| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | ₹31.2 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹31.8 LRejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹31.8 L | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹97.2 LRejected-Finance | ₹97.2 L | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹39.4 LRejected-Finance | ₹39.4 L | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹42.0 LRejected-Finance | ₹42.0 L | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | ASIA ENTERPRISES L3 | KULBHUSHAN AGGARWAL L5 | M/S JIWAN SINGH L4 | M/S VIRENDER SADHOTRA L1 | bharat contrectors L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying, testing and commissioning HT XLPE cable, insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with multistaranded aluminium conductor, conforming to IS : 7098 (Part II), 11000 Volts "E" grade, cross sectional area 3 core x 120 sqmm (Earthed) laid in trenches/ ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. | 400 | Running Metre | 1,600 ₹6,40,000 | 1,225 ₹4,90,000 | 1,322 ₹5,28,800 | 1,500 ₹6,00,000 | 1,100 ₹4,40,000 Lowest |
| 2.00 | Supply, laying & testing of LT cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts, grade cross sectional area 185sqmm 3.5 core, complete all as specified and directed. | 100 | Running Metre | 1,900 ₹1,90,000 | 1,575 ₹1,57,500 | 1,952 ₹1,95,200 | 1,500 ₹1,50,000 Lowest | 1,500 ₹1,50,000 Lowest |
| 3.00 | S & F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.00 metres long) with necessary excavation, foundation and coping including applying two coats of of exterior weather proof paint of approved colour to pole and to MS cross arms, cable protection pipe, brackets etc with two coats of Aluminium Paint over a coat of red oxide primer including Synthetic enamel Painting in alternate lines of Yellow & Black Strips min of 6 Nos (each Strip 200 mm wide) at bottom of pole complete all as specified and directed. Note:- Earth work, Cement Concrete etc. will be measured and paid under approprite Items. | 6 | Each | 32,000 ₹1,92,000 | 23,500 ₹1,41,000 | 26,500 ₹1,59,000 | 26,000 ₹1,56,000 | 20,000 ₹1,20,000 Lowest |
| 4.00 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed | 4.8 | Quintal | 12,000 ₹57,600 | 9,900 ₹47,520 | 5,500 ₹26,400 Lowest | 14,000 ₹67,200 | 10,000 ₹48,000 |
| 5.00 | M & L of lightening arresters nominal discharge current Peak 65 KA rating, suitable for operation on HT 11000 volts system, comprising of zinc oxide disks, electrodes, fibre re-in forced composite structure, non tracking weather resistant shedded heat shrinked polymeric housing for withstanding from the effects of pollution, rain, heat and with moisture seal , stainless steel bolts and nuts, stainless steel end fitting cups and fixing arrangements complete all as specified and directed. | 3 | Set of three | 5,000 ₹15,000 | 5,000 ₹15,000 | 2,500 ₹7,500 Lowest | 12,000 ₹36,000 | 5,000 ₹15,000 |
| 6.00 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. (iii) The required resistance of Earthing shall be 2 ohm or less than 2 ohm, If not found to the required resisstance, the contractor has to reorganised for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance. | 24 | Each Set | 4,000 ₹96,000 | 4,500 ₹1,08,000 | 2,800 ₹67,200 Lowest | 6,500 ₹1,56,000 | 4,500 ₹1,08,000 |
| 7.00 | Supply, installation, connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating upto 400 amps and working voltage 11000 volts all as required at site complete all as specified and directed. | 2 | Each | 22,000 ₹44,000 | 18,000 ₹36,000 | 14,500 ₹29,000 | 7,200 ₹14,400 Lowest | 12,000 ₹24,000 |
| 8.00 | Supply anf fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqm complete all as specified and directed. | 4 | Each | 3,000 ₹12,000 | 3,500 ₹14,000 | 2,500 ₹10,000 Lowest | 6,300 ₹25,200 | 10,000 ₹40,000 |
| 9.00 | Supply and installation, commissioning and testing CPRI approved OEM made main LT Panel. The panel shall be made of modula CRCA ENCLOSURES including MCCBs and Indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy ofCPRI TEST REPORT only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of CRCA accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current-Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for CRCA Board only. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self extinguishing) comprising the following accessories:-
INCOMER: (a).Main MCCB 400 amp 4Pole Breaking Capacity 36KA Thermal and Magnetic Released with Spreader Links & Extended Rotary Handle-1 No.
(b) Digital VAF meter Voltmeter (0-500 volt) ammeter (0-500 amp) frequency -01 no 3. LED Indicator Lamp R,Y,B-3 Nos 4. Control Fuse-3 No 5. CT coils 250/5A-3 Nos
OUTGOING: (a) MCCB 160 Amp 4Pole Breaking Capacity 25 KA Thermal and Magnetic Released with Spreader Links & Rotary Handle-2 Nos. Make-Legrand/ABB/Schnleder/L&T.
(b) MCCB 100 Amp 4Pole Breaking Capacity 25 KA Thermal and Magnetic Released with Spreader Links & Rotary Handle-3 Nos.
Note: Fixing, Labour charges, including Cable Glands, Lugs, connected items such as Nuts, Bolts, Washers etc., earth work and PCC work charges are deemed to be included in quoted rates. | 1 | Each | 1,00,000 ₹1,00,000 Lowest | 3,10,000 ₹3,10,000 | 2,25,000 ₹2,25,000 | 1,25,000 ₹1,25,000 | 2,50,000 ₹2,50,000 |
| 10.00 | Construction of transformer platform size 3mx2mx1m from ground incl XPM jalli fabricated with angle size 50x50x6mm and two coat of aluminum paint over one coat of red oxide inci steps plinth protection and all other relevant works complete all as specified and directed. | 2 | Each Job | 70,000 ₹1,40,000 | 30,000 ₹60,000 | 40,000 ₹80,000 | 65,000 ₹1,30,000 | 25,000 ₹50,000 Lowest |
Tender Value
₹39.0 L
EMD Value
₹78,100
Closing Date
7 Mar 2026, 6:00 pmClosed
Anurag Anand DCWE
HQ 135 WKS ENGRS PIN- 914135 C/O 56 APO
UNDER GE (N) AKHNOOR (Only external electric supply) AND PROVN OF BOREWELL AND CONNECTED CONNECTED ITEMS FOR AUGMENTATION OF WATER SUPPLY under GE (N) AKHNOOR (Only external electric supply)
2026_MES_751804_1
CWE/JA-42/2025-26
Open Tender
Electrical and Maintenance Works
Works
180 days
AKHNOOR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH AKHNOOR
₹78,100
Yes
11 May 2026
7 Feb 2026
9 Mar 2026
7 Feb 2026
7 Mar 2026
28 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, laying, testing and commissioning HT XLPE cable, insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with multistaranded aluminium conductor, conforming to IS : 7098 (Part II), 11000 Volts "E" grade, cross sectional area 3 core x 120 sqmm (Earthed) laid in trenches/ ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. | 400 | Running Metre | - | - |
| 2 | Supply, laying, testing and commissioning HT XLPE cable, insulated, screended, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with multistaranded aluminium conductor, conforming to IS : 7098 (Part II), 11000 Volts "E" grade, cross sectional area 3 core x 185 sqmm (Earthed) laid in trenches/ ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed. | 100 | Running Metre | - | - |
| 3 | S & F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.00 metres long) with necessary excavation, foundation and coping including applying two coats of of exterior weather proof paint of approved colour to pole and to MS cross arms, cable protection pipe, brackets etc with two coats of Aluminium Paint over a coat of red oxide primer including Synthetic enamel Painting in alternate lines of Yellow & Black Strips min of 6 Nos (each Strip 200 mm wide) at bottom of pole complete all as specified and directed. Note:- Earth work, Cement Concrete etc. will be measured and paid under approprite Items. | 6 | Each | - | - |
| 4 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed | 4.8 | Quintal | - | - |
| 5 | M & L of lightening arresters nominal discharge current Peak 65 KA rating, suitable for operation on HT 11000 volts system, comprising of zinc oxide disks, electrodes, fibre re-in forced composite structure, non tracking weather resistant shedded heat shrinked polymeric housing for withstanding from the effects of pollution, rain, heat and with moisture seal , stainless steel bolts and nuts, stainless steel end fitting cups and fixing arrangements complete all as specified and directed. | 3 | Set of three | - | - |
| 6 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. (iii) The required resistance of Earthing shall be 2 ohm or less than 2 ohm, If not found to the required resisstance, the contractor has to reorganised for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance. | 24 | Each Set | - | - |
| 7 | Supply, installation, connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating upto 400 amps and working voltage 11000 volts all as required at site complete all as specified and directed. | 2 | Each | - | - |
| 8 | Supply anf fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqm complete all as specified and directed. | 4 | Each | - | - |
| 9 | Supply and installation, commissioning and testing CPRI approved OEM made main LT Panel. The panel shall be made of modula CRCA ENCLOSURES including MCCBs and Indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy ofCPRI TEST REPORT only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of CRCA accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current-Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for CRCA Board only. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self extinguishing) comprising the following accessories:-
INCOMER: (a).Main MCCB 400 amp 4Pole Breaking Capacity 36KA Thermal and Magnetic Released with Spreader Links & Extended Rotary Handle-1 No.
(b) Digital VAF meter Voltmeter (0-500 volt) ammeter (0-500 amp) frequency -01 no 3. LED Indicator Lamp R,Y,B-3 Nos 4. Control Fuse-3 No 5. CT coils 250/5A-3 Nos
OUTGOING: (a) MCCB 160 Amp 4Pole Breaking Capacity 25 KA Thermal and Magnetic Released with Spreader Links & Rotary Handle-2 Nos. Make-Legrand/ABB/Schnleder/L&T.
(b) MCCB 100 Amp 4Pole Breaking Capacity 25 KA Thermal and Magnetic Released with Spreader Links & Rotary Handle-3 Nos.
Note: Fixing, Labour charges, including Cable Glands, Lugs, connected items such as Nuts, Bolts, Washers etc., earth work and PCC work charges are deemed to be included in quoted rates. | 1 | Each | - | - |
| 10 | Construction of transformer platform size 3mx2mx1m from ground incl XPM jalli fabricated with angle size 50x50x6mm and two coat of aluminum paint over one coat of red oxide inci steps plinth protection and all other relevant works complete all as specified and directed. | 2 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_842055.xls
BOQ • 1.82 MB
TENDER42.pdf
Tender Documents • 1.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].