GEMC-511687760199814
Awarded to THE SERVICE POINT
₹93,000
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| MULTIPARA MONITOR 12.1 INCH | BPL ULTIMA PRIME D | - | 1 NOS | ₹93,000 | 93,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹93,000Qualified Make: BPL
Model: BPL ULTIMA PRIME D D 6 BDA DUPLEX NEAR RAILWAY TRACK ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: BPL
Model: BPL ULTIMA PRIME D | L1 | Qualified | |
| 2 | L2₹97,000+₹4,000 (4.30%)Qualified Make: BPL MEDICAL TECHNOLOGIES
Model: BPL ULTIMAPRIME D D 90 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 INDIA | LUCKNOW | UTTAR PRADESH | 226010 | Make: BPL MEDICAL TECHNOLOGIES
Model: BPL ULTIMAPRIME D | L2 | Qualified | |
| 3 | Disqualified Make: Mindray
Model: MINDRAY UMEC ARYA NAGAR HARIDWAR UTTARAKHAND 249407 INDIA | HARIDWAR | UTTARAKHAND | 249407 | Make: Mindray
Model: MINDRAY UMEC | - | Disqualified | |
| 4 | Disqualified Make: BPL
Model: C10W make BPL 255 A VIMAN NAGAR KANPUR KANPUR NAGAR UTTAR PRADESH 208007 | KANPUR NAGAR | UTTAR PRADESH | 208007 | Make: BPL
Model: C10W make BPL | - | Disqualified | |
| 5 | Disqualified Make: MEDIWAVES
Model: PM 5000 B 68 G T KARNAL ROAD INDUSTRIAL AREA DELHI DELHI DELHI 110033 | NORTH DELHI | DELHI | 110033 | Make: MEDIWAVES
Model: PM 5000 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
21 Jun 2018, 3:00 pmClosed
acute care monitoring units and related products- patient monitors Acute Care Monitoring Units And Related Products-patient Monitors ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values NEW SET Type of Monitor Modular - Functional Requirements: Operates from mains voltage or from internal rechargeable battery Operator can set audio visual alarm levels for low or high levels of each parameter independently Allows display of single
3 lead ECG or simultaneous display of at least 5 waves ECG selected from up to 12 points Display to be digital of all active parameters and trace display for at least three selectable parameters Yes - Clinical Purpose: Designed to continuously measure and display multiple vital physiological parameters of adults
YES - 1/7 newborn and premature infants
especially those under critical care Continuous display on screen of neonatal or infant ECG
respiration and heart rates
invasive/non-invasive blood pressure
body temperature and SpO2 Yes - Patient monitor offered with option to monitor parameter(s): Cardiac Output EtCO2
IBP
Cardiac Output Number of leads for ECG 3 3
5
12 Screen Size 12 8
12
14
15
17 Weight 8 - ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable
external skin contact type; Temperature range at least 30 to 40 deg C
minimum gradation (1/10) deg C/Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm and minimum gradation 1 bpm/SpO2 measurement range at least 40-70 % and 70 to 99 %
with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring Yes - 2/7 range at least 30 to 300 mmHg
minimum gradation 1 mmHg Respiration rate measurement range at least 0 to 100 bpm
minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable
with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg
minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable/TFT true - 3/7 Screen User Interface Manual through knob or key board Manual through knob or key board
Through touch Screen
remotely operated Audio Visual alarms high and low levels for each parameter (operator variable settings)
sensor/wire probe disconnected
low battery - Case is to be hard and splash proof/Display must allow easy viewing in all ambient light levels/Cable connectors to be designed so as fit correct socket only Yes - Noise (in dB) < 50 - Heat Dissipation: Should maitain nominal Temp and the heat should be disbursed through adequate arrangement - Mobility & Portability Fixed mounted usage - Power supply replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure) 220 volt
50 Hz AC
replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure)
Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt
50 Hz AC both Mains cable to be at least 3m length YES - Accessories & Spare Parts: pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature 4/7 probe probe Operating condition: apable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances - Should be FDA CE/BIS approved product European CE US FDA
European CE
BIS - Electrical safety conforms to standards for electrical safety IEC-60601-1/- Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility)/-Also conforms to IEC 60601-2- 27 (Particular requirements for the safety of electrocardiographic monitoring equipment) - Manufacturer supplier should have ISO certificate for quality standard/- Shall meet IEC 60601-2-49 multi function patient monitoring equipment standard requirement Yes - Seller to perform supply
installation
safety & operation checks and training before handover of the product [Training of users in operation and basic maintenance shall be provided] Yes - Warranty Comprehensive warranty of 3 years with free servicing ( min 3/year) during warranty - Operating manuals
service manuals
other manuals/documents Advanced maintenance tasks required shall be documented User
technical and maintenance manuals - 5/7 to be supplied in English language. List to be provided of equipment and procedures required for local calibration and routine maintenance List to be provided of important spares and accessories
with their part numbers. Certificate of calibration and inspection to be provided. Recommendations or warnings Any recommendations for best use and supplimentary warning for safety to be declared - Details of Item and test reports Availability of Test Report from Central Govt/NABL/ILAC/Any OPCW accredited lab to prove conformity to specification No - Test report (if indicated as available) to be furnished to buyer on demand YES - Test report No & date N/A - Name and address of the Lab: N/A - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Veerabasanagoud Patil 586121
NTPC LIMITED KUDGI SUPER THERMAL POWER PLANT 1 15 EMD Required No ePBG Required No
210515
GEM/2018/B/29969
GeM Contract
acute care monitoring units and related products-patient monitors
GeM Contract
15 days
Karnataka; Vijayapura
PRODUCT
Awarded to THE SERVICE POINT
₹93,000
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| MULTIPARA MONITOR 12.1 INCH | BPL ULTIMA PRIME D | - | 1 NOS | ₹93,000 | 93,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| acute care monitoring units and related products- patient monitors Acute Care Monitoring Units And Related Products-patient Monitors ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values NEW SET Type of Monitor Modular - Functional Requirements: Operates from mains voltage or from internal rechargeable battery Operator can set audio visual alarm levels for low or high levels of each parameter independently Allows display of single | - | - | - |
| 3 lead ECG or simultaneous display of at least 5 waves ECG selected from up to 12 points Display to be digital of all active parameters and trace display for at least three selectable parameters Yes - Clinical Purpose: Designed to continuously measure and display multiple vital physiological parameters of adults | - | - | - |
| YES - 1/7 newborn and premature infants | - | - | - |
| especially those under critical care Continuous display on screen of neonatal or infant ECG | - | - | - |
| respiration and heart rates | - | - | - |
| invasive/non-invasive blood pressure | - | - | - |
| body temperature and SpO2 Yes - Patient monitor offered with option to monitor parameter(s): Cardiac Output EtCO2 | - | - | - |
| IBP | - | - | - |
| Cardiac Output Number of leads for ECG 3 3 | - | - | - |
| 5 | - | - | - |
| 12 Screen Size 12 8 | - | - | - |
| 12 | - | - | - |
| 14 | - | - | - |
| 15 | - | - | - |
| 17 Weight 8 - ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable | - | - | - |
| external skin contact type; Temperature range at least 30 to 40 deg C | - | - | - |
| minimum gradation (1/10) deg C/Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm and minimum gradation 1 bpm/SpO2 measurement range at least 40-70 % and 70 to 99 % | - | - | - |
| with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring Yes - 2/7 range at least 30 to 300 mmHg | - | - | - |
| minimum gradation 1 mmHg Respiration rate measurement range at least 0 to 100 bpm | - | - | - |
| minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable | - | - | - |
| with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg | - | - | - |
| minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable/TFT true - 3/7 Screen User Interface Manual through knob or key board Manual through knob or key board | - | - | - |
| Through touch Screen | - | - | - |
| remotely operated Audio Visual alarms high and low levels for each parameter (operator variable settings) | - | - | - |
| sensor/wire probe disconnected | - | - | - |
| low battery - Case is to be hard and splash proof/Display must allow easy viewing in all ambient light levels/Cable connectors to be designed so as fit correct socket only Yes - Noise (in dB) < 50 - Heat Dissipation: Should maitain nominal Temp and the heat should be disbursed through adequate arrangement - Mobility & Portability Fixed mounted usage - Power supply replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure) 220 volt | - | - | - |
| 50 Hz AC | - | - | - |
| replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure) | - | - | - |
| Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt | - | - | - |
| 50 Hz AC both Mains cable to be at least 3m length YES - Accessories & Spare Parts: pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature 4/7 probe probe Operating condition: apable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances - Should be FDA CE/BIS approved product European CE US FDA | - | - | - |
| European CE | - | - | - |
| BIS - Electrical safety conforms to standards for electrical safety IEC-60601-1/- Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility)/-Also conforms to IEC 60601-2- 27 (Particular requirements for the safety of electrocardiographic monitoring equipment) - Manufacturer supplier should have ISO certificate for quality standard/- Shall meet IEC 60601-2-49 multi function patient monitoring equipment standard requirement Yes - Seller to perform supply | - | - | - |
| installation | - | - | - |
| safety & operation checks and training before handover of the product [Training of users in operation and basic maintenance shall be provided] Yes - Warranty Comprehensive warranty of 3 years with free servicing ( min 3/year) during warranty - Operating manuals | - | - | - |
| service manuals | - | - | - |
| other manuals/documents Advanced maintenance tasks required shall be documented User | - | - | - |
| technical and maintenance manuals - 5/7 to be supplied in English language. List to be provided of equipment and procedures required for local calibration and routine maintenance List to be provided of important spares and accessories | - | - | - |
| with their part numbers. Certificate of calibration and inspection to be provided. Recommendations or warnings Any recommendations for best use and supplimentary warning for safety to be declared - Details of Item and test reports Availability of Test Report from Central Govt/NABL/ILAC/Any OPCW accredited lab to prove conformity to specification No - Test report (if indicated as available) to be furnished to buyer on demand YES - Test report No & date N/A - Name and address of the Lab: N/A - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Veerabasanagoud Patil 586121 | - | - | - |
| NTPC LIMITED KUDGI SUPER THERMAL POWER PLANT 1 15 EMD Required No ePBG Required No | - | - | - |
Exempted
10 Jul 2018
14 Jun 2018
contract_GEMC-511687760199814.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_210515.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .