KIRAN KUMAR
CHIEF ENGINEER
VIDYUT BHAWAN III
KIRAN KUMAR
CHIEF ENGINEER
Turn Key Contract for Installation, Erection, Testing and Commissioning of 1*10 MVA new additional Power Transformer at 33/11 KV Power Sub-Station, Motipur along with associated 11 KV dedicated feeder for Bariarpur Industrial Area, BIADA under Electric Supply Division- Muzaffarpur (West), NBPDCL under Deposit Head Scheme.
135173
37/PR/NBPDCL/2026
Open Tender
ELECTRICAL
Muzaffarpur
• Name of the Bidder/ Manufacturer
• Address & contact no of the Bidder/ Manufacturer
• Pan No
• GST No
• Electrical contractor's License Class A ( Give registration N o., Validity and details)
• Cost of Tender( Required amount - Rs. 100000+18% GST Give details of amount and online receipt no.)
• Bid Security (Earnest Money Amount )- shall be valid for One Eighty (180) days beyond the original validity period of the bid ( Give details of amount, validity and BG Detail)
ELECTRICAL
ITEM RATE
L1
1
48 documents required · 48 mandatory
₹1.2 L
Processing Fee: 11800
₹9.8 L
In the office chamber of Chief Engineer (O&M) NBPDCL. 04th floor, VidyutBhawan-3 Bailey Road, Patna.
10 Aug 2026
6 Jul 2026
11 Aug 2026
15 Jul 2026
10 Aug 2026
15 Jul 2026
20 Jul 2026
NIT No: 37/PR/NBPDCL/2026
TECHNICAL & COMMERCIAL PART (Part-I)
Name of Utility :- NORTH BIHAR POWER DISTRIBUTION COMPANY LIMITED
Name of Department :- Department of O&M
NIT No :- NIT No: 37/PR/NBPDCL/2026
Name of Scheme :- Turnkey Contract for Installation, Erection, Testing and Commissioning of 1*10 MVA new additional Power Transformer at 33/11 KV Power Sub-Station, Motipur along with associated 11 KV dedicated feeder for Bariarpur Industrial Area, BIADA under Electric Supply Division- Muzaffarpur (West), NBPDCL under Deposit Head Scheme.
Estimated Cost (in Rs) :- ₹ 49,050,260.00
Bid Security (Earnest Money Deposit) (in Rs) :- ₹ 981,005.00
Time of Completion (in months) :- Six (06) months from the effective date of the LOA/NOA
Cost of BOQ (in Rs.) :- Rs 1,00,000+18% GST
Processing fee for BSEDC (in Rs.) :- As per Actual
Sl No. Details To be Filled in green color cells by Contractor [Submit- YES/NO from Sl. No. 5 onwards] Page No [Page numbered document details] Remarks (If any)
1 Name of the Bidder/ Manufacturer :- From To
2 Address & contact no of the Bidder/ Manufacturer :-
3 Electrical contractor's License Class A ( Give registration No., Validity and details) ( Document submitted Yes/ No with page no.) :-
4 Cost of Tender( Required amount - Rs. 100000+18%GST Give details of amount and online receipt no. ( Document submitted Yes/ No with page no.) :-
5 Attachment 1 : Bid Security (Earnest Money Amount )- shall be valid for ninety(90) days beyond the original validity period of the bid ( Give details of amount, validity and BG Detail) Document submitted Yes/ No with page no.) :-
6 Bid Validity - upto and including 180 days reckoned from the deadline for Submission of Bids (Self declaration to be submitted by the bidder) :-
7 Details of Joint Venture (If any) as per requirement of RFP/NIT. :-
8 Form 1 Letter of Bid – Technical Part
9 Form 2 Format for Bidder Information Sheet
10 Form 3B Format of Bank Guarantee for Bid Security
11 Form 4 Format of Power of Attorney of designated Bid Signatory by sole bidder/ lead joint venture member
12 Form 5 Format of Declaration of conformance of the Bidder and the Facilities offered, to the specified eligibility requirement
13 Form 6 Format for Affidavit of Self certification regarding Local Content in line with PPP-MII order and #MoP Order/DoT order
14 Form 7 Format of Power of Attorney by Each Member/ Partner of The Joint Venture in favor of Lead Member/ Partner
15 Form 8 Format of Joint Deed of Undertaking by the Joint Venture Partners/ Members
16 Form 9 Format for Details/ Data and Documentary Evidence in support of meeting the Qualification Requirement
17 Form 10 Format of Bought-out & Sub-contracted Items
18 Form 11 Format of Undertaking on Compliance of Terms & Conditions of the Bidding Documents including Scope of Work and other related requirements
19 Form 12 Format of Alternative, Deviations and Exceptions to the Provisions of RFB Document
20 Form 13 Format of Work Completion Schedule
21 Form 14 Format of Guarantee Declaration
22 Form 15 Format of Information regarding Ex-employees
23 Form 16 Format for Price Adjustment Data
24 Form 17 Format of Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises
25 Form 18 FORMAT OF Declaration for tax exemptions, reductions, allowances or benefits)
26 Form 19 Format of Bank Guarantee verification Check list
27 Attachment-4A : List of Special Maintenance Tools & Tackles included in bid price
28 Attachment-4B : List of Special Maintenance Tools & Tackles not included in bid price
29 Form 20 Format of Additional Information
30 Form 21 Format of Integrity Pact
31 A certificate from banker (as per specified format) indicating various fund-based limits sanctioned to the bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. 16. FORMAT FOR EVIDENCE OF ACCESS TO OR AVAILABILITY OF CREDIT/FACILITIES - BANK CERTIFICATE
32 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid
33 Certificate from Chartered Accountants as per 20 FORM OF CERTIFICATE OF FINANCIAL PARAMETERS FOR QR (as per clause ref. no. 2 of Section 2 of Part 1))
34 Experience certificate to claim eligibility of bidder as per requirement of RFP/NIT. Work experiences of the bidder as per above shall be considered only if the works have been executed under Govt./Semi-Govt./autonomous body of Central/State Govt./Electricity Power Utility/ Power Deptt. in India only. :-
35 Liquid Asset(Rs in Cr.) (10 % of estimated cost of project ) :-
36 Net Worth of the bidder (must be positive for the each of the last three Financial Years) :-
37 MAAT (Rs. In Cr.) (30 % of estimated cost of project taken for best three years out of last five financial years ) :-
38 Bid Capacity :-
42 Minimum Manpower as per RFP( Yes/No) :-
43 Self-certified copy of the document to establish legal status of the firm viz. Certificate of Incorporation issued under The Companies Act / The Limited Liability Partnership Act / Partnership deed etc. as applicable :-
44 Copy of memorandum of association/article of association
45 Notarized affidavit to be submitted with regard to Sanction , Suspension and Prohibition as defined in RFP clause 1.3 of part -1 ( Bidding Procedure & Requirements )
46 Notarized affidavit to be submitted with regard to Non-debarrment of the firm by BSPHCL or any of its subsidiary companies i.e NBPDCL , SBPDCL , BSPGCL , BSPTCL participating in the bid either in individual capacity or in JV or by forming consortium as on the date of submission of bid .
47 Authority to seek references from banker: :-
Turnkey Contract for Installation, Erection, Testing and Commissioning of 1*10 MVA new additional Power Transformer at 33/11 KV Power Sub-Station, Motipur along with associated 11 KV dedicated feeder for Bariarpur Industrial Area, BIADA under Electric Supply Division- Muzaffarpur (West), NBPDCL under Deposit Head Scheme.
NIT No:- 37/PR/NBPDCL/2026
Sl. No Description of Work Unit Scope of Work
A Installation of additional 10 MVA Power Transformer No. 1
B 11 KV Bay Extension No. 1
C 11 KV Line with 3 core, 300 sqmm XLPE Cable (Double Ckt) Double CKm 4
D 11 KV Line with ACSR Dog Conductor on Rail Pole Km 3
Turnkey Contract for Installation, Erection, Testing and Commissioning of 1*10 MVA new additional Power Transformer at 33/11 KV Power Sub-Station, Motipur along with associated 11 KV dedicated feeder for Bariarpur Industrial Area, BIADA under Electric Supply Division- Muzaffarpur (West), NBPDCL under Deposit Head Scheme.
NIT No-: 37/PR/NBPDCL/2026
(Schedule: 1- Price for Supply)
Name of Bidder:
Sl. No. Description Unit Unit Quantity Total Quantity Unit Ex-Work Price excluding GST Unit Frieght Price Unit Insurance Price Total Ex-work with F&I Price excluding GST
A Installation of additional 10 MVA Power Transformer No. 1
1 33/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type Power Transformer along with transformer oil, Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank, oil level indicator, valves, 2 sets of 50x8 mm GS Neutral Earthing strips {(with braided conductor on bushing end), isolating link, isolation with insulators}, Vent explosion plug, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, LV/HV bushing etc as required as per technical specifications, approved drawings and scope of the work.
a 10 MVA Power Transformer No 1 1 0.00
2 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 36kV, 1-Phase, 800-400-200 Amps/1-1-1 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), Jumpers, earthing, supporting structures, bi-metallic clamps, permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings Set 1 1 0.00
3 33kV, Indoor, Control & Relay panel along with E/F & O/C relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling:
a Power transformer 33 kV VCB with Modem compatible DLMS Complaint Class A Static Tri-Vector Energy Meter and differential relays No 1 1 0.00
4 36 kV, 3-pole, 1-Phase, 33kV/110 volt, Single core outdoor type Potential Transformer along with junction box (1 no junction box for 3 no of 1-phase PTs), bi-metallic clamp and required accessories etc., complete as per technical specifications, approved drawings and scope of the works. Set 1 1 0.00
5 36kV, 800 A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR) with or without Earth Switch, Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings Set 2 2 0.00
6 12kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 12kV, 1-Phase, 600-300-150/5-5 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), Jumpers, earthing, supporting structures, bi-metallic clamps, permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings No 1 1 0.00
7 11 kV, Indoor, Control & Relay panel along with E/F & O/C relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling:
a 11 kV feeder VCB with Modem compatible DLMS Complaint Class A Static Tri-Vector Energy Meter and differential relays. No 1 1 0.00
8 12 KV, 1 Phase, 11 kV/110 Volts, 1 core Potential Transformer, Outdioor type along with terminal connector, junction box and required accessories complete (1set=3 nos.) Set 1 1 0.00
9 12 kV, 630 A, 25kA for 3 seconds, 3-ph double break centre rotating type (DBCR) with or without Earth Switch, Gang Operated Isolator along with Support Insulators, Operating Mechanism, Base Channel, down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings No 2 2 0.00
10 Bus-Bars & Jumpers/Droppers/Terminations including hardware fittings, hardware, T-connector etc as per technical specifications, approved drawings and scope of works.
a ACSR Zebra Conductors Km 0.1 0.1 0.00
b IPS Aluminium Pipes 65 mm Dia Km 0.05 0.05 0.00
11 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 set= 3 Nos.), jumpering from bus bar, hardware etc as required as per technical specifications, approved drawings and scope of the works. Set 1 1 0.00
12 33 KV Post Insulator (1 Set = 2 Nos of 22 KV) Set 6 6 0.00
13 33 KV Disc Insulator Insulator (1 Set = 4 Nos Disc Insulator 90 KN) along with Hardware fitting (B & S Type) Set 6 6 0.00
14 Gantry structures made of Lattice structures of equal angles sections, flat as per approved drawings. All structural steel members and bolts shall be galvanized after fabrication as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members. All L45x45x5 will have 23 mm back mark. All L50x50x6 will have 28mm back mark. 3.5mm spring washers are to be used under each nut, structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise. All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 as per technical specifications, scope of works and approved drawings.. MT 4.5 4.5 0.00
15 40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover, placed on GI frame, bantonide powder and other accessories complete as per technical specification. (For treated earthing) Set 6 6 0.00
16 Earthing & Grounding of structure & equipment with all required accesories as per approved Electrical Layout for each bay (75 X8mm MS Flat-0.25 MT, 50X6mm GS Flat-0.25 MT, 25 mm Dia MS Rod 3 Meter long-0.1 MT) Lot per Transformer 1 1 0.00
17 All types control cable (4C/6C/12C x 2.5 Sqmm Copper as per TS) and LT power cable (16 Sqmm) required for the successful commissioning and charging of additional 10 MVA Power Transformer in sub-station as per TS, scope of work and direction of Engineer in Charge. Lot per Transformer 1 1 0.00
B 11 KV Outdoor Bay Extension No. 1
1 Gantry structures made of Lattice structures of equal angles sections, flat as per approved drawings. All structural steel members and bolts shall be galvanized after fabrication as per IS:4759 and zinc coating shall not be less than 610gm/sq. meter for all structural steel members. All L45x45x5 will have 23 mm back mark. All L50x50x6 will have 28mm back mark. 3.5mm spring washers are to be used under each nut, structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise. All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 as per technical specifications, scope of works and approved drawings. MT 2.5 2.5 0.00
2 12kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 12kV, 1-Phase, 600-300-150/5-5 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), Jumpers, earthing, supporting structures, bi-metallic clamps, permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings No 1 1 0.00
3 11 kV, Indoor, Control & Relay panel along with E/F & O/C relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling:
a 11 kV feeder VCB with Modem compatible DLMS Complaint Class A Static Tri-Vector Energy Meter No 1 1 0.00
4 12 KV, 1 Phase, 11 kV/110 Volts, 1 core Potential Transformer, Outdoor type along with terminal connector, junction box and required accessories complete (1set=3 nos.) Set 1 1 0.00
5 12kV, 630 A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated, with earth switch isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings. Set 1 1 0.00
6 ACSR Conductor for Bus-Bars & Jumpers/Droppers/Terminations including hardware fittings, hardware, T-connector etc as per technical specifications, approved drawings and scope of works.
a ACSR Zebra Conductors km 0.075 0.075 0.00
7 All types control cable and LT power cable required for the successful commissioning and charging of bays in sub-station as per TS, scope of work and direction of Engineer in Charge. Lot per Bay 1 1 0.00
8 9 kV, 10kA, 1-ph Station Class Lightening Arrester, jumpering from bus bar, hardware etc as required as per technical specifications, approved drawings and scope of the works. (1 Set=3 Nos) Set 1 1 0.00
9 11 Porcelain Insulator - Pin, Post and Disc insulators along with suitable hardware & accessories suitable for ACSR Zebra conductors as per approved drawings & specifications. Lot per Bay 1 1 0.00
10 IPS Aluminium Pipe 65 mm. dia. As per Technical Specification and scope of work Mtr. 15 15 0.00
11 Earthing & Grounding of structure & equipment with all required accesories as per approved Electrical Layout for each bay (75 X8mm MS Flat-0.25 MT, 50X6mm GS Flat-0.25 MT, 25 mm Dia MS Rod 3 Meter long-0.1 MT) LS Per bay 1 1 0.00
12 40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover, placed on GI frame, bantonide powder and other accessories complete as per technical specification. (For treated earthing) Set 3 3 0.00
C 11 KV Line with 3 core, 300 sqmm XLPE Cable (Double Ckt) Double CKm 4
1 11 KV grade XLPE, 3 core, 300 sqmm size power cable as per TS Km 2 8 0.00
2 GI /CI Pipe 150 mm dia (Light guage) with U-clamps and nuts for raising of cable over DP structure Mtr 60 240 0.00
3 HDPE pipe 160 mm Dia as per TS to be laid for underground 11 KV cable Mtr 1800 7200 0.00
4 Outdoor type heat shrinkable termination kit complete with all accessories including lugs suitable for 3 Core 300 Sqmm 11 kV grade Al conductor XLPE cable as per TS [1 Set = termination Kit Suitable for terminating each 3 Core of Cables] Set 10 40 0.00
5 Outdoor type heat shrinkable Jointing kit complete with all accessories including lugs suitable for 3 Core 300 Sqmm 11 kV grade Al conductor XLPE cable as per TS. [1 Set = Jointing Kit Suitable for jointing each 3 Core of Cables] Set 2 8 0.00
6 13 meter long, 60 KG per meter Rail Pole along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base as per Technical Specification and approved drawing. No 5 20 0.00
7 Galvanized Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp etc made of GI Channels, GI angle, GI flats for over head structures as per technical specification, approved drawings and scope of work. MT 0.35 1.4 0.00
8 GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. MT 0.0187 0.0747 0.00
9 40 mm dia., 3000 mm long GI pipe earth electrode with all associated accessories complete for untreated earthing Set 5 20 0.00
10 9 KV 5 KA Distribution Class Lightening Arrester as per technical specification, approved drawings and scope of work. [1 Set=3 Nos] Set 2 8 0.00
11 Supply of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method along with suitable clamps & nut boltson Double pole structure as per relevant applicable standard. No 2.5 10 0.00
D 11 KV Line with ACSR Dog Conductor on 13 M long Rail Pole CKm 3
1 13 Meter long, 60 Kg per meter Rail Pole along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base as per Technical Specification and approved drawing. No 24 72 0.00
2 Galvanized Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp etc made of GI Channels, GI angle, GI flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. MT 0.72 2.160 0.00
3 GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. MT 0.048 0.144 0.00
4 Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 No.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work. set 8 24 0.00
5 Insulator and hardware as per technical specification, approved drawings and scope of work.
a 11 kV 45 KN Polymer Disc insulator with strain hardware set 12 36 0.00
b 11 kV Polymer Pin insulator with complete set of fittings (1 Set= 1 No PIN with Hardware Fitting) set 66 198 0.00
6 Earthing arrangement as per technical specificatons, approved drawings and scope of work.
a 40 mm dia., 3000 mm long GI pipe earth electrode with all associated accessories complete for untreated earthing. set 2 6 0.00
b 8 SWG GI Coil 115 turns (1.85 kg) as per Technical Specification for untreated earthing . No 20 60 0.00
7 ACSR Dog Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamps/connectors, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work km 3.09 9.27 0.00
8 Guarding of 3 phase 11 kV line using new GI wire and earthing as per technical specification, approved drawings and scope of work.
a 7/16 SWG for Guarding MT 0.013 0.039 0.00
b 8 SWG for Lacing MT 0.004 0.012 0.00
9 Supply of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts on Double pole structure as per relevant applicable standard. No 2 6 0.00
Grand Total 0.00
Turnkey Contract for Installation, Erection, Testing and Commissioning of 1*10 MVA new additional Power Transformer at 33/11 KV Power Sub-Station, Motipur along with associated 11 KV dedicated feeder for Bariarpur Industrial Area, BIADA under Electric Supply Division- Muzaffarpur (West), NBPDCL under Deposit Head Scheme.
NIT No-: 37/PR/NBPDCL/2026
(Schedule: 2- Price for Erection/Installation)
Name of Bidder: 0.00
Sl. No. Description Unit Unit Quantity Total Quantity Unit Erection Price exclusive of GST Total Erection Price exclusive of GST
A Installation of additional 10 MVA Power Transformer Nos 1
1 Survey of Existing Power Sub Station, Preparation of Single Line Diagram and obtaining approval of Engineer-in-Charge as per Technical Specification Scope of Work and Direction of Engineer-in-Charge Lot per Transformer 1 1 0.00
2 Design, engineering and construction of foundation (civil work) for following 10 MVA Departmental Power Transformer considering original equipment manufacturer recommendations including excavation of pit, shuttering, reinforcement, cement concreting including providing and erecting guiding rail, wheel stopper etc as per Technical Specification, approved Drawing, Scope of works and direction of Engineer in Charge: [The Foundation footing should be at least 1.5 Meter below Natural Ground level] Nos 1 1 0.00
3 Design, engineering and construction of cement concrete Cable Trench of 0.75 Mtr wide, 1.0 Mtr. depth, precast RCC Trench Cover, Water slop, cable supporting angles including Labour, Reinforcement Steel, GI angles, Flats, Steel Frame Work, Excavation etc, all complete as per Technical Specification, approved Drawing & Scope of works. [Payment shall be made as per actual] [The Foundation footing should be at least 1.5 Meter below Natural Ground level] R/Mtr 15 15 0.00
4 Antiweded treatment and stone spreading in switchyard area excluding road, Cable trench, Drainage etc (Stone Spreading 6 inches over 4 inches lean cement concrete layer on brick soling as per technical specification, approved desgn and drawing and as per directon of Engineer in Charge. (payment will be made as per actual requirement per Square meter) CMT 100 100 0.00
5 Erection, filtration, testing and commissioning of 33/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type 10 MVA Power Transformer along with transformer oil, Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank, oil level indicator, valves by providing 2 sets of 50x8 mm GS Neutral Earthing strips with braided conductor on bushing end supported with insulators, OTI & WTI Indicators, Vent explosion plug, control wiring / cabling, cable supporting tray on the body, transformer wheels, bushing etc as per Technical Specification, approved Drawing & all type of related Scope of works. No 1 1 0.00
6 Design, Engineering, erection, testing and commissioning of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 36kV, 1-Phase, 800-400-200 Amps/1-1-1 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs)], Jumpers, earthing, supporting structures, maintenance platform, marshalling box, control & Power cabling between VCB and indoor control panel and required accessories complete as per approved drawings, technical specifications and direction of Engineer in Charge and scope of the work including all type of civil works like plinth, footing, etc as per approved drawings. Set 1 1 0.00
7 Design, Engineering providing and installation of ISMC 75 channel on top of indoor trench, erection of panels on ISMC 75 channels, welding, testing and commissioning of 33kV indoor Control & Relay panel along with E/F & O/C relays, control and power supply cabling in trench between field equipment and panels, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, technical specifications and scope of the work including all type of civil works as per approved drawings. Set 1 1 0.00
8 Excavation, erection, cement concrete foundation, testing and commissioning of all type of lattice structures i.e. Gantry/Swing bus/isolator/CT/PT/PI/S.S.T structures etc. made of joist / channel / angle / flat of different sections by providing and using Foundation Bolts, Nuts, Bolts, Washers etc as per approved drawings and direction of Engineer in Charge complete in all respect. MT 4.5 4.5 0.00
9 Erection, testing and commissioning of 36kV, 800A, 25kA for 3 sec, 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per approved drawings, technical specifications and scope of the work including all type of civil works as per approved drawing including all type of civil works as per approved drawings. (With or Without Earth Switch) Set 2 2 0.00
10 Erection, testing and Commissioning of 30kV, 10kA, 1-ph Station Class Lightening Arresters, jumpering from bus bar, hardware etc as required, as per approved drawings, technical specifications and scope of the work, (1 Set=3 Nos) Set 1 1 0.00
11 Erection, testing and Commissioning of 36 kV, 1-Phase, 33kV/110 volt, Single core outdoor type Potential transformer along with junction box (1 no junction box for 3 no of 1-phase PTs) including control and power supply cabling and required accessories etc., complete as per as per approved drawings, technical specifications and scope of the work. Set 1 1 0.00
12 Erection, testing and commissioning of 12kV, 630A, 25kA for 3 sec, 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per approved drawings, technical specifications and scope of the work including all type of civil works as per approved drawings. (With or Without Earth Switch) Set 2 2 0.00
13 Design, Engineering, erection, testing and commissioning of 12kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 12kV, 1-Phase, 600-300-150 Amps/5-5 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs)], Jumpers, earthing, supporting structures, maintenance platform, marshalling box, control & Power cabling between VCB and indoor control panel and required accessories complete as per approved drawings, technical specifications and direction of Engineer in Charge and scope of the work including all type of civil works like plinth, footing, etc as per approved drawings. Set 1 1 0.00
14 Design, Engineering providing and installation of ISMC 75 channel on top of indoor trench, erection of panels on ISMC 75 channels, welding, testing and commissioning of 11kV indoor Control & Relay panel along with E/F & O/C relays, control and power supply cabling in trench between field equipment and panels, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, technical specifications and scope of the work including all type of civil works as per approved drawings. Set 1 1 0.00
15 Erection, testing and commissioning of Bus Bar with ACSR Zebra Conductor & Al Pipes including jumpers to various equipment using 11 KV and 33 KV insulators, GI Pin, GI Hardware fittings, PG Clamps, T-connectors etc as required as per approved drawings, specifications and scope of the work as per requirement. Lot per Transformer 1 1 0.00
16 Excavation, erection, testing and commissioning of 40 mm dia, 3000 mm long GI pipe earth electrode by providing test link, RCC pit, RCC cover, placed on GI frame, bentonite powder and other accessories complete as per approved drawings, technical specifications and scope of the work for power transformer neutral, station transformer neutral, lightening arresters direct earthing. Set 6 6 0.00
17 Erection, testing and Commissioning of 12 kV, 1-Phase, 11 KV/110 volt, Single core outdoor type Potential transformer along with junction box (1 no junction box for 3 no of 1-phase PTs) including control and power supply cabling and required accessories etc, complete as per as per approved drawings, technical specifications and scope of the work including all type of civil works as per approved drawings. Set 1 1 0.00
18 Laying, testing and commissioning of Power Cables in cable and Control Cables in trench/pipes/underground/overhead laying including their termination at indoor/outdoor terminals including supply of glands, lugs, cable ties, tagging etc as required as per Technical Specification, approved Drawing & Scope of works Lot per Transformer 1 1 0.00
B 11 KV Outdoor Bay Extension Nos 1
1 Design, engineering and construction of cement concrete Cable Trench of 0.75 Mtr wide, 1.0 Mtr. depth, precast RCC Trench Cover, Water slop, cable supporting angles including Labour, Reinforcement Steel, GI angles, Flats, Steel Frame Work, Excavation etc, all complete as per Technical Specification, approved Drawing & Scope of works. [Payment shall be made as per actual] R/Mtr 15 15 0.00
2 Antiweded treatment and stone spreading in switchyard area excluding road, Cable trench, Drainage etc (Stone Spreading 6 inches over 4 inches lean cement concrete layer as per technical specification, approved design and drawing and as per directon of Engineer in Charge. (payment will be made as per actual requirement per Square meter) Sq. m 100 100 0.00
3 Excavation, erection, cement concrete foundation, testing and commissioning of all type of lattice structures i.e. Gantry/Swing bus/isolator/CT/PT/PI etc. made of joist / channel / angle / flat of different sections by providing and using Foundation Bolts, Nuts, Bolts, Washers etc as per approved drawings and direction of Engineer in Charge complete in all respect. MT 2.5 2.5 0.00
4 Design, Engineering, erection, testing and commissioning of 12kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 12kV, 1-Phase, 600-300-150 Amps/5-5 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs)], Jumpers, earthing, supporting structures, maintenance platform, marshalling box, control & Power cabling between VCB and indoor control panel and required accessories complete as per approved drawings, technical specifications and direction of Engineer in Charge and scope of the work including all type of civil works like plinth, footing, etc as per approved drawings. Nos 1 1 0.00
5 Design, Engineering providing and installation of ISMC 75 channel on top of indoor trench, erection of panels on ISMC 75 channels, welding, testing and commissioning of 11kV indoor Control & Relay panel along with E/F & O/C relays, control and power supply cabling in trench between field equipment and panels, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, technical specifications and scope of the work for controlling. [ 11 kV C&R Panel (without diffirential relays) and DLMS Trivector Static Energy Meter complete ] Set 1 1 0.00
6 Erection, testing and Commissioning of 12 kV, 1-Phase, 11 KV/110 volt, Single core outdoor type Potential transformer along with junction box (1 no junction box for 3 no of 1-phase PTs) including control and power supply cabling and required accessories etc, complete as per as per approved drawings, technical specifications and scope of the work including all type of civil works as per approved drawings. Set 1 1 0.00
7 Excavation, laying, welding, refilling, earthing & grounding of MS Flat as per Approved drawing and erection of riser up to various equipment/structures as per scope of the work, specifications and approved drawings, LS per bay 1 1 0.00
8 Excavation, erection, testing and commissioning of 40 mm dia, 3000 mm long GI pipe earth electrode by providing test link, RCC pit, RCC cover, placed on GI frame, bentonite powder and other accessories complete as per approved drawings, technical specifications and scope of the work for power transformer neutral, station transformer neutral, lightening arresters direct earthing. Set 3 3 0.00
9 Erection, testing and commissioning of 12kV, 630A, 25kA for 3 sec, 3-ph double break center rotating type (DBCR), Gang Operated, with or without earth switch isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per approved drawings, technical specifications and scope of the work, Set 1 1 0.00
10 Erection, testing and Commissioning of 9 kV, 10kA, 1-ph Station Class Lightening Arresters, jumpering from bus bar, hardware etc as required, as per approved drawings, technical specifications and scope of the work, (1 Set=3 Nos) Set 1 1 0.00
11 Erection, testing and commissioning of Bus Bar, jumpering and Dropper (Using Al Pipes/Zebra Conductor), by using all types of insulators, clamps and connectors, Al tape etc. with all accessories complete in all respect. LS Per Bay 1 1 0.00
C 11 KV Line with 3 core, 300 sqmm XLPE Cable (Double Ckt) Double CKM 4
1 Earth digging by horizontal Directional Drilling (HDD) method,Laying, termination/jointing, Erection, Testing & commissioning of 11 KV grade 3-core 300 Sqmm XLPE power cable underground using HDPE pipe complete in all respect along with all accessories, earthing etc. and as per TS/approved drawing .Route Markers: providing and using of Route markers made out of 100mm X 5mm GI/ aluminium plate welded / bolted on 35mm X 35mm X 6mm angle iron, 60cm long has to be provided along the Cable (on each 25Meters) shall be provided as per direction of Engineer in charge. Double Circuit/ Meter 900 3600 0.00
2 Erection, Testing & commissioning of 11 KV grade 3-core 300 Sqmm XLPE power underground cable using GI pipe 150mm dia with Holding Clamps , for drain Crossing, Road Crossing & rising on the D.P structure, etc & looping of cable using brick & sand as per approved drawing. Meter 100 400 0.00
3 Erection of following types of poles (DP structrues) for 11 KV Underground line by providing and installing danger plate, anti-climbing devices (barbed wire), earthing material (coil and 8SWG GI wire), red oxide & aluminium paint, pole numbering including Excavation of Pole Pit (of depth 1/6th of pole length), cement concrete foundation using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) with top muffing etc (0.65 cmt/pole) as per scope of work, approved drawings and specifications:
a 13 m long 60 kg per meter Rail Pole along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base as per Technical Specification and approved drawing. No 5 20 0.00
4 Erection, testing & commissioning of Galvanized pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GI Channels, GI angle, GI flats of given sizes for over head structures and GI nuts, bolts & washers as per technical specification, approved drawings and scope of work. Mt 0.35 1.4 0.00
5 Erection, testing and Commissioning of 9 kV, 10kA, 1-ph Distribution Class Lightening Arresters, jumpering, hardware etc as required, as per approved drawings, technical specifications and scope of the work, (1 Set=3 Nos) Set 2 8 0.00
6 Excavation, erection, testing & commissioning of 40 mm dia., 3000 mm long GI pipe earth electrode with all associated accessories complete for untreated earthing Set 5 20 0.00
7 Erection of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts on Double pole structure as per relevant applicable standard and scope of work and approved drawings. No. 2.5 10 0.00
D 11 KV Line with ACSR Dog Conductor on 13 M long Rail Pole CKM 3
1 Survey, route alignment & pole spotting, preparation of survey report . CKm 1 3 0.00
2 Erection of following types of poles (SP/DP/TP/FP structrues) for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire) with clamps, earthing material (using coil/pipe and providing and using 8SWG GI wire), red oxide & aluminium paint, pole numbering including Excavation of Pole Pit (of depth 1/6th of pole length), cement concrete foundation [For Rail Poles and Joist Poles] using cement concreting foundation 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) with top muffing (0.65 cmt/pole) as per scope of work, approved drawings and technical specifications:
a 13 m long, 60 Kg per meter Rail Pole along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base as per Technical Specification and approved drawing. No 24 72 0.00
3 Erection, testing & commissioning of Galvanized pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GI Channels, GI angle, GI flats of given sizes for over head structures and GI nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. MT 0.72 2.160 0.00
4 Earthing arrangement as per technical specificatons, approved drawings and scope of work.
a Excavation, erection, testing & commissioning of 40 mm dia., 3000 mm long GI pipe earth electrode with all associated accessories complete for untreated earthing Set 2 6 0.00
b Erection of 8 SWG GI Coil 115 turns (1.85 kg) with all associated accessories complete in all respect for untreated earthing. No 20 60 0.00
5 Erection of complete stay set along with excavation of Stay pit with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. Set 8 24 0.00
6 Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work.
a 11 kV Polymer Pin insulator with complete set of fittings Set 66 198 0.00
b 11 kV 45 KN Polymer Disc insulator with strain hardware Set 12 36 0.00
7 Stringing, testing and commissioning of ACSR Dog Conductor including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications Ckm 1 3 0.00
8 Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work.
a 7/16 SWG for Guarding MT 0.013 0.039 0.00
b 8 SWG for Lacing MT 0.004 0.012 0.00
9 Erection of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts on Double pole structure as per relevant applicable standard and scope of work and approved drawings. No 2 6 0.00
Grand Total 0.00
Turnkey Contract for Installation, Erection, Testing and Commissioning of 1*10 MVA new additional Power Transformer at 33/11 KV Power Sub-Station, Motipur along with associated 11 KV dedicated feeder for Bariarpur Industrial Area, BIADA under Electric Supply Division- Muzaffarpur (West), NBPDCL under Deposit Head Scheme.
NIT No-: 37/PR/NBPDCL/2026
(GRAND SUMMARY)
Bidder's Name and Address: 0.00
Sl. No. Description Cost
1 TOTAL SCHEDULE NO. 1: Ex Works Price with F&I of Materials
a Total Ex-works Price exclusive of GST 0.00
2 TOTAL SCHEDULE NO.2 : Installation / Erection Charges
a Total Erection Price exclusive of GST 0.00
3 Total Price for Evaluation [3=1a+2a] 0.00
4 Applicable GST @ 18%(CGST @9 %+ SGST@9 %) 0.00
5 Total Price for Award [5=3+4] 0.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT37,Notice inviting tender, Motipur,BIADA.pdf
NIT • 0.65 MB
NIT37_SBD Part 1,Motipur,BIADA.docx
NIT • 0.26 MB
NIT37_SBD Part 2,Motipur,BIADA.docx
NIT • 0.50 MB
NIT37_SBD Part 2B, Motipur,BIADA.docx
NIT • 9.77 MB
NIT37_SBD_Part 3,Motipur,BIADA.doc
NIT • 0.88 MB
NIT37_Techno commercial Check List,Motipur,BIADA.xlsx
NIT • 0.02 MB
NIT37_TECHNICAL SPECIFICATION FOR RAIL POLE.docx
NIT • 0.01 MB
NIT37_Isolators and AB Switches.docx
NIT • 0.03 MB
NIT37_TS for 11KV Horn Gap Fuse Assembly.docx
NIT • 0.02 MB
NIT37_TS Outdoor VCB.pdf
NIT • 0.11 MB
NIT37_Infra_SBE_Tender Drawings_Version-2.pdf
NIT • 14.62 MB
NIT37_BOQ, Motipur,BIADA.xlsx
NIT • 0.04 MB
C1 Notice Time extension,37NIT,BIADA, Muzaffarpur .pdf
Corrigendum • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .