil bound distamper complete all as specified and directed.
Material and Labour for preparation of old plastered or unplastered surfaces of wall including cornices, pillers etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply one coat of white wash complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
Taking down rolling shutters of size exc 06 Sqm but n. exc 15 Sqm each complete all as specified and as directed.
S & F 1.25 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, and choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
Taking down rolling shutters and re-fixing to its original position after cleaning all parts, straightening rails, changing of damaged strips, bottom rail, cover, ball bearing, guide rail, helical spring etc as required, greasing, oiling, servicing for smooth functioning of all parts complete all as directed for the following sizes :- Note: Lath strips, bottom rail, spring, gears, guide rail, cover, ball bearing etc. will be measured and paid seperately as supply only
Area of rolling shutter n.exc 10sqm each
Area of rolling shutter exc 10Sqm and n.exc 20 Sqm each
Supply only mild steel spring made out of 6mm to 11mm dia high tension steel wire confirming to IS 4454 having 65 to 100 helical for rolling shutter for smooth working condition complete all as specified and directed (dia of spring 100mm to 150mm)
Supply only gear box made out of 1mm thick mild steel sheet of existing size including painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Supply only 75mm wide laths strips 1mm thick for rolling shutter including mild steel clips at either ends duly painted with and including two coats of synthetic enamel paint (shades to match with the existing) over a shop coat of red oxide primer complete all as specified and directed.
Supply only mild steel bottom rail lock plate with two handles 150mm wide and 3mm thick including necessary locking arrangement on both sides and painting to bottom rail with and including two coats of synthetic enamel paint to match with existing over a shop coat of red oxide primer complete all as specified & directed.
Supply only ball bearing for rolling shutters complete all as specified and directed.
Supply only 65 to 75mm wide guide rail, 3mm thick suitable for rolling shutter complete all as specified and directed
Supply only 1mm thick top cover mild iron plain sheet for steel rolling shutters including necessary welding bending turning up mitred angles stopped ends etc complete all as specified and directed.
Demolition of concrete in any description and in any position (unreinforced) complete all as specified and directed.
Material and labour PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate in fillets junction of roof and parapet wall caving slightly chamfered or rounded complete all as specified and directed.
Supply and installation of high wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of 2 TR capacity mounted on wall complete all as specified and directed.
Supply, Installation, commissioning and testing of transformer copper wound step down 500 KVA out door type at no load 3 phase, 4 wire 50 HZ AC with oil immersed air naturally cooled (ON AN type) energy efficient level-2 (EEL2), with external cooling tubes / radiatiors, Double wound core type copper wound having no load voltage ratio corresponding to principal tapping delta connected primary side (HV Side) and star connected on secondary side (LV side) in accordance with vector symbol DYN 11 (Vector group - 4) with neutral brought out on LV side and having tapping on HV side for constant out put so as to altervary secondary voltage with from + 2 1/2 %, + 5% and +7 1/2 % in step to be changed by mean of manual off load tap changing arrangements complete confirming to IS-1180 Pt-I 2014 complete all as specified and directed. The transformer shall be complete with following fittings and accessories :-
(a) Oil conservator tank with filling hole and cap drain and oil level guage. (b) Silica gel breather with oil seal and first fill of dehydrating agent. (c) Pressure relief valve with automatic resetting arrangement after release of pressure – 01 Set. (d) Oil temperature indicator (gauge) having range 0-120 C with max reading 100mm dia with shut off valve between the conservator and main tank. (e) Adequate No. of thermometer pocket including one number for accommodating bulb type thermometer. (f) Drain cum bottom valve. (g) Top filter valve. (h) Prismatic oil level gauge. (j) Inspection cover. (k) Cover lifting lugs (l) Jacking and lifting lugs (m) Rating and diagram plate. (n) Separate neutral bushing brought out for earthing on LV side. (o) First filling of transformer oil confirming to IS : 335 – 1972. (p) Earthing terminals -02 Nos located on diagonally opposite transformer tank base including lugs (q) Cable box on HV side and LV side,
M&L for transformer platform of size 3.5m x 3.5m x 1.5m height comprising of PCC M-7.5 (1:4:8) type D-2 (nominal mix) (using 40mm gradred crushed stone aggregate) as in foundation, Brick work one brick thick using old size brick in cement mortar 1:6, 15 mm thick rendering in cement mortar 1:4 on all exposed brick surface finished smooth using extra cement, filling in approved earth, providing 150mm thick hardcore of broken stone or boulders of gauge n exc. 63 mm and 150mm thick RCC slab of M-15 grade (Nominal Mix) (using 20 mm graded stone aggregate) on top reinforced with 12mm dia TMT bars and finishing top surface with 15mm thick plastering in cement mortar 1:4 finished even and smooth using extra cement complete with steps including fencing with MS flat iron as per drawing No TD-699 sheet 1/1 complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables earthed (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm.complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sq mm complete all as specified and as directed.
M&L for steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm width upto 1.5 mtr above ground level, balance lenght to be painted with two coats of aluminium paint externally all as required at site complete all as specified and directed.
Supply and fix HT 11 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complete with 9 insulators of rating upto 200 Amps complete all as specified and as directed
Supply, laying, Jointing connecting LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 400 Sqmm 3.5 Core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed..
Supply, laying, Jointing connecting LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm 3.5 Core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply, laying, Jointing connecting LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 Core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply, laying, Jointing connecting LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 3.5 Core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode of size 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25 x 4 mm thick as main earthing strip by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover of PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with 8mm TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth strip protection pipe, complete all as specified and directed. Note : Earth lead & GI protection pipe up to 7.5 m shall be deemed to be included in quoted rate
Material and labour for earthing complete with copper earth plate electrode of size 600 mm X 600 mm X 3.15 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to Copper strip of size 20 x 3 mm thick as main earthing strip by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover of PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with 8mm TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 25 mm dia GI light grade earth strip protection pipe, Charcoal (small pieces)-250Kg, Salt (Crystal)-250 Kg, Magnesium suplhate (crystal) -100 Kg, Copper strip shall be brazed with copper plate electrode, Alternate layers of charcoal and salts should be laid in the earth pit on the top of copper plate at least 5 layers should be laid. complete all as specified and directed. Earthing to be done in presence of Engineer-in-Charge
Supply, installation , Testing and Commissiong indoor cubicle panel board for three phases, 4 wire , design verified as per IS/IEC 61439- 1& 2 for 415 Volts , 50 Hz rated fault level 65 KA with internal arc containment with IP-56 protection rupturing capacity at 415 volts , factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shade RAL -7035 provided with suitable gasket to make it dust/vermin proof and provided multifunctional digital panel meter with LCD display flush mounting type of size 96 mm X 96 mm, accuracy class 1, suitable for CTs with secondary current 5A and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete & general construction comprising of the following :- Note :- (i) The termination of LT cables in the panel will be through cable glands of appropriate size. (ii) The electrical connection of incoming switchgears & outgoing switchgears (ACB/MCCB’s) will be through copper strips bus bar of rating 1.5 times the current rating of respective switchgears. OUTER SHELL:- The outer shell shall be made out of 3.00 mm thick CRCA sheet steel and MS angle section 50 mm x 50 mm x 6 mm frame with front and back openable double door system lockable /openable by keys from both sides having flush pattern fancy locks with louvers and air vent gasket for natural flow of air `U' type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The dimension of the outer shell should be adequate to accommodate inner shell described below giving 75 to 100 mm space around & shall be fabricated in such a way that the complete inner shell alongwith its with its control gears & accessories could be taken outside without disturbing outer shell. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel, safety shall be made with degree of protection of outer shell shall be IP-56, Computer out self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided.
INNER SHELL :- Inner shell made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear, front & back openable single door system lockable /openable by key from both sides having chromium plated 19 mm dia fancy locks (02 Nos in each compartment) having louvers & air vent gasket fro natural flow of air, "U" type gasket shall be used to make the inner shell completely vermin proof & to accommodate incomer / outgoing MCCBs and electrical grade busbar with 65 KA short time current (rms) for 1 sec and 105 KA (Peak) rated dynamic short circuit with stand with heat shrinkable sleeves alonwith shrouds for joints & eath duly colour coded shall be mounted on suitable size "F" class insulator made of nonhygroscopic , noncumbustile , track resistance , high strength FRP/SMC/DMC material at an interval not less than 500 mm through out the length of the TPN busbar . The cubical incomer MCCB as wel las out going shall have copper TPN extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder, the extension links shall not be less than 300 mm long supported on suitable size "F" class insulator made of non hygroscopic , noncumbustile, track resistance , high strength FRP/SMC/DMC material having provision for termination of incomer and outgoing cables. All inter connections between the main busbar as well as outgoing feeder shall be arried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeder and should be insulated with heat shrinkable PVC sleeves. All control wires shall be with 2.5 sqmm multistranded copper conductor and shall be properly bunched , tied, ferruled for proper identification and crimped with adequate size of copper lugs. The cubical shall have a bottom channel of size 75 x 40 mm duly coated with zinc metal coating having thickness not not less than 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at the bottom . The inner shell shall be of powder coated Siemens grey structtural RAL -7032 shade. An inspection lamp LED 5 watt with movable non ferrous chromium plated arm fitted on top side of inner shell shall be provided . The degree of protection for inner shell shall be IP-42 and carry the following controls :-
METERING: Multifunctional digital panel meter with LCD display flush mounting type of size 96 mm X 96 mm, accuracy class 1, suitable for CTs with secondary current 5A. INCOMING: (a) Bus bar chamber comprising 4 Nos copper strip bus bars made of copper strip with current capacity 1200 A with 65 KA rated short time current (rms) for 1 sec & 105 KA (Peak) rated dynamic short circuit with heat shrinkable PVC sleeves alongwith shrouds for joints . (b) MCCB, 4 pole having current ratings 800 Amps, AC 415 Volts, with Icu= 50 KA , Ics = 100% of Icu, with microprocessor release and adjustable overload setting (Min 70% to 100%) as per IEC -60947-1 and 60947-2 standard and fixed magnetic setting, complete with spreader links. Qty - 01 No OUTGOING: (a) MCCB 4 pole having current ratings 250 Amps, AC 415 Volts, with Ics = 36 KA, Ics = 100% of Icu, with microprocessor release and adjustable overload setting (Min 70% to 100%) as per IEC -60947-1 and 60947-2 standard and fixed magnetic setting complete with spreader links. Qty - 03 Nos (b) MCCB 4 pole having current ratings 160 Amps, AC 415 Volts, with Ics = 25 KA, Ics = 100% of Icu, with thermal release and adjustable overload setting (Min 70% to 100%) as per IEC -60947-1 and 60947-2 standard and fixed magnetic setting complete with spreader links. Qty - 07 Nos All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
Supply & fix copper strip of size 20 mm x 3 mm buried in ground complete all as specified and directed
Supply & fix GI strip of size 25 mm x 4 mm buried in ground complete all as specified and directed
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying,of cable complete all as specified and directed. (Note :- Punned thickness of sand cushioning shall be measured and paid for)
M&L for Sub class ‘B’ old size bricks laid dry flat over the cable each other, length of cable equal to width of brick all as required complete all as specified and directed.
Material and labour for GI tubing light grade 50 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately ) complete all as specified and directed.
Material and labour for GI tubing light grade 100 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately) complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 ( using 20mm graded stone aggregate ) in coping of poles studs including form work complete all as specified and directed.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, of size 300mm x 180mm x 40mm, factory made, complete all as specified and directed .
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Supply and fixing disc type insulator, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type white/brown or green two -in-series assembly for tension with tension clamps for conductors of working pressure 11000 volts for HT overhead lines complete all as specified and directed.
Supply and fix lightening arrester non liner type confirming to IS No 3070 part I complete with all fittings, distribution class working voltage 11 KV with rated system voltage of 12 kv discharge capacity 10 KA suitable for 11 KV including making connections with over head line with ACSR conductor complete on poles complete all as specified and directed.
Supply and fix HT 11 KV out door type Drop Out fuse suitable for horizontal or vertical mounting rotating type complete with 6 insulators of rating upto 200 Amps complete all as specified and as directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and removing from site.
M&L concealed point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLS PVC insulated unsheathed cable with proper colour coding drawn in including stove enammelled steel conduit not less than 20 mm dia with all accessories and FRLS PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles complete all as specified and directed. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point controlled by one switch
(b) One 5 pin socket outlet 5 Amps on independent board complete all as specified and directed.
(c) One 5 pin socket outlet 5 Amps on same board complete all as specified and directed.
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
All as per item No 133 here in before but with cable size 4 Sq mm for one AC socket out let on 16 Amp independent board / AC point and multistrand insulated copper earth continuity conductor of size 4 sqmm complete all as specified and directed .
Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fix Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body complete all as specified and directed.
S&F piano type bell push 5 Amp 240 volt complete all as specified and as directed.
Supply and fix socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed.
Supply and fix socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
Supply and fix stepped type electronic fan regulator 100 W flush type on the existing phenolic laminated sheet etc. as reqd, complete all as specified and directed.
Supply and fix ceiling rose , PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
Supply and fix Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed.
Supply and fix call bell, Ding dong type, 230 volts AC single pole complete all as specified and directed
Dismantling and taking down tube light single/double of any wattage or size for repair or replacement of burnt / worn out accessories and re-fixing the same after repair complete all as specified and directed.
Supply and fixing in renewal ceiling fans copper wound complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed.
Supply and fix in renewal exhaust fan, copper wound heavy duty metal body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers, complete all as specfied and directed.
Dismantling, taking down exisitng ceiling fan and re-fixing & connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
S&F in repair sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug top with one SP MCB 20 Amp 240 volt complete all as specified and directed.
Supply & fix in repair of sheet metal enclosure Vertical TPN DB 8 Way as per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management, fully insu5lated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, With provision for 250 Amp MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 12 way with IP-54 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-54 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-54 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole, 250 Amps, 50 Hz, Icu=25 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
Supply and fixing in repair MCB SP 1 to 2 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repair MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repair MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repair MCB TPN 16-32 Amps, 415V 10KA 'C' curve and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repair MCB TPN 40-100 Amps, 415V 10KA 'C' curve and current carrying capacity in the DB complete with connection testing and commissioning. complete all as specified and directed.
S&F sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x1.5 sqmm and one single core PVC insulated multistranded unsheathed FRLS flexible copper conductor 1x1.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in concealed Steel Conduit not less than 20 mm dia including dismantling of old unsv submain wiring including taking down of existing unserviceable sub main wiring complete all as specified and directed. Note :- 3 run of 1.5 sqmm cable & 1 run of conduit shall be measured as one unit.
S&F sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x2.5 sqmm and one single core PVC insulated multistranded unsheathed FRLS flexible copper conductor 1x1.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in concealed Steel Conduit not less than 20 mm dia including dismantling of old unsv submain wiring complete all as specified and directed. Note :- 2 runs of 2.5 sqmm cable & 1 run of 1.5 sqm cable & shall be measured as one unit.
S&F sub Main Wiring with three single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 4x6 sqmm and one single core PVC insulated multistranded unsheathed FRLS flexible copper conductor 1x4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in concealed steel Conduit not less than 32 mm dia including dismantling of old unsv submain wiring complete all as specified and directed. Note :- 4 run of 6 sqmm cable & 1 run of 4 sqm cable & shall be measured as one unit.
S&F sub Main Wiring with three single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 4x10 sqmm and one single core PVC insulated multistranded unsheathed FRLS flexible copper conductor 1x6 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in concealed Steel Conduit not less than 50 mm dia including dismantling of old unsv submain wiring complete all as specified and directed. Note :- 4 run of 10 sqmm cable & 1 run of 6 sqm cable & shall be measured as one unit.
Supply and fixing as in renewal of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe not less than 32 mm or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mmGI Strip strip complete all as specified and directed.
Supply, laying, Jointing connecting LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 Core laid in trenches / on poles / walls / in ducts / passing through pipes and including clamping on wall / truss necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply and lay Tubes,'light grade' galvansized 25mm dia for cable protection with all fitting and fixed complete to walls and ceiling or laid in floors/road cutting / chasing and making good to disturbed surface crossing complete all as specified and directed.
Supply, installation , Testing and Commissiong indoor cubicle panel board for three phases, 4 wire , design verified as per IS/IEC 61439- 1& 2 for 415 Volts , 50 Hz rated fault level 65 KA with internal arc containment with IP-56 protection rupturing capacity at 415 volts , factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shade RAL -7035 provided with suitable gasket to make it dust/vermin proof and provided multifunctional digital panel meter with LCD display flush mounting type of size 96 mm X 96 mm, accuracy class 1, suitable for CTs with secondary current 5A and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete & general construction comprising of the following :- Note :- (i) The termination of LT cables in the panel will be through cable glands of appropriate size. (ii) The electrical connection of incoming switchgears & outgoing switchgears (ACB/MCCB’s) will be through copper strips bus bar of rating 1.5 times the current rating of respective switchgears.
INNER SHELL :- Inner shell made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear, front & back openable single door system lockable /openable by key from both sides having chromium plated 19 mm dia fancy locks (02 Nos in each compartment) having louvers & air vent gasket fro natural flow of air, "U" type gasket shall be used to make the inner shell completely vermin proof & to accommodate incomer / outgoing MCCBs and electrical grade busbar with 65 KA short time current (rms) for 1 sec and 105 KA (Peak) rated dynamic short circuit with stand with heat shrinkable sleeves alonwith shrouds for joints & eath duly colour coded shall be mounted on suitable size "F" class insulator made of nonhygroscopic , noncumbustile , track resistance , high strength FRP/SMC/DMC material at an interval not less than 500 mm through out the length of the TPN busbar . The cubical incomer MCCB as wel las out going shall have copper TPN extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder, the extension links shall not be less than 300 mm long supported on suitable size "F" class insulator made of non hygroscopic , noncumbustile, track resistance , high strength FRP/SMC/DMC material having provision for termination of incomer and outgoing cables. All inter connections between the main busbar as well as outgoing feeder shall be arried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeder and should be insulated with heat shrinkable PVC sleeves. All control wires shall be with 2.5 sqmm multistranded copper conductor and shall be properly bunched , tied, ferruled for proper identification and crimped with adequate size of copper lugs. The cubical shall have a bottom channel of size 75 x 40 mm duly coated with zinc metal coating having thickness not not less than 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at the bottom . The inner shell shall be of powder coated Siemens grey structtural RAL -7032 shade. An inspection lamp LED 5 watt with movable non ferrous chromium plated arm fitted on top side of inner shell shall be provided . The degree of protection for inner shell shall be IP-42 and carry the following controls :-
METERING: Multifunctional digital panel meter with LCD display flush mounting type of size 96 mm X 96 mm, accuracy class 1, suitable for CTs with secondary current 5A. INCOMING: (a) Bus bar chamber comprising 4 Nos copper strip bus bars made of copper strip with current capacity 1200 A with 65 KA rated short time current (rms) for 1 sec & 105 KA (Peak) rated dynamic short circuit with heat shrinkable PVC sleeves alongwith shrouds for joints . (b) MCCB, 4 pole having current ratings 800 Amps, AC 415 Volts, with Icu= 36 KA , Ics = 100% of Icu, with microprocessor release and adjustable overload setting (Min 70% to 100%) as per IEC -60947-1 and 60947-2 standard and fixed magnetic setting, complete with spreader links. Qty - 01 No OUTGOING: (a) MCCB 4 pole having current ratings 200 Amps, AC 415 Volts, with Ics = 36 KA, Ics = 100% of Icu, with microprocessor release and adjustable overload setting (Min 70% to 100%) as per IEC -60947-1 and 60947-2 standard and fixed magnetic setting complete with spreader links. Qty - 02 Nos (b) MCCB 4 pole having current ratings 125 Amps, AC 415 Volts, with Ics = 16 KA, Ics = 100% of Icu, with thermal release and adjustable overload setting (Min 70% to 100%) as per IEC -60947-1 and 60947-2 standard and fixed magnetic setting complete with spreader links. Qty - 13 Nos All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
mohanlal gupta
M/s SCHOLASTIC ENTERPRISES
M/S J J ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .