Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAdmitted-Finance | ₹43.5 L | L1 | Admitted-Finance |
| 2 | L2₹47.1 L+₹3.6 L (8.35%)Admitted-Finance | ₹47.1 L+₹3.6 L (8.35%) | L2 | Admitted-Finance |
| 3 | L3₹47.2 L+₹3.7 L (8.54%)Admitted-Finance | ₹47.2 L+₹3.7 L (8.54%) | L3 | Admitted-Finance |
| 4 | L4₹47.3 L+₹3.9 L (8.87%)Admitted-Finance C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | ₹47.3 L+₹3.9 L (8.87%) | L4 | Admitted-Finance |
| 5 | L5₹47.4 L+₹4.0 L (9.15%)Admitted-Finance | ₹47.4 L+₹4.0 L (9.15%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Bhuiya Construction L4 | MS AFTAB LASKAR L5 | M/S TAPAN KUMAR RAY L2 | M/S Goutam Chakraborty L7 | SURANA CORPORATION L1 | NAGALAND AGENCIES CO L6 | M/S R A ENTERPRISE L8 | M/S MANIK LAL GUPTA L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00E & M Division Items | |||||||||||
| 2.00 | Supply, installation, testing and commissioning of lightning protection system Early Streamer Emission (ESE) lightning protection Air terminal OPR (Optimized Pulse Rod) complies with 30Mtr radius NF C-17-102 standards complete all as OEM specification and directed by Engr-in-Charge.
Make – ABB Model OPR-60 and equivalent | 24 | Each | 54,200 ₹13,00,800 | 54,120 ₹12,98,880 | 54,000 ₹12,96,000 Lowest | 56,000 ₹13,44,000 | 82,000 ₹19,68,000 | 55,000 ₹13,20,000 | 56,000 ₹13,44,000 | 54,100 ₹12,98,400 |
| 3.00 | Supply and fix stainless steel 3M mounting mast plus 2 m, 30 mm dia with guy wire and base plate fabricated with support structure top of roof and guying kit provided with suitable mounting base plate having provision for fixing of optimised pulse rod and arrangement for down conductor of lightning protection system including all welding work and other fabrication as per sitre requirements all arrangement by contractor above 3mtr roof height all as OEM Specification and directed by Engr-in-Charge.
Make:- Cat Part No Mast 3 M & MAST 2M30 of ABB or its equivalent | 24 | Each | 14,500 ₹3,48,000 | 14,300 ₹3,43,200 | 14,000 ₹3,36,000 | 14,000 ₹3,36,000 | 10,500 ₹2,52,000 Lowest | 14,000 ₹3,36,000 | 13,600 ₹3,26,400 | 13,900 ₹3,33,600 |
| 4.00 | Supply, fixing, testing and commissioning of lightning stroke counter working electro mechanically without any power supply fixing on wall/piller as per site requirment Eqpt should have capacity of counting lighting stroke of 0.4 KA to 150 ka, all as OEM specification properly fixed on wall or pole with suitable clamps and directed by Engr-in-Charge.
Make- LS Counter of ABB or its equivalent | 24 | Each | 12,000 ₹2,88,000 | 12,500 ₹3,00,000 | 11,000 ₹2,64,000 | 12,800 ₹3,07,200 | 15,000 ₹3,60,000 | 11,000 ₹2,64,000 | 11,200 ₹2,68,800 | 10,900 ₹2,61,600 Lowest |
| 5.00 | Supply, fixing and laying of single core multi stranded copper cable down conductor of size 70 sqmm incl mounting accessories and clamps properly on wall/ piller with suitable fixing material all as directed at site. | 260 | RM | 5,000 ₹13,00,000 | 5,110 ₹13,28,600 | 5,100 ₹13,26,000 | 5,000 ₹13,00,000 | 1,800 ₹4,68,000 Lowest | 5,200 ₹13,52,000 | 5,100 ₹13,26,000 | 5,000 ₹13,00,000 |
| 6.00 | Supply, fixing & installation of Copper Strip of size 20mm X 3mm as a ring conductor network buried in earth 1 mtr below from surface all as directed at site by Engr-in -charge | 120 | RM | 2,000 ₹2,40,000 | 1,988 ₹2,38,560 | 1,900 ₹2,28,000 | 2,000 ₹2,40,000 | 1,100 ₹1,32,000 Lowest | 1,900 ₹2,28,000 | 2,100 ₹2,52,000 | 1,800 ₹2,16,000 |
| 7.00 | Supply fixing & Installation of test point terminal block made of gun metal or phosphorus bronze size 75mmX75mmX25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in -charge | 24 | Each | 1,500 ₹36,000 | 1,410 ₹33,840 | 1,360 ₹32,640 | 1,500 ₹36,000 | 1,100 ₹26,400 Lowest | 1,450 ₹34,800 | 1,550 ₹37,200 | 1,350 ₹32,400 |
| 8.00 | M & L for earthing complete with galvanised steel plate earth electrode 600mm X 600mm X 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 20mm X 3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar or CI Cover, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. | 24 | Each Job | 18,000 ₹4,32,000 | 18,566 ₹4,45,584 | 17,600 ₹4,22,400 | 18,000 ₹4,32,000 | 14,000 ₹3,36,000 Lowest | 17,600 ₹4,22,400 | 17,800 ₹4,27,200 | 17,500 ₹4,20,000 |
| 9.00 | M & L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including 20mm dia PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including one single core 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed.
Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. | 360 | RM | 455 ₹1,63,800 | 400 ₹1,44,000 Lowest | 550 ₹1,98,000 | 500 ₹1,80,000 | 585 ₹2,10,600 | 550 ₹1,98,000 | 580 ₹2,08,800 | 555 ₹1,99,800 |
| 10.00 | Supply, laying and testing in trenches or fixing on wall or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor size 16sqmm 4 core served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed complete as per specification properly clamps on wall and connection at end point with all legs ,glands etc complete all as specified and as directed by the Engineer-in-charge. | 320 | RM | 677 ₹2,16,640 | 711 ₹2,27,520 | 630 ₹2,01,600 | 700 ₹2,24,000 | 680 ₹2,17,600 | 659 ₹2,10,880 | 680 ₹2,17,600 | 611 ₹1,95,520 Lowest |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
3 Aug 2026, 6:00 pmClosed
GE SILCHAR
Office of the GE Silchar Masimpur
PROVN OF LIGHTING PROTECTION SYSTEM BY ESE (EARLY STREAMER EMISSION) AND CERTAIN MINOR WORK AT CIJW SCHOOL VAIRENGTE MIL STN
2026_MES_778109_1
8170A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Vairengte
Class D Category b i and other criteria as per NIT and Tender Doc
8 documents required · 8 mandatory
₹500
GE Silchar
₹87,000
Yes
20 Aug 2026
13 Jul 2026
6 Aug 2026
13 Jul 2026
3 Aug 2026
27 Jul 2026
13 Jul 2026 - 20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | E & M Division Items | - | - | - | - |
| 2 | Supply, installation, testing and commissioning of lightening protection system Early Streamer Emission (ESE) lightening protection Air terminal OPR (Optimized Pulse Rod) complies with 30Mtr radius NF C-17-102 standards complete all as OEM specification and directed by Engr-in-Charge.
Make – ABB Model OPR-60 and equivalent | 24 | Each | - | - |
| 3 | Supply and fix stainless steel 3M mounting mast plus 2 m, 30 mm dia with guy wire and base plate fabricated with support structure top of roof and guying kit provided with suitable mounting base plate having provision for fixing of optimised pulse rod and arrangement for down conductor of lightening protection system including all welding work and other fabrication as per sitre requiremnets all arrangement of contractor above 3mtr roof height all as OEM Specification and directed by Engr-in-Charge.
Make:- Cat Part No Mast 3 M & MAST 2M30 of ABB or its equvalent | 24 | Each | - | - |
| 4 | Supply, fixing, testing and commissioning of lightening stroke counter working electro mechanically without any power supply fixing on wall/piller as per site requirment Eqpt should have capacity of counting lighting stroke of 0.4 KA to 150 ka, all as OEM specification properly fixed on waal or pole with suitable clamps and directed by Engr-in-Charge.
Make- LS Counter of ABB or its equivalent | 24 | Each | - | - |
| 5 | Supply, fixing and laying of single core multi stranded copper cable down conductor of size 70 sqmm incl mounting accessories and clamps properly on wall/ piller with suitable fixing material all as directed at site. | 260 | RM | - | - |
| 6 | Supply, fixing & installation of of Copper Strip of size 20mm X 3mm as a ring conductor network buried in earth 1 mtr below from surface all as directed at site by Engr-in -charge | 120 | RM | - | - |
| 7 | Supply & Installation of Test point terminal block made of gun metal or phosphorus bronze size 75mmX75mmX25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in -charge | 24 | Each | - | - |
| 8 | M & L for earthing complete with galvanised steel plate earth electrode 600mm X 600mm X 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 20mm X 3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar or CI Cover, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. | 24 | Each Job | - | - |
| 9 | M&L Sub main wiring with single core FRLSH PVC insulated and unsheathed multistranded, FRLSH copper conductor cable 1100 volts grade drawn through and incl 20 mm size of of PVC conduit concealed in wall accessories and fittings on wall. Cable required for connection to DBs shall deemed to be including and shall not be measured separately. Earth wire shall run inside the conduit. (a) 02 runs 4 sqmm conductor cable and 01 run of 4 sqmm as earth continuity conductor complete all as specified and as directed by the Engineer-in-charge. | 360 | RM | - | - |
| 10 | Supply ,laying and testing in trenches or fixing on wall or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor size 16sqmm 4 core served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed complete as per specification properly clamps on wall and connection at end point with all legs ,glands etc complete all as specified and as directed by the Engineer-in-charge. | 320 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
8170A-TP.pdf
Tender Documents • 0.58 MB
BOQ_871469.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .