Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹13.7 L+₹14,326 (1.06%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹14.0 L+₹43,169 (3.19%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹14.0 L+₹47,680 (3.52%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹14.5 L+₹94,690 (6.99%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
11 Jan 2020, 2:00 pmClosed
MAJ ALIF MANSOOR
GARRISON ENGINEER MES NASIRABAD - 305 601 (Raj)
REPAIRS REPLACEMENT OF SECURITY LIGHTS HIGH MAST LIGHTS POST TOP LANTERNS AND CONNECTED ITEMS
2019_MES_302652_1
8866/E8
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
NASIRABAD
AS PER NIT
6 documents required · 6 mandatory
₹500
GE NASIRABAD
₹36,000
Yes
16 Jan 2020
30 Nov 2019
13 Jan 2020
30 Nov 2019
11 Jan 2020
3 Jan 2020
30 Nov 2019 - 7 Dec 2019
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00mtr in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in with excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles etc including weathering, slightly rounded or chamfered angles and throating as directed. including necessary form work complete all as specified and directed.
Dismantling concrete/steel pole 8/9 mtrs long with foundation and Supply & install of steel tubular swaged poles type 410 SP-31 (9.00 meters long) complete with cast iron base plate, finial taper plug,bolts, nuts & screw including 1.00 mtrs long 40 mm bore MS GI pipe mounting bracket made to shape for street light with and including MS end cap complete fix to steel tubular pole with bolts, nuts & washers inculding paint with two coat of aluminium paint over a coat of zinc chrome primer and two Nos of 25mm dia light grade pipe 0.3 M long for street light cable protection complete all as specified and directed byb Engineer-in-charge ( Excavation and earth work and PCC for foundation to be measured and paid for separately).
Dismantling carefully concrete/steel pole 8/9 mtrs long with foundation and transporting the same at new location within cantt area as directed by EIC & erect & install the same complete all as specified and directed ( Excavation and earth work and PCC for foundation to be measured and paid for separately).
M & L for zebra painting with two coats of Ist quality synthetic enamel on HT/LT steel tubular swaged pole up to 1.5 meter height from pedestal in 30 cm height in black and white paints for LT and red and white for HT including scraching out old paint, cleaning the existing surface rust free & preparation of steel surface and painting the balance portion of the pole, cross arms, clamps, channels and bolts and nuts with two coats of aluminium paint and including writing the pole Nos of 50mm height letters/ figures with luminous acrylic PVC strip "MES(HT/LT) ____" (pole number) & one coat of white wash on concrete surace complete all as specified & directed.
M&L for painting to the channels, cross arm, clamps of HT/LT PCC poles with strips in alternate from bottom to top (up to 1.5 Mtrs) with three strips of black synthetic paint & two strips of aluminium paint through out the circumference of pole (width of each strip shall be of 30 cm) including one coat of lime wash on PCC coping of pole and two coats of aluminium paint to channels, cross arm, clamps and pipe fixed/ mounted on pole after scraching out old paint, cleaning and making existing surface rust free, preparation of the existing surface including marking pole numbers /writing letters or figures (block,Roman not existing 30 cm high in a 20 cm dia yellow circle with number writting with black synthetic paint complete all as specified and directed.
Taking down existing street light fitting any type and S&F Integral LED Street light luminaire of 60 W, comprising of pressure die cast aluminium housing with toughened glass, cover IP 66 rating,secondary lens with light efficacy 110 LM/W, 6000k with external 10 KV SPD and ported driver and with all fixing arangement, nuts, bolts and washer connecting to electric system with 1.5 sqmm PVC aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion complete all as specified and directed. MAKES :- Cat part LSRTO1S060XC of Jaquar, SLEUL60WIP-66(LXN) (SURYA) Cat pat LSTP-60-CDL-M of Crompton or equivalent in Philips/Wipro NOTE :- (i) MAKE of LED fixture/fitting and driver should be of same manufacture/company (ii) NABL certificate will be required at the time of sample approval. (iii) warrenty certificate shall be required for minimum 3 years. (iv) LM-80 and LM-79 test reports shall be produced with sample approval.
Taking down existing street light fitting any type and S&F Integral LED Street light luminaire of 72 W, comprising of pressure die cast aluminium housing with toughened glass, cover IP 66 rating, secondary lens with light efficacy 110 LM/W, 6000k with external 10 KV SPD and ported and with all fixing arangement, nuts, bolts and washer connecting to electric system with 1.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion, complete all as specified and directed. MAKES :- Cat part LSRTO1S072XC of Jaquar, SLEUL70WIP-66(LXN) (SURYA), Cat pat LSTP-72-CDL-M of Crompton or equivalent in Philips/Wipro NOTE :- (i) MAKE of LED fixture/fitting and driver should be of same manufacture/company (ii) NABL certificate will be required at the time of sample approval. (iii) warrenty certificate shall be required for minimum 3 years. (iv) LM-80 and LM-79 test reports shall be produced with sample approval.
Taking down existing flood light fitting any type and S&F Integral LED flood light luminaire of 150 W with High pressure die cast housing with lens, IP -65 rating with external SPD 10 KV and ported driver with all fixing arangement, nuts, bolts and washer connecting to electric system with 1.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion, complete all as specified and directed. MAKES :- Cat part LSRTO1S0150XC of Jaquar, SLEUL150WIP-66(LXN) (SURYA), Cat pat LSTP-150-CDL/60-M of Crompton or equivalent in Philips/Wipro NOTE :- (i) MAKE of LED fixture/fitting and driver should be of same manufacture/company (ii) NABL certificate will be required at the time of sample approval. (iii) warrenty certificate shall be required for minimum 3 years. (iv) LM-80 and LM-79 test reports shall be produced with sample approval.
Taking down existing flood light fitting any type and S&F Integral LED flood light luminaire of 180 W with with high pressure die cast housing with lens, IP -65 rating with external SPD 10 KV and ported driver with all fixing arangement, nuts, bolts and washer connecting to electric system with 1.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion, complete all as specified and directed. MAKES :- Cat part LSRTO1S0180XC of Jaquar, SLEUL180WIP-66(LXN) (SURYA), Cat pat LSTP-180-CDL/60-M of Crompton or equivalent in Philips/Wipro NOTE :- (i) MAKE of LED fixture/fitting and driver should be of same manufacture/company (ii) NABL certificate will be required at the time of sample approval. (iii) warrenty certificate shall be required for minimum 3 years. (iv) LM-80 and LM-79 test reports shall be produced with sample approval.
Taking out old unserviceable garden/ post top light and Supply and fix 20/25 watt decorative LED post top Lantern luminaire IP -65 rated LED post top ideal to lit up parks garden ways and heritage sites complete fix on & including 50mm dia GI pipe, light grade with suitable screw/nut complete all as specified and directed. Makes : Jaquar/ Crompton/ Philips / Wipro/Surya
S&F in repairs Street light brackets made out of GI tubing, light grade, 32 mm bore 1200mm long, bent to shape at 120 degree, fixed on pole by providing MS clamp made up of flat iron 40 x 5 mm including bolts, nuts and washer of suitable size incuding painting the bracket & clamp with two coats of aluminium paint over a coat of primer complete all as specified and directed.
Supply and fix in repairs PVC insulated & PVC sheathed copper conductor cable 1.5 Sqmm multi-standard 1100 volt grade three core complete all specified and directed. Note : One run of three core cable shall be measured as one length.
Supply and fix in repairs PVC insulated & PVC sheathed copper conductor cable 2.5 Sqmm multi-standard 1100 volt grade three core complete all specified and directed. Note : One run of three core cable shall be measured as one length.
Supply and fix in repairs PVC insulated & PVC sheathed copper conductor cable 6 Sqmm multi-standard 1100 volt grade five core complete all specified and directed. Note : One run of five core cable shall be measured as one length.
M & L for cutting under the black top road/hard standing/floor of size 0.30 x 0.30 mtr by mechanical boring machine / manually suitable to fix the GI pipe 80 mm under the road & making good the surfaces to matgh with existing complete all as specified and directed.
Supply and laying for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note:-punned thickness shall only be measured & paid.
Supply and laying brick protection cover to LT underground cable with old size sub class 'B' bricks locally availabie dry laid flat across of the length of trench as in cable protection complete all as specified and directed.
S & F in repair GI pipe light grade for cable protection of size 80mm dia laid in trenches/ducts or fixed to pole/wall including necessary fixing arrangements with clamp of suitable sizes complete all as specified and directed.
S & F in repair GI pipe light grade for cable protection of size 50mm dia laid in trenches/ducts or fixed to pole/wall including necessary fixing arrangements with clamp of suitable sizes complete all as specified and directed.
S & F in repair GI pipe light grade for cable protection of size 40mm dia laid in trenches/ducts or fixed to pole/wall including necessary fixing arrangements with clamp of suitable sizes complete all as specified and directed.
Taking out old unserviceable UG/XLPE cable of size 10 sqmm, 4 core & Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium stranded conductor of size 10 sqmm, 4 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc complete all as specified and directed. ( Excavation and earth work shall be measured and paid for separately).
Taking out old unserviceable UG/XLPE cable of size 10 sqmm, 2 core & Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium stranded conductor of size 10 sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc complete all as specified and directed. ( Excavation and earth work shall be measured and paid for separately).
Taking out old unserviceable UG/XLPE cable of size 6 sqmm, 2 core & Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium stranded conductor of size 6 sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc complete all as specified and directed. ( Excavation and earth work shall be measured and paid for separately).
Taking down defective 70/150/250/400 watt SV/MH lamp type of street light fittings, any type and at any height, mounted on poles/bldgs with bracket, disconnecting, replacement of defective components such as choke, ignitors, holders, capacitors, etc and providing suitable new PVC cable for internal wiring, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components (measured and paid separately in respective item of BOQ) and then mounting to its original position and making the fitting functional including testing complete all as specified and directed. Note : (i) No T &P will be issued by the Department. (ii) Spares such as choke, ignitor, lamp holder, cable, lamps, etc shall be paid and measured separately. (iii) Rates also include repairing of defective street light timers, fault in street light feeders, etc (iv) During period of currency of CA any fitting will be not considered for more than once for payment purpose.
Taking down defective 150/180/250/400 watt high mast consisting of SV/MH/LED lamp type light fittings (Aprox 4 to 9 Nos in each fitting), any type, mounted on upto 9.7 to 10 mtr long high mast pole on brackets/round ring, disconnecting, replacement of defective components such as choke, ignitors, holders, capacitors, etc and providing suitable new PVC cable for internal wiring, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components measured and paid separately in respective item of BOQ and then mounting to its original position and making the fitting functional including testing complete all as specified and directed. Note : (i) No T &P will be arranged by contractot (ii) Spares such as choke, ignitor, lamp holder, cable, lamps, etc shall be paid and measured separately. (iii) Rates also include repairing of defective street light timers, fault in street light feeders, etc (iv) During period of currency of CA any fitting will be not considered for more than once for payment purpose.
Taking down defective 150/180/250/400 watt high mast consisting of SV/MH lamp type light fittings (Aprox 4 to 9 Nos in each fitting), any type, mounted on upto 16 mtr long high mast pole on brackets/round ring, disconnecting, replacement of defective components such as choke, ignitors, holders, capacitors, etc and providing suitable new PVC cable for internal wiring, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components measured and paid separately in respective item of BOQ and then mounting to its original position and making the fitting functional including testing complete all as specified and directed. Note : (i) No T &P will be arranged by contractot (ii) Spares such as choke, ignitor, lamp holder, cable, lamps, etc shall be paid and measured separately. (iii) Rates also include repairing of defective street light timers, fault in street light feeders, etc (iv) During period of currency of CA any fitting will be not considered for more than once for payment purpose.
Supply only LED driver suitable for 90 W LED of existing make as specified, 240 of volts. 50 Hz complete all as specified and directed. MAKE: Bajaj/Wipro/CG/Philips/Havells/Surya as approved by GE.
Supply only LED driver suitable for 70/72 W LED of existing make as specified, 240 volts. 50 Hz complete all as specified and directed. MAKE: Bajaj/Wipro/CG/Philips/Havells/Surya as approved by GE.
Supply only LED driver suitable for 60 W LED of existing make as specified, 240 volts. 50 Hz complete all as specified and directed. MAKE: Bajaj/Wipro/CG/Philips/Havells/Surya as approved by GE.
Supply only 400 watt HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin, terminal block with tapping for 220/240 volt, 50 Hz complete all as specified and directed. MAKE: Bajaj Cat Part No BJOS 400 SV / MH / C & S Cat part No LTAS 002 or equivalent in Bajaj/CG/Havells as approved by GE.
Supply only 70/150 /250 watt HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin, terminal block with tapping for 220/240 volt, 50 Hz complete all as specified and directed. MAKE: Bajaj Cat Part No BJOS 70/150/250 SV / MH or equivalent in /CG/Havells as approved by GE.
Supply only 400 watt MH lamp SE/DE tubular suitable for integral / non integral street/flood light luminairs complete all as specified and directed. MAKE:BAJAJ CAT PART No 140037 or equivalent in Surya/ Bajaj/CG/Havells as approved by GE.
Supply only 250 watt HPSV/MH lamp suitable for street/flood light luminairs complete all as specified and directed. MAKE: Bajaj or equivalent in Surya/CG/Havells as approved by GE.
Supply only 70 to150 watt HPSV/MH lamp SE/DE tubular suitable for integral / non integral street/flood light luminairs complete all as specified and directed. MAKE: BAJAJ or equivalent in Surya/CG/Havells as approved by GE.
Supply only electronic ignitors suitable for 150/250/400 watt SV/MH street light fitting 240V, 50HZ complete all as specified and directed. MAKE: Bajaj, or equivalent in Surya/CG/Philips/Havells as approved by GE.
Taking down old unserviceable thimble lugs & S&F aluminium thimble lugs of 10 to 25 sqmm sizes complete all as specified and directed.
S&F in repair MCB single pole, 240 Volt, 10 KA, 6 to 40 Amp conforming to IS 8828 of 1996, Curve 'C' complete all as specified & directed.
Rectyfing the LT cable fault, repair the cable properly and restore the electric supply in any bldg/location including minor excavation and earth work in cantt area complete all as specified and directed. Note : Excavation and earth work shall be measured and paid separetely.
M/s Pankaj Enterprises
POONAM ELECTRIC INDUSTRY
Nvimal Engineer and Contractor
kirtiman traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .