Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹16.4 L+₹3.0 L (22.0%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹16.8 L+₹3.4 L (25.1%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | Rejected-Technical 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | - | Rejected-Technical COMPLETE DOCUMENTS FOR UNENLISTED CONTRACTOR AS PER NIT NOT SUBMITTED. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
REPAIR/MAINTENANCE OF SUMMER APPLIANCES AT AF STN BKT
2023_MES_586335_1
8659/BKT/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹40,000
Yes
4 Jul 2023
18 Mar 2023
24 Apr 2023
18 Mar 2023
22 Apr 2023
11 Apr 2023
Amount
M& L for servicing including comprehensive maintenance of split and window air conditioning of 1.5 to 3 ton capacity at site by skilled mechanic with assiciated staff with process cleaning evaporator / cooling coil ,condensor coil by using pressure pump ,clear water with copper friendly chemical solution for removing complete dust, checking function of all components, rectifying defect with replacement of defective spare parts (if found),charging of gas ,welding brazing etc except compressor all as specified and directed NOTE;- (i) Spares shall be measured and paid seperately as 'Supply Only' under respective item of BOQ (ii) Complaints have to attend on day to day basis and regular visit of adequate mechanic during contract period to maintain above Nos appliances at the Stn in Tech and as well as Admin area. (iii) Payment for each job shall be made once only during currency of contract irrespective of attending / replacing defective parts at any time that will be paid supply only under respective item if not paid earlier. (iv) complaint for non function of ACs have to attend on same day and normal defects have to rectify within 24 hours ,major defects have to rectified within 4 days otherwise recovery shall be made @ Rs 500/ day of delay. (v) If repair to Acs are beyond at site, the rate quoted shall deemed to include for taking out & removing to workshop for repairs and refixing of AC complete. NOTE: The contractor shall visit the site and ascertain the present running conditions of Acs and quote the rate accordingly. Please note that nothing extra will be paid on this account
Supply only Starting capacitor 80-100 mfd for window/Split type room air conditioner complete all as specified and directed by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
All as per Item No 2 here-in-before but 4 mfd
All as per Item No 2 here-in-before but 6 mfd
Supply only Running capacitor 10 mfd complete all as specified and directed by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
All as per Item No 5 here-in-before but 20 mfd
All as per Item No 5 here-in-before but 36+5/6 mfd
All as per Item No 5 here-in-before but 45+5/6 mfd
All as per Item No 5 here-in-before but 50/55+5/6 mfd
Supply only Starting relay for 1.5 Ton window type AC complete all as specified and directed by Engineer-in-Charge Make : Renutrol / Indfoss
All as per Item No 10 here-in-before but for split type AC
All as per Item No 10 here-in-before but for water cooler
All as per Item No 10 here-in-before but for Refrigerator
Supply only Refrigerant gas R-22 [Make: Floron/ Mafron/ Retron]
Supply only Refrigerant gas R-410 a [Make: Floron/ Mafron/ Retron]
Supply only Refrigerant gas R-132a/ R-32 [Make: Floron/ Mafron/ Retron]
Supply only PVC braided flexible drain pipe 15 mm
Supply only PVC braided flexible drain pipe 20 mm
Supply only Plug Top 3 pin 220 Volt 5 Amp Make :- Anchor/Plaza/Havells
Supply only Plug Top 3 pin 220 Volt 15 Amp Make :- Anchor/Plaza/Havells
Supply only Industrial protected socket with cap and chain 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells
Supply only Industrial protected plug top 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells
Supply only Defrost timer for domestic refrigerator all as per sample and directed by Engineer-in-Charge Make : Samsung/Godrej/Whirpool
All as per Item No 23 here-in-before but Bimetal relay
All as per Item No 23 here-in-before but Defrost heater
All as per Item No 23 here-in-before but over load proection for refrigerator /dispensor
All as per Item No 23 here-in-before but PTC relay
Supply only Cable PVC insulated sheathed 3 core copper conductor size 40/0.0076 mm complete all as specified and directed by Engineer-in-Charge
All as per Item no 28 here in before but 3 core copper conductor size 70/0.0076 mm
All as per Item no 28 here in before but 3 core copper conductor size 110/0.0076mm
Supply only contactor single phase single pole 25 A ,220 Volt,50 Htz suitable for split AC out door unit complete all as specified and directed by Engineer-in-Charge
Supply only Indoor blower motor for Split type AC 1.5 Ton capacity as existing make & model at site
All as per Item No 32 here in before but for split AC 2.0 Ton Capacity
Supply only Blower motor for window type room air conditioner 1.5 Ton capacity as existing model at site
Supply only Blower motor for out door unit split type AC capacity 1.5 TR
Supply only Blower motor for out door unit split type ACcapacity 2.0 TR
Supply only Blower motor for Water cooler of any capacity
Supply only blower motor for Desert cooler Make : AUE / Universal / Khatain / Bajaj
Supply only blower motor for plastic body Desert cooler of Make- symphany/ Bajaj or as existing at site of superior quality 3 speed motor
Supply only air filter suitable for window type AC 1.5 Ton capacity all as per sample
Supply only air filter suitable for split type AC of any capacity
Supply only 15 mm dia PVC (heavy duty) pipe for desert cooler
Supply only 20 mm dia MS clamp (worm gear type) for PVC pipe
Supply only Blower fan blade complete for desert cooler Make:AUE/Universal/Khaitan/Bajaj
Supply only Push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler
Supply only Condenser line filter for window/split AC
Supply only Condenser line filter for Refrigerator
Supply only Condenser line filter for Water cooler
Supply only Submersible pump for desert cooler (in replacement) for lifting water upto 1.2 metre head. Make : Champian/Crompton Graves/Meghdoot/Usha.
Supply only Copper Pipe size 5/8"( with sleeves)
Supply only of Copper Pipe size 1/4"( with sleeves)
Supply only of Copper Pipe size 1/2"( with sleeves)
Supply only Copper Pipe size 3/8"( with sleeves)
Supply only insulation for copper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia
Supply only condenser fan suitable for Window type AC any capacity
Supply only condenser Fan Suitable for Split Type AC any capacity
Supply only blower for split AC 1.5 Ton capacity for indoor unit
Supply only blower for split AC 2 Ton capacity for indoor unit
Supply only Relay for voltage stabilizer 240 volts all as per sample
Supply only Volt meter 0-300 volts
Supply only Timer circuit for voltage stabilizer
Supply only Connector porcelain type for voltage stabilizer
Supply only 15 mm dia PVC connection to water coolers 450 mm long
Supply only container with heating element of cap 1.5 ltr for water dispensor
Servicing& cleaning of water cooler of any capacity and any make at site, cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condensor motor, blower fan, rectification of fault, replacement of spare and charging of gas as on required basis, connecting & testing on load for performance all as directed by Engineer-In-Charge Note : Spares shall be measured and paid separately as supply only under respective items of BOQ
Servicing & cleaning of refrigerator of any capacity any make model, cleaning the various components i. e Chiller tray, Shelves, Freezer door, Door Gasket, Door Lock, Bulb Holder & bulb and Food tray and replacemnt of minor spare parts complete all as specified and directed by Engineer-in-Charge Note : Spares shall be measured and paid separately as supply only under respective items of BOQ.
Servicing & cleaning of Deep freezer any capacity any make model cleaning complete all as specified and directed by Engineer-in-Charge Note : Spare shall be measured and paid separately as supply only under respective items of BOQ
Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparation of surfaces with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and oiling the pump & motor complete all as specified and directed by Engineer-in-Charge
Servicing of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, checking the control wiring, fan & motor, tullu pump & motor complete all as specified and directed by Engineer-in-Charge
S&FWood wool pad set suitable for desert cooler heavyy duty including dismantling the old unserviceable wood wool pad set all as directed by Engineer-in-Charge
Disconnecting, cutting and taking out unserviceable sealed unit compressor of window type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing at site for window type air condition 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed
All as per Item No 72 here in before but for split AC 1.5 Ton Capacity
All as per Item No 72 here in before but for split AC 2.0 Ton Capacity
All as per Item No 72 here in before but for Water cooler of storage capacity 40-80 ltr/ 60-120 Ltr
All as per Item No 72 here in before but for Refrigerator of capacity 195 Ltr NOTE FOR ITEM NO 72 TO 76 : The contractor shall visit the site and ascertain the make and model of Acs and quote the rate accordingly. Please note that nothing extra will be paid on this account
Re-winding of blower motor of desert cooler any capacity any make with super enameled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement GM bushes/bearing, fixing and testing on load complete all as specified and directed
S & F in repair Circuit board PCB of Split Type AC complete for 1.5/2.0 TR Split type A/C complete all as specified and directed
S & F in repair Circuit board PCB complete set for indoor & outdoor of inverter type Split AC of make Daikin/Carrier /Samsung/bluestar/LG as existing at site of capacity 1.5/2.0 TR Split type A/C complete all as specified and directed
Repair and maintenance of defective Circuit board PCB complete for 1.5/2.0 TR Split type A/C complete all as specified and directed
S&F Indoor unit of split type AC capacity 1.5 TR including copper evaporator coil ,blower ,blower motor,controling circuit of AC complete all as specified and directed . Make- LG,Carrier ,Daikin ,Samsung
All as per Item No 81 here-in-before but for Capacity 2.0 TR
Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5/2 Ton capacity and providing the new copper condensing unit of exsting size model in place including welding, brazing etc and testing on load complete all as specified and directed
All as per item No 83 here-in-before but evaporator coil
All as per item No 83 here-in-before but water cooler
Supply & Fix in repair wall mounted digital display voltage stabilizer copper winding, for automatic voltage correction single phase, naturally air cooled, indoor type, designed for input voltage between 140 Volt to 280 Volts and out put voltage 230Volt and High / low voltage cut off with facility of including instant start & time delay relay of 3 minute capacity 5 KVA complete all as specified and directed. Make : Blue Bird, Marc Arora, V guard, Microtek
All as per item no 86 here-in-before but 4 KVA
S&FSheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed Make Havells/Anchor/Legrand
Disconnecting ,dismantling and Taking out functional split AC and reassembling fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall including welding and brazing of copper pipe including charging of gas (if required) complete testing and making good to match with existing surface all as specified and directed by Engineer-in-Charge Note;- the rate for above item are deemed to include for necessary servicing cleaning & replacement of necessary u/s screw/nut/bolt/washer etc with new one,brazing of cooper pipe,transportation to any location inside AF campus complete all as specified and directed
M&L for repair to remote circuit complete with remote device for 1.5/2 TR window/split type AC and complete testing complete all as specified and directed
S&F in repair MCB protected socket combination including MCB of capacity 25 amps withsteel sheet/plastic enclosure with plug topAC 230 V complete all as specified and directed
S&F in repair MCB single pole, 20 to 32 Amps, 240 Volts 50 HZ, 'C" series 10 KA breaking capacity complete all as directed.
S&F Sheet metal enclosure TPN 4 way double door distribution board,415 volt all as specified and directed
S&F Sheet metal enclosure SPN 8 way double door distribution board ,415 volt all as specified and directed
M&L ,T & P for detecting & rectifying leakage in split type AC as required at site and charging of refrigerant gas (R-22 /32/ 134 (a) / 410 c ) including welding brazing as reqd complete all as specified and directed by Engineer-in-Charge. Note;-refrigerant gas shall be measured and paid seperately as 'Supply Only'
All as per item no. 95 here in before but for water cooler
All as per item no. 95 here in before but for refrigerator
Taking down old u/s M S bracket and S&F MS factory made bracket with powder coated, fixed on wall with necessary grouting MS bolt washer duly painted suitable for stalling outdoor unit of 1.5/2 tr AC complete all as specified and directed
M&L for submain wiring with two run of single core PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).Make of Cable - Havells,Plaza,Polycab.Make of Conduit - AKG,Finolex,Plaza
M&L for submain wiring with two run of single core PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 4 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).Make of Cable - Havells,Plaza,Polycab.Make of Conduit - AKG,Finolex,Plaza
M/s Hanspal Enterprises
ANUJ COOL ENGG. WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .