Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹96.0 CrQualified | ₹96.0 Cr | Qualified |
| 2 | Qualified | - | Qualified |
Tender Value
Refer Docs
Closing Date
9 Feb 2026, 11:00 amClosed
Vikash Chandra
Power Grid Corporation of India Ltd, Saudamini ,3rd Floor ,Plot No 2 ,Sector 29 Gurgaon,haryana,122001
400kV GIS substation package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
CC/NT/W-GIS/DOM/A04/25/12409
Open
Power/Energy Projects/Products
Works
ODISHA, ASSAM, SIKKIM
₹25,000
30 Apr 2026
18 Sept 2025
9 Feb 2026
18 Sept 2025
9 Feb 2026
18 Sept 2025
29 Sept 2025
Attachment-3 (QR)
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
SPECIFICATION No. : CC/NT/W-GIS/DOM/A04/24/10629
(Qualifying Requirement Data)
Bidders’s Name & Address: Contract Services
Name: Power Grid Corporation of India Ltd.,
Address: "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Bidder/Lead Partner In case of Joint Venture
For Other Partner(s) For Other Partner(s)
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
1.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
TECHNICAL EXPERIENCE
1.1 Route-1: The Bidder must have designed, manufactured, type tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least two (2) nos. Gas Insulated Switchgear (GIS) circuit breaker bays@ of 345kVor above voltage class in one (1) Substation or Switchyard during the last seven (7) years and these bays must be in satisfactory operation# for at least two (2) years as on the on the Originally scheduled last date of bid submission (soft copy) i.e. 16/10/2025.
2.1.1 In case the Bidder is a Foreign Entity, following requirements shall be complied:
i (i) If the bidder is submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, the bidder must, in its bid, propose an Indian Associate for executing the On-Shore Supply and On-Shore Services Contract, as per the provisions of bidding documents. The proposed Indian Associate must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays of 110KV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above For executing on-shore supply contract, the bidder in its bid, may alternatively propose its Indian Subsidiary or Group or Joint Venture Company as Indian Associate provided that the proposed Indian Associate has been registered in India (as per Companies Act 1956 or 2013 of India) for establishing manufacturing and testing facilities for 765kV GIS or above voltage level as on the date of bid opening mentioned above.
ii A) The Subsidiary or Group Company or a Joint Venture Company (JVC) of the bidder shall have manufacturing & testing facilities for 765kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned above. OR The bidder must have incorporated a Subsidiary or Group Company or a Joint Venture Company (JVC) as per Companies Act 1956 or 2013 of India, to manufacture 765kV or above voltage level GIS in India and it must have commenced the construction activities for establishment of 765kV or above voltage level GIS manufacturing and testing facilities in India as on the originally scheduled date of bid opening mentioned above. B) The bidder must supply at least one (1) no. 765kV GIS Circuit breaker bay* manufactured in the said facilities in India, for which Bidder shall furnish an undertaking (as per enclosed format in Volume-III of Bidding Document) along with the bid. C) Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from Indian works of its Subsidiary or Group Company or a Joint Venture Company (JVC) provided the Subsidiary/JVC/Group Company must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay should have been either supplied or type tested (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above.
1.2 Route-2: 1.2 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that- a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the collaborator(s), provided that the collaborator(s) meets the requirement stipulated in para 1.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled last date of bid submission mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the Collaborator(s) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 10 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
1.3 Route-3: 1.3 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS as Subsidiary/JVC/Group company by its parent/principal but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that- a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the parent/principal, provided that the parent/principal meets the requirement stipulated in para 1.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled last date of bid submission mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the parent/principal company) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
1.4 Route-4 1.4 In case, the bidder is not a GIS manufacturer, he shall also be considered provided: i. The bidder must have erected and commissioned at least two (02) nos. GIS circuit breaker bays of 345kV or above voltage class in one (01) new GIS substation or switchyard during last seven (07) years and these bays must be in satisfactory operation# for at least two (02) years as on the originally scheduled last date of bid submission mentioned above. ii. The GIS must be offered from Indian manufacturer, who meets the requirement mentioned at Route-1 or Route-2 or Route-3 above.QR Credential of proposed GIS Manufacturer(s) must be submitted along with the bid. iii.Bidder must submit a Manufacturer Authorization Form (MAF) from offered GIS manufacturer(s) (as per enclosed format in bidding document ) along with the Bid confirming that a legally enforceable Joint deed of Undertaking as per format enclosed at…of Bidding document shall be submitted at the time of signing of contract.
Note :- 1. (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark. 2. (@) For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. In case bidder is a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that subsidiary company only (i.e. excluding its holding company). 4. In case bidder is qualifying through Route-1, type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents. 5. In case of package comprises of multiple voltage level in one GIS substation and/or Extension of more then one GIS Substation(s), GIS from different manufacturer(s) shall also be acceptable subject to the condition that one voltage class of GIS at any substation is supplied from one manufacturer only. In such cases bidder must submit MAF from all the proposed GIS Manufacturer(s) in their bid.
Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder or of each Partner of a Joint Venture.
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder/Collaborator/ Parent/Principal/Partner of JV in case of Joint Venture/Indian GIS Mnaufacturer in support of meeting the requirement of para 1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of Bidder/Collaborator/ Parent/Principal/Partner of a JV/Indian GIS Manufacturer #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract
(Indicate nos. of GIS Circuit Breaker equipped bays of 345KV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above Substation have been in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
NOTE: type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents (Attachment-24 in Volume-III)
of Gas Insulated Switchgear (GIS) circuit breaker bays. of Gas Insulated Switchgear (GIS) circuit breaker bays.
In case of foreign entity, whether bidder have established/ commence the establishment of facility as Indian Subsidiary/ Group Company/ Joint Venture Company for manufacturing & testing of 765kV or above voltage level GIS in India (as per Companies Act 1956 or 2013 of India)
Whether bidder want to propose its above subsidiary/ Group Company/ Joint Venture Company as its associate for executing On-Shore Supply Contract
Foreign Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from India provided his Subsidiary or Group Company or a Joint Venture Company (JVC) must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay either should have been supplied or should have been type tested ( as per IEC or equivalent standard) as on the originally scheduled date of bid opening as mentioned above
Whether Undertaking (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
Format for the Indian Associate executing the On-Shore Supply and On-Shore Services Contract for a Foreign Entity submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, in support of meeting the requirement of para 1.1.1(i) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian Associate executing the On-Shore Supply and On-Shore Services Contract
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 No. of GIS/AIS Circuit Breaker equipped bays under the contract
(Indicate nos. of Circuit Breaker equipped bays of 220 kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
No. of years, the above CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format-B (Route-2):
Format in support of meeting the requirement of para 1.2 Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
1 Name of the Collaborator
2 Whether bidder have established manufacturing and testing facilities in India for 345KV or above voltage level Gas Insulated Switchgear (GIS)
3 Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder based on technological support of the collaborator have been supplied or Type tested
A if Type tested details of Type test Report
B Details of GIS supplied by them
i Name of Contract Undertaken for manufacturing 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
iv No. of 345KV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the substation or switchyard
Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Collaborator under the Contract.
Scope of work involved under the Contract
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit Breaker bays of 110KV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Collaborator(s) meets the technical experience criteria stipulated at 1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Collaborator(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Confirmation letter from the Collaborator(s) along with the bid stating that Collaborator(s) shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder/Manufacturer wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 715KV or above voltage level GIS equipment in India furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Details of documents uploaded in support of the above stated experience
Format-C: (Route-3)
Format in support of meeting the requirement of para 1.3 Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
1 Name of the Bidder established as Subsidiary/JVC/Group company by its parent/principal Company
2 Name of the parent/principal Company
3 Whether bidder have established manufacturing and testing facilities in India for 345KV or above voltage level Gas Insulated Switchgear (GIS)
4 Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder have been supplied or Type tested based on Technological support of their Parent/ Principal Company
A if Type tested details of Type test Report
B Details of Gas Insulated Switchgear (GIS) Circuit Breaker Bays supplied by them
i Name of Contract Undertaken for manufacturing 715KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
iv No. of 345KV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the substation or switchyard
Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/Principal Company under the Contract.
Scope of work involved under the Contract
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit Breaker bays of 110KV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Parent/Principal Company meets the technical experience criteria stipulated at 1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Parent/Principal Company (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Confirmation letter from the parent/principal company along with the bid stating that parent/principal company shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder/Manufacturer wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 715KV or above voltage level GIS equipment in India furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Name of the substation or switchyard
Whether 110KV or above voltage level Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/ Principal Company under the Contract.
If Yes, indicate the Name of Parent/ Principal Company(s)
No. of years, the above AIS/GIS Subatation(s) are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract for the above 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS bay as per IEC as on the originally scheduled date of bid opening
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.3 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Parent Company/ Principal (refer para 1.3), if applicable: #REF!
Name of the 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.3), if applicable : 0 #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Circuit Breaker bays of 110KV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Joint Deed of Undertaking executed between The Bidder and 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufaturer has been enclosed with bid ? (in line with para 1.3 (b)(i) of Annexure-A (BDS)
Whether confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s) has been enclosed with bid? (in line with para 1.3(b)(ii) of Annexure-A (BDS)
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS equipment in India has been enclosed with bid ? (in line with para 1.3(b)(iii) of Annexure-A (BDS)
Details of documents uploaded in support of the above stated experience
Format-D: (Route-4)
Format in support of meeting the requirement of para 1.4(Route-4) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name :
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the New substation or switchyard
Scope of work involved under the Contract (Tick whichever is/are applicable)
No. of years, the above GIS Circuit Breaker equipped bays have been in operation as on the originally scheduled date of bid opening.
Details of documents uploaded in support of the above stated experience
Name of the Proposed Indian GIS Manufacturer (as per the Route-4 of Annexure-A(BDS)
Whether above Indian GIS Manufacturer meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. (If Yes, Please mentioned the details in the Format-A/Format-B/Format-C above)
Whether Manufacturer Authorization Form (MAF) from offered GIS manufacturer(s) (as per enclosed format in bidding document) (confirming that a legally enforceable Joint deed of Undertaking (as per enclosed format at Form 22 in Section VI, Vol-I of bidding document) shall be submitted at the time of signing of contract) is enclosed with the bid
Details of documents uploaded in support of the above stated experience
2.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 2.0 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive
b) Minimum Average Annual Turnover^(MAAT) of the bidder for best three years i.e. 36 months out of last five financial years of the bidder should be not less than [Rs. 65.70 Crore or equivalent for 400kV GIS substation package SS-135 (Re-tender)]
^Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other operative income / other income”.
For Bidders to qualify for more than one package, their financial position shall not be less than the sum of the requirement for the packages they propose to qualify for ( strike through if only one package)
c) Liquid Assets (LA) and/or evidence of access to or availability of credit facilities should be not less than [Rs. 10.95 Crore or equivalent for 400kV GIS substation package SS-135 (Re-tender)].
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) as on the originally scheduled last date of bid submission as above, the financial position requirement as per para 2.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he completes five (5) years from the date of commercial production of such equipment (s) in India as on the originally scheduled last date of bid submission as above, the financial position requirements as specified at 2.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 2.0 (a) above of parent/principal shall be considered. (iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/ MSEs, meeting the specified requirements at Para 2.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 2.0 (b) & 2.0 (c) above in Financial Position. ^ Start-Ups as defined by DPIIT, applicable as on the Originally scheduled last date of bid submission (soft copy).
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or each of the Partners of a Joint Venture (in case of bidding by a Joint Venture) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
2.1 Financial Qualification Data: 2 or more
Name of the Bidder
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2024-25 Yes
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2024-25 Yes
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-1 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2024-25 Yes
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
C Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-2 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2024-25 Yes
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2020-21
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
3.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
JOINT VENTURE BIDS: a) In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively the complete requirements stipulated at para 1.0 and 2.0 (b) & (c) above. Further, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 2.0(a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum Financial Position criteria given at para 2.0 (b) & (c) iii. Each of the other partner(s) individually shall meet not less than 25% of the minimum Financial Position criteria given at para 2.0 (b) & (c) above The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 2.0 (b) & (c) above. b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above ii. The remaining partner(s) must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays* of 345kVor above voltage level in one (1) substation or switchyard during the last seven (7) years in India and these bays@ must be in satisfactory operation# as on the originally scheduled last date of bid submission mentioned above. Note :- (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above ii. The remaining partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above or must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays* of 345kV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above.
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
Note :- 1. (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark 2. (*) For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. ($) In case of a JV bid involving an Indian Entity qualifying through Route-3 and its parent/ principal company as partner(s), the Indian Entity shall meet the applicable Financial Position criteria on its own and not based on its parent/principal company.
4 The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
B For Name of Other Partner-1 of JV
C For Name of Other Partner-2 of JV
Format in support of meeting the requirement of para 3.0(b)(ii) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Partner of JV
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of AIS/GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
No. of AIS/GIS Circuit Breaker equipped bays under the above contract (Indicate nos. of AIS/Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs.)
Name of the substation or switchyard
Scope of work involved under the Contract (Tick whichever is/are applicable)
No. of years, the above AIS/GIS Circuit Breaker equipped bays have been in operation as on the originally scheduled date of bid opening.
Details of documents uploaded in support of the above stated experience
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
Audited balance sheet and income statements for the last five years as per the following:
For Name of Other Partner-1 of JV For Name of Other Partner-2 of JV
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed
1st Year Yes Yes
2nd Year Yes Yes
3rd Year Yes Yes
4th Year Yes Yes
5th Year Yes Yes
6 In addition to the data/details furnished as above, the information available at ‘Information on Record’ (IoR) portal of POWERGRID may also be considered as our submission for purpose of QR compliance.
Date : Printed Name :
Place : Designation :
ATTACHMENTS General guidelines for filling up the Attachments 400kV GIS Substation Package SS-151 Rev1
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409]
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(QR), 4, 4(A), 5, 5(A), 6, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18 & 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : Not Applicable
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 (a) Manufacturer’s Authorisation Form and 8(b) Manufacturer’s Authorization Form (applicable for GIS Manufacturer(s) proposed by bidder qualifying through Route-4 of Qualifying Requirements) : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. This attachment is not included here.
6 Attachment 10 Guarantee Declaration: We hereby declare that Attachment-10 (Guarantee Declaration) is provided in our Second Envelope Bid.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
7 Attachment 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31 & 32: To be submitted as per the provisions of the Bidding Documents (Formats Attached seperately in Volume-III if Bidding Documents.
8 Attachment 24: Confirmation in regard to Design and Type Test (to be furnished in case bidder is proposing to qualify through Note-4 under Route-1 of QR)
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] Individual Firm (Route-1)
Individual Firm (Route-2)
Enter the details of the bidder below: Individual Firm (Route-3)
Individual Firm (Route-4)
Specify type of Bidder [Select from drop down menu] Joint Venture Bid
{as per sl. no. 1.1 OR 1.2 OR 1.3 OR 1.4 (as applicable) of Annexure-A (BDS) of Vol-I (Conditions of Contract)} 1
Whether the bidder is an MSE (Micro & Small Enterprise) Yes
Enter the Name of Registration Authority
Name of the Bidder 1
Address of Registered Office 2 or more
Address of Registered Office
Pick date from here (mm/dd/yyyy):
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-3 (JV) #REF! #REF!
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address : To:
0 Contract Services 1 #REF!
Name : 0 Power Grid Corporation of India Ltd., 2 or more
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
* applicable for Joint Venture
Date : 00-Jan-00 Printed Name : 0 #REF!
Place : 0 Designation : 0 #REF!
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-3 (QR)
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Qualifying Requirement Data)
Bidder’s Name and Address : To:
0 Contract Services
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
For our Qualification Requirement data, please refer Attachment-QR annexed herewith
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
We have submitted bid as individual firm.
We have submitted bid as joint venture of following firms :
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
C Whether bidder anticipate any change in legal structure/ ownership of their organisation at present. If Yes, please enclose details of same and copy of procedural document(s) with reference to the same/ as required statutorily, as of now
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Sole Bidder
1 Name of the Firm 0 0 0
2 Head Office/ Registered Office Address 0 0 0
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
2.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
TECHNICAL EXPERIENCE
2.1 The Bidder must have designed, manufactured, type tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least two (2) nos. Gas Insulated Switchgear (GIS) circuit breaker bays@ of 345kVor above voltage class in one (1) Substation or Switchyard during the last seven (7) years and these bays must be in satisfactory operation# for at least two (2) years as on the originally scheduled date of bid opening i.e. 15/02/2022
2.2 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that- a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the collaborator(s), provided that the collaborator(s) meets the requirement stipulated in para 1.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the Collaborator(s) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 3 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
2.3 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS as Subsidiary/JVC/Group company by its parent/principal but not meeting the requirement stipulated in para 2.1 above, shall also be considered provided that- a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the parent/principal, provided that the parent/principal meets the requirement stipulated in para 2.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the parent/principal company) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 3 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
2.4 In case, the bidder is not a GIS manufacturer, he shall also be considered provided: i. The bidder must have erected and commissioned at least two (02) nos. GIS circuit breaker bays of 345kV or above voltage class in one (01) new GIS substation or switchyard during last seven (07) years and these bays must be in satisfactory operation# for at least two (02) years as on the originally scheduled date of bid opening mentioned above. ii. The GIS must be offered from Indian manufacturer, who meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. iii. A legally enforceable undertaking (jointly with the GIS Manufacturer) (as per enclosed format in Section-VI, Volume-I of bidding document) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s) is submitted along with the bid stating that GIS Manufacturer shall furnish performance guarantee for an amount of two (2) % of the total contract price. This performance guarantee shall be in addition to the Contract Performance security to be submitted by the Bidder.
Note :- 1. (#)Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark. 2. (@) For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. In case bidder is a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that subsidiary company only (i.e. excluding its holding company). 4. In case bidder is qualifying through Route-1, type test reports of Collaborator/ Parent Company/Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents.
2.5 Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder or of each Partner of a Joint Venture.
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder/Collaborator/ Parent/Principal/Partner of JV in case of Joint Venture/Indian GIS Mnaufacturer in support of meeting the requirement of para 1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of Bidder/Collaborator/ Parent/Principal/Partner of a JV/Indian GIS Manufacturer #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 345kV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract
(Indicate nos. of GIS Circuit Breaker equipped bays of 345kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs.)
Name of the substation or switchyard
Date of Commissioning
(a)(ii) No. of years, the above Substation have been in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
NOTE: type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents (Attachment-29 in Volume-III)
of Gas Insulated Switchgear (GIS) circuit breaker bays. of Gas Insulated Switchgear (GIS) circuit breaker bays.
In case of foreign entity, whether bidder have established/ commence the establishment of facility as Indian Subsidiary/ Group Company/ Joint Venture Company for manufacturing & testing of 765kV or above voltage level GIS in India (as per Companies Act 1956 or 2013 of India)
Whether bidder want to propose its above subsidiary/ Group Company/ Joint Venture Company as its associate for executing On-Shore Supply Contract
Foreign Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from India provided his Subsidiary or Group Company or a Joint Venture Company (JVC) must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay either should have been supplied or should have been type tested ( as per IEC or equivalent standard) as on the originally scheduled date of bid opening as mentioned above
Whether Undertaking (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
Format for the Indian Associate executing the On-Shore Supply and On-Shore Services Contract for a Foreign Entity submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, in support of meeting the requirement of para 1.1.1(i) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian Associate executing the On-Shore Supply and On-Shore Services Contract
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 No. of GIS/AIS Circuit Breaker equipped bays under the contract
(Indicate nos. of Circuit Breaker equipped bays of 345 kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
No. of years, the above CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format-B (Route-2):
Format in support of meeting the requirement of para 1.2 Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
1 Name of the Collaborator
2 Whether bidder have established manufacturing and testing facilities in India for 345kV or above voltage level Gas Insulated Switchgear (GIS)
3 Whether 345kV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder based on technological support of the collaborator have been supplied or Type tested
A if Type tested details of Type test Report
B Details of GIS supplied by them
i Name of Contract Undertaken for manufacturing 345kV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
iv No. of 345kV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345kV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the substation or switchyard
Whether 345kV or above voltage level Gas Insulated Switchgear (GIS) Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Collaborator under the Contract.
Date of Type Testing
Scope of work involved under the Contract
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 345kV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit Breaker bays of 345kV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Collaborator(s) meets the technical experience criteria stipulated at 2.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Collaborator(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Confirmation letter from the Collaborator(s) along with the bid stating that Collaborator(s) shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 3% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder/Manufacturer wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Details of documents uploaded in support of the above stated experience
Format-C: (Route-3)
Format in support of meeting the requirement of para 1.3 Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
1 Name of the Bidder established as Subsidiary/JVC/Group company by its parent/principal Company
2 Name of the parent/principal Company
3 Whether bidder have established manufacturing and testing facilities in India for 345kV or above voltage level Gas Insulated Switchgear (GIS)
4 Whether 345kV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder have been supplied or Type tested based on Technological support of their Parent/ Principal Company
A if Type tested details of Type test Report
B Details of Gas Insulated Switchgear (GIS) Circuit Breaker Bays supplied by them
i Name of Contract Undertaken for manufacturing 345kV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
iv No. of 345kV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345kV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the substation or switchyard
Whether 345kV or above voltage level Gas Insulated Switchgear (GIS) Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/Principal Company under the Contract.
Date of Type Testing
Scope of work involved under the Contract
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 345kV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit Breaker bays of 345kV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Parent/Principal Company meets the technical experience criteria stipulated at 2.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Parent/Principal Company (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Confirmation letter from the parent/principal company along with the bid stating that parent/principal company shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 3% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder/Manufacturer wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Name of the substation or switchyard
Whether 345kV or above voltage level Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/ Principal Company under the Contract.
If Yes, indicate the Name of Parent/ Principal Company(s)
No. of years, the above AIS/GIS Subatation(s) are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract for the above 345kV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS bay as per IEC as on the originally scheduled date of bid opening
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.3 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Parent Company/ Principal (refer para 1.3), if applicable: #REF!
Name of the 345kV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.3), if applicable : 0 #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Circuit Breaker bays of 345kV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Joint Deed of Undertaking executed between The Bidder and 345kV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufaturer has been enclosed with bid ? (in line with para 1.3 (b)(i) of Annexure-A (BDS)
Whether confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s) has been enclosed with bid? (in line with para 1.3(b)(ii) of Annexure-A (BDS)
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS equipment in India has been enclosed with bid ? (in line with para 1.3(b)(iii) of Annexure-A (BDS)
Details of documents uploaded in support of the above stated experience
Format-D: (Route-4)
Format in support of meeting the requirement of para 1.4(Route-4) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name :
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of new GIS Substation or switchyard commissioned under the Contract (Indicate 345kV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345kV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the New substation or switchyard
Scope of work involved under the Contract (Tick whichever is/are applicable)
No. of years, the above GIS Circuit Breaker equipped bays have been in operation as on the originally scheduled date of bid opening.
Details of documents uploaded in support of the above stated experience
Name of the Proposed Indian GIS Manufacturer (as per the Route-4 of Annexure-A(BDS)
Whether above Indian GIS Manufacturer meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. (If Yes, Please mentioned the details in the Format-A/Format-B/Format-C above)
Whether Undertaking (Jointly with the GIS Manufacturer) (as per enclosed format in Section-VI, Vol-I of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
3.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 2.0 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive.
b) Minimum Average Annual Turnover^(MAAT) of the bidder for best three years i.e. 36 months out of last five financial years of the bidder should be Rs. 1563.43 million or equivalent for SS 90 Package
^Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other operative income / other income”.
For Bidders to qualify for more than one package, their financial position shall not be less than the sum of the requirement for the packages they propose to qualify for ( strike through if only one package)
c) Bidder shall have Liquid Assets (LA) and/or evidence of access to or availability of credit facilities of not less than Rs. 260.57 million or equivalent for SS-90 Package
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 3.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 3.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) as on the originally scheduled date of bid opening as above, the financial position requirement as per para 3.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he completes five (5) years from the date of commercial production of such equipment (s) in India as on the originally scheduled date of bid opening as above, the financial position requirements as specified at 3.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 3.0 (a) above of parent/principal shall be considered (iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/ MSEs, meeting the specified requirements at Para 3.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 3.0 (b) & 3.0 (c) above in Financial Position.
^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or each of the Partners of a Joint Venture (in case of bidding by a Joint Venture) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
2.1 Financial Qualification Data: 0
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2020-21 No
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
3.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
JOINT VENTURE BIDS: a) In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively the complete requirements stipulated at para 2.0 and 3.0 (b) & (c) above. Further, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 3.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum Financial Position criteria given at para 3.0 (b) & (c) iii. Each of the other partner(s) individually shall meet not less than 25% of the minimum Financial Position criteria given at para 3.0 (b) & (c) above The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 3.0 (b) & (c) above. b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 2.0 above ii. The remaining partner(s) of JV must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays@ of 345KV or above voltage level in one (1) substation or switchyard during the last seven (7) years in India and these bays@ must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above. Note :- (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
4 The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
Format in support of meeting the requirement of para 3.0(b)(ii) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Partner of JV
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of AIS/GIS Substation commissioned under the Contract (Indicate 345kV or above class only)
No. of AIS/GIS Circuit Breaker equipped bays under the above contract (Indicate nos. of AIS/Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345kV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs.)
Name of the substation or switchyard
Scope of work involved under the Contract (Tick whichever is/are applicable)
No. of years, the above AIS/GIS Circuit Breaker equipped bays have been in operation as on the originally scheduled date of bid opening.
Details of documents uploaded in support of the above stated experience
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
Audited balance sheet and income statements for the last five years as per the following:
Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
Attachment-3 (QR)
Substation Package SS-144 for (i)Augmentation of transformation capacity at 400/220kV Bidadi (GIS) S/s in Karnataka by 1x500 MVA, 400/220kV ICT (3rd), (ii)Augmentation of Transformation capacity at 400/220kV Yelahanka (GIS) S/s (POWERGRID) in Karnataka by 400/220kV, 1X500MVA ICT (3rd); [Specification No.: CC/NT/W-GIS/DOM/A10/24/15640]
(Qualifying Requirement Data)
Bidders’s Name & Address: Contract Services
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Bidder/Lead Partner In case of Joint Venture
For Other Partner(s) For Other Partner(s)
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
1.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
TECHNICAL EXPERIENCE
1.1 Route-1: 1.1 The Bidder must have designed, manufactured, type tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least two (2) nos. Gas Insulated Switchgear (GIS) circuit breaker bays@ of 345kV or above voltage class in one (1) Substation or Switchyard during the last seven (7) years and these bays must be in satisfactory operation# for at least two (2) years as on the Originally scheduled last date of bid submission (soft copy)i.e. 04.02.2025
2.1.1 In case the Bidder is a Foreign Entity, following requirements shall be complied:
i (i) If the bidder is submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, the bidder must, in its bid, propose an Indian Associate for executing the On-Shore Supply and On-Shore Services Contract, as per the provisions of bidding documents. The proposed Indian Associate must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays of 110KV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above For executing on-shore supply contract, the bidder in its bid, may alternatively propose its Indian Subsidiary or Group or Joint Venture Company as Indian Associate provided that the proposed Indian Associate has been registered in India (as per Companies Act 1956 or 2013 of India) for establishing manufacturing and testing facilities for 765kV GIS or above voltage level as on the date of bid opening mentioned above.
ii A) The Subsidiary or Group Company or a Joint Venture Company (JVC) of the bidder shall have manufacturing & testing facilities for 765kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned above. OR The bidder must have incorporated a Subsidiary or Group Company or a Joint Venture Company (JVC) as per Companies Act 1956 or 2013 of India, to manufacture 765kV or above voltage level GIS in India and it must have commenced the construction activities for establishment of 765kV or above voltage level GIS manufacturing and testing facilities in India as on the originally scheduled date of bid opening mentioned above. B) The bidder must supply at least one (1) no. 765kV GIS Circuit breaker bay* manufactured in the said facilities in India, for which Bidder shall furnish an undertaking (as per enclosed format in Volume-III of Bidding Document) along with the bid. C) Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from Indian works of its Subsidiary or Group Company or a Joint Venture Company (JVC) provided the Subsidiary/JVC/Group Company must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay should have been either supplied or type tested (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above.
1.2 Route-2: 1.2 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS but not meeting the requirement stipulated in Para 1.1 above, shall also be considered provided that- a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the collaborator(s), provided that the collaborator(s) meets the requirement stipulated in para 1.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled last date of bid submission mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the Collaborator(s) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 10 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
1.3 Route-3: 1.3 The Bidder, who has established manufacturing & testing facility in India for 345kV or above voltage level GIS as Subsidiary/JVC/Group company by its parent/principal but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that- a) The Bidder must have manufactured, at least one (1) no. 345kV or above voltage class GIS circuit breaker bays@ based on technological support of the parent/principal, provided that the parent/principal meets the requirement stipulated in para 1.1 above. Further bidder must have either supplied or type tested above CB bay (as per IEC or equivalent standard) as on the originally scheduled last date of bid submission mentioned above. b) Further, the bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the parent/principal company) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s). ii. A confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India.
1.4 Route-4: 1.4 In case, the bidder is not a GIS manufacturer, he shall also be considered provided: i. The bidder must have erected and commissioned at least two (02) nos. GIS circuit breaker bays of 345kV or above voltage class in one (01) new GIS substation or switchyard during last seven (07) years and these bays must be in satisfactory operation# for at least two (02) years as on the originally scheduled last date of bid submission mentioned above. ii. The GIS must be offered from Indian manufacturer, who meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. iii. A legally enforceable undertaking (jointly with the GIS Manufacturer) (as per enclosed format in Section VI, Vol-I of bidding document) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s) is submitted along with the bid stating that GIS Manufacturer shall furnish performance guarantee for an amount of two (2) % of the GIS Portion**. This performance guarantee shall be in addition to the Contract Performance security to be submitted by the Bidder.
Note :- 1. (#)Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark. 2. (@) For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. In case bidder is a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in Route-1, 2, 3 & 4 above as the case may be shall be of that subsidiary company only (i.e. excluding its holding company). 4. In case bidder is qualifying through Route-1, type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents. 5. **Total price of items in supply, F&I and installation schedules mentioned under Activity titled “GIS portion” in BPS shall be considered for calculation of amount of CPG to be furnished by GIS manufacturer
Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder or of each Partner of a Joint Venture.
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder/Collaborator/ Parent/Principal/Partner of JV in case of Joint Venture/Indian GIS Mnaufacturer in support of meeting the requirement of para 1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of Bidder/Collaborator/ Parent/Principal/Partner of a JV/Indian GIS Manufacturer #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract
(Indicate nos. of GIS Circuit Breaker equipped bays of 345KV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above Substation have been in operation as on the originally scheduled last date of bid submission mentioned above
Scope of work involved under the Contract
(Tick whichever is/are applicable)
NOTE: type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents (Attachment-24 in Volume-III)
of Gas Insulated Switchgear (GIS) circuit breaker bays. of Gas Insulated Switchgear (GIS) circuit breaker bays.
In case of foreign entity, whether bidder have established/ commence the establishment of facility as Indian Subsidiary/ Group Company/ Joint Venture Company for manufacturing & testing of 765kV or above voltage level GIS in India (as per Companies Act 1956 or 2013 of India)
Whether bidder want to propose its above subsidiary/ Group Company/ Joint Venture Company as its associate for executing On-Shore Supply Contract
Foreign Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from India provided his Subsidiary or Group Company or a Joint Venture Company (JVC) must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay either should have been supplied or should have been type tested ( as per IEC or equivalent standard) as on the originally scheduled date of bid opening as mentioned above
Whether Undertaking (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
Format for the Indian Associate executing the On-Shore Supply and On-Shore Services Contract for a Foreign Entity submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, in support of meeting the requirement of para 1.1.1(i) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian Associate executing the On-Shore Supply and On-Shore Services Contract
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 No. of GIS/AIS Circuit Breaker equipped bays under the contract
(Indicate nos. of Circuit Breaker equipped bays of 220 kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
No. of years, the above CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format-B (Route-2):
Format in support of meeting the requirement of para 1.2 Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
1 Name of the Collaborator
2 Whether bidder have established manufacturing and testing facilities in India for 345KV or above voltage level Gas Insulated Switchgear (GIS)
3 Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder based on technological support of the collaborator have been supplied or Type tested
A if Type tested details of Type test Report
B Details of GIS supplied by them
i Name of Contract Undertaken for manufacturing 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
iv No. of 345KV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the substation or switchyard
Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Collaborator under the Contract.
Scope of work involved under the Contract
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit Breaker bays of 110KV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Collaborator(s) meets the technical experience criteria stipulated at 1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Collaborator(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Confirmation letter from the Collaborator(s) along with the bid stating that Collaborator(s) shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder/Manufacturer wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345kV or above voltage level GIS equipment in India furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-2 of Annexure-A(BDS))
Details of documents uploaded in support of the above stated experience
Format-C: (Route-3)
Format in support of meeting the requirement of para 1.3 Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
1 Name of the Bidder established as Subsidiary/JVC/Group company by its parent/principal Company
2 Name of the parent/principal Company
3 Whether bidder have established manufacturing and testing facilities in India for 345KV or above voltage level Gas Insulated Switchgear (GIS)
4 Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder have been supplied or Type tested based on Technological support of their Parent/ Principal Company
A if Type tested details of Type test Report
B Details of Gas Insulated Switchgear (GIS) Circuit Breaker Bays supplied by them
i Name of Contract Undertaken for manufacturing 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
iv No. of 345KV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the substation or switchyard
Whether 345KV or above voltage level Gas Insulated Switchgear (GIS) Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/Principal Company under the Contract.
Scope of work involved under the Contract
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit Breaker bays of 110KV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Parent/Principal Company meets the technical experience criteria stipulated at 1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Whether legally enforceable undertaking jointly by Bidder/Manufacturer and the Parent/Principal Company (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Confirmation letter from the parent/principal company along with the bid stating that parent/principal company shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder/Manufacturer wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 345KV or above voltage level GIS equipment in India furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
Name of the substation or switchyard
Whether 110KV or above voltage level Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/ Principal Company under the Contract.
If Yes, indicate the Name of Parent/ Principal Company(s)
No. of years, the above AIS/GIS Subatation(s) are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract for the above 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS bay as per IEC as on the originally scheduled date of bid opening
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.3 (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Parent Company/ Principal (refer para 1.3), if applicable: #REF!
Name of the 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufacturer (refer para 1.3), if applicable : 0 #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
4(a)(i) No. of Circuit Breaker bays under the contract
(Indicate nos. of Circuit Breaker bays of 110KV or above)
Name of the substation or switchyard
(a)(ii) No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Joint Deed of Undertaking executed between The Bidder and 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS Equipment Manufaturer has been enclosed with bid ? (in line with para 1.3 (b)(i) of Annexure-A (BDS)
Whether confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s) has been enclosed with bid? (in line with para 1.3(b)(ii) of Annexure-A (BDS)
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 110KV Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS equipment in India has been enclosed with bid ? (in line with para 1.3(b)(iii) of Annexure-A (BDS)
Details of documents uploaded in support of the above stated experience
Format-D: (Route-4)
Format in support of meeting the requirement of para 1.4(Route-4) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name :
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of the New substation or switchyard
Scope of work involved under the Contract (Tick whichever is/are applicable)
No. of years, the above GIS Circuit Breaker equipped bays have been in operation as on the originally scheduled last date of bid submission mentioned above.
Details of documents uploaded in support of the above stated experience
Name of the Proposed Indian GIS Manufacturer (as per the Route-4 of Annexure-A(BDS)
Whether above Indian GIS Manufacturer meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. (If Yes, Please mentioned the details in the Format-A/Format-B/Format-C above)
Whether Undertaking (Jointly with the GIS Manufacturer) (as per enclosed format in Section-VI, Vol-I of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
2.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 2.0 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive
b) Minimum Average Annual Turnover^(MAAT) of the bidder for best three years i.e. 36 months out of last five financial years of the bidder should be Rs. 39.254 Crore or equivalent for Package SS-144 package.
^Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other operative income / other income”.
For Bidders to qualify for more than one package, their financial position shall not be less than the sum of the requirement for the packages they propose to qualify for ( strike through if only one package)
c) Bidder shall have Liquid Assets (LA) and/or evidence of access to or availability of credit facilities of not less than Rs. 6.542 Crore or equivalent for Package SS-144.
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) as on the originally scheduled last date of bid submission as above, the financial position requirement as per para 2.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he completes five (5) years from the date of commercial production of such equipment (s) in India as on the originally scheduled last date of bid submission as above, the financial position requirements as specified at 2.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 2.0 (a) above of parent/principal shall be considered. (iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/ MSEs, meeting the specified requirements at Para 2.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 2.0 (b) & 2.0 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled last date of bid submission.
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or each of the Partners of a Joint Venture (in case of bidding by a Joint Venture) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
2.1 Financial Qualification Data: 2 or more
Name of the Bidder
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2020-21 No
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-1 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
C Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-2 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2020-21
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2020-21
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
3.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
JOINT VENTURE BIDS: a) In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively the complete requirements stipulated at para 1.0 and 2.0 (b) & (c) above. Further, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 2.0(a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum Financial Position criteria given at para 2.0 (b) & (c) iii. Each of the other partner(s) individually shall meet not less than 25% of the minimum Financial Position criteria given at para 2.0 (b) & (c) above The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 2.0 (b) & (c) above. b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above. ii. The remaining partner(s) of JV must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays@ of 345KV or above voltage level in one (1) substation or switchyard during the last seven (7) years in India and these bays@ must be in satisfactory operation# as on the originally scheduled last date of bid submission mentioned above. Note :- (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above ii. The remaining partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above or must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays* of 110kV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above.
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
Note :- 1. (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark 2. (*) For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. ($) In case of a JV bid involving an Indian Entity qualifying through Route-3 and its parent/ principal company as partner(s), the Indian Entity shall meet the applicable Financial Position criteria on its own and not based on its parent/principal company.
4 The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
B For Name of Other Partner-1 of JV
C For Name of Other Partner-2 of JV
Format in support of meeting the requirement of para 3.0(b)(ii) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Partner of JV
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of AIS/GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
No. of AIS/GIS Circuit Breaker equipped bays under the above contract (Indicate nos. of AIS/Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 345KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs.)
Name of the substation or switchyard
Scope of work involved under the Contract (Tick whichever is/are applicable)
No. of years, the above AIS/GIS Circuit Breaker equipped bays have been in operation as on the originally scheduled last date of bid submission mentioned above.
Details of documents uploaded in support of the above stated experience
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
Audited balance sheet and income statements for the last five years as per the following:
For Name of Other Partner-1 of JV For Name of Other Partner-2 of JV
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed
1st Year Yes Yes
2nd Year Yes Yes
3rd Year Yes Yes
4th Year Yes Yes
5th Year Yes Yes
6 In addition to the data/details furnished as above, the information available at ‘Information on Record’ (IoR) portal of POWERGRID may also be considered as our submission for purpose of QR compliance.
Date : Printed Name :
Place : Designation :
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-4
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-4 (A)
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-4 (A)
(List of Special Maintenance Tools & Tackles)
S.No. For Equipment Item Description Unit Quantity
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-5
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We hereby furnish the details of the all major items of supply or services i.e. items, whose price is more than 10% of the Bid Price, we propose to buy for the purpose of furnishing and installation of the subject 400kV GIS Substation Package SS-151 :
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
2. We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-5A
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the package. i.e.,400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Sample Forms and Procedures (FORMS), Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-5A
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-6
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Reason for change The change in Bid Prices if the deviation is withdrawn and the Bidder conforms to the Specifications
Any proposed deviation will be applicable only for the bidder whose bid is substantially responsive in accordance with Clause 22, Section ITB, Vol. I of the bidding documents. If a bid is not substantially responsive, it will be rejected and may not subsequently be made responsive by the bidder by correction of the non-conformity.
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] Attachment-7
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Details of Alternative Bid)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
No Alternative Bid
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-9 ATTACHMENT-9
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Work Completion Schedule)
Bidder’s Name and Address : To
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject package i.e., 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Extension of 400/220/132kV Pandiabili GIS Substation under ERBS-I Extension of 400/220/132kV Rangpo GIS Substation under ERBS-II Bay Extension of Misa GIS S/s under NERES-XXVIII
1 Detailed Engineering and drawing submission a) commencement
2 Procurement of equipment/ components & assembly a) commencement
3 Type Tests a) commencement
4 Manufacturing a) commencement
5 Shipments & Delivery a) commencement
6 Establishment of site office
7 Installation at Site a) commencement
8 Testing & Pre-commissioning a) commencement
9 Trial Operation a) commencement
Date : 00-Jan-00 Printed Name : Printed Name 0
Place : 0 Designation: Designation 0
Note: Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-10
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Guarantee Declaration)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We confirm that the equipments offered shall have minimum (or a maximum, as the case may be) performance specified in Technical Specifications. We further guarantee the performance/ efficency of the equipments in response to the Technical Specifications
We declare that the ratings, performance figures and availability of the system furnished by us for subject Package covered under this specification are guaranteed by us. In particular, we declare that the 1) 10MVA, (220/V3)/(132/V3) kV, 1-phase Autotransformer; 2) 160MVA, 220/132/33 KV, 3-phase Autotransformer as per scope of package) offered under this package shall meet the maximum loss requirement as stipulated in Technical Specifications
We confirm that the equipment offered shall have minimum (or a maximum, as the case may be) performance specified in technical specification. We further guarantee the performance/efficiency of the equipments in response to the technical specification.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-11
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Note: The information in similar format should be furnished for each partner of joint venture in case of joint venture bid.
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-11
(Information regarding Ex-employees of POWERGRID in our Organisation)
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-11
(Information regarding Ex-employees of POWERGRID in our Organisation)
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
SPEC. NO.: CC/NT/W-GIS/DOM/A04/25/12409 ATTACHMENT-12
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Price Adjustment Data)
Bidder’s Name and Address (Lead Partner of) : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No.-2
0 Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the GIS Substation Package. The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as on thirty (30) days prior to date of opening in line with Appendix-2, Section-VI, Volume-I
A) For Ex-Works Price Component of AIS Equipment
I Current Transformer
a) Raw Material
b) Labour l= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
I Capacitive VoltageTransformer
a) Raw Material
b) Labour l= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= l= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
II Surge Arrester
a) Raw Material
b) Labour I= Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
III PVC/XLPE Insulated Power and Control Cable
a) a=PVC Compound 0.15
b) Published Price of Metal IEEMA
i) Aluminium per MT IEEMA
ii) Copper per MT IEEMA
c) Weight in MT of Metal per kM (Size wise)
IV Sub Station Structures (including Bolts & Nuts)
i) Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
a) Raw Materials
i) a=Structural steel a= 0.58 JPC Market Price (Retail) for average Price of Steel Angles of size 50 x 50 x 6 mm of all cities in Rs./MT as published by Joint Plant Committee(JPC).
ii) b=Electrolytic Zinc b= 0.16 IEEMA
b) Labour l= 0.11 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
VIII. Series Reactor [ 420 kV, 12 ohm, 2500A, 1-ph air core dry type Series Reactor]
a) Raw Material Copper(a)
i) Aluminium(a) Aluminium(a)
b) Labour I= 0.85 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The value of coefficient for raw materials: a=0.65 to 0.73 and value of coefficient for labour shall be between 0.12 and 0.20, so that sum of all the coefficients including labour shall be a+l=0.85
B. For Installation (including Civil Works) Price Component
I Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’)
i) Labour I= l= 0.80 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
II Supply & Placement of Reinforcement Steel
i) HSD a= 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= l= 0.05 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
iii) Manufacture of Basic Metals b= 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
III For Concereting
i) HSD a= 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= l= 0.10 Indian field labour index – namely All-India Average Consumer Price Index Numbers for Industrial Workers (monthly) (Base 2016=100), as published by Labour Bureau, Shimla, Government of India (http://labourbureaunew.gov.in)
iii) Manufacture of cement, lime and plaster b= 0.30 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iv) Cutting, shaping and finishing of stone c= 0.20 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-13
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Declaration regarding Social Accountability)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-14
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited 0 0
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as 0 0
"POWERGRID", 0 0
having its Registered Office at 1 having its Registered Office at ,
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII, [Specification No.: CC/NT/W-GIS/DOM/A04/25/12409]
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII, [Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] values full compliance with all relevant laws of the land, rules, regulations, economic use of resources, and of fairness / transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
during his participation in the tender process and during the contract execution :
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration/Conciliation clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral/conciliation or judicial proceedings (arising out of the arbitral/conciliation proceedings) by the parties in connection with the disputes/differences arising out of the subject contract
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] Attachment-15(rev) 0
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
A1 Interest Bearing Initial Advance
Supply Portion:
Services Portion:
A2 Interest Bearing Engineering Advance :
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment. No
3. (c ) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d ) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6 PF Registration No. of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Contact Details
10 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Saving Account
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-16
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Additional Information)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (q) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
Certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(q)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder : 0 1
Name of the Banker by whom certificate issued 2 or more
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(q)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years. A consistent history of awards invlolving litigation against the Bidder or any patner of JV may result in rejection of Bid. [(Refer ITB Clause 9.3 (q)(ii))]
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of the Clients Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Figures Rs in Million
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
4.3 Details of Provident Fund Code Number of the Bidder
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-17
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
Dear Sirs, 1. We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us. 2. We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Instruction for printing & submitting Safety Pact
1. The requisite format of Safety Pact is getting generated automatically and displayed here below:
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other four pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Safety Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (s).
Power Grid Corporation of India Limited 0 0
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as 0 0
"POWERGRID", 0 0
0 1 having its Registered Office at ,
having its Registered Office at, 0, 0, 0 2 or more AND
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409]
POWERGRID values full compliance with all relevant laws and regulations and the principles of Safety, Health& Environment in its relations with its Bidders/ Contractors
In order to achieve these goals, POWERGRID and the above named Bidder / Contractor enter into this agreement called “Safety Pact” which will form part of the Bid. It is hereby agreed by and between the parties as under:
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 1 of 5
Section I – Commitments of POWERGRID:
POWERGRID commits itself to take all measures necessary to prevent accidents duringConstruction and Operation of the Transmission Assets and to observe the following:
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Safety Pact' which will form a part of the bid.
1 POWERGRID recognizes and accepts its statutory responsibilities for ensuring construction, operation and maintenance of equipments and for the provision of safe methods of work and safe working conditions.
2 POWERGRID recognizes and accepts its statutory responsibilities for ensuring safety of not only its employees but also that of the Contracting Agencies as Principal Employer.
3 POWERGRID shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction as well as Operation & Maintenance of the Transmission Assets.
4 POWERGRID shall conduct necessary awareness and training programmes to its Employees to augment the various safety requirements to be followed during Construction and Operation & Maintenance of the Transmission Assets from time to time
5 POWERGRID shall, from time to time, issue necessary guidelines,instructions and deterrents to its employees as well as to the Contracting Agencies, to update them to take necessary preventive measures to avoid repetition of similar accident attributes.
6 POWERGRID shall review and provide necessary guidanceto the Contracting Agencies, as and when, any abnormality / special situations are brought to its notice by the Contracting Agencies during execution of the Transmission Projects being executed by them.
7 POWERGRID shall conduct periodical surveillance site inspections / audits to identify the unsafe conditions and unsafe actions, and bring them to the knowledge of the Contracting Agencies for taking timely corrective actions.
8 POWERGRIDshall investigate all accidents, fatal as well as non-fatal, to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents, and fix responsibility for the lapses leading to the accident.
9 POWERGRID shall augment the training to the workers and supervising personnel of the Contracting Agencies, as per schedules, upon nomination by the Contracting Agencies in reasonable time frame.
10 POWERGRID shall exercise the right to claim and recover compensation from the Contracting Agencies in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the applicable Laws and contractual specifications / guidelines in vogue / issued by POWERGRID from time to time.
11 Section II – Commitments of the Bidder / Contractor:
The Bidder / Contractor commits himself to take all measures necessary to prevent / minimise accidents at their construction / erection sites and to observe the following:
1 The Bidder / Contractor recognizes and acceptsthe statutory and comprehensive responsibility for ensuring safe construction and Testing & Commissioning in the Transmission Projects being executed by thembyproviding safe methods of work, working conditions and Tools & Plants for human safety.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 2 of 5
2 The Bidder / Contractor recognizes and accepts the responsibilities for ensuring safety of not only their employees but also that of the Sub-contractors, Principal Employer and the general public during execution of the Transmission Projects / works.
3 The Bidder / Contractor shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction of the Transmission Assets.
4 The Bidder / Contractor shall endeavour continuous development of safe methods of work to ensure that the effect of risks and perils are minimised to the extent possible and implement the same at their worksites.
5 The Bidder / Contractor shall conduct periodical Training to their Employees as well as to that of theirSub-contractors for safety awareness during construction works being executed by them.
6 The Bidder / Contractor shall provide all requisite Tools & Plants required for the work and ensure their healthiness by periodical inspections / testing as required. Unhealthy and sub-standard Tools & Plants will be immediately removed from site as and when they are identified.
7 The Bidder / Contractor shall,at their cost, provide all necessary Personal Protective Equipments such as Double Lanyard Safety Belts, Appropriate Fall Arrest Systems, Safety Helmets, Foot Wear, Hand Gloves, etc., as required for various activities pertaining to execution of the Projects / works, confirming to relevant Indian Standards.
8 The Bidder / Contractor shall ensure that dedicated qualified Safety Officers are posted in the construction projects being executed by them and ensure that the Safety Officer visits each and every gang periodically and conducts audits / inspections to identify the unsafe conditions and unsafe actions, to be rectified by the site supervising personnel promptly.
9 The Bidder / Contractor shall conduct appropriate medical checks-up for the workers before deploying them at their construction sites to ensure that only those who are medically fit are deployed in the Projects / works to be executed by them. The copy of the Medical Reports shall be provided by the Bidder / Contractor to POWERGRID, whenever requested by POWERGRID.
10 The Bidder / Contractor shall screen the workers before deploying them at their construction sites to ensure that only those with the skills, experience and competence to work at heightand also medically fitfor work at height are deployed for work at height in the Projects executed by them.
11 The Bidder / Contractor shall ensure daily before starting the work thattheir site Supervising Personnel / Safety Officer briefs the workers about the work for the day and the safety measures / precautions required to be taken by them.
12 The Bidder / Contractor shall investigate all the accidents at their working sites to ascertain the lapses leading to the incident and the precautionary / corrective measures required to be taken to avoid recurrence of such accidents. These accidents will be reviewed at the Board Management level of the Agencies and the findings / recommendations will be put up to POWERGRID Apex Safety Board within the stipulated period.
13 The Bidder / Contractor shall ensure that all accidents, whether fatal or non-fatal in nature, will be informed to POWERGRID, in writing, immediately on the occurrence of the same,and in any case, within not more than 24 hours of occurrence of the same.
14 The Bidder / Contractor shall ensure that in case of any accident, all necessary medical help / supportshall be provided to the victims / injured till they are completely fit to return to work.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 3 of 5
15 The Bidder / Contractorshall ensure that in case of fatal accidents, all statutory Authorities, including Police, concerned Labour Dept. Officials, concerned Workmen Compensation Commissioner, etc., will be intimated in writing as required by the statutory Law, and followed up for compliance of all statutory obligations. The Bidder / Contractor shall own full responsibility of timely accident reporting to various authorities, including POWERGRID.
16 The Bidder / Contractor shall ensure that in case of fatality or serious injury leading to permanent disablement of the victims, the compensation amount will be deposited with the concerned authorities, as required by the Laws, and followed up for early disbursement to the beneficiaries of the victims.
17 The Bidder / Contractor assures that they shall co-operate to the fullest extent for carrying out any investigation of the accidents at their work sites by POWERGRID to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents. All factual details of the occurrence of the accident will be provided to POWERGRID, as and when required.
18 The Bidder / Contractor assures that they take full responsibility of meeting the statutory obligations in case of accidents, and in case of any reference by any Statutory Body at a later date also, they shall provide all information to POWERGRID and meet all the statutory obligations, including payment of additional compensation, if any.
19 The Bidder / Contractor assures that in case of any inspection of their work site or Notice by any Statutory Authority, they shall comply promptly and inform POWERGRID Site Officials of the same, and also provide all necessary information and assistance for smooth compliance of the observations / instructions of such Authorities.
20 The Bidder / Contractor accepts the provisions regarding safety, including payment of any sums to POWERGRID, in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the Contractual Conditions, Safety Planand the Safety Pact, and confirm to abide by the same.
Section III – Equal treatment to all Bidders / Contractors:
1 POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
2 POWERGRID will disqualify, from the tender process, any bidder/ take punitive actions on the bidder, who does not sign this Pact or violate its provisions.
Section IV – Pact Duration:
This Pact begins when both parties have legally signed it. It expires for the successful Bidder / Contractor after closure of the contract and, for all other Bidders, after the contract has been awarded.
Section V – Other Provisions:
1 This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration/Conciliation clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under the Safety Pact.
2 Changes and supplements need to be made in writing, which shall come into force only upon mutual agreement / acceptance.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 4 of 5
3 If the Contractor is a partnership firm or consortium of Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venue partners, as applicable as per the Tender Specifications.
4 Nothing in this agreement shall affect the rights of the parties available under General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
5 Should one or several provisions of this agreement turn out to be invalid, the reminder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Name & Address: Name & Address:
Witness 2 : Witness 2 :
Name & Address: Name & Address:
Safety Pact Page 5 of 5
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-19
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof, forming part of our First Envelope :
(i) there are no discrepancies/inconsistencies and deviations/omissions/ reservations to the Bidding Documents, in the Second Envelope bid;
We also confirm that in case any discrepancies/ inconsistencies and deviations/ omissions/ reservations, as referred to in para (i) and (ii) above, is observed in the Second Envelope, the same shall be deemed as withdrawn/rectified without any financial implication, whatsoever to POWERGRID. However, in case of any arithmetical errors, the same shall be governed as per the provision of ITB Sub-Clause 27.2 read in conjunction with BDS
Date 0-Jan-1900 Printed Name 0
Place 0 Designation 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-23-A
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
Declaration by the Bidder in line with Annexure-A (BDS) regarding already having manufacturing & testing facilities for 400kV or above voltage level GIS in India as on the originally scheduled date of bid opening.
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We hereby confirm that we have already incorporated Subsidiary Company */Group Company * /Joint Venture Company * as per Companies Act of India, in line with GCC clause 5.1 to manufacture 400KV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned in Annexure-A (BDS).
We further confirm that the said Subsidiary Company */Group Company * /Joint Venture Company * has manufacturing & testing facilities for 400kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned in Annexure-A (BDS).
Further, we are furnishing the requisite document in support of the above which are attached herewith.
* Stike out which ever is not applicable
Date 0-Jan-1900 Printed Name 0
Place 0 Designation 0
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] ATTACHMENT-23-B
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII
Declaration by the Bidder in line with Annexure-A (BDS) regarding commencement of construction activities for establishment of 400kV or above voltage level GIS manufacturing and testing facilities in India as on the originally scheduled date of bid opening.
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We hereby confirm that we have already incorporated Subsidiary Company */Group Company * /Joint Venture Company * as per Companies Act of India, in line with GCC clause 5.1 to manufacture 400KV or above voltage level GIS in India and have commenced the Construction activities for establishment of manufacturing & testing facilities for 400kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned in Annexure-A (BDS)
Regarding incorporation of Subsidiary Company */Group Company * /Joint Venture Company * in India and Commencement of Construction activities, we here by declare as under :
a) Our Subsidiary Company */Group Company * /Joint Venture Company * has been incorporated on ___________________ as per Companies Act of India (Documentary Evidence is Attached herewith).
b) Land is in legal and physical possession (Documentary evidence is attached herewith)
c) All Building designs, ordering of civil works have been completed and civil work at site have commenced (Documentary evidence is attached herewith)
d) Purchase order for major long delivery testing equipment have been placed with delivery and commissioning schedule (Documentary evidence is attached herewith)
e) Action plan for availability of trained manpower to take up manufacturing and testing of GIS module is attached herewith.
* Stike out which ever is not applicable
Date 0-Jan-1900 Printed Name 0
Place 0 Designation 0
Before filling up the Bid Form, the Bidder is required to fill up the details as under :
1 Tick whichever is applicable:
1 Enter Details of Amendments:
Amendments to Bidding Documents issued:
6* In case the Bidder is MSE, then insert the Designated Authority under GoI with which they are Registered: ghtg
* applicable for MSE only
[Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] Bid Form (First Envelope) 1 st 1 January 1 one
2 nd 2 February 2 two
BID FORM (First Envelope) 3 rd 3 March 3 three
4 th 4 April 4 four
Bid Proposal Ref. No.: 5 th 5 May 5 five
Date : 00-Jan-00 7 th 0 6 June 7 seven
8 th 1 7 July 8 eight
To: 9 th January 8 August 9 nine
Contract Services 10 th 1900 9 September 10 ten
Power Grid Corporation of India Ltd., 11 th 10 October 11 eleven
"Saudamini", Plot No. 2, Sector 29 12 th 11 November 12 twelve
Gurgaon (Haryana) - 122001 13 th 12 December 13 thirteen
14 th Zero 14 fourteen
15 th () 15 fifteen
Name of Contract : 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES-XXVIII [Specification No.: CC/NT/W-GIS/DOM/A04/25/12409] the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently).0 16 th 16 sixteen
Dear Ladies and/or Gentlemen, 17 th 17 seventeen
1.0 Having examined the Bidding Documents, including Amendment Nos. dated 00/01/1900, the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 0 18 th 18 eighteen
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2 19 th 19 nineteen
2.0 Attachments to the Bid Form (First Envelope) 20 th 20 twenty
2.1 In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments to the Bid Form : 21 st
(a) Attachment 1: NOT APPLICABLE Bank Draft 22 th
Banks certified Cheque
(b) Attachment 2: Attachment 2: A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. *Further the requisite deed of Joint Undertaking as per stipulated qualification requirement in Annexure-A (BDS) has also been furnished as per your format. * Delete if not applicable A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee 23 th
(c) Attachment 3: The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents [Attachment – 3(QR)]. 24 th
* Further, the required deed of Joint Venture Agreement signed by us and our Partners has also been furnished as per your format [Attachment – 3(JV)].
(d) Attachment 4: The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facility offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4 . Moreover, a list of Special Tools & Tackles to be furnished by us, the cost of which is included in our Bid Price, is also enclosed as per your format as Attachment- 4A. 25 th
(e) Attachment 5: The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A: (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works
(g) Attachment 6: The variation and deviations from the requirements of the Conditions of Contract, Bid Data Sheet and other commercial conditions, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter-alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7: The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. [NOT APPLICABLE] 28 th
(i) (i) Attachment 8 (a): Manufacturer’s Authorisation Forms 29 th
(i) (ii) Attachment 8 (b) : Manufacturer’s Authorization Form (applicable for GIS Manufacturer(s) proposed by bidder qualifying through Route-4 of Qualifying Requirements) (If Applicable) 29 th
(j) Attachment 9: Work Completion Schedule
(k) Attachment 10: Guarantee Declaration
(l) Attachment 11: Information regarding ex-employees of Employer in our firm
(m) Attachment 12: Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents
(n) Attachment 13: Declaration regarding Social Accountability
(o) Attachment 14: Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15: Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16: Additional information
(r) Attachment 17: Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18: Safety Pact
(t) Attachment 19: Declaration
(u) Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder is attached herewith
(v) Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII Order and MoP Order, if applicable
(w) Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII Order and MoP Order, if applicable
(x) Attachment 23: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
(y) Attachment 24: Confirmation in regard to Design and Type Test (to be furnished in case bidder is proposing to qualify through Note-4 under Route-1 of QR)
(z) Attachment 25: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
(aa) Attachment 26: Undertaking by the bidder regarding Compliance of DMI&SP policy
(bb) Attachment 27: VOID
(cc) Attachment 28: Certification by the Bidder as per DoE Order in line with ITB Clause 2.1 (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture)
(dd) Attachment 29: Bid Securing Declaration to be submitted by the Bidder
(ee) Attachment 30: Undertaking regarding submission of original/Hard copy part of the bid
(ff) Attachment 31: Declaration by the bidder for ‘Code of Integrity for Public procurement
(gg) Attachment 32: Declaration by the bidder for Acknowledgement and Acceptance of ‘Supplier Code of Conduct’
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
5.0 Construction of the Contract
, whose capacity, capability and experience are enclosed with our Bid as our Associate(s) for the purpose of executing the ‘Second Contract’ and / or the ‘Third Contract’ and written unequivocal consent of the above mentioned proposed Associate(s) to work as your independent Contractor, on the same terms and conditions as offered by us to you in this bid, is also enclosed with the Bid Form. We shall, however, be overall responsible for the execution of all the three Contracts.
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, In-transit insurance, unloading, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security-Not Applicable
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) GCC 40 Conciliation
(o) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us shall make our bid non-responsive as per provision of bidding documents and rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work on Facilities immediately upon your Notification of Award to us, and to achieve Completion within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide an Advance Payment Security and Performance Security(ies) in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of Six (06) months after the date of opening of Techno - Commercial Part i.e. First Envelope as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
*12.0 (for Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 1
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012 Notification dated 01/06/2020 ,26/06/2020 and 19/01/2022 read in conjunction with related notifications issued from time to time for such enterprises. Yes 2 2
13.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain
Yours faithfully,
For and on behalf of : 0
Date : 00 January 1900 Printed Name: 0
Place : 00-Jan-00 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
(State/Province to be indicated)
Name of Principal Officer :
Address of Principal Officer :
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only EURO Four Thousand Nine Hundred Sixty Only RMB Ten Thousand Three Hundred Fifty Two Only INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
85 Eighty Five 60 Sixty 52 Fifty Two 47 Forty Seven
8 Eight Hundred 9 Nine Hundred 3 Three Hundred 6 Six Hundred
55 Fifty Five Thousand 4 Four Thousand 10 Ten Thousand 91 Ninety One Thousand 0 0 0 0 0 plus
1 One Lac 0 0 6 Six Lac 0 0 0 0 1
1 One 1 One 1 One 1 One 0 0 1 0 1
2 Two 2 Two 2 Two 2 Two 0 0 1 1 0
3 Three 3 Three 3 Three 3 Three 0 0 1 1 1
4 Four 4 Four 4 Four 4 Four 0 1 0 0 0
5 Five 5 Five 5 Five 5 Five 0 1 0 0 1
6 Six 6 Six 6 Six 6 Six 0 1 0 1 0
7 Seven 7 Seven 7 Seven 7 Seven 0 1 0 1 1
8 Eight 8 Eight 8 Eight 8 Eight 0 1 1 0 0
9 Nine 9 Nine 9 Nine 9 Nine 0 1 1 0 1
10 Ten 10 Ten 10 Ten 10 Ten 0 1 1 1 0
11 Eleven 11 Eleven 11 Eleven 11 Eleven 1 1 1 1 1 USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen 0 0 0 0 0 +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen 0 0 0 0 1 /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen 0 0 0 1 0 /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen 0 0 0 1 1
20 Twenty 20 Twenty 20 Twenty 20 Twenty 0 0 1 0 0
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One 0 0 1 0 1
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two 0 0 1 1 0
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three 0 0 1 1 1
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four 0 1 0 0 0
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five 0 1 0 0 1
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six 0 1 0 1 0
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 0 1 0 1 1
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 0 1 1 0 0
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 0 1 1 0 1
30 Thirty 30 Thirty 30 Thirty 30 Thirty 0 1 1 1 0
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One 1 1 1 1 1 USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only EURO Four Thousand Nine Hundred Sixty Only RMB Ten Thousand Three Hundred Fifty Two Only INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
85 Eighty Five 60 Sixty 52 Fifty Two 47 Forty Seven
8 Eight Hundred 9 Nine Hundred 3 Three Hundred 6 Six Hundred
55 Fifty Five Thousand 4 Four Thousand 10 Ten Thousand 91 Ninety One Thousand 0 0 0 0 0 plus
1 One Lac 0 0 6 Six Lac 0 0 0 0 1
1 One 1 One 1 One 1 One 0 0 1 0 1
2 Two 2 Two 2 Two 2 Two 0 0 1 1 0
3 Three 3 Three 3 Three 3 Three 0 0 1 1 1
4 Four 4 Four 4 Four 4 Four 0 1 0 0 0
5 Five 5 Five 5 Five 5 Five 0 1 0 0 1
6 Six 6 Six 6 Six 6 Six 0 1 0 1 0
7 Seven 7 Seven 7 Seven 7 Seven 0 1 0 1 1
8 Eight 8 Eight 8 Eight 8 Eight 0 1 1 0 0
9 Nine 9 Nine 9 Nine 9 Nine 0 1 1 0 1
10 Ten 10 Ten 10 Ten 10 Ten 0 1 1 1 0
11 Eleven 11 Eleven 11 Eleven 11 Eleven 1 1 1 1 1 USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen 0 0 0 0 0 +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen 0 0 0 0 1 /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen 0 0 0 1 0 /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen 0 0 0 1 1
20 Twenty 20 Twenty 20 Twenty 20 Twenty 0 0 1 0 0
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One 0 0 1 0 1
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two 0 0 1 1 0
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three 0 0 1 1 1
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four 0 1 0 0 0
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five 0 1 0 0 1
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six 0 1 0 1 0
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 0 1 0 1 1
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 0 1 1 0 0
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 0 1 1 0 1
30 Thirty 30 Thirty 30 Thirty 30 Thirty 0 1 1 1 0
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One 1 1 1 1 1 USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Package Name 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
Package Code 400kV GIS substation package SS-135 (Re-tender) Bought-out
Specification No. Spec No:CC/NT/W-GIS/DOM/A04/25/12409
Spec No:CC/NT/W-GIS/DOM/A04/25/12409
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-4, Sch-5, Sch-7, Discount (Optional), Guarantee Declariation and Bid Form 2nd Envelope.
2 All the cells in Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
Spec No:CC/NT/W-GIS/DOM/A04/25/12409
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-5, Sch-7 and Bid Form 2nd Envelope.
2 All the cells in Sch-4 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● Fill up applicable rate of Excise Duty. The amount of Excise Duty on the items mentioned as Direct in the mode of transaction in Schedule-1 shall be calculated automatically at the rate mentioned by the bidder here.
● Segregate and fill up the amount on which Sales Tax shall be applicable out of Ex-works supply items mentioned as direct in the mode of transaction in Schedule-1. Applicable Excise Duty on this amount will be calculated automatically at the rate mentioned by the bidder. Further, fill up the rate of applicable Sales Tax. Amount of Sales Tax shall be automatically calculated on the amount mentioned by the bidder as subjected to Sales Tax plus applicable Excise Duty at the rate mentioned by the Bidder.
● Difference of total amount quoted by the bidder as Direct Transaction and the amount mentioned by him subjected to Sales Tax shall be considered as the amount on which VAT shall become applicable and the same shall be calculated & displayed automatically. Applicable Excise Duty on this amount at the rate mentioned by the bidder shall also be calculated & displayed automatically. Fill up the rate of applicable VAT. The amount of VAT shall be calculated automatically on the amount considered to be subjected to VAT plus applicable Excise Duty at the rate mentioned by the bidder here.
● Amount as per details filled up by the bidder in the work sheets Entry Tax, Octroi and other Taxes & Duties shall be displayed in this work sheet Sch-5 but will not be added to the grand total and shall be considered as applicable.
● Click at the links to go to the work sheets Entry Tax, Octroi and other Taxes & Duties one by one.
● Fill the description, amount and rate of applicable Entry Tax. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Fill the description, amount and rate of applicable Octroi. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
Other Taxes & Duties :
● Fill the description, amount and rate of applicable Other Taxes & Duties. Total of this worksheet shall be displayed in Sch -5 (Taxes & Duties)
● Click at the link to go back to Sch-5.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid form 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Sole Bidder 1
JV (Joint Venture) Other Partner
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 1 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 2 (more, if any) DEF
Address of other Partner - 2 (more, if any)
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule-1
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(SCHEDULE OF RATES AND PRICES)
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurugram (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted.
(All Prices are in Indian Rupees)
SI. No. Activity Description Material Code HSN Code Whether HSN in column ‘6’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST # Item Description Unit Qty. Unit Ex-Works Price (excluding GST) Total Ex-Works Price (excluding GST) GST Before Discount Discount Total Price after discount GST After Discount
Re-tender-NIT-BOQ-Pandiabil SS (ERBS-I) 0.00
1 AIS EQUIPMENT 1000004401 85462040 18 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED 0 0 0.00 0.00 0.00
2 AIS EQUIPMENT 1000020419 85354010 18 336kV Surge Arrester (1-phase) EA 6 INCLUDED 0 0 0.00 0.00 0.00
3 AIS EQUIPMENT 1000004535 85359090 18 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 INCLUDED 0 0 0.00 0.00 0.00
4 AIS EQUIPMENT 1000000004 85176210 18 400kV,3150A,1.0mH ,63kA Line Trap EA 4 INCLUDED 0 0 0.00 0.00 0.00
5 AIS EQUIPMENT 1000004400 85462040 18 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 INCLUDED 0 0 0.00 0.00 0.00
6 400KV GIS EQUIPMENT 1000004287 85389000 18 420kV, 3000A, 63kA, Single phase, SF6Gas Insulated Bus Duct (GIB) outsideGIS Hall alongwith associated supportstructure M 600 INCLUDED 0 0 0.00 0.00 0.00
7 400KV GIS EQUIPMENT 1000032699 85389000 18 3150A, 63KA, 1SEC SINGLE PHASE 420KV SF6 TO AIR BUSHING EA 6 INCLUDED 0 0 0.00 0.00 0.00
8 400KV GIS EQUIPMENT 1000032802 85359030 18 420KV, 4000A,63KA GIS BUSBAR MODULE EXTENSION SET 2 INCLUDED 0 0 0.00 0.00 0.00
9 400KV GIS EQUIPMENT 1000004364 85389000 18 Single phase/3-phase 420kV GIS earthing switch of including maincircuit, enclosure, driving mechanism. SET 1 INCLUDED 0 0 0.00 0.00 0.00
10 400KV GIS EQUIPMENT 1000004638 85359030 18 420 kV, 3150 A, 63 kA, SF6 GIS Linefeeder bay module(without PIR) as perSection-Project, Technicalspecification SET 1 INCLUDED 0 0 0.00 0.00 0.00
11 400KV GIS EQUIPMENT 1000004505 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 1 INCLUDED 0 0 0.00 0.00 0.00
12 400KV GIS EQUIPMENT 1000004637 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00
13 400KV GIS EQUIPMENT 1000009713 85389000 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 3 INCLUDED 0 0 0.00 0.00 0.00
14 400KV GIS EQUIPMENT 1000077608 85359030 18 420KV,4000A, 63KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULESUITABLE FOR EXTENDING EXISTING HYOSUNG MAKE GIS BUS BAR/DUCT AS PERTECHNICAL SPECIFICATION SET 2 INCLUDED 0 0 0.00 0.00 0.00
15 CRP 1000055446 85371000 18 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 3 INCLUDED 0 0 0.00 0.00 0.00
16 CRP 1000025391 82032000 18 Relay Test kit EA 1 INCLUDED 0 0 0.00 0.00 0.00
17 CRP 1000003398 85371000 18 400kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0 0.00 0.00 0.00
18 AUG-SAS 1000003409 85371000 18 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 3 INCLUDED 0 0 0.00 0.00 0.00
19 AUG-SAS 1000003411 85371000 18 Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 1 INCLUDED 0 0 0.00 0.00 0.00
20 ERECTION HARDWARE & INSULATOR 1000011336 72169990 18 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED 0 0 0.00 0.00 0.00
21 ILLUMINATION 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED 0 0 0.00 0.00 0.00
22 ILLUMINATION 1000014546 94059900 18 Lighting Panel (Indoor) type ACP-1 as per technical specification EA 1 INCLUDED 0 0 0.00 0.00 0.00
23 ILLUMINATION 1000004795 94059900 18 5/15 A, 240V: Indoor Receptacle 3-pin type modular (type RI) as pertechnical specifications EA 1 INCLUDED 0 0 0.00 0.00 0.00
24 ILLUMINATION 1000001050 94059900 18 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 1 INCLUDED 0 0 0.00 0.00 0.00
25 ILLUMINATION 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED 0 0 0.00 0.00 0.00
26 ILLUMINATION 1000038039 94051090 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED 0 0 0.00 0.00 0.00
27 ILLUMINATION 1000004952 94059900 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 2 INCLUDED 0 0 0.00 0.00 0.00
28 VMS 1000030433 85287390 18 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 INCLUDED 0 0 0.00 0.00 0.00
29 LT SWITCHGEAR 1000004304 85371000 18 415V ACDB (Extn.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
30 PLCC Equipment at Pandiabili end 1000010014 85176210 18 Coupling device for PLCC SET 2 INCLUDED 0 0 0.00 0.00 0.00
31 PLCC Equipment at Pandiabili end 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0.00 0.00 0.00
32 PLCC Equipment at Pandiabili end 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 2 INCLUDED 0 0 0.00 0.00 0.00
33 PLCC Equipment at Pandiabili end 1000010638 85176210 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0.00 0.00 0.00
34 PLCC Equipment at Pandiabili end 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0.00 0.00 0.00
35 PLCC Equipment at Pandiabili end 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED 0 0 0.00 0.00 0.00
36 PLCC Equipment at Pandiabili end 1000001104 85176210 18 2wire telephone equipment EA 1 INCLUDED 0 0 0.00 0.00 0.00
37 PLCC Equipment at Talchar end 1000010014 85176210 18 Coupling device for PLCC SET 2 INCLUDED 0 0 0.00 0.00 0.00
38 PLCC Equipment at Talchar end 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED 0 0 0.00 0.00 0.00
39 PLCC Equipment at Talchar end 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 2 INCLUDED 0 0 0.00 0.00 0.00
40 PLCC Equipment at Talchar end 1000010638 85176210 18 Digital Protection Coupler EA 2 INCLUDED 0 0 0.00 0.00 0.00
41 PLCC Equipment at Talchar end 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0.00 0.00 0.00
42 PLCC Equipment at Talchar end 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED 0 0 0.00 0.00 0.00
43 PLCC Equipment at Talchar end 1000001104 85176210 18 2wire telephone equipment EA 1 INCLUDED 0 0 0.00 0.00 0.00
44 Power&Control Cable (LS) 1000000443 85446020 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
45 Power&Control Cable (LS) 1000000442 85446020 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
46 Power&Control Cable (LS) 1000000444 85446090 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
47 Mandatory spares AIS & General-LS 1000025943 85359090 18 Spare-420kV CVT 1 SET 1 INCLUDED 0 0 0.00 0.00 0.00
48 Mandatory spares AIS & General-LS 1000025940 85462040 18 Spare-420kV BPI SET 1 INCLUDED 0 0 0.00 0.00 0.00
49 Mandatory spares AIS & General-LS 1000019927 85389000 18 Spares-Substation Automation System LS 1 INCLUDED 0 0 0.00 0.00 0.00
50 Mandatory spares AIS & General-LS 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 INCLUDED 0 0 0.00 0.00 0.00
51 Mandatory spares AIS & General-LS 1000024186 85354010 18 SPARES FOR 336KV SURGE ARRESTER LS 1 INCLUDED 0 0 0.00 0.00 0.00
52 Mandatory spares AIS & General-LS 1000053851 76169990 18 SPARES FOR CLAMPS & CONNECTORS LOT 1 INCLUDED 0 0 0.00 0.00 0.00
53 GIS Testing and maintainance equipment 1000025440 85389000 18 SF6 Gas processing Unit for 400kV GIS station SET 1 INCLUDED 0 0 0.00 0.00 0.00
54 GIS Testing and maintainance equipment 1000032132 85389000 18 SF6 GAS ANALYZER EA 1 INCLUDED 0 0 0.00 0.00 0.00
55 GIS Testing and maintainance equipment 1000025436 90271000 18 SF6 Gas Leakage Detector EA 1 INCLUDED 0 0 0.00 0.00 0.00
56 GIS Testing and maintainance equipment 1000025329 90318000 18 Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification. EA 1 INCLUDED 0 0 0.00 0.00 0.00
57 GIS Mandatory spares 1000049795 85359030 18 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
58 GIS Mandatory spares 1000049808 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
59 GIS Mandatory spares 1000049805 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
60 GIS Mandatory spares 1000058321 85359030 18 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
61 GIS Mandatory spares 1000049799 85359030 18 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
62 GIS Mandatory spares 1000058325 85359030 18 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
63 GIS Mandatory spares 1000058318 85359030 18 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
64 GIS Mandatory spares 1000049495 85359030 18 PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 1 INCLUDED 0 0 0.00 0.00 0.00
65 GIS Mandatory spares 1000049802 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
66 GIS Mandatory spares 1000058374 85359030 18 400kV GIS- Single phase of 3150Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 4 INCLUDED 0 0 0.00 0.00 0.00
67 GIS Mandatory spares 1000058314 85359030 18 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 INCLUDED 0 0 0.00 0.00 0.00
68 GIS Mandatory spares 1000058310 85359030 18 400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 INCLUDED 0 0 0.00 0.00 0.00
69 GIS Mandatory spares 1000058305 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
70 GIS Mandatory spares 1000058312 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
71 GIS Mandatory spares 1000058308 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
72 GIS Mandatory spares 1000049776 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
73 GIS Mandatory spares 1000049778 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
74 GIS Mandatory spares 1000058306 85359030 18 DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
75 GIS Mandatory spares 1000058313 85359030 18 DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
76 GIS Mandatory spares 1000058309 85359030 18 DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
77 GIS Mandatory spares 1000058307 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
78 GIS Mandatory spares 1000058315 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
79 GIS Mandatory spares 1000058311 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
80 GIS Mandatory spares 1000058327 85359030 18 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED 0 0 0.00 0.00 0.00
81 GIS Mandatory spares 1000058326 85359030 18 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED 0 0 0.00 0.00 0.00
82 GIS Mandatory spares 1000058332 85359030 18 400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 2 INCLUDED 0 0 0.00 0.00 0.00
83 GIS Mandatory spares 1000049817 85359030 18 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS SET 3 INCLUDED 0 0 0.00 0.00 0.00
84 GIS Mandatory spares 1000049753 85359030 18 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
85 GIS Mandatory spares 1000049762 85359030 18 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS SET 3 INCLUDED 0 0 0.00 0.00 0.00
86 GIS Mandatory spares 1000058330 85359030 18 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED 0 0 0.00 0.00 0.00
87 GIS Mandatory spares 1000049750 85359030 18 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS SET 3 INCLUDED 0 0 0.00 0.00 0.00
88 GIS Mandatory spares 1000058331 85359030 18 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED 0 0 0.00 0.00 0.00
89 GIS Mandatory spares 1000049783 85359030 18 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS SET 3 INCLUDED 0 0 0.00 0.00 0.00
90 GIS Mandatory spares 1000049505 85359030 18 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS EA 5 INCLUDED 0 0 0.00 0.00 0.00
91 GIS Mandatory spares 1000058329 85359030 18 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 INCLUDED 0 0 0.00 0.00 0.00
92 GIS Mandatory spares 1000058333 85359030 18 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0.00 0.00 0.00
93 GIS Mandatory spares 1000032799 85389000 18 420KV, 4000A, 63KA SF6 TO AIR BUSHING SET 1 INCLUDED 0 0 0.00 0.00 0.00
94 GIS Mandatory spares 1000049498 85359030 18 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
95 GIS Mandatory spares 1000058317 85359030 18 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT SET 1 INCLUDED 0 0 0.00 0.00 0.00
96 GIS Mandatory spares 1000058316 85359030 18 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT SET 1 INCLUDED 0 0 0.00 0.00 0.00
97 GIS Mandatory spares 1000021873 85389000 18 Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0.00 0.00 0.00
98 GIS Mandatory spares 1000009208 85389000 18 Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0.00 0.00 0.00
99 GIS Mandatory spares 1000058324 85359030 18 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0.00 0.00 0.00
100 GIS Mandatory spares 1000007067 85389000 18 Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker SET 3 INCLUDED 0 0 0.00 0.00 0.00
101 GIS Mandatory spares 1000058323 85359030 18 400KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 3 INCLUDED 0 0 0.00 0.00 0.00
102 GIS Mandatory spares 1000058320 85359030 18 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
103 GIS Mandatory spares 1000049759 85359030 18 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
104 GIS Mandatory spares 1000058319 85359030 18 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
105 GIS Mandatory spares 1000058322 85359030 18 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
106 GIS Mandatory spares 1000049835 85359030 18 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
107 GIS Mandatory spares 1000049777 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
108 GIS Mandatory spares 1000058334 85359030 18 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 INCLUDED 0 0 0.00 0.00 0.00
109 supply- steel structures 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 90 INCLUDED 0 0 0.00 0.00 0.00
110 supply- steel structures 1000015953 73082011 18 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 27 INCLUDED 0 0 0.00 0.00 0.00
111 supply- steel structures 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 7 INCLUDED 0 0 0.00 0.00 0.00
112 supply- steel structures 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 10 INCLUDED 0 0 0.00 0.00 0.00
113 PMU & associated items (Pandiabili) 1000017518 85364900 18 PMU with GPS Clock (clock can be either internal or external) EA 1 INCLUDED 0 0 0.00 0.00 0.00
114 PMU & associated items (Pandiabili) 1000022512 90311000 18 WAMS Hardware - Time System (GPS receiver) EA 1 INCLUDED 0 0 0.00 0.00 0.00
115 PMU & associated items (Pandiabili) 1000071061 85176290 18 SUBSTATION GRADE LAYER 2 LAN SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
116 PMU & associated items (Pandiabili) 1000071062 85176290 18 SUBSTATION GRADE LAYER 3 LAN SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
117 PMU & associated items (Pandiabili) 1000022487 85447090 18 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 INCLUDED 0 0 0.00 0.00 0.00
118 PMU & associated items (Pandiabili) 1000030641 85389000 18 LIU - FO PATCH PANEL-12 PORT EA 2 INCLUDED 0 0 0.00 0.00 0.00
119 Telecom Eqpt Supply 1000031367 85176260 18 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 INCLUDED 0 0 0.00 0.00 0.00
120 Telecom Eqpt Supply 1000018706 85176990 18 S16.1 SFP EA 4 INCLUDED 0 0 0.00 0.00 0.00
121 Telecom Eqpt Supply 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED 0 0 0.00 0.00 0.00
122 Telecom Eqpt Supply 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED 0 0 0.00 0.00 0.00
123 Telecom Eqpt Supply 1000031381 85176290 18 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
124 Telecom Eqpt Supply 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 INCLUDED 0 0 0.00 0.00 0.00
125 Telecom Eqpt Supply 1000037545 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED 0 0 0.00 0.00 0.00
126 Telecom Eqpt Supply 1000066614 73069011 18 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 1 INCLUDED 0 0 0.00 0.00 0.00
127 Telecom Eqpt Supply 1000066612 73071900 18 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 10 INCLUDED 0 0 0.00 0.00 0.00
128 Telecom Eqpt Supply 1000066613 83071000 18 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 7 INCLUDED 0 0 0.00 0.00 0.00
129 Telecom Eqpt Supply 1000023471 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 INCLUDED 0 0 0.00 0.00 0.00
130 Telecom Eqpt Supply 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED 0 0 0.00 0.00 0.00
131 Telecom Eqpt Supply 1000037546 85447090 18 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED 0 0 0.00 0.00 0.00
132 Telecom Eqpt Spare 1000031369 85176260 18 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED 0 0 0.00 0.00 0.00
133 Telecom Eqpt Spare 1000018706 85176990 18 S16.1 SFP EA 1 INCLUDED 0 0 0.00 0.00 0.00
134 Telecom Eqpt Spare 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
135 Telecom Eqpt Spare 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED 0 0 0.00 0.00 0.00
136 Telecom Eqpt Spare 1000031381 85176290 18 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
137 Telecom Eqpt Spare 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED 0 0 0.00 0.00 0.00
138 Telecom Eqpt Spare 1000031398 85171890 18 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED 0 0 0.00 0.00 0.00
139 Telecom Eqpt Spare 1000066614 73069011 18 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 0.035 INCLUDED 0 0 0.00 0.00 0.00
140 Telecom Eqpt Spare 1000066612 73071900 18 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 4 INCLUDED 0 0 0.00 0.00 0.00
141 Telecom Eqpt Spare 1000066613 83071000 18 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 3 INCLUDED 0 0 0.00 0.00 0.00
142 Telecom Eqpt Spare 1000037546 85447090 18 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED 0 0 0.00 0.00 0.00
Re-tender-NIT-BOQ-Rangpo SS(ERBS-II)
143 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000037223 85389000 18 145KV, 1600, 31.5KA, FOR 1 SEC SF6 GIS BUS BAR EXTENSION MODULE AS PERSECTION-PROJECT, TECHNICAL SPECIFICATION SET 2 INCLUDED 0 0 0.00 0.00 0.00
144 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000000994 85359030 18 145kV, 1250 A, 31.5 kA, SF6 GIS Linefeeder bay module as perSection-Project, Technicalspecification SET 2 INCLUDED 0 0 0.00 0.00 0.00
145 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000032751 85389000 18 145KV, 1250A, 31.5KA,3PH,GIS BUS DUCT M 200 INCLUDED 0 0 0.00 0.00 0.00
146 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000032373 85389000 18 145KV, 1250A, 31.5KA SF6/AIR BUSHING FOR CONNECTING GIS TO AISALONGWITH SUPPORT STRUCTURE SET 6 INCLUDED 0 0 0.00 0.00 0.00
147 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000079181 85049010 18 145KV, 1600A, 31.5KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULESUITABLE FOR EXTENDING EXISTING HYOSUNG MAKE GIS BUS BAR/DUCT AS PERTECHNICAL SPECIFICATION EA 2 INCLUDED 0 0 0.00 0.00 0.00
148 145kV, 31.5kA AIS EQUIPMENT 1000020416 85354010 18 120kV Surge Arrester(1-phase) EA 6 INCLUDED 0 0 0.00 0.00 0.00
149 145kV, 31.5kA AIS EQUIPMENT 1000000956 85462040 18 145kV, 1 phase Bus Post Insulators EA 12 INCLUDED 0 0 0.00 0.00 0.00
150 145kV, 31.5kA AIS EQUIPMENT 1000000991 85359090 18 145 kV, 8800pf, 1-phase Capacitive Voltage Transformer EA 6 INCLUDED 0 0 0.00 0.00 0.00
151 145kV, 31.5kA AIS EQUIPMENT 1000054118 85176210 18 132 KV, 800A, 0.5MH, 31.5KA LINE TRAP EA 2 INCLUDED 0 0 0.00 0.00 0.00
152 Erection HW for 132 kV DM Type 1000011222 85389000 18 Erection Hardware for 132kV DM type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED 0 0 0.00 0.00 0.00
153 CRP for 132 kV Bays with SAS 1000000812 85371000 18 132kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0 0.00 0.00 0.00
154 CRP for 132 kV Bays with SAS 1000055441 85371000 18 132KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 INCLUDED 0 0 0.00 0.00 0.00
155 CRP for 132 kV Bays with SAS 1000000735 85371000 18 Augmentation of existing 132kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED 0 0 0.00 0.00 0.00
156 SAS 1000000815 85371000 18 Augmentation of Substation automation System for 132kV bay as perTechnical Specification EA 2 INCLUDED 0 0 0.00 0.00 0.00
157 PLCC 132kV Rangpo end 1000010014 85176210 18 Coupling device for PLCC SET 1 INCLUDED 0 0 0.00 0.00 0.00
158 PLCC 132kV Rangpo end 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED 0 0 0.00 0.00 0.00
159 PLCC 132kV Rangpo end 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 1 INCLUDED 0 0 0.00 0.00 0.00
160 PLCC 132kV Rangpo end 1000010638 85176210 18 Digital Protection Coupler EA 1 INCLUDED 0 0 0.00 0.00 0.00
161 PLCC 132kV Rangpo end 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0.00 0.00 0.00
162 PLCC 132kV Rangpo end 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 0.5 INCLUDED 0 0 0.00 0.00 0.00
163 PLCC 132kV Rammam end 1000010014 85176210 18 Coupling device for PLCC SET 1 INCLUDED 0 0 0.00 0.00 0.00
164 PLCC 132kV Rammam end 1000000046 85176210 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED 0 0 0.00 0.00 0.00
165 PLCC 132kV Rammam end 1000017887 85176210 18 Analog Protection Coupler for PLCC EA 1 INCLUDED 0 0 0.00 0.00 0.00
166 PLCC 132kV Rammam end 1000010638 85176210 18 Digital Protection Coupler EA 1 INCLUDED 0 0 0.00 0.00 0.00
167 PLCC 132kV Rammam end 1000025769 85176210 18 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED 0 0 0.00 0.00 0.00
168 PLCC 132kV Rammam end 1000036908 85446020 18 HF CABLE 75 OHMS FOR PLCC KM 0.5 INCLUDED 0 0 0.00 0.00 0.00
169 POWER & CONTROL CABLE 1000000443 85446020 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
170 POWER & CONTROL CABLE 1000000442 85446020 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
171 POWER & CONTROL CABLE 1000000444 85446090 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
172 ILLUMINATION SYSTEM 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED 0 0 0.00 0.00 0.00
173 ILLUMINATION SYSTEM 1000004952 94059900 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED 0 0 0.00 0.00 0.00
174 ILLUMINATION SYSTEM 1000038387 94051090 18 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 5 INCLUDED 0 0 0.00 0.00 0.00
175 ILLUMINATION SYSTEM 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 5 INCLUDED 0 0 0.00 0.00 0.00
176 ILLUMINATION SYSTEM 1000049467 94059900 18 INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 INCLUDED 0 0 0.00 0.00 0.00
177 ILLUMINATION SYSTEM 1000014546 94059900 18 Lighting Panel (Indoor) type ACP-1 as per technical specification EA 2 INCLUDED 0 0 0.00 0.00 0.00
178 Spare 132kV Equipment 1000028572 85359090 18 SPARE-145KV CVT LOT 1 INCLUDED 0 0 0.00 0.00 0.00
179 Spare 132kV Equipment 1000026087 85354010 18 Spares for 120kV Surge Arrester LS 1 INCLUDED 0 0 0.00 0.00 0.00
180 Spare 132kV Equipment 1000054421 85462040 18 SPARES FOR 145KV BUS POST INSULATORS SET 1 INCLUDED 0 0 0.00 0.00 0.00
181 Spare Other 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 INCLUDED 0 0 0.00 0.00 0.00
182 Spare Other 1000019927 85389000 18 Spares-Substation Automation System LS 1 INCLUDED 0 0 0.00 0.00 0.00
183 Spare Other 1000053851 76169990 18 SPARES FOR CLAMPS & CONNECTORS LOT 1 INCLUDED 0 0 0.00 0.00 0.00
184 Spare Other 1000025980 85446020 18 Power and Control Cables LS 1 INCLUDED 0 0 0.00 0.00 0.00
185 Spare Other 1000025950 85176210 18 Spare-PLCC SET 1 INCLUDED 0 0 0.00 0.00 0.00
186 Spare Other 1000019925 84819090 18 Spares for Fire Protection System LS 1 INCLUDED 0 0 0.00 0.00 0.00
187 GIS common eqpt 1000032822 85389000 18 EOT CRANE EXTENSION FOR 132KV GIS BUILDING SET 1 INCLUDED 0 0 0.00 0.00 0.00
188 VMS 1000030433 85287390 18 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 INCLUDED 0 0 0.00 0.00 0.00
189 Air conditioning 1000013502 84158210 28 High wall type split AC unit of 2 TR capacity EA 4 INCLUDED 0 0 0.00 0.00 0.00
190 Non Standard Structures 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 20 INCLUDED 0 0 0.00 0.00 0.00
191 Non Standard Structures 1000011713 73082011 18 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2 INCLUDED 0 0 0.00 0.00 0.00
192 Non Standard Structures 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 3 INCLUDED 0 0 0.00 0.00 0.00
193 Spare-GIS 1000058267 85359030 18 145KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED 0 0 0.00 0.00 0.00
194 Spare-GIS 1000050242 85359030 18 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-145KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
195 Spare-GIS 1000050214 85359030 18 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-145KV GIS SET 1 INCLUDED 0 0 0.00 0.00 0.00
196 Spare-GIS 1000050226 85359030 18 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-145KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
197 Spare-GIS 1000058265 85359030 18 145KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED 0 0 0.00 0.00 0.00
198 Spare-GIS 1000050213 85359030 18 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-145KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
199 Spare-GIS 1000058266 85359030 18 145KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED 0 0 0.00 0.00 0.00
200 Spare-GIS 1000050229 85359030 18 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-145KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
201 Spare-GIS 1000050256 85359030 18 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 145KV GIS EA 3 INCLUDED 0 0 0.00 0.00 0.00
202 Spare-GIS 1000058269 85359030 18 145KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0.00 0.00 0.00
203 Spare-GIS 1000058264 85359030 18 145KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0.00 0.00 0.00
204 Spare-GIS 1000058268 85359030 18 145kV GIS- 1250A SF6 to air bushing complete in all respect EA 1 INCLUDED 0 0 0.00 0.00 0.00
205 Spare-GIS 1000050249 85359030 18 LCC SPARES - AUX. RELAYS, CONTACTORS, PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES, TIMERS, TERMINAL BLOCKS ETC.OF EACH TYPE & RATING-145KV GIS SET 1 INCLUDED 0 0 0.00 0.00 0.00
206 Spare-GIS 1000058241 85359030 18 145KV GIS- CIRCUIT BREAKER (THREE PHASE) OF 1250A WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT SET 1 INCLUDED 0 0 0.00 0.00 0.00
207 Spare-GIS 1000021870 85389000 18 Trip coil assembly with resistor (asapplicable) for 145kV GIS CircuitBreaker SET 3 INCLUDED 0 0 0.00 0.00 0.00
208 Spare-GIS 1000009184 85389000 18 Closing coil assembly with resistor (asapplicable) for 145kV GIS CircuitBreaker SET 3 INCLUDED 0 0 0.00 0.00 0.00
209 Spare-GIS 1000058257 85359030 18 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 145KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0.00 0.00 0.00
210 Spare-GIS 1000058244 85359030 18 AUXILIARY SWITCH ASSEMBLY OF EACH TYPE FOR 145KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0.00 0.00 0.00
211 Spare-GIS 1000058251 85359030 18 145KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 1 INCLUDED 0 0 0.00 0.00 0.00
212 Spare-GIS 1000058258 85359030 18 145KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
213 Spare-GIS 1000058369 85359030 18 145kV GIS- Three phase of 1250Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED 0 0 0.00 0.00 0.00
214 Spare-GIS 1000058239 85359030 18 145KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED 0 0 0.00 0.00 0.00
215 Spare-GIS 1000058234 85359030 18 145KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED 0 0 0.00 0.00 0.00
216 Spare-GIS 1000058048 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 145KV GIS DISCONNECTORSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
217 Spare-GIS 1000058236 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 145KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
218 Spare-GIS 1000058231 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 145KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
219 Spare-GIS 1000058260 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR 145KVGIS DISCONNECTOR SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
220 Spare-GIS 1000058238 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR 145KVGIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
221 Spare-GIS 1000058233 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR 145KVGIS FAST EARTHING SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
222 Spare-GIS 1000058049 85359030 18 DRIVE MECHANISM FOR 145KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
223 Spare-GIS 1000058237 85359030 18 DRIVE MECHANISM FOR 145KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
224 Spare-GIS 1000058232 85359030 18 DRIVE MECHANISM FOR 145KV GIS FAST EARTHING SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
225 Spare-GIS 1000058230 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 145KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
226 Spare-GIS 1000058240 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 145KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
227 Spare-GIS 1000058235 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 145KV GIS FAST EARTHING SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
228 Spare-GIS 1000058261 85359030 18 145KV GIS- CURRENT TRANSFORMER (4 CORES) WITH ASSOCIATED ENCLOSURE ANDPRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0.00 0.00 0.00
229 LT Switchgear 1000004304 85371000 18 415V ACDB (Extn.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
230 Telecom Eqpt Supply 1000031367 85176260 18 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 INCLUDED 0 0 0.00 0.00 0.00
231 Telecom Eqpt Supply 1000018706 85176990 18 S16.1 SFP EA 4 INCLUDED 0 0 0.00 0.00 0.00
232 Telecom Eqpt Supply 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED 0 0 0.00 0.00 0.00
233 Telecom Eqpt Supply 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED 0 0 0.00 0.00 0.00
234 Telecom Eqpt Supply 1000031381 85176290 18 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
235 Telecom Eqpt Supply 1000026228 85176290 18 Equipment Cabinets For SDH EA 1 INCLUDED 0 0 0.00 0.00 0.00
236 Telecom Eqpt Supply 1000066614 73069011 18 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 1 INCLUDED 0 0 0.00 0.00 0.00
237 Telecom Eqpt Supply 1000066612 73071900 18 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 10 INCLUDED 0 0 0.00 0.00 0.00
238 Telecom Eqpt Supply 1000066613 83071000 18 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 7 INCLUDED 0 0 0.00 0.00 0.00
239 Telecom Eqpt Supply 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED 0 0 0.00 0.00 0.00
240 Telecom Eqpt Supply 1000023471 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 INCLUDED 0 0 0.00 0.00 0.00
241 Telecom Eqpt Supply 1000037546 85447090 18 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED 0 0 0.00 0.00 0.00
242 Telecom Eqpt Spare 1000031369 85176260 18 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED 0 0 0.00 0.00 0.00
243 Telecom Eqpt Spare 1000018706 85176990 18 S16.1 SFP EA 1 INCLUDED 0 0 0.00 0.00 0.00
244 Telecom Eqpt Spare 1000031374 85176290 18 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
245 Telecom Eqpt Spare 1000034950 85176990 18 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED 0 0 0.00 0.00 0.00
246 Telecom Eqpt Spare 1000031381 85176290 18 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
247 Telecom Eqpt Spare 1000034998 85171890 18 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED 0 0 0.00 0.00 0.00
248 Telecom Eqpt Spare 1000031398 85171890 18 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED 0 0 0.00 0.00 0.00
249 Telecom Eqpt Spare 1000066614 73069011 18 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 0.035 INCLUDED 0 0 0.00 0.00 0.00
250 Telecom Eqpt Spare 1000066612 73071900 18 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 1 INCLUDED 0 0 0.00 0.00 0.00
251 Telecom Eqpt Spare 1000066613 83071000 18 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 1 INCLUDED 0 0 0.00 0.00 0.00
252 Telecom Eqpt Spare 1000037546 85447090 18 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED 0 0 0.00 0.00 0.00
253 Fire Protection System 1000012008 85311020 18 Fire Detection and Alarm System for 132kV GIS Hall SET 1 INCLUDED 0 0 0.00 0.00 0.00
254 Fire Protection System 1000038141 85311020 18 HYDRANT SYSTEM, COMPLETE PIPING ANDACCESSORIES ETC. OUTSIDE THE PUMP HOUSEFOR 132KV SS SET 1 INCLUDED 0 0 0.00 0.00 0.00
255 PMU & associated item Ranpo 1000017518 85364900 18 PMU with GPS Clock (clock can be either internal or external) EA 1 INCLUDED 0 0 0.00 0.00 0.00
256 PMU & associated item Ranpo 1000022512 90311000 18 WAMS Hardware - Time System (GPS receiver) EA 1 INCLUDED 0 0 0.00 0.00 0.00
257 PMU & associated item Ranpo 1000071061 85176290 18 SUBSTATION GRADE LAYER 2 LAN SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
258 PMU & associated item Ranpo 1000071062 85176290 18 SUBSTATION GRADE LAYER 3 LAN SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
259 PMU & associated item Ranpo 1000022487 85447090 18 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 INCLUDED 0 0 0.00 0.00 0.00
260 PMU & associated item Ranpo 1000030641 85389000 18 LIU - FO PATCH PANEL-12 PORT EA 2 INCLUDED 0 0 0.00 0.00 0.00
RETENDER MISA SS NERES-XXVIII 0 0 0.00 0.00 0.00
261 GIS PORTION 420kV GIS eqpts 1000032796 85389000 18 420KV, 3150A, 63KA SF6 TO AIR BUSHING including support structure SET 3 INCLUDED 0 0 0.00 0.00 0.00
262 GIS PORTION 420kV GIS eqpts 1000059207 85359030 18 420KV, 3000A, 63KA, SINGLE PHASE, SF6 GAS INSULATED BUS DUCT (GIB)OUTSIDE GIS HALL ALONGWITH ASSOCIATED SUPPORT STRUCTURE, ETC. AS PERTECHNICAL SPECIFICATION M 450 INCLUDED 0 0 0.00 0.00 0.00
263 GIS PORTION 420kV GIS eqpts 1000032802 85359030 18 420KV, 4000A,63KA GIS BUSBAR MODULE EXTENSION SET 2 INCLUDED 0 0 0.00 0.00 0.00
264 GIS PORTION 420kV GIS eqpts 1000009713 85389000 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 2 INCLUDED 0 0 0.00 0.00 0.00
265 GIS PORTION 420kV GIS eqpts 1000004632 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS BusReactor bay module as perSection-Project, Technicalspecification SET 1 INCLUDED 0 0 0.00 0.00 0.00
266 GIS PORTION 420kV GIS eqpts 1000004505 85359030 18 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 1 INCLUDED 0 0 0.00 0.00 0.00
267 GIS PORTION 420kV GIS eqpts 1000077607 85359030 18 420KV,4000A, 63KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULESUITABLE FOR EXTENDING EXISTING HITACHI MAKE GIS BUS BAR/DUCT AS PERTECHNICAL SPECIFICATION SET 2 INCLUDED 0 0 0.00 0.00 0.00
268 AIS equipments 1000020419 85354010 18 336kV Surge Arrester (1-phase) EA 3 INCLUDED 0 0 0.00 0.00 0.00
269 AIS equipments 1000004401 85462040 18 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED 0 0 0.00 0.00 0.00
270 RELAY & PROTECTION PANEL 1000055446 85371000 18 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 INCLUDED 0 0 0.00 0.00 0.00
271 RELAY & PROTECTION PANEL 1000002146 85371000 18 Augmentation of existing 400kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED 0 0 0.00 0.00 0.00
272 RELAY & PROTECTION PANEL 1000003407 85371000 18 400kV Reactor Protection Panel (with Automation) EA 1 INCLUDED 0 0 0.00 0.00 0.00
273 SAS augmenttaion 1000003409 85371000 18 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 1 INCLUDED 0 0 0.00 0.00 0.00
274 SAS augmenttaion 1000003411 85371000 18 Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 1 INCLUDED 0 0 0.00 0.00 0.00
275 420kV Erection harware 1000011329 72169990 18 Erection Hardware for 400kV DM type layout for GIS terminationarrangement-Bus Reactor bay as per technical specification SET 1 INCLUDED 0 0 0.00 0.00 0.00
276 ventilation system 1000022409 84159000 28 Ventillation system for 400kV GIS Hall Ext SET 1 INCLUDED 0 0 0.00 0.00 0.00
277 power & control cable 1000000442 85446020 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
278 power & control cable 1000000443 85446020 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
279 power & control cable 1000000444 85446090 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0 0.00 0.00 0.00
280 Illumination (indoor) 1000049467 94059900 18 INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 INCLUDED 0 0 0.00 0.00 0.00
281 outdoor illumination 1000014547 85371000 18 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED 0 0 0.00 0.00 0.00
282 outdoor illumination 1000038325 94059900 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED 0 0 0.00 0.00 0.00
283 outdoor illumination 1000038039 94051090 18 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED 0 0 0.00 0.00 0.00
284 outdoor illumination 1000004952 94059900 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED 0 0 0.00 0.00 0.00
285 outdoor illumination 1000001894 94059900 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0 0.00 0.00 0.00
286 outdoor illumination 1000038385 94059900 18 FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 4 INCLUDED 0 0 0.00 0.00 0.00
287 LT swgr extension 1000004304 85371000 18 415V ACDB (Extn.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
288 LT swgr extension 1000001145 85371000 18 220V DCDB (Extn.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
289 LT swgr extension 1000004309 85371000 18 415V MLDB (Extn.) SET 1 INCLUDED 0 0 0.00 0.00 0.00
290 fire protection system 1000012022 84241000 18 4.5 kg CO2 type Portable Fire extinguisher EA 2 INCLUDED 0 0 0.00 0.00 0.00
291 fire protection system 1000012026 84241000 18 6Kg dry chemical powered type Portable Fire extinguisher EA 2 INCLUDED 0 0 0.00 0.00 0.00
292 fire protection system 1000055457 84248990 18 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 420KV 3 PHASE BUSREACTOR SET 1 INCLUDED 0 0 0.00 0.00 0.00
293 fire protection system 1000012010 85311020 18 Fire Detection and Alarm System for 400kV GIS Hall SET 1 INCLUDED 0 0 0.00 0.00 0.00
294 fire protection system 1000012037 84819090 18 Hydrant system, complete U/G piping and accessories etc. outside thePump House for Fire Protection of 400/220kV (Ext) Substation SET 1 INCLUDED 0 0 0.00 0.00 0.00
295 earthmat 1000032055 72159090 18 40 MM MS ROD FOR MAIN EARTHMAT KM 1 INCLUDED 0 0 0.00 0.00 0.00
296 mandatory spares 1000024186 85354010 18 SPARES FOR 336KV SURGE ARRESTER LS 1 INCLUDED 0 0 0.00 0.00 0.00
297 mandatory spares 1000025940 85462040 18 Spare-420kV BPI SET 1 INCLUDED 0 0 0.00 0.00 0.00
298 mandatory spares 1000019912 85371000 18 Relay & protection Panels (with automation) LS 1 INCLUDED 0 0 0.00 0.00 0.00
299 mandatory spares 1000019927 85389000 18 Spares-Substation Automation System LS 1 INCLUDED 0 0 0.00 0.00 0.00
300 mandatory spares 1000019925 84819090 18 Spares for Fire Protection System LS 1 INCLUDED 0 0 0.00 0.00 0.00
301 GIS PORTION -MANDATORY SPARES 1000058332 85359030 18 400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED 0 0 0.00 0.00 0.00
302 GIS PORTION -MANDATORY SPARES 1000049817 85359030 18 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
303 GIS PORTION -MANDATORY SPARES 1000049753 85359030 18 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS SET 1 INCLUDED 0 0 0.00 0.00 0.00
304 GIS PORTION -MANDATORY SPARES 1000049762 85359030 18 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
305 GIS PORTION -MANDATORY SPARES 1000058330 85359030 18 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED 0 0 0.00 0.00 0.00
306 GIS PORTION -MANDATORY SPARES 1000049750 85359030 18 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
307 GIS PORTION -MANDATORY SPARES 1000058331 85359030 18 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED 0 0 0.00 0.00 0.00
308 GIS PORTION -MANDATORY SPARES 1000049783 85359030 18 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS SET 2 INCLUDED 0 0 0.00 0.00 0.00
309 GIS PORTION -MANDATORY SPARES 1000049505 85359030 18 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS EA 3 INCLUDED 0 0 0.00 0.00 0.00
310 GIS PORTION -MANDATORY SPARES 1000058334 85359030 18 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0.00 0.00 0.00
311 GIS PORTION -MANDATORY SPARES 1000058329 85359030 18 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED 0 0 0.00 0.00 0.00
312 GIS PORTION -MANDATORY SPARES 1000058333 85359030 18 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED 0 0 0.00 0.00 0.00
313 GIS PORTION -MANDATORY SPARES 1000049498 85359030 18 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS SET 1 INCLUDED 0 0 0.00 0.00 0.00
314 GIS PORTION -MANDATORY SPARES 1000058317 85359030 18 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT SET 1 INCLUDED 0 0 0.00 0.00 0.00
315 GIS PORTION -MANDATORY SPARES 1000021873 85389000 18 Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0.00 0.00 0.00
316 GIS PORTION -MANDATORY SPARES 1000009208 85389000 18 Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED 0 0 0.00 0.00 0.00
317 GIS PORTION -MANDATORY SPARES 1000058324 85359030 18 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER SET 1 INCLUDED 0 0 0.00 0.00 0.00
318 GIS PORTION -MANDATORY SPARES 1000007067 85389000 18 Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker SET 1 INCLUDED 0 0 0.00 0.00 0.00
319 GIS PORTION -MANDATORY SPARES 1000058320 85359030 18 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
320 GIS PORTION -MANDATORY SPARES 1000049759 85359030 18 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
321 GIS PORTION -MANDATORY SPARES 1000058319 85359030 18 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
322 GIS PORTION -MANDATORY SPARES 1000058322 85359030 18 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
323 GIS PORTION -MANDATORY SPARES 1000049835 85359030 18 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
324 GIS PORTION -MANDATORY SPARES 1000049795 85359030 18 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
325 GIS PORTION -MANDATORY SPARES 1000049808 85359030 18 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
326 GIS PORTION -MANDATORY SPARES 1000049805 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
327 GIS PORTION -MANDATORY SPARES 1000058321 85359030 18 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
328 GIS PORTION -MANDATORY SPARES 1000049799 85359030 18 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
329 GIS PORTION -MANDATORY SPARES 1000058325 85359030 18 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
330 GIS PORTION -MANDATORY SPARES 1000058318 85359030 18 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED 0 0 0.00 0.00 0.00
331 GIS PORTION -MANDATORY SPARES 1000049495 85359030 18 PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 1 INCLUDED 0 0 0.00 0.00 0.00
332 GIS PORTION -MANDATORY SPARES 1000049802 85359030 18 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED 0 0 0.00 0.00 0.00
333 GIS PORTION -MANDATORY SPARES 1000058374 85359030 18 400kV GIS- Single phase of 3150Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED 0 0 0.00 0.00 0.00
334 GIS PORTION -MANDATORY SPARES 1000058314 85359030 18 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED 0 0 0.00 0.00 0.00
335 GIS PORTION -MANDATORY SPARES 1000058305 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
336 GIS PORTION -MANDATORY SPARES 1000058312 85359030 18 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
337 GIS PORTION -MANDATORY SPARES 1000049776 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS SET 1 INCLUDED 0 0 0.00 0.00 0.00
338 GIS PORTION -MANDATORY SPARES 1000049778 85359030 18 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS SET 1 INCLUDED 0 0 0.00 0.00 0.00
339 GIS PORTION -MANDATORY SPARES 1000058306 85359030 18 DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
340 GIS PORTION -MANDATORY SPARES 1000058313 85359030 18 DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED 0 0 0.00 0.00 0.00
341 GIS PORTION -MANDATORY SPARES 1000058307 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
342 GIS PORTION -MANDATORY SPARES 1000058315 85359030 18 MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED 0 0 0.00 0.00 0.00
343 GIS PORTION -MANDATORY SPARES 1000058327 85359030 18 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED 0 0 0.00 0.00 0.00
344 GIS PORTION -MANDATORY SPARES 1000058326 85359030 18 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED 0 0 0.00 0.00 0.00
345 supply of foundation bolt 1000012367 73082011 18 Fabrication, galvanising and supply of 32mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 36 INCLUDED 0 0 0.00 0.00 0.00
346 Supply of structure 1000020195 73045930 18 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED 0 0 0.00 0.00 0.00
347 Supply of structure 1000020196 73045930 18 Fabrication, galvanising and supply ofStd Pipe Structure - 400 kV, 1-Phase,BPI, (Excluding Wave Trap), includingnuts, bolts, all type of washers,packplates, step bolts and gussetplates excluding foundation bolts EA 6 INCLUDED 0 0 0.00 0.00 0.00
348 Supply of structure 1000015952 73082011 18 Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 5 INCLUDED 0 0 0.00 0.00 0.00
349 Supply of structure 1000012373 73082011 18 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 1 INCLUDED 0 0 0.00 0.00 0.00
Total Ex-Works Price 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-Works Price including Type Test charges 0.00
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 2
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(SCHEDULE OF RATES AND PRICES)
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address: "Saudamini", Plot No.-2
Gurugram (Haryana) - 122001
Local Transportation, In-transit Insurance, Loading and Unloading
(All Prices are in Indian Rupees)
SI. No. Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & Unloading Charges Total Freight, In-transit Insurance, loading & Unloading Charges
Re-tender-NIT-BOQ-Pandiabil SS (ERBS-I)
1 AIS EQUIPMENT 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED
2 AIS EQUIPMENT 1000020419 336kV Surge Arrester (1-phase) EA 6 INCLUDED
3 AIS EQUIPMENT 1000004535 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 INCLUDED
4 AIS EQUIPMENT 1000000004 400kV,3150A,1.0mH ,63kA Line Trap EA 4 INCLUDED
5 AIS EQUIPMENT 1000004400 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 INCLUDED
6 400KV GIS EQUIPMENT 1000004287 420kV, 3000A, 63kA, Single phase, SF6Gas Insulated Bus Duct (GIB) outsideGIS Hall alongwith associated supportstructure M 600 INCLUDED
7 400KV GIS EQUIPMENT 1000032699 3150A, 63KA, 1SEC SINGLE PHASE 420KV SF6 TO AIR BUSHING EA 6 INCLUDED
8 400KV GIS EQUIPMENT 1000032802 420KV, 4000A,63KA GIS BUSBAR MODULE EXTENSION SET 2 INCLUDED
9 400KV GIS EQUIPMENT 1000004364 Single phase/3-phase 420kV GIS earthing switch of including maincircuit, enclosure, driving mechanism. SET 1 INCLUDED
10 400KV GIS EQUIPMENT 1000004638 420 kV, 3150 A, 63 kA, SF6 GIS Linefeeder bay module(without PIR) as perSection-Project, Technicalspecification SET 1 INCLUDED
11 400KV GIS EQUIPMENT 1000004505 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 1 INCLUDED
12 400KV GIS EQUIPMENT 1000004637 420kV, 3150 A, 63 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 1 INCLUDED
13 400KV GIS EQUIPMENT 1000009713 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 3 INCLUDED
14 400KV GIS EQUIPMENT 1000077608 420KV,4000A, 63KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULESUITABLE FOR EXTENDING EXISTING HYOSUNG MAKE GIS BUS BAR/DUCT AS PERTECHNICAL SPECIFICATION SET 2 INCLUDED
15 CRP 1000055446 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 3 INCLUDED
16 CRP 1000025391 Relay Test kit EA 1 INCLUDED
17 CRP 1000003398 400kV Line Protection Panel (with Automation) EA 2 INCLUDED
18 AUG-SAS 1000003409 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 3 INCLUDED
19 AUG-SAS 1000003411 Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 1 INCLUDED
20 ERECTION HARDWARE & INSULATOR 1000011336 Erection Hardware for 400kV I type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED
21 ILLUMINATION 1000014547 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED
22 ILLUMINATION 1000014546 Lighting Panel (Indoor) type ACP-1 as per technical specification EA 1 INCLUDED
23 ILLUMINATION 1000004795 5/15 A, 240V: Indoor Receptacle 3-pin type modular (type RI) as pertechnical specifications EA 1 INCLUDED
24 ILLUMINATION 1000001050 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 1 INCLUDED
25 ILLUMINATION 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED
26 ILLUMINATION 1000038039 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED
27 ILLUMINATION 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 2 INCLUDED
28 VMS 1000030433 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 INCLUDED
29 LT SWITCHGEAR 1000004304 415V ACDB (Extn.) SET 1 INCLUDED
30 PLCC Equipment at Pandiabili end 1000010014 Coupling device for PLCC SET 2 INCLUDED
31 PLCC Equipment at Pandiabili end 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED
32 PLCC Equipment at Pandiabili end 1000017887 Analog Protection Coupler for PLCC EA 2 INCLUDED
33 PLCC Equipment at Pandiabili end 1000010638 Digital Protection Coupler EA 2 INCLUDED
34 PLCC Equipment at Pandiabili end 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
35 PLCC Equipment at Pandiabili end 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED
36 PLCC Equipment at Pandiabili end 1000001104 2wire telephone equipment EA 1 INCLUDED
37 PLCC Equipment at Talchar end 1000010014 Coupling device for PLCC SET 2 INCLUDED
38 PLCC Equipment at Talchar end 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 INCLUDED
39 PLCC Equipment at Talchar end 1000017887 Analog Protection Coupler for PLCC EA 2 INCLUDED
40 PLCC Equipment at Talchar end 1000010638 Digital Protection Coupler EA 2 INCLUDED
41 PLCC Equipment at Talchar end 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
42 PLCC Equipment at Talchar end 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 INCLUDED
43 PLCC Equipment at Talchar end 1000001104 2wire telephone equipment EA 1 INCLUDED
44 Power&Control Cable (LS) 1000000443 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
45 Power&Control Cable (LS) 1000000442 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
46 Power&Control Cable (LS) 1000000444 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
47 Mandatory spares AIS & General-LS 1000025943 Spare-420kV CVT 1 SET 1 INCLUDED
48 Mandatory spares AIS & General-LS 1000025940 Spare-420kV BPI SET 1 INCLUDED
49 Mandatory spares AIS & General-LS 1000019927 Spares-Substation Automation System LS 1 INCLUDED
50 Mandatory spares AIS & General-LS 1000019912 Relay & protection Panels (with automation) LS 1 INCLUDED
51 Mandatory spares AIS & General-LS 1000024186 SPARES FOR 336KV SURGE ARRESTER LS 1 INCLUDED
52 Mandatory spares AIS & General-LS 1000053851 SPARES FOR CLAMPS & CONNECTORS LOT 1 INCLUDED
53 GIS Testing and maintainance equipment 1000025440 SF6 Gas processing Unit for 400kV GIS station SET 1 INCLUDED
54 GIS Testing and maintainance equipment 1000032132 SF6 GAS ANALYZER EA 1 INCLUDED
55 GIS Testing and maintainance equipment 1000025436 SF6 Gas Leakage Detector EA 1 INCLUDED
56 GIS Testing and maintainance equipment 1000025329 Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification. EA 1 INCLUDED
57 GIS Mandatory spares 1000049795 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
58 GIS Mandatory spares 1000049808 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
59 GIS Mandatory spares 1000049805 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
60 GIS Mandatory spares 1000058321 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
61 GIS Mandatory spares 1000049799 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
62 GIS Mandatory spares 1000058325 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED
63 GIS Mandatory spares 1000058318 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
64 GIS Mandatory spares 1000049495 PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 1 INCLUDED
65 GIS Mandatory spares 1000049802 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
66 GIS Mandatory spares 1000058374 400kV GIS- Single phase of 3150Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 4 INCLUDED
67 GIS Mandatory spares 1000058314 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 INCLUDED
68 GIS Mandatory spares 1000058310 400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 2 INCLUDED
69 GIS Mandatory spares 1000058305 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH SET 1 INCLUDED
70 GIS Mandatory spares 1000058312 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED
71 GIS Mandatory spares 1000058308 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED
72 GIS Mandatory spares 1000049776 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS SET 2 INCLUDED
73 GIS Mandatory spares 1000049778 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS SET 2 INCLUDED
74 GIS Mandatory spares 1000058306 DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED
75 GIS Mandatory spares 1000058313 DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED
76 GIS Mandatory spares 1000058309 DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH SET 1 INCLUDED
77 GIS Mandatory spares 1000058307 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED
78 GIS Mandatory spares 1000058315 MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED
79 GIS Mandatory spares 1000058311 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH EA 1 INCLUDED
80 GIS Mandatory spares 1000058327 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED
81 GIS Mandatory spares 1000058326 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED
82 GIS Mandatory spares 1000058332 400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 2 INCLUDED
83 GIS Mandatory spares 1000049817 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS SET 3 INCLUDED
84 GIS Mandatory spares 1000049753 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS SET 2 INCLUDED
85 GIS Mandatory spares 1000049762 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS SET 3 INCLUDED
86 GIS Mandatory spares 1000058330 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED
87 GIS Mandatory spares 1000049750 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS SET 3 INCLUDED
88 GIS Mandatory spares 1000058331 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED
89 GIS Mandatory spares 1000049783 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS SET 3 INCLUDED
90 GIS Mandatory spares 1000049505 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS EA 5 INCLUDED
91 GIS Mandatory spares 1000058329 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 INCLUDED
92 GIS Mandatory spares 1000058333 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED
93 GIS Mandatory spares 1000032799 420KV, 4000A, 63KA SF6 TO AIR BUSHING SET 1 INCLUDED
94 GIS Mandatory spares 1000049498 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS SET 2 INCLUDED
95 GIS Mandatory spares 1000058317 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT SET 1 INCLUDED
96 GIS Mandatory spares 1000058316 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT SET 1 INCLUDED
97 GIS Mandatory spares 1000021873 Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
98 GIS Mandatory spares 1000009208 Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
99 GIS Mandatory spares 1000058324 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER SET 1 INCLUDED
100 GIS Mandatory spares 1000007067 Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker SET 3 INCLUDED
101 GIS Mandatory spares 1000058323 400KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 3 INCLUDED
102 GIS Mandatory spares 1000058320 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
103 GIS Mandatory spares 1000049759 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
104 GIS Mandatory spares 1000058319 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
105 GIS Mandatory spares 1000058322 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED
106 GIS Mandatory spares 1000049835 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
107 GIS Mandatory spares 1000049777 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS SET 2 INCLUDED
108 GIS Mandatory spares 1000058334 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 5 INCLUDED
109 supply- steel structures 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 90 INCLUDED
110 supply- steel structures 1000015953 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 27 INCLUDED
111 supply- steel structures 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 7 INCLUDED
112 supply- steel structures 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 10 INCLUDED
113 PMU & associated items (Pandiabili) 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 1 INCLUDED
114 PMU & associated items (Pandiabili) 1000022512 WAMS Hardware - Time System (GPS receiver) EA 1 INCLUDED
115 PMU & associated items (Pandiabili) 1000071061 SUBSTATION GRADE LAYER 2 LAN SWITCH EA 1 INCLUDED
116 PMU & associated items (Pandiabili) 1000071062 SUBSTATION GRADE LAYER 3 LAN SWITCH EA 1 INCLUDED
117 PMU & associated items (Pandiabili) 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 INCLUDED
118 PMU & associated items (Pandiabili) 1000030641 LIU - FO PATCH PANEL-12 PORT EA 2 INCLUDED
119 Telecom Eqpt Supply 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 INCLUDED
120 Telecom Eqpt Supply 1000018706 S16.1 SFP EA 4 INCLUDED
121 Telecom Eqpt Supply 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED
122 Telecom Eqpt Supply 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED
123 Telecom Eqpt Supply 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED
124 Telecom Eqpt Supply 1000026228 Equipment Cabinets For SDH EA 1 INCLUDED
125 Telecom Eqpt Supply 1000037545 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED
126 Telecom Eqpt Supply 1000066614 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 1 INCLUDED
127 Telecom Eqpt Supply 1000066612 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 10 INCLUDED
128 Telecom Eqpt Supply 1000066613 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 7 INCLUDED
129 Telecom Eqpt Supply 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 INCLUDED
130 Telecom Eqpt Supply 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED
131 Telecom Eqpt Supply 1000037546 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED
132 Telecom Eqpt Spare 1000031369 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED
133 Telecom Eqpt Spare 1000018706 S16.1 SFP EA 1 INCLUDED
134 Telecom Eqpt Spare 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED
135 Telecom Eqpt Spare 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED
136 Telecom Eqpt Spare 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED
137 Telecom Eqpt Spare 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED
138 Telecom Eqpt Spare 1000031398 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED
139 Telecom Eqpt Spare 1000066614 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 0.035 INCLUDED
140 Telecom Eqpt Spare 1000066612 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 4 INCLUDED
141 Telecom Eqpt Spare 1000066613 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 3 INCLUDED
142 Telecom Eqpt Spare 1000037546 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED
Re-tender-NIT-BOQ-Rangpo SS(ERBS-II)
143 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000037223 145KV, 1600, 31.5KA, FOR 1 SEC SF6 GIS BUS BAR EXTENSION MODULE AS PERSECTION-PROJECT, TECHNICAL SPECIFICATION SET 2 INCLUDED
144 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000000994 145kV, 1250 A, 31.5 kA, SF6 GIS Linefeeder bay module as perSection-Project, Technicalspecification SET 2 INCLUDED
145 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000032751 145KV, 1250A, 31.5KA,3PH,GIS BUS DUCT M 200 INCLUDED
146 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000032373 145KV, 1250A, 31.5KA SF6/AIR BUSHING FOR CONNECTING GIS TO AISALONGWITH SUPPORT STRUCTURE SET 6 INCLUDED
147 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 1000079181 145KV, 1600A, 31.5KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULESUITABLE FOR EXTENDING EXISTING HYOSUNG MAKE GIS BUS BAR/DUCT AS PERTECHNICAL SPECIFICATION EA 2 INCLUDED
148 145kV, 31.5kA AIS EQUIPMENT 1000020416 120kV Surge Arrester(1-phase) EA 6 INCLUDED
149 145kV, 31.5kA AIS EQUIPMENT 1000000956 145kV, 1 phase Bus Post Insulators EA 12 INCLUDED
150 145kV, 31.5kA AIS EQUIPMENT 1000000991 145 kV, 8800pf, 1-phase Capacitive Voltage Transformer EA 6 INCLUDED
151 145kV, 31.5kA AIS EQUIPMENT 1000054118 132 KV, 800A, 0.5MH, 31.5KA LINE TRAP EA 2 INCLUDED
152 Erection HW for 132 kV DM Type 1000011222 Erection Hardware for 132kV DM type layout for GIS terminationarrangement-Line bay as per technical specification SET 2 INCLUDED
153 CRP for 132 kV Bays with SAS 1000000812 132kV Line Protection Panel (with Automation) EA 2 INCLUDED
154 CRP for 132 kV Bays with SAS 1000055441 132KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 INCLUDED
155 CRP for 132 kV Bays with SAS 1000000735 Augmentation of existing 132kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED
156 SAS 1000000815 Augmentation of Substation automation System for 132kV bay as perTechnical Specification EA 2 INCLUDED
157 PLCC 132kV Rangpo end 1000010014 Coupling device for PLCC SET 1 INCLUDED
158 PLCC 132kV Rangpo end 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED
159 PLCC 132kV Rangpo end 1000017887 Analog Protection Coupler for PLCC EA 1 INCLUDED
160 PLCC 132kV Rangpo end 1000010638 Digital Protection Coupler EA 1 INCLUDED
161 PLCC 132kV Rangpo end 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
162 PLCC 132kV Rangpo end 1000036908 HF CABLE 75 OHMS FOR PLCC KM 0.5 INCLUDED
163 PLCC 132kV Rammam end 1000010014 Coupling device for PLCC SET 1 INCLUDED
164 PLCC 132kV Rammam end 1000000046 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED
165 PLCC 132kV Rammam end 1000017887 Analog Protection Coupler for PLCC EA 1 INCLUDED
166 PLCC 132kV Rammam end 1000010638 Digital Protection Coupler EA 1 INCLUDED
167 PLCC 132kV Rammam end 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 INCLUDED
168 PLCC 132kV Rammam end 1000036908 HF CABLE 75 OHMS FOR PLCC KM 0.5 INCLUDED
169 POWER & CONTROL CABLE 1000000443 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
170 POWER & CONTROL CABLE 1000000442 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
171 POWER & CONTROL CABLE 1000000444 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
172 ILLUMINATION SYSTEM 1000014547 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED
173 ILLUMINATION SYSTEM 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED
174 ILLUMINATION SYSTEM 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 5 INCLUDED
175 ILLUMINATION SYSTEM 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 5 INCLUDED
176 ILLUMINATION SYSTEM 1000049467 INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 INCLUDED
177 ILLUMINATION SYSTEM 1000014546 Lighting Panel (Indoor) type ACP-1 as per technical specification EA 2 INCLUDED
178 Spare 132kV Equipment 1000028572 SPARE-145KV CVT LOT 1 INCLUDED
179 Spare 132kV Equipment 1000026087 Spares for 120kV Surge Arrester LS 1 INCLUDED
180 Spare 132kV Equipment 1000054421 SPARES FOR 145KV BUS POST INSULATORS SET 1 INCLUDED
181 Spare Other 1000019912 Relay & protection Panels (with automation) LS 1 INCLUDED
182 Spare Other 1000019927 Spares-Substation Automation System LS 1 INCLUDED
183 Spare Other 1000053851 SPARES FOR CLAMPS & CONNECTORS LOT 1 INCLUDED
184 Spare Other 1000025980 Power and Control Cables LS 1 INCLUDED
185 Spare Other 1000025950 Spare-PLCC SET 1 INCLUDED
186 Spare Other 1000019925 Spares for Fire Protection System LS 1 INCLUDED
187 GIS common eqpt 1000032822 EOT CRANE EXTENSION FOR 132KV GIS BUILDING SET 1 INCLUDED
188 VMS 1000030433 COLOR IP CAMERA, WITH PAN, TILT AND ZOOM FACILITIES, ALONGWITH ALLREQUIRED ITEMS, ACCESSORIES, LINE INTERFACE UNITS, FIBER PATCH CORDS,POWER SUPPLY UNITS, JUNCTION BOXES, CABLES, FIBER OPTIC CABLES, ETC.,AND INCLUDING INTEGRATION IN EXISTING HARDWARE AND SOFTWARE FORAUGMENTATION OF VISUAL MONITORING SYSTEM AS PER TECHNICALSPECIFICATION. SET 1 INCLUDED
189 Air conditioning 1000013502 High wall type split AC unit of 2 TR capacity EA 4 INCLUDED
190 Non Standard Structures 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 20 INCLUDED
191 Non Standard Structures 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 2 INCLUDED
192 Non Standard Structures 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 3 INCLUDED
193 Spare-GIS 1000058267 145KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED
194 Spare-GIS 1000050242 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-145KV GIS SET 2 INCLUDED
195 Spare-GIS 1000050214 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-145KV GIS SET 1 INCLUDED
196 Spare-GIS 1000050226 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-145KV GIS SET 2 INCLUDED
197 Spare-GIS 1000058265 145KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED
198 Spare-GIS 1000050213 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-145KV GIS SET 2 INCLUDED
199 Spare-GIS 1000058266 145KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED
200 Spare-GIS 1000050229 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPENPOSITION IN CASE OF REMOVAL OF THE DRIVING MECHANISM-145KV GIS SET 2 INCLUDED
201 Spare-GIS 1000050256 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 145KV GIS EA 3 INCLUDED
202 Spare-GIS 1000058269 145KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
203 Spare-GIS 1000058264 145KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
204 Spare-GIS 1000058268 145kV GIS- 1250A SF6 to air bushing complete in all respect EA 1 INCLUDED
205 Spare-GIS 1000050249 LCC SPARES - AUX. RELAYS, CONTACTORS, PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES, TIMERS, TERMINAL BLOCKS ETC.OF EACH TYPE & RATING-145KV GIS SET 1 INCLUDED
206 Spare-GIS 1000058241 145KV GIS- CIRCUIT BREAKER (THREE PHASE) OF 1250A WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT SET 1 INCLUDED
207 Spare-GIS 1000021870 Trip coil assembly with resistor (asapplicable) for 145kV GIS CircuitBreaker SET 3 INCLUDED
208 Spare-GIS 1000009184 Closing coil assembly with resistor (asapplicable) for 145kV GIS CircuitBreaker SET 3 INCLUDED
209 Spare-GIS 1000058257 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 145KV GIS CIRCUIT BREAKER SET 1 INCLUDED
210 Spare-GIS 1000058244 AUXILIARY SWITCH ASSEMBLY OF EACH TYPE FOR 145KV GIS CIRCUIT BREAKER SET 1 INCLUDED
211 Spare-GIS 1000058251 145KV GIS CIRCUIT BREAKER-OPERATION COUNTER EA 1 INCLUDED
212 Spare-GIS 1000058258 145KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED
213 Spare-GIS 1000058369 145kV GIS- Three phase of 1250Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED
214 Spare-GIS 1000058239 145KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED
215 Spare-GIS 1000058234 145KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) & EARTHSWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMON OPERATINGMECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR & EARTH SWITCHIN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TO BE PROVIDEDUNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - IN CASE,DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN A SAMEENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED
216 Spare-GIS 1000058048 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 145KV GIS DISCONNECTORSWITCH SET 1 INCLUDED
217 Spare-GIS 1000058236 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 145KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED
218 Spare-GIS 1000058231 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 145KV GIS FAST EARTHINGSWITCH SET 1 INCLUDED
219 Spare-GIS 1000058260 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR 145KVGIS DISCONNECTOR SWITCH SET 1 INCLUDED
220 Spare-GIS 1000058238 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR 145KVGIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED
221 Spare-GIS 1000058233 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR 145KVGIS FAST EARTHING SWITCH SET 1 INCLUDED
222 Spare-GIS 1000058049 DRIVE MECHANISM FOR 145KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED
223 Spare-GIS 1000058237 DRIVE MECHANISM FOR 145KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED
224 Spare-GIS 1000058232 DRIVE MECHANISM FOR 145KV GIS FAST EARTHING SWITCH SET 1 INCLUDED
225 Spare-GIS 1000058230 MOTOR FOR DRIVE MECHANISM FOR 145KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED
226 Spare-GIS 1000058240 MOTOR FOR DRIVE MECHANISM FOR 145KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED
227 Spare-GIS 1000058235 MOTOR FOR DRIVE MECHANISM FOR 145KV GIS FAST EARTHING SWITCH EA 1 INCLUDED
228 Spare-GIS 1000058261 145KV GIS- CURRENT TRANSFORMER (4 CORES) WITH ASSOCIATED ENCLOSURE ANDPRIMARY CONDUCTOR COMPLETE IN ALL RESPECT EA 1 INCLUDED
229 LT Switchgear 1000004304 415V ACDB (Extn.) SET 1 INCLUDED
230 Telecom Eqpt Supply 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 INCLUDED
231 Telecom Eqpt Supply 1000018706 S16.1 SFP EA 4 INCLUDED
232 Telecom Eqpt Supply 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 INCLUDED
233 Telecom Eqpt Supply 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 INCLUDED
234 Telecom Eqpt Supply 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED
235 Telecom Eqpt Supply 1000026228 Equipment Cabinets For SDH EA 1 INCLUDED
236 Telecom Eqpt Supply 1000066614 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 1 INCLUDED
237 Telecom Eqpt Supply 1000066612 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 10 INCLUDED
238 Telecom Eqpt Supply 1000066613 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 7 INCLUDED
239 Telecom Eqpt Supply 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 INCLUDED
240 Telecom Eqpt Supply 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 INCLUDED
241 Telecom Eqpt Supply 1000037546 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 1 INCLUDED
242 Telecom Eqpt Spare 1000031369 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 INCLUDED
243 Telecom Eqpt Spare 1000018706 S16.1 SFP EA 1 INCLUDED
244 Telecom Eqpt Spare 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 INCLUDED
245 Telecom Eqpt Spare 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 INCLUDED
246 Telecom Eqpt Spare 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 INCLUDED
247 Telecom Eqpt Spare 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 INCLUDED
248 Telecom Eqpt Spare 1000031398 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 INCLUDED
249 Telecom Eqpt Spare 1000066614 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 0.035 INCLUDED
250 Telecom Eqpt Spare 1000066612 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 1 INCLUDED
251 Telecom Eqpt Spare 1000066613 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 1 INCLUDED
252 Telecom Eqpt Spare 1000037546 48F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 INCLUDED
253 Fire Protection System 1000012008 Fire Detection and Alarm System for 132kV GIS Hall SET 1 INCLUDED
254 Fire Protection System 1000038141 HYDRANT SYSTEM, COMPLETE PIPING ANDACCESSORIES ETC. OUTSIDE THE PUMP HOUSEFOR 132KV SS SET 1 INCLUDED
255 PMU & associated item Ranpo 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 1 INCLUDED
256 PMU & associated item Ranpo 1000022512 WAMS Hardware - Time System (GPS receiver) EA 1 INCLUDED
257 PMU & associated item Ranpo 1000071061 SUBSTATION GRADE LAYER 2 LAN SWITCH EA 1 INCLUDED
258 PMU & associated item Ranpo 1000071062 SUBSTATION GRADE LAYER 3 LAN SWITCH EA 1 INCLUDED
259 PMU & associated item Ranpo 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 INCLUDED
260 PMU & associated item Ranpo 1000030641 LIU - FO PATCH PANEL-12 PORT EA 2 INCLUDED
RETENDER MISA SS NERES-XXVIII
261 GIS PORTION 420kV GIS eqpts 1000032796 420KV, 3150A, 63KA SF6 TO AIR BUSHING including support structure SET 3 INCLUDED
262 GIS PORTION 420kV GIS eqpts 1000059207 420KV, 3000A, 63KA, SINGLE PHASE, SF6 GAS INSULATED BUS DUCT (GIB)OUTSIDE GIS HALL ALONGWITH ASSOCIATED SUPPORT STRUCTURE, ETC. AS PERTECHNICAL SPECIFICATION M 450 INCLUDED
263 GIS PORTION 420kV GIS eqpts 1000032802 420KV, 4000A,63KA GIS BUSBAR MODULE EXTENSION SET 2 INCLUDED
264 GIS PORTION 420kV GIS eqpts 1000009713 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 2 INCLUDED
265 GIS PORTION 420kV GIS eqpts 1000004632 420kV, 3150 A, 63 kA, SF6 GIS BusReactor bay module as perSection-Project, Technicalspecification SET 1 INCLUDED
266 GIS PORTION 420kV GIS eqpts 1000004505 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 1 INCLUDED
267 GIS PORTION 420kV GIS eqpts 1000077607 420KV,4000A, 63KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULESUITABLE FOR EXTENDING EXISTING HITACHI MAKE GIS BUS BAR/DUCT AS PERTECHNICAL SPECIFICATION SET 2 INCLUDED
268 AIS equipments 1000020419 336kV Surge Arrester (1-phase) EA 3 INCLUDED
269 AIS equipments 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 6 INCLUDED
270 RELAY & PROTECTION PANEL 1000055446 400KV CIRCUIT BREAKER RELAY PANEL (WITH AUTOMATION) EA 2 INCLUDED
271 RELAY & PROTECTION PANEL 1000002146 Augmentation of existing 400kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 INCLUDED
272 RELAY & PROTECTION PANEL 1000003407 400kV Reactor Protection Panel (with Automation) EA 1 INCLUDED
273 SAS augmenttaion 1000003409 Augmentation of Substation automation System for 400kV Main bay as perTechnical Specification EA 1 INCLUDED
274 SAS augmenttaion 1000003411 Augmentation of Substation automation System for 400kV Tie bay as perTechnical Specification EA 1 INCLUDED
275 420kV Erection harware 1000011329 Erection Hardware for 400kV DM type layout for GIS terminationarrangement-Bus Reactor bay as per technical specification SET 1 INCLUDED
276 ventilation system 1000022409 Ventillation system for 400kV GIS Hall Ext SET 1 INCLUDED
277 power & control cable 1000000442 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
278 power & control cable 1000000443 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
279 power & control cable 1000000444 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED
280 Illumination (indoor) 1000049467 INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 INCLUDED
281 outdoor illumination 1000014547 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED
282 outdoor illumination 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED
283 outdoor illumination 1000038039 LIGHTING FIXTURE LED LUMINAIRES TYPE FL-1 AS PER TECH. SPECIFICATIONS EA 10 INCLUDED
284 outdoor illumination 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 1 INCLUDED
285 outdoor illumination 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED
286 outdoor illumination 1000038385 FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 4 INCLUDED
287 LT swgr extension 1000004304 415V ACDB (Extn.) SET 1 INCLUDED
288 LT swgr extension 1000001145 220V DCDB (Extn.) SET 1 INCLUDED
289 LT swgr extension 1000004309 415V MLDB (Extn.) SET 1 INCLUDED
290 fire protection system 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 2 INCLUDED
291 fire protection system 1000012026 6Kg dry chemical powered type Portable Fire extinguisher EA 2 INCLUDED
292 fire protection system 1000055457 HVW SPRAY SYSTEM, HYDRANT SYSTEM AND COMPLETE U/G & O/G PIPING ANDACCESSORIES ETC. OUT SIDE THE PUMP HOUSE FOR 420KV 3 PHASE BUSREACTOR SET 1 INCLUDED
293 fire protection system 1000012010 Fire Detection and Alarm System for 400kV GIS Hall SET 1 INCLUDED
294 fire protection system 1000012037 Hydrant system, complete U/G piping and accessories etc. outside thePump House for Fire Protection of 400/220kV (Ext) Substation SET 1 INCLUDED
295 earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 1 INCLUDED
296 mandatory spares 1000024186 SPARES FOR 336KV SURGE ARRESTER LS 1 INCLUDED
297 mandatory spares 1000025940 Spare-420kV BPI SET 1 INCLUDED
298 mandatory spares 1000019912 Relay & protection Panels (with automation) LS 1 INCLUDED
299 mandatory spares 1000019927 Spares-Substation Automation System LS 1 INCLUDED
300 mandatory spares 1000019925 Spares for Fire Protection System LS 1 INCLUDED
301 GIS PORTION -MANDATORY SPARES 1000058332 400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE EA 1 INCLUDED
302 GIS PORTION -MANDATORY SPARES 1000049817 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS SET 2 INCLUDED
303 GIS PORTION -MANDATORY SPARES 1000049753 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS SET 1 INCLUDED
304 GIS PORTION -MANDATORY SPARES 1000049762 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS SET 2 INCLUDED
305 GIS PORTION -MANDATORY SPARES 1000058330 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) SET 1 INCLUDED
306 GIS PORTION -MANDATORY SPARES 1000049750 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS SET 2 INCLUDED
307 GIS PORTION -MANDATORY SPARES 1000058331 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) LOT 1 INCLUDED
308 GIS PORTION -MANDATORY SPARES 1000049783 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS SET 2 INCLUDED
309 GIS PORTION -MANDATORY SPARES 1000049505 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS EA 3 INCLUDED
310 GIS PORTION -MANDATORY SPARES 1000058334 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
311 GIS PORTION -MANDATORY SPARES 1000058329 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS EA 3 INCLUDED
312 GIS PORTION -MANDATORY SPARES 1000058333 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT EA 1 INCLUDED
313 GIS PORTION -MANDATORY SPARES 1000049498 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS SET 1 INCLUDED
314 GIS PORTION -MANDATORY SPARES 1000058317 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT SET 1 INCLUDED
315 GIS PORTION -MANDATORY SPARES 1000021873 Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
316 GIS PORTION -MANDATORY SPARES 1000009208 Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) SET 3 INCLUDED
317 GIS PORTION -MANDATORY SPARES 1000058324 RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER SET 1 INCLUDED
318 GIS PORTION -MANDATORY SPARES 1000007067 Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker SET 1 INCLUDED
319 GIS PORTION -MANDATORY SPARES 1000058320 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
320 GIS PORTION -MANDATORY SPARES 1000049759 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
321 GIS PORTION -MANDATORY SPARES 1000058319 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
322 GIS PORTION -MANDATORY SPARES 1000058322 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) SET 1 INCLUDED
323 GIS PORTION -MANDATORY SPARES 1000049835 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
324 GIS PORTION -MANDATORY SPARES 1000049795 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
325 GIS PORTION -MANDATORY SPARES 1000049808 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
326 GIS PORTION -MANDATORY SPARES 1000049805 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
327 GIS PORTION -MANDATORY SPARES 1000058321 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
328 GIS PORTION -MANDATORY SPARES 1000049799 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
329 GIS PORTION -MANDATORY SPARES 1000058325 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) SET 1 INCLUDED
330 GIS PORTION -MANDATORY SPARES 1000058318 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) SET 1 INCLUDED
331 GIS PORTION -MANDATORY SPARES 1000049495 PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 1 INCLUDED
332 GIS PORTION -MANDATORY SPARES 1000049802 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER SET 1 INCLUDED
333 GIS PORTION -MANDATORY SPARES 1000058374 400kV GIS- Single phase of 3150Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect (Note 1- The contractorshall supply spare for disconnectorswitch to ensure one to one replacementof all disconnector switch supplied asmain equipment without any requirementof modification in fittings at site tocover all different types ofdisconnector switch supplied. In case,quantity of supplied dis-connectorswitch types (for one to onereplacement) are more than the quantitymentioned in BPS for spare, thecontractor shall supply theseadditional types of disconnector switchwithout any additional priceimplication to POWERGRID and quantitiesof these additional type ofdisconnector switch are deem to beincluded in the quantities mentioned inBPS for spare disconnector. Note 2 - Incase, Dis-connector Switch (DS) & EarthSwitch (ES) is provided in a sameenclosure with common operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with common operatingmechanism is to be provided under thehead of spare Dis-connector only. Note3- In case, Dis-connector Switch (DS)&Earth Switch (ES) is provided in asame enclosure with separate operatingmechanism, then the module comprisingof Dis-connector & Earth switch insingle enclosure with separateoperating mechanism is to be providedunder the head of spare Dis-connectoronly.) EA 2 INCLUDED
334 GIS PORTION -MANDATORY SPARES 1000058314 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT (NOTE 1 - IN CASE, DIS-CONNECTOR SWITCH (DS) &EARTH SWITCH (ES) IS PROVIDED IN A SAME ENCLOSURE WITH COMMONOPERATING MECHANISM, THEN THE MODULE COMPRISING OF DIS-CONNECTOR &EARTH SWITCH IN SINGLE ENCLOSURE WITH COMMON OPERATING MECHANISM IS TOBE PROVIDED UNDER THE HEAD OF SPARE DIS-CONNECTOR ONLY. NOTE 2 - INCASE, DIS-CONNECTOR SWITCH (DS) & EARTH SWITCH (ES) IS PROVIDED IN ASAME ENCLOSURE WITH SEPARATE OPERATING MECHANISM, THEN THE MODULECOMPRISING OF DIS-CONNECTOR & EARTH SWITCH IN SINGLE ENCLOSURE WITHSEPARATE OPERATING MECHANISM IS TO BE PROVIDED UNDER THE HEAD OF SPAREDIS-CONNECTOR ONLY.) EA 1 INCLUDED
335 GIS PORTION -MANDATORY SPARES 1000058305 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH SET 1 INCLUDED
336 GIS PORTION -MANDATORY SPARES 1000058312 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH SET 1 INCLUDED
337 GIS PORTION -MANDATORY SPARES 1000049776 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS SET 1 INCLUDED
338 GIS PORTION -MANDATORY SPARES 1000049778 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS SET 1 INCLUDED
339 GIS PORTION -MANDATORY SPARES 1000058306 DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH SET 1 INCLUDED
340 GIS PORTION -MANDATORY SPARES 1000058313 DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH SET 1 INCLUDED
341 GIS PORTION -MANDATORY SPARES 1000058307 MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH EA 1 INCLUDED
342 GIS PORTION -MANDATORY SPARES 1000058315 MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH EA 1 INCLUDED
343 GIS PORTION -MANDATORY SPARES 1000058327 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED
344 GIS PORTION -MANDATORY SPARES 1000058326 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT EA 1 INCLUDED
345 supply of foundation bolt 1000012367 Fabrication, galvanising and supply of 32mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 36 INCLUDED
346 Supply of structure 1000020195 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 3 INCLUDED
347 Supply of structure 1000020196 Fabrication, galvanising and supply ofStd Pipe Structure - 400 kV, 1-Phase,BPI, (Excluding Wave Trap), includingnuts, bolts, all type of washers,packplates, step bolts and gussetplates excluding foundation bolts EA 6 INCLUDED
348 Supply of structure 1000015952 Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 5 INCLUDED
349 Supply of structure 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 1 INCLUDED
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 3
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(SCHEDULE OF RATES AND PRICES )
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurugram (Haryana) - 122001
Installation Charges : (All Prices are in Indian Rupees)
SI. No. Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Erection Charges Total Erection Charges GST Before Discount Discount Total Price after discount GST After Discount
Re-tender-NIT-BOQ-Pandiabil SS (ERBS-I) 0 0 0.0000000000 0 0 0.00 18 0
1 Inst-AIS EQUIPMENT 100005443 998734 18 420KV, 1-PHASE BUS POST INSULATORS EA 6 INCLUDED 0 0.0000000000 0 0 18 0
2 Inst-AIS EQUIPMENT 100000328 998736 18 336kV Surge Arrester (1-phase) EA 6 INCLUDED 0 0.0000000000 0 0 18 0
3 Inst-AIS EQUIPMENT 100000275 998736 18 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 6 INCLUDED 0 0.0000000000 0 0 18 0
4 Inst-AIS EQUIPMENT 100002042 998734 18 400kV,3150A,0.5mH ,63kA Line Trap EA 4 INCLUDED 0 0.0000000000 0 0 18 0
5 Inst-AIS EQUIPMENT 100000883 998734 18 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 INCLUDED 0 0.0000000000 0 0 18 0
6 Inst-400KV GIS EQUIPMENT 100002140 998736 18 420kV, 3000A/3150, 63kA, Single phase, SF6 Gas Insulated Bus Duct (GIB) outsideGIS Hall along with associated support structure M 600 INCLUDED 0 0.0000000000 0 0 18 0
7 Inst-400KV GIS EQUIPMENT 100002392 998736 18 420kV, SF6 to Air Bushing alongwithassociated support structure for 3150A,63 kA for 1 sec. Single Phase EA 6 INCLUDED 0 0.0000000000 0 0 18 0
8 Inst-400KV GIS EQUIPMENT 100003557 998736 18 Extension of 420kV , 4000 A, 63 kA3 -phase SF6 GIS bus bar SET 2 INCLUDED 0 0.0000000000 0 0 18 0
9 Inst-400KV GIS EQUIPMENT 100001826 998736 18 420kV, 3150 A, 63 kA, SF6 GIS ICT feeder bay module as per Section-Project, Technical specification SET 1 INCLUDED 0 0.0000000000 0 0 18 0
10 Inst-400KV GIS EQUIPMENT 100005502 998736 18 Three nos 1-Phase/One no 3-Phase 420kV GIS earthing switch including of maincircuit, enclosure, driving mechanism. SET 1 INCLUDED 0 0.0000000000 0 0 18 0
11 Inst-400KV GIS EQUIPMENT 100002135 998736 18 420 kV, 3150 A, 63 kA, SF6 GIS Line feeder bay module(with PIR) as per Section-Project, Technical specification SET 1 INCLUDED 0 0.0000000000 0 0 18 0
12 Inst-400KV GIS EQUIPMENT 100002132 998736 18 420kV, 3150 A, 63 kA, SF6 GIS Tie bay module(without PIR) as per Section-Project, Technical specification SET 1 INCLUDED 0 0.0000000000 0 0 18 0
13 Inst-400KV GIS EQUIPMENT 100057110 998736 18 420kV,4000A, 63kA, 3-Phase GIS Extension Piece (Interface) module suitable for extending existing HYOSUNG make GIS Bus Bar/Duct asper Technical Specification SET 2 INCLUDED 0 0.0000000000 0 0 18 0
14 Inst-400KV GIS EQUIPMENT 100000268 998736 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 3 INCLUDED 0 0.0000000000 0 0 18 0
15 Inst-CRP 100000730 998736 18 400kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0.0000000000 0 0 18 0
16 Inst-CRP 100016779 998736 18 400kV Circuit Breaker Relay Panel (with Automation) EA 3 INCLUDED 0 0.0000000000 0 0 18 0
17 Inst-CRP 100000735 998736 18 Augmentation of existing 400kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
18 Inst-Aug-SAS 100002069 998736 18 Augmentation of Substation automation System for 400kV Main bay as per Technical Specification EA 3 INCLUDED 0 0.0000000000 0 0 18 0
19 Inst-Aug-SAS 100002075 998736 18 Augmentation of Substation automation System for 400kV Tie bay as per Technical Specification EA 1 INCLUDED 0 0.0000000000 0 0 18 0
20 Inst-ERECTION HARDWARE & INSULATOR 100002187 998731 18 Erection Hardware for 400kV I type layout for GIS termination arrangement-Line bay as per technical specification SET 2 INCLUDED 0 0.0000000000 0 0 18 0
21 Inst-Illumination 100001051 998731 18 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as per technical specifications EA 1 INCLUDED 0 0.0000000000 0 0 18 0
22 Inst-Illumination 100001052 998731 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 2 INCLUDED 0 0.0000000000 0 0 18 0
23 Inst-Illumination 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 10 INCLUDED 0 0.0000000000 0 0 18 0
24 Inst-Illumination 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED 0 0.0000000000 0 0 18 0
25 Inst-Illumination 100001050 998731 18 5/15 A, 240V: Indoor Receptacle 3-pin type modular (type RI) as per technical specifications EA 1 INCLUDED 0 0.0000000000 0 0 18 0
26 Inst-Illumination 100001020 998731 18 Lighting Panel (Indoor) type ACP-1 as per technical specification EA 1 INCLUDED 0 0.0000000000 0 0 18 0
27 Inst-Illumination 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 10 INCLUDED 0 0.0000000000 0 0 18 0
28 Inst-VMS 100002500 998731 18 Color IP camera, with PAN, TILT and ZOOM facilities, alongwith all required Items, Accessories, Line Interface units, Fiber patchcords, Power supply units, Junction Boxes, Cables, Fiber Optic Cables, etc., and including Integration in existing Hardware andSoftware for Augmentation of Visual Monitoring System as per technical specification. SET 1 INCLUDED 0 0.0000000000 0 0 18 0
29 Inst-LT SWITCHGEAR 100000896 998736 18 415V ACDB (Extn.) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
30 Inst-PLCC Equipment at Pandiabili end 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0.0000000000 0 0 18 0
31 Inst-PLCC Equipment at Pandiabili end 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
32 Inst-PLCC Equipment at Pandiabili end 100000890 998734 18 Protection Coupler (Analog) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
33 Inst-PLCC Equipment at Pandiabili end 100000891 998734 18 Digital Protection Coupler EA 1 INCLUDED 0 0.0000000000 0 0 18 0
34 Inst-PLCC Equipment at Pandiabili end 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 1 INCLUDED 0 0.0000000000 0 0 18 0
35 Inst-PLCC Equipment at Pandiabili end 100002762 998734 18 PLCC-Equipments-Telephone Instruments (2 wire) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
36 Inst-PLCC Equipment at Talchar end 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0.0000000000 0 0 18 0
37 Inst-PLCC Equipment at Talchar end 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
38 Inst-PLCC Equipment at Talchar end 100000890 998734 18 Protection Coupler (Analog) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
39 Inst-PLCC Equipment at Talchar end 100000891 998734 18 Digital Protection Coupler EA 1 INCLUDED 0 0.0000000000 0 0 18 0
40 Inst-PLCC Equipment at Talchar end 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 1 INCLUDED 0 0.0000000000 0 0 18 0
41 Inst-PLCC Equipment at Talchar end 100002762 998734 18 PLCC-Equipments-Telephone Instruments (2 wire) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
42 Inst-Power&Control Cable (LS) 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0.0000000000 0 0 18 0
43 Inst-Power&Control Cable (LS) 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0.0000000000 0 0 18 0
44 service-civil work 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 1837 INCLUDED 0 0.0000000000 0 0 18 0
45 service-civil work 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 1224 INCLUDED 0 0.0000000000 0 0 18 0
46 service-civil work 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 77 INCLUDED 0 0.0000000000 0 0 18 0
47 service-civil work 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 5 INCLUDED 0 0.0000000000 0 0 18 0
48 service-civil work 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 92 INCLUDED 0 0.0000000000 0 0 18 0
49 service-civil work 100016607 995451 18 Providing and laying of Reinforced Cement Concrete M30 including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 550 INCLUDED 0 0.0000000000 0 0 18 0
50 service-civil work 100016681 995454 18 Reinforcement steel meeting corrosion resistance properties as per IS:1786 and manufacturer specification​ MT 44 INCLUDED 0 0.0000000000 0 0 18 0
51 service-civil work 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 1200 INCLUDED 0 0.0000000000 0 0 18 0
52 service-civil work 100001713 995424 18 Antiweed treatment M2 1200 INCLUDED 0 0.0000000000 0 0 18 0
53 service-civil work 100008110 995421 18 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 188 INCLUDED 0 0.0000000000 0 0 18 0
54 service-civil work 100008611 995477 18 Swtichyard fencing: Providing and fixing fencing of GI barbed wire consisting of galvanized MS tubular posts at 3 m intervals; GIbarded wire shall run horizontally from post to post at a spacing of 300 mm (vertically) and a cross formation in each panel,complete as per technical specification and drawing. M 50 INCLUDED 0 0.0000000000 0 0 18 0
55 service-civil work 100020960 995461 18 RCC culvert crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as per specification. M 10 INCLUDED 0 0.0000000000 0 0 18 0
56 service-civil work 100020961 995461 18 RCC culvert crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as per specification. M 10 INCLUDED 0 0.0000000000 0 0 18 0
57 service-civil work 100020962 995461 18 RCC culvert crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as per specification. M 10 INCLUDED 0 0.0000000000 0 0 18 0
58 service-civil work 100001412 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section A-A M 25 INCLUDED 0 0.0000000000 0 0 18 0
59 service-civil work 100001413 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section B-B M 50 INCLUDED 0 0.0000000000 0 0 18 0
60 service-civil work 100001414 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section C-C M 15 INCLUDED 0 0.0000000000 0 0 18 0
61 service-civil work 100001415 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section D-D M 10 INCLUDED 0 0.0000000000 0 0 18 0
62 service-civil work 100001479 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 3-3 M 50 INCLUDED 0 0.0000000000 0 0 18 0
63 service-civil work 100001480 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 4-4 M 50 INCLUDED 0 0.0000000000 0 0 18 0
64 service-civil work 100002911 995432 18 Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 1632 INCLUDED 0 0.0000000000 0 0 18 0
65 service-civil work 100002583 995432 18 Supply of earth (excluding rock & boulders) at site including royalty, carriage and filling in specified areas in layers notexceeding 200mm in depth, compacting under optimum moisture condition to achieve 95% of Proctor density, finishing etc. allcomplete, for all leads & lifts, with all labour, material, tools, tackles, equipments, safeguards & incidentals as necessary as perdrawings, specification and direction of the Engineer- in- Charge. M3 2448 INCLUDED 0 0.0000000000 0 0 18 0
66 service-civil work 100002914 995432 18 Earthwork in excavation in Hard rocks in open areas/nallas/ channels, to the required slopes, shapes, levels, elevations andprofile, including trimming of bottom and slopes of excavation and stacking and disposal of rock for a lead up to 2.0 KM beyondleveling boundary and all lifts , with all labour, material, tools, tackles and equipment, safeguards and incidentals,Royalty,taxesetc. as per directions of the Engineer-in-Charge. Serviceable material if available shall be stacked at site as identified byEngineer-in-Charge.(50% void deduction from stack measurement) M3 816 INCLUDED 0 0.0000000000 0 0 18 0
67 service-civil work 100001542 995429 18 Dismantling & Re-erection of Existing fence M 50 INCLUDED 0 0.0000000000 0 0 18 0
68 service-civil work 100001447 995429 18 Dismantling of existing fencing M 50 INCLUDED 0 0.0000000000 0 0 18 0
69 service-civil work 100039866 995432 18 Soil Investigation for 02 borehole locations: As per technical specification including all laboratory and field tests, report andrecommendations. LOT 1 INCLUDED 0 0.0000000000 0 0 18 0
70 service- erection steel structure 100001210 995455 18 Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 90 INCLUDED 0 0.0000000000 0 0 18 0
71 service- erection steel structure 100001209 995455 18 Erection of Lattice Structures (HT Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts. MT 27 INCLUDED 0 0.0000000000 0 0 18 0
72 service- erection steel structure 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 7 INCLUDED 0 0.0000000000 0 0 18 0
73 service- erection steel structure 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 10 INCLUDED 0 0.0000000000 0 0 18 0
74 PMU & associated items (Pandiabili) 170000502 998713 18 Service:- Phasor Measurement Unit (PMU) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
75 PMU & associated items (Pandiabili) 170000530 998734 18 WAMS TIME SYSTEM(GPS RECEIVER) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
76 PMU & associated items (Pandiabili) 170004701 998734 18 SUBSTATION GRADE Layer 2 LAN SWITCH EA 1 INCLUDED 0 0.0000000000 0 0 18 0
77 PMU & associated items (Pandiabili) 170004700 998734 18 SUBSTATION GRADE Layer 3 LAN SWITCH EA 1 INCLUDED 0 0.0000000000 0 0 18 0
78 PMU & associated items (Pandiabili) 170000504 998713 18 Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 INCLUDED 0 0.0000000000 0 0 18 0
79 PMU & associated items (Pandiabili) 170003449 998316 18 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LIU-FO PATCH PANEL-12 PORT EA 2 INCLUDED 0 0.0000000000 0 0 18 0
80 PMU & associated items (Pandiabili) 170000501 998734 18 Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 INCLUDED 0 0.0000000000 0 0 18 0
81 Service- Telecome eqpt 100002812 998734 18 SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 INCLUDED 0 0.0000000000 0 0 18 0
82 Service- Telecome eqpt 170000433 998734 18 Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 INCLUDED 0 0.0000000000 0 0 18 0
83 Service- Telecome eqpt 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 INCLUDED 0 0.0000000000 0 0 18 0
84 Service- Telecome eqpt 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 INCLUDED 0 0.0000000000 0 0 18 0
85 Service- Telecome eqpt 100002829 998734 18 Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
86 Service- Telecome eqpt 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 INCLUDED 0 0.0000000000 0 0 18 0
87 Service- Telecome eqpt 170000356 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
88 Service- Telecome eqpt 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
89 Service- Telecome eqpt 170004395 998336 18 Fibre Optic Approach cabling: Including installation hardware like GI pipe, elbow, conduits, accessories etc.: 48 Fibre KM 1 INCLUDED 0 0.0000000000 0 0 18 0
Re-tender-NIT-BOQ-Rangpo SS(ERBS-II) 0 0.0000000000 0 0 18 -18
90 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 100004753 998736 18 145kV, 1600, 31.5kA, for 1 sec SF6 GIS Bus bar Extension module as per Section-Project, Technical specification SET 2 INCLUDED 0 0.0000000000 0 0 18 0
91 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 100000525 998736 18 145kV, 1250 A, 31.5 kA, 3-Phase SF6 GIS Line feeder bay module for connecting Overhead line (Air/SF6) with GIS through gasinsulated interconnection bus etc. to complete feeder bay module SET 2 INCLUDED 0 0.0000000000 0 0 18 0
92 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 100002415 998736 18 145 Kv SF6 Gas Insulated Bus Duct (GIB)outside GIS hall including Bus Ductsupport structure and associatedaccessories for 1250A, 31.5kA, 1secthree phase M 200 INCLUDED 0 0.0000000000 0 0 18 0
93 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 100003241 998736 18 145kV, 1250A, 31.5kA SF6/Air Bushing for Connecting GIS to AIS alongwith support structure SET 6 INCLUDED 0 0.0000000000 0 0 18 0
94 GIS Portion-145kV, 31.5kA GIS EQUIPMENT 100057761 998736 18 145KV, 1600A, 31.5KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULE SUITABLE FOR EXTENDING EXISTING HYOSUNG MAKE GIS BUS BAR/DUCTAS PER TECHNICAL SPECIFICATION EA 2 INCLUDED 0 0.0000000000 0 0 18 0
95 145kV, 31.5kA AIS EQUIPMENT 100000587 998736 18 120kV Surge Arrester(1-phase) EA 6 INCLUDED 0 0.0000000000 0 0 18 0
96 145kV, 31.5kA AIS EQUIPMENT 100001908 998736 18 145kV ,1 phase Bus Post Insulators EA 12 INCLUDED 0 0.0000000000 0 0 18 0
97 145kV, 31.5kA AIS EQUIPMENT 100000559 998736 18 145 kV, 8800pf, 1-phase Capacitive Voltage Transformer EA 6 INCLUDED 0 0.0000000000 0 0 18 0
98 145kV, 31.5kA AIS EQUIPMENT 100015346 998734 18 132 kV, 800A, 0.5mH, 31.5kA Line Trap EA 2 INCLUDED 0 0.0000000000 0 0 18 0
99 Erection HW for 132 kV DM Type 100002165 998731 18 Erection Hardware for 132kV DM type layout for GIS termination arrangement-Line bay as per technical specification SET 2 INCLUDED 0 0.0000000000 0 0 18 0
100 CRP for 132 kV Bays with SAS 100000746 998736 18 132kV Line Protection Panel (with Automation) EA 2 INCLUDED 0 0.0000000000 0 0 18 0
101 CRP for 132 kV Bays with SAS 100016777 998736 18 132kV Circuit Breaker Relay Panel (with Automation) EA 2 INCLUDED 0 0.0000000000 0 0 18 0
102 CRP for 132 kV Bays with SAS 100000750 998736 18 Augmentation of existing 132kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
103 SAS 100002071 998736 18 Augmentation of Substation automation System for 132kV bay as per Technical Specification EA 1 INCLUDED 0 0.0000000000 0 0 18 0
104 PLCC 132kV Rangpo end 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0.0000000000 0 0 18 0
105 PLCC 132kV Rangpo end 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
106 PLCC 132kV Rangpo end 100000890 998734 18 Protection Coupler (Analog) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
107 PLCC 132kV Rangpo end 100000891 998734 18 Digital Protection Coupler EA 1 INCLUDED 0 0.0000000000 0 0 18 0
108 PLCC 132kV Rangpo end 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 0.5 INCLUDED 0 0.0000000000 0 0 18 0
109 PLCC 132kV Rammam end 100000886 998734 18 Coupling device for PLCC EA 1 INCLUDED 0 0.0000000000 0 0 18 0
110 PLCC 132kV Rammam end 100000888 998734 18 Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
111 PLCC 132kV Rammam end 100000890 998734 18 Protection Coupler (Analog) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
112 PLCC 132kV Rammam end 100000891 998734 18 Digital Protection Coupler EA 1 INCLUDED 0 0.0000000000 0 0 18 0
113 PLCC 132kV Rammam end 100003517 998734 18 HF CABLE FOR PLCC-75 OHM (KM) KM 0.5 INCLUDED 0 0.0000000000 0 0 18 0
114 POWER & CONTROL CABLE 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0.0000000000 0 0
115 POWER & CONTROL CABLE 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0.0000000000 0 0 18 0
116 ILLUMINATION SYSTEM 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 2 INCLUDED 0 0.0000000000 0 0 18 0
117 ILLUMINATION SYSTEM 100001052 998731 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 1 INCLUDED 0 0.0000000000 0 0 18 0
118 ILLUMINATION SYSTEM 100004930 998731 18 LED Flood Light Luminaries Type-FL-1 as per technical specification EA 5 INCLUDED 0 0.0000000000 0 0 18 0
119 ILLUMINATION SYSTEM 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 5 INCLUDED 0 0.0000000000 0 0 18 0
120 ILLUMINATION SYSTEM 100008185 998736 18 Indoor Lightning for GIS Building (As per Technical specification) including AHU & Relay Rooms as applicable SET 1 INCLUDED 0 0.0000000000 0 0 18 0
121 ILLUMINATION SYSTEM 100001020 998731 18 Lighting Panel (Indoor) type ACP-1 as per technical specification EA 2 INCLUDED 0 0.0000000000 0 0 18 0
122 GIS common eqpt 100003603 998736 18 EOT Crane Extension for GIS Building for 132kV GIS station SET 1 INCLUDED 0 0.0000000000 0 0 18 0
123 VMS 100002500 998731 18 Color IP camera, with PAN, TILT and ZOOM facilities, alongwith all required Items, Accessories, Line Interface units, Fiber patchcords, Power supply units, Junction Boxes, Cables, Fiber Optic Cables, etc., and including Integration in existing Hardware andSoftware for Augmentation of Visual Monitoring System as per technical specification. SET 1 INCLUDED 0 0.0000000000 0 0 18 0
124 Air conditioning 100000960 995463 18 High wall type split AC unit of 2 TR capacity EA 4 INCLUDED 0 0.0000000000 0 0 18 0
125 Civil Service 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 1171 INCLUDED 0 0.0000000000 0 0 18 0
126 Civil Service 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 200 INCLUDED 0 0.0000000000 0 0 18 0
127 Civil Service 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 73 INCLUDED 0 0.0000000000 0 0 18 0
128 Civil Service 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 27 INCLUDED 0 0.0000000000 0 0 18 0
129 Civil Service 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 60 INCLUDED 0 0.0000000000 0 0 18 0
130 Civil Service 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 397 INCLUDED 0 0.0000000000 0 0 18 0
131 Civil Service 100001329 995454 18 Steel Reinforcement MT 32 INCLUDED 0 0.0000000000 0 0 18 0
132 Civil Service 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 10 INCLUDED 0 0.0000000000 0 0 18 0
133 Civil Service 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 800 INCLUDED 0 0.0000000000 0 0 18 0
134 Civil Service 100001713 995424 18 Antiweed treatment M2 800 INCLUDED 0 0.0000000000 0 0 18 0
135 Civil Service 100001379 995421 18 3.75m wide Concrete road (including all crossings) as per drawing except reinforcement & concrete in Switchyard M2 75 INCLUDED 0 0.0000000000 0 0 18 0
136 Civil Service 170002351 995421 18 DISMANTLING OF EXISTING -CONCRETE ROAD . M2 75 INCLUDED 0 0.0000000000 0 0 18 0
137 Civil Service 100003972 995416 18 EXTENSION OF 132 KV GIS HALL BUILDING (RCC) EXCLUDING EXCAVATION,PCC,RCC AND REINFORCEMENT BUT INCLUDING FINISHING (INTERNAL &EXTERNAL) & ALL CIVIL WORKS INCLUDING INTERNAL FOUNATIONS AND CABLE TRENCH ETC. COMPLETE IN ALL RESPECT AS PER SPECIFICATION M2 60 INCLUDED 0 0.0000000000 0 0 18 0
138 Civil Service 100001694 995416 18 132 kV Panel Room - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc.However excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 25 INCLUDED 0 0.0000000000 0 0 18 0
139 Civil Service 100001391 995477 18 New chain Link Fencing excluding concrete M 100 INCLUDED 0 0.0000000000 0 0 18 0
140 Civil Service 100001542 995429 18 Dismantling & Re-erection of Existing fence M 100 INCLUDED 0 0.0000000000 0 0 18 0
141 Civil Service 100001735 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 10 INCLUDED 0 0.0000000000 0 0 18 0
142 Civil Service 100001736 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 20 INCLUDED 0 0.0000000000 0 0 18 0
143 Civil Service 100001737 995462 18 RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 10 INCLUDED 0 0.0000000000 0 0 18 0
144 Civil Service 100001412 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section A-A M 10 INCLUDED 0 0.0000000000 0 0 18 0
145 Civil Service 100001413 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section B-B M 10 INCLUDED 0 0.0000000000 0 0 18 0
146 Civil Service 100001414 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section C-C M 10 INCLUDED 0 0.0000000000 0 0 18 0
147 Civil Service 100001415 995462 18 Drain including culverts but excluding concrete & reinforcement steel-Section D-D M 10 INCLUDED 0 0.0000000000 0 0 18 0
148 Civil Service 100001392 995455 18 Switchyard Gate excluding Concrete EA 1 INCLUDED 0 0.0000000000 0 0 18 0
149 Civil Service 100002911 995432 18 Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 50 INCLUDED 0 0.0000000000 0 0 18 0
150 Non Standard Structures(Civil Works) 100001210 995455 18 Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 20 INCLUDED 0 0.0000000000 0 0 18 0
151 Non Standard Structures(Civil Works) 100001680 995455 18 Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 2 INCLUDED 0 0.0000000000 0 0 18 0
152 Non Standard Structures(Civil Works) 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 3 INCLUDED 0 0.0000000000 0 0 18 0
153 LT Switchgear 100000896 998736 18 415V ACDB (Extn.) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
154 Telecom Eqpt Service 100002812 998734 18 SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 INCLUDED 0 0.0000000000 0 0 18 0
155 Telecom Eqpt Service 170000433 998734 18 Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 INCLUDED 0 0.0000000000 0 0 18 0
156 Telecom Eqpt Service 100002825 998734 18 Tributary interface- E1 interface (Minimum 16 nos.) SET 2 INCLUDED 0 0.0000000000 0 0 18 0
157 Telecom Eqpt Service 170000550 998336 18 Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 INCLUDED 0 0.0000000000 0 0 18 0
158 Telecom Eqpt Service 100002829 998734 18 Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
159 Telecom Eqpt Service 170000375 998734 18 Equipment Cabinets-For SDH Equipments EA 1 INCLUDED 0 0.0000000000 0 0 18 0
160 Telecom Eqpt Service 170000551 998336 18 VOIP telephone instrument with one common switch (min. 8 port) EA 2 INCLUDED 0 0.0000000000 0 0 18 0
161 Telecom Eqpt Service 170000356 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
162 Telecom Eqpt Service 170004395 998336 18 Fibre Optic Approach cabling: Including installation hardware like GI pipe, elbow, conduits, accessories etc.: 48 Fibre KM 1 INCLUDED 0 0.0000000000 0 0 18 0
163 Fire Protection System 100002061 995461 18 Fire Detection and Alarm System for 132kV GIS Hall SET 1 INCLUDED 0 0.0000000000 0 0 18 0
164 Fire Protection System 100004863 998736 18 HYDRANT SYSTEM, COMPLETE PIPING ANDACCESSORIES ETC. OUTSIDE THE PUMP HOUSEFOR 132KV SS SET 1 INCLUDED 0 0.0000000000 0 0 18 0
165 PMU & associated item Ranpo 170000502 998713 18 Service:- Phasor Measurement Unit (PMU) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
166 PMU & associated item Ranpo 170000530 998734 18 WAMS TIME SYSTEM(GPS RECEIVER) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
167 PMU & associated item Ranpo 170004701 998734 18 SUBSTATION GRADE Layer 2 LAN SWITCH EA 1 INCLUDED 0 0.0000000000 0 0 18 0
168 PMU & associated item Ranpo 170004700 998734 18 SUBSTATION GRADE Layer 3 LAN SWITCH EA 1 INCLUDED 0 0.0000000000 0 0 18 0
169 PMU & associated item Ranpo 170000504 998713 18 Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 INCLUDED 0 0.0000000000 0 0 18 0
170 PMU & associated item Ranpo 170003449 998316 18 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LIU-FO PATCH PANEL-12 PORT EA 2 INCLUDED 0 0.0000000000 0 0 18 0
171 PMU & associated item Ranpo 170000501 998734 18 Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 INCLUDED 0 0.0000000000 0 0 18 0
RETENDER MISA SS NERES-XXVIII 0 0.0000000000 0 0 18 -18
172 GIS PORTION SERVICE 420KV GIS EQPT 100001840 998736 18 420kV, 3150 A, 63 kA, SF6 GIS Bus Reactor bay module as per Section-Project, Technical specification SET 1 INCLUDED 0 0.0000000000 0 0 18 0
173 GIS PORTION SERVICE 420KV GIS EQPT 100002392 998736 18 420kV, SF6 to Air Bushing alongwithassociated support structure for 3150A,63 kA for 1 sec. Single Phase EA 3 INCLUDED 0 0.0000000000 0 0 18 0
174 GIS PORTION SERVICE 420KV GIS EQPT 100002140 998736 18 420kV, 3000A/3150, 63kA, Single phase, SF6 Gas Insulated Bus Duct (GIB) outsideGIS Hall along with associated support structure M 450 INCLUDED 0 0.0000000000 0 0 18 0
175 GIS PORTION SERVICE 420KV GIS EQPT 100003557 998736 18 Extension of 420kV , 4000 A, 63 kA3 -phase SF6 GIS bus bar SET 2 INCLUDED 0 0.0000000000 0 0 18 0
176 GIS PORTION SERVICE 420KV GIS EQPT 100000268 998736 18 Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 2 INCLUDED 0 0.0000000000 0 0 18 0
177 GIS PORTION SERVICE 420KV GIS EQPT 100002132 998736 18 420kV, 3150 A, 63 kA, SF6 GIS Tie bay module(without PIR) as per Section-Project, Technical specification SET 1 INCLUDED 0 0.0000000000 0 0 18 0
178 GIS PORTION SERVICE 420KV GIS EQPT 100057113 998736 18 420kV,4000A, 63kA, 3-Phase GIS Extension Piece (Interface) module suitable for extending existing HITACHI make GIS Bus Bar/Duct asper Technical Specification SET 2 INCLUDED 0 0.0000000000 0 0 18 0
179 SERVICE 420KV AIS EQUIPMENTS 100000328 998736 18 336kV Surge Arrester (1-phase) EA 3 INCLUDED 0 0.0000000000 0 0 18 0
180 SERVICE 420KV AIS EQUIPMENTS 100000340 998736 18 420 kV Bus Post Insulator (Except for wave traps) EA 6 INCLUDED 0 0.0000000000 0 0 18 0
181 SERVICE RELAY & PROTECTION PANEL 100016779 998736 18 400kV Circuit Breaker Relay Panel (with Automation) EA 2 INCLUDED 0 0.0000000000 0 0 18 0
182 SERVICE RELAY & PROTECTION PANEL 100000735 998736 18 Augmentation of existing 400kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
183 SERVICE RELAY & PROTECTION PANEL 100000732 998736 18 400kV Reactor Protection Panel (with Automation) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
184 SERVICE SAS AUGMENTATION 100002069 998736 18 Augmentation of Substation automation System for 400kV Main bay as per Technical Specification EA 1 INCLUDED 0 0.0000000000 0 0 18 0
185 SERVICE SAS AUGMENTATION 100002075 998736 18 Augmentation of Substation automation System for 400kV Tie bay as per Technical Specification EA 1 INCLUDED 0 0.0000000000 0 0 18 0
186 SERVICE 420KV ERECTION HARWARE 100002163 998731 18 Erection Hardware for 400kV DM type layout for GIS termination arrangement-Bus Reactor bay as per technical specification SET 1 INCLUDED 0 0.0000000000 0 0 18 0
187 SERVICE VENTILATION SYSTEM 100001878 995463 18 Ventillation system for 400kV GIS Hall Ext SET 1 INCLUDED 0 0.0000000000 0 0 18 0
188 SERVICE POWER & CONTRL CABLE 100002181 998736 18 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0.0000000000 0 0 18 0
189 SERVICE POWER & CONTRL CABLE 100002182 998736 18 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0.0000000000 0 0 18 0
190 SERVICE POWER & CONTRL CABLE 100002180 998736 18 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 INCLUDED 0 0.0000000000 0 0 18 0
191 SERVICE ILLUMINATION INDOOR 100008185 998736 18 Indoor Lightning for GIS Building (As per Technical specification) including AHU & Relay Rooms as applicable SET 1 INCLUDED 0 0.0000000000 0 0 18 0
192 SERVICE ILLUMINATION OUTDOOR 100001021 995461 18 Lighting Panel type ACP-2 as per technical specification EA 1 INCLUDED 0 0.0000000000 0 0 18 0
193 SERVICE ILLUMINATION OUTDOOR 100004926 998731 18 Lighting Fixture LED Luminaires type FL2 as per tech. specifications EA 10 INCLUDED 0 0.0000000000 0 0 18 0
194 SERVICE ILLUMINATION OUTDOOR 100004852 998731 18 Lighting Fixture LED Luminaires type FL-1 as per tech. specifications EA 10 INCLUDED 0 0.0000000000 0 0 18 0
195 SERVICE ILLUMINATION OUTDOOR 100001052 998731 18 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 1 INCLUDED 0 0.0000000000 0 0 18 0
196 SERVICE ILLUMINATION OUTDOOR 100001885 998739 18 Outdoor Power Receptacle for oilfiltration unit (250A) EA 1 INCLUDED 0 0.0000000000 0 0 18 0
197 SERVICE ILLUMINATION OUTDOOR 100004937 998731 18 Fire Wall Mounted LED Luminarie Type FL-2 (250W) EA 4 18 0
198 SERVICE LT SWGR EXTENSION 100000896 998736 18 415V ACDB (Extn.) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
199 SERVICE LT SWGR EXTENSION 100000903 998736 18 220V DCDB (Extn.) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
200 SERVICE LT SWGR EXTENSION 100000898 998736 18 415V MLDB (Extn.) SET 1 INCLUDED 0 0.0000000000 0 0 18 0
201 SERVICE FIRE PROTECTION 100002059 995461 18 Fire Detection and Alarm System for 400kV GIS Hall SET 1 INCLUDED 0 0.0000000000 0 0 18 0
202 SERVICE FIRE PROTECTION 100016787 998736 18 HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 420kV 3 phase BUSReactor SET 1 INCLUDED 0 0.0000000000 0 0 18 0
203 SERVICE FIRE PROTECTION 100000975 995461 18 4.5 kg CO2 type Portable Fire extinguisher EA 2 INCLUDED 0 0.0000000000 0 0 18 0
204 SERVICE FIRE PROTECTION 100000976 998736 18 6Kg dry chemical powered type Portable Fire extinguisher EA 2 INCLUDED 0 0.0000000000 0 0 18 0
205 SERVICE FIRE PROTECTION 100001868 998736 18 Hydrant system, complete U/G piping and accessories etc. outside the Pump House for Fire Protection of 400/220kV (Ext) Substation SET 1 INCLUDED 0 0.0000000000 0 0 18 0
206 SERVICE EARTHMAT 100003103 998731 18 40 mm MS rod for Main Earthmat KM 1 INCLUDED 0 0.0000000000 0 0 18 0
207 civil works 100004518 995433 18 Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 2455 INCLUDED 0 0.0000000000 0 0 18 0
208 civil works 100011662 995433 18 Excavation in hard rock which require blasting (including chemical blasting and rock excavated using specialized tools) for allfoundation works including stacking, measuring, disposal etc.for all leads and lifts as per technical specification. M3 245 INCLUDED 0 0.0000000000 0 0 18 0
209 civil works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 115 INCLUDED 0 0.0000000000 0 0 18 0
210 civil works 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 1025 INCLUDED 0 0.0000000000 0 0 18 0
211 civil works 100001328 995454 18 Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 450 INCLUDED 0 0.0000000000 0 0 18 0
212 civil works 100001329 995454 18 Steel Reinforcement MT 87 INCLUDED 0 0.0000000000 0 0 18 0
213 civil works 100001330 995428 18 Stone filling (40 mm size) for transformer/Reactor foundation M3 20 INCLUDED 0 0.0000000000 0 0 18 0
214 civil works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 12 INCLUDED 0 0.0000000000 0 0 18 0
215 civil works 100001714 995428 18 Stone spreading in switchyard excluding PCC M2 3000 INCLUDED 0 0.0000000000 0 0 18 0
216 civil works 100001713 995424 18 Antiweed treatment M2 6000 INCLUDED 0 0.0000000000 0 0 18 0
217 civil works 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 222 INCLUDED 0 0.0000000000 0 0 18 0
218 civil works 100004507 995421 18 3.75m wide Cement Concrete road with PCC shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and all type concrete shall be paid separately under relevant items M2 188 INCLUDED 0 0.0000000000 0 0 18 0
219 civil works 100001458 995421 18 Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails for Reactor. M2 58 INCLUDED 0 0.0000000000 0 0 18 0
220 civil works 100007701 995462 18 Supplying and erecting dewatering pumps- 2 HP EA 1 INCLUDED 0 0.0000000000 0 0 18 0
221 civil works 100015791 995454 18 All civil works for Drains construction of Section A-A including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 50 INCLUDED 0 0.0000000000 0 0 18 0
222 civil works 100015792 995454 18 All civil works for Drains construction of Section B-B including crossings if any as per technical specification and tender drawingscomplete in all respect with all labour and materials. M 50 INCLUDED 0 0.0000000000 0 0 18 0
223 civil works 100001480 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 4-4 M 50 INCLUDED 0 0.0000000000 0 0 18 0
224 civil works 100001479 995454 18 Cable Trench including all types of crossings, all metallic works and sump pit including concrte and reinforcement steel Section 3-3 M 350 INCLUDED 0 0.0000000000 0 0 18 0
225 civil works 100001712 995428 18 Removing,cleaning and washing of existing stones and respreading of stones in switchyard excluding PCC M2 3000 INCLUDED 0 0.0000000000 0 0 18 0
226 civil works 100001721 995428 18 Supplying, filling and compacting stone boulders mixed with sand under foundations, roads, cable trenches, drains etc in layers notexceeding 250mm thickness including ramming, watering compacting M3 462 INCLUDED 0 0.0000000000 0 0 18 0
227 civil works 100001743 995414 18 PEB - 400 kV GIS - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 160 INCLUDED 0 0.0000000000 0 0 18 0
228 civil works 100004427 995416 18 400 kV PEB AHU Room for GIS Hall - Civil Works All civil works complete as per TS, including - brickwork, finishing (external andinternal), windows etc. However, excavation, concrete (all types) and reinforcement steel shall be measured and paid separately asper respective item of BPS. M2 25 INCLUDED 0 0.0000000000 0 0 18 0
229 civil works 170002803 995473 18 Providing and fixing 100mm UPVC pipes conforming to IS : 15328, for weep holes M 65 INCLUDED 0 0.0000000000 0 0 18 0
230 civil works 100039866 995432 18 Soil Investigation for 02 borehole locations: As per technical specification including all laboratory and field tests, report andrecommendations. LOT 1 INCLUDED 0 0.0000000000 0 0 18 0
231 civil works 100003295 995429 18 Dismantling of RCC in foundation including disposal of debris and reinforcement bars of dismantled RCC works within substationboundaries as per direction of enginner incahrge M3 15 INCLUDED 0 0.0000000000 0 0 18 0
232 civil works 100001392 995455 18 Switchyard Gate excluding Concrete EA 1 INCLUDED 0 0.0000000000 0 0 18 0
233 civil works 100001391 995477 18 New chain Link Fencing excluding concrete M 85 INCLUDED 0 0.0000000000 0 0 18 0
234 civil works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 5 INCLUDED 0 0.0000000000 0 0 18 0
235 civil works 100002911 995432 18 Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 2000 INCLUDED 0 0.0000000000 0 0 18 0
236 civil works 100002583 995432 18 Supply of earth (excluding rock & boulders) at site including royalty, carriage and filling in specified areas in layers notexceeding 200mm in depth, compacting under optimum moisture condition to achieve 95% of Proctor density, finishing etc. allcomplete, for all leads & lifts, with all labour, material, tools, tackles, equipments, safeguards & incidentals as necessary as perdrawings, specification and direction of the Engineer- in- Charge. M3 2000 INCLUDED 0 0.0000000000 0 0 18 0
237 Erection of foundation bolt 100001675 995455 18 Erection of 32mm dia foundation bolts including nuts, checknuts, washers and packplates EA 36 INCLUDED 0 0.0000000000 0 0 18 0
238 Erection of structure 100001216 995455 18 Erection of Pipe Structure - 400 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 3 INCLUDED 0 0.0000000000 0 0 18 0
239 Erection of structure 100001217 995455 18 Erection of Pipe Structure - 400 kV, 1-Phase, BPI, (Excluding Wave Trap), including nuts, bolts, all type of washers,packplates, step bolts and gusset plates excluding foundation bolts EA 6 INCLUDED 0 0.0000000000 0 0 18 0
240 Erection of structure 100001241 995455 18 Erection of Equipment Support (Pipe) Structures to be designed during detailed engineering. MT 5 INCLUDED 0 0.0000000000 0 0 18 0
241 Erection of structure 100001681 995455 18 Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 1 INCLUDED 0 0.0000000000 0 0 18 0
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 4
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(SCHEDULE OF RATES AND PRICES )
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurugram (Haryana) - 122001
Training Charges :
SI. No. PR No Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘…’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Charges Total Charges
Place #REF! Printed Name
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 5
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(SUMMARY OF TAXES & DUTIES not included in Schedule 1 & 3)
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST on Goods 0.00 Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00 Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 5
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurugram (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 6
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(GRAND SUMMARY)
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurugram (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 6 After Discount
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : #REF! Power Grid Corporation of India Ltd.,
Address : #REF! "Saudamini", Plot No.-2
#REF! Sector-29,
#REF! Gurugram (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3
Installation Charges
4 TOTAL SCHEDULE NO. 4
Training Charges
5 TOTAL SCHEDULE NO. 5
Taxes and Duties
6 TOTAL SCHEDULE NO. 7
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5]
Date : Printed Name :
Place : Designation :
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule - 6
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
(GRAND SUMMARY)
JOINT VENTURE OF & To:
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurugram (Haryana) - 122001
Sl. No. Description Total Price (INR) From Sch-6 Discount Factors
1 TOTAL SCHEDULE NO. 1 0.00 0.00 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00 0.00 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00 0.00 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+5]
Date : Printed Name :
Place : Designation :
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Schedule 7
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
JOINT VENTURE OF &
Bidder’s Name and Address (Sole Bidder) : To:
Name : #REF! Contract Services
Address : #REF! Power Grid Corporation of India Ltd.,
#REF! "Saudamini", Plot No.-2
#REF! Sector-29,
Gurgaon (Haryana) - 122001
SL. NO. PR No Line Item No Code HSN of the Equipment /item for which type test is to be conducted Whether HSN in column ‘---’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘---’ is confirmed. If not indicate applicable rate of GST # Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
Date Printed Name
Place Designation
Spec No:CC/NT/W-GIS/DOM/A04/25/12409
400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Letter of Discount
LETTER OF DISCOUNT
Contract Services Schedule 1 0.00
Power Grid Corporation of India Ltd., Schedule 2 0.00
"Saudamini", Plot No.-2 Schedule 3 0.00
Sector-29, (near IFFCO Chowk) Total 0.00
Gurgaon (Haryana) - 122001
Subject : 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch-1 Sch-2 Sch-3
1 Discount on lum-sum basis on total price quoted by us without GST. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4 & Sch-7] In Rs. 0.00 0.00 0.00
2 Discount on percent basis on total price quoted by us without GST. [The discount shall be applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%) 0.00 0.00 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Rs. 0.00
Schedule-3 : Installation Charges In Rs. 0.00
Schedule-4 : Training Charges In Rs.
Schedule-7 : Type Test Charges In Rs.
4 Discount on percent basis on the Schedules as given below : [The discount shall be applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00
Schedule-2 : Local Transportation, In-transit Insurance, loading and unloading In Percent (%) 0.00
Schedule-3 : Installation Charges In Percent (%) 0.00
Schedule-4 : Training Charges In Percent (%)
Schedule-7 : Type Test Charges In Percent (%)
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation. #DIV/0! #DIV/0! #DIV/0! #DIV/0! #REF!
[Discount will not be calculated authometrically. However, the same shall be considered during evaluation.]
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain, 0.00 0.00 0.00
Yours faithfully, 0.00000000 0.00000000 0.00000000 Discount Factors
For and on behalf of
Date : Printed Name : 0.00
Place : Designation : 0.00
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
Spec No:CC/NT/W-GIS/DOM/A04/25/12409 Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
0 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurugram (Haryana) - 122001 13 th
Name of Contract : 400kV GIS Substation Package SS-135 (Re-tender) for (a) Extension of 400kV Pandiabili GIS Substation under ERBS-I. (b) Extension of Rangpo 132kV GIS Substation under ERBS-II (c) Bay Extension of Misa GIS S/s under NERES XXVIII 15 th
Dear Ladies and/or Gentlemen, 16 th
1.0 In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 0/- () or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 17 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. Sole Bidder 23 th
Schedule 4 Training charges for training to be imparted (Not Applicable) 24 th
Schedule 5 Taxes and Duties not included in Schedule 1 & 3 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges (Not Applicable) 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of JOINT VENTURE OF &
Date : Printed Name : 0.00
Place : Designation : 0.00
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Total Ex-Works Price Direct 0.00
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
^ If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under “Direct transaction” by the bidder, then the taxes and duties on such items shall be paid/reimbursed by POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the rates prevailing on date of Bid opening.
Place : Printed Name : --
Total F&I Price (=SUM(I16:I27))
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Total Installaiton Charges #REF!
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Date : (=IF('Sch-1'!B43=0,"", 'Sch-1'!B43)) (="Printed Name : " & IF('Sch-1'!E44=0,"",'Sch-1'!E44))
Place : (=IF('Sch-1'!B44=0,"", 'Sch-1'!B44)) (="Designation : " & IF('Sch-1'!E45=0,"",'Sch-1'!E45))
TOTAL TYPE TEST CHARGES (=SUM(I17:I18))
Date : (='Sch-1'!B43) (="Printed Name : " & 'Sch-1'!E44)
Place : (='Sch-1'!B44) (="Designation : " & 'Sch-1'!E45)
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
#REF! 0.00 #REF! 0.00 #REF!
#REF! #REF! #N/A
#REF! #REF! 0 #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 0 #REF! plus
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 0 1 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 0 #REF!
#REF! #REF! #REF! 0 #REF! #REF! #REF! 0 #REF! 0 0 1 1 #REF!
#REF! 0 1 0 0 #REF!
1 One 1 One 1 One 1 One #REF! 0 1 0 1 #REF!
2 Two 2 Two 2 Two 2 Two #REF! 0 1 1 0 #REF!
3 Three 3 Three 3 Three 3 Three #REF! 0 1 1 1 #REF!
4 Four 4 Four 4 Four 4 Four #REF! 1 0 0 0 #REF!
5 Five 5 Five 5 Five 5 Five #REF! 1 0 0 1 #REF!
6 Six 6 Six 6 Six 6 Six #REF! 1 0 1 0 #REF!
7 Seven 7 Seven 7 Seven 7 Seven #REF! 1 0 1 1 #REF!
8 Eight 8 Eight 8 Eight 8 Eight #REF! 1 1 0 0 #REF!
9 Nine 9 Nine 9 Nine 9 Nine #REF! 1 1 0 1 #REF!
10 Ten 10 Ten 10 Ten 10 Ten #REF! 1 1 1 0 #REF!
11 Eleven 11 Eleven 11 Eleven 11 Eleven #REF! 1 1 1 1 #REF!
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen #REF! 0 0 0 0 #REF! +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen #REF! 0 0 0 1 #REF! /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen #REF! 0 0 1 0 #REF! /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen #REF! 0 0 1 1 #REF!
20 Twenty 20 Twenty 20 Twenty 20 Twenty #REF! 0 1 0 0 #REF!
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One #REF! 0 1 0 1 #REF!
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two #REF! 0 1 1 0 #REF!
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three #REF! 0 1 1 1 #REF!
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four #REF! 1 0 0 0 #REF!
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five #REF! 1 0 0 1 #REF!
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six #REF! 1 0 1 0 #REF!
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven #REF! 1 0 1 1 #REF!
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight #REF! 1 1 0 0 #REF!
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine #REF! 1 1 0 1 #REF!
30 Thirty 30 Thirty 30 Thirty 30 Thirty #REF! 1 1 1 0 #REF!
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One #REF! 1 1 1 1 #REF!
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01_Attachment-8(a)_Manufacturer Authorization Form.docx
docx • 0.03 MB
02a_Attachment-8(b).docx
docx • 0.02 MB
03_Attachment-20_KMP Declaration.doc
doc • 0.03 MB
04_Attachment -3 (QR)_.xlsx
xlsx • 0.19 MB
04_Attachment_21_Affidavit for Self-Certification_PPP-MII_.docx
docx • 0.02 MB
05_Attachment 22_Certificate by Auditor_PPP-MII_.docx
docx • 0.02 MB
06_Attachment-23_Compliance to the process related to the e-RA_.docx
docx • 0.02 MB
07_Attachment-24_Confirmation in regard to Design and Type Test.docx
docx • 0.02 MB
08_Attachment-25_Declaration regarding events encountered_.docx
docx • 0.03 MB
09_Attachment-26_Undertaking by the bidder regarding Compliance of DMI&SP policy.docx
docx • 0.02 MB
10_Attachment 28_Certificate by bidder.docx
docx • 0.02 MB
11_Attachment-29_Bid Securing Declaration.docx
docx • 0.02 MB
12_Attachment-30.docx
docx • 0.03 MB
13_Attachment-31_Decl by the bidder for Code of Integrity for Public procurement.docx
docx • 0.02 MB
14_Attachment-32_Declaration-Supplier Code of Conduct.docx
docx • 0.02 MB
15_Legends for Units.pdf
pdf • 0.03 MB
First_Envelope_and_Bid_Forms.xlsx
xlsx • 2.15 MB
Price_schedule__.xlsx
xlsx • 0.82 MB
PANDIABILI TENDER GA.pdf
pdf • 0.24 MB
PANDIABILI TENDER SLD.pdf
pdf • 0.13 MB
Rangpo GIS-Tender GA.pdf
pdf • 0.36 MB
Rangpo GIS-Tender SLD.pdf
pdf • 0.12 MB
Tender GA 400KV MISA SUBSTATION SHEET 2 OF 2.pdf
pdf • 0.95 MB
Tender GA 400KV MISA SUBSTATION SHEET 1 OF 1.pdf
pdf • 1.38 MB
Tender SLD Misa Ss.pdf
pdf • 0.21 MB
132kV GIS iNterconnection details, Extension done in 2018.pdf
pdf • 0.46 MB
2.132kV GIS layoutpdf.pdf
pdf • 0.33 MB
3.132kV GIS layout plan & section.pdf
pdf • 0.42 MB
5. As built Rangpo132kV foundation cable trench.pdf
pdf • 0.47 MB
Existing GIS foundation and cable trench layout.pdf
pdf • 0.47 MB
Existing Outdoor Earthing layout of Rangpo Ss.pdf
pdf • 0.78 MB
HY803873-A06-01-R2.pdf
pdf • 0.26 MB
O14113-E-IS-SY-GL-1016.pdf
pdf • 3.49 MB
PGCIL-10032074-A06-01_existing GSLD_Pandiabili.pdf
pdf • 2.16 MB
PGCIL-10032074-A11-01_Existing Bus Extn_Mod_Pandiabili.pdf
pdf • 0.15 MB
O14113-E-IS-GB-EL-4001.pdf
pdf • 3.08 MB
O14113-E-IS-SY-CL-1011.pdf
pdf • 2.89 MB
O14113-E-IS-SY-EL-1001.pdf
pdf • 3.79 MB
INDOOR GIS BUILDING CABLE TRENCH-MISA-R1-compressed (1).pdf
pdf • 5.61 MB
LAYOUT PLAN-MISA-R4 (1).pdf
pdf • 1.46 MB
OUTDOOR EARTMAT LAYOUT-MISA-R0_.pdf
pdf • 1.48 MB
Standard details for switchyard barbed wire fencing.pdf
pdf • 0.47 MB
STD DRAIN.pdf
pdf • 2.24 MB
1HYG900012-2_AE_Misa GIS Layout.pdf
pdf • 3.18 MB
Existing SLD-MISA.pdf
pdf • 3.02 MB
SLD_400kV_Misa SS_1.pdf
pdf • 0.27 MB
SLD_400kV_Misa_SS_2.pdf
pdf • 0.35 MB
3.75 m wide bitumen ROAD.pdf
pdf • 0.44 MB
400KV BPI EQUIP. STRUCTURES.pdf
pdf • 0.49 MB
400KV LA EQUIP. STRUCTURES.pdf
pdf • 0.47 MB
7_SWITCHYARD GATE.pdf
pdf • 1.20 MB
CABLE TRENCH & CROSSING DETAILS.pdf
pdf • 0.63 MB
CHAIN LINK FENCING.pdf
pdf • 1.44 MB
CONCRETE ROAD.pdf
pdf • 2.81 MB
foundation bolt 32.pdf
pdf • 0.16 MB
ROAD CULVERT.pdf
pdf • 1.50 MB
16.0-TS-Telecommunication System-Rev 05.pdf
pdf • 7.09 MB
10.0 Section_Switchyard Erection_Rev.10.pdf
pdf • 4.45 MB
13.0 Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
17.0 Section-Switchgear-INST_rev12.pdf
pdf • 0.86 MB
11.0 Structure Rev 7.pdf
pdf • 0.30 MB
12.0 CRP Rev 09.pdf
pdf • 0.37 MB
14.0 PMU TS Rev 01.pdf
pdf • 0.45 MB
15.0 Civil Works Rev 12.pdf
pdf • 0.99 MB
4.0 Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
5.0 Lighting Specification Rev.07.pdf
pdf • 4.29 MB
6.0 Fire Protection Rev 6.pdf
pdf • 1.97 MB
7.0 Air conditioning R4.pdf
pdf • 0.04 MB
8.0 LT Switchgear R5.pdf
pdf • 0.47 MB
9.0 PLCC R5.pdf
pdf • 0.06 MB
1.0 GTR Rev 15 .pdf
pdf • 7.12 MB
2.0 GIS Rev-5A.pdf
pdf • 1.95 MB
3.0 Section-Switchgear-SA_Rev13.pdf
pdf • 0.87 MB
Annexure-III_Specific Requirement_Rev 10 - FINAL.pdf
pdf • 9.19 MB
Annexure I-List of drawing.pdf
pdf • 0.16 MB
Annexure II- Mandatory spares breakup.pdf
pdf • 0.29 MB
ANNEXURE IV GIS module description.pdf
pdf • 0.17 MB
Annexure V-Technical specification of PCC.pdf
pdf • 0.14 MB
Annexure VI Annexure S1 revised.pdf
pdf • 0.10 MB
ANNEXURE VII_GIS module description_Pandiabili & Rangpo.pdf
pdf • 0.24 MB
Section-Project SS-135(Rev01).pdf
pdf • 0.69 MB
00_Cover Pages.doc
doc • 2.33 MB
01_Main Index_Vol-I.doc
doc • 0.02 MB
02-Section - I IFB SSTE_Vol-I_.docx
docx • 0.04 MB
03_ Section - II ITB SSTE S&I DCB-PRANIT_Vol-I.docx
docx • 0.10 MB
04- Section-III-BDS.docx
docx • 0.09 MB
04-Annexure-A (BDS)_.doc
doc • 0.10 MB
04-Annexure-B to BDS.docx
docx • 0.02 MB
04-Annexure-C (BDS) - MJunction_.docx
docx • 0.03 MB
04-Annexure-C (BDS) - PRANIT_.docx
docx • 0.03 MB
05-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
06- Section-V-SCC (GIS).docx
docx • 0.09 MB
07- Appendix-I to SCC.docx
docx • 0.03 MB
08-Section - VI Forms and Proceedures__.doc
doc • 0.62 MB
Letter to the Bidders_.docx
docx • 0.19 MB
OBD_EXTN-IX__.docx
docx • 0.17 MB
Letter to the Bidders_.docx
docx • 0.16 MB
OBD_EXTN-VIII_.docx
docx • 0.16 MB
OBD_EXTN-VII_.docx
docx • 0.17 MB
Amendment No VI.docx
docx • 0.05 MB
OBD_EXTN-VI.docx
docx • 0.17 MB
OBD_EXTN-V.docx
docx • 0.17 MB
OBD_EXTN-IV_LETTER_.docx
docx • 0.17 MB
First Envelope and Bid Forms_rev01 .xlsx
xlsx • 2.15 MB
OBD_EXTN-III_LETTER.docx
docx • 0.17 MB
Amendment No-IV.docx
docx • 0.03 MB
Amendment No-III.docx
docx • 0.03 MB
OBD_EXTN-II_LETTER.docx
docx • 0.16 MB
OBD_EXTN-I_LETTER.docx
docx • 0.16 MB
06_Price_schedule_Rev01.xlsx
xlsx • 0.82 MB
Amendment No I.doc
doc • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .