| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | ₹9.1 L | L1 | Accepted-AOC BEING L1 AND REASONABLE |
| 2 | L2₹9.4 L+₹33,220 (3.64%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | ₹9.4 L+₹33,220 (3.64%) | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹10.2 L
EMD Value
₹20,500
Closing Date
24 Oct 2024, 6:00 pmClosed
Shri Santosh Kumar Rai IDSE SE CWE NB
Commander Works Engineer NB Kochi Kataribagh Naval Base PO Kochi 682 004
REPAIR AND MAINTENANCE OF 11 KV SUB STATIONS, VCBs/RMU, TRANSFORMERS AND ALLIED WORKS AT COAST GUARD AT CG DHG-12, KAVARATTI, ANDROTH AND MINICOY UNDER GE (NAVY) LAKSHADWEEP
2024_MES_676108_1
81154/NB/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KAVARRATI LAKSHADWEEP
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE (NAVY) LAKSHADWEEP
₹20,500
Yes
13 Dec 2024
23 Sept 2024
26 Oct 2024
23 Sept 2024
24 Oct 2024
7 Oct 2024
Amount
Repairs and servicing of HT 11 KV VCB/RMU of current rating upto 630Amps capacity type by drawing out breaker assembly from panel and carry out the following work :- (i) Cleaning/ decarbonising of all fixed and moving contacts, levers, springs using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, (ii) Adjust the trolley in and out mechanism (iii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turning, polishing of main and auxiliary contact, demoisturing of insulators, etc to be done (iv) Checking all end terminals, tighting the nut bolt and washers, replace the unserviceable nut, bolt & washers, draw-in the breaker, put in position, engage the VCB/RMU with the supply system and testing for smooth functioning complete all as specified and directed by Engineer in charge. Note 1 :- Cost of unserviceable spare parts such as charging motor, EFR, Aux relays, Vaccum interrupters, Vertical connection adapter, Fixed/Moving contacts, Battery backup etc. will be measured and paid under respective items. Note 2 :- Primary/Secondary injection Test Kit and Insulation testing equipment shall be arranged by the contractor and rate deemed to be included the unit rate. Make: M/s Siemens India Ltd / Schneider/ABB or equivalent as approved by GE.
Supply and Fix in replacement Earth fault relay suitable HT 11 KV VCB/RMU including taking down old unserviceable one complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement Auxilary relays suitable for existing make HT11 KV VCB/RMU including taking down old unserviceable one complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement of vacuum interrupters 11KV with all fittings suitable for existing make HT11 KV VCB/RMU and testing complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement of current transformer 5/5 A suitable for existing make HT11 KV VCB/RMU and testing complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement of current transformer 20/5 A suitable for existing make HT11 KV VCB/RMU and testing complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement of Potential Transformer with primary voltage 11KV and secondary voltage 110/220 V suitable for existing make HT11 KV VCB/RMU and testing complete all as specified and directed by Engineer in charge.
Supply and Fix Charging motor operates on single Phase 230 V AC,50 Hz power supply for auto charging of HT breaker suitable for existing make HT11 KV VCB including taking down old unserviceable one complete all as specified and directed by Engineer in charge.
Supply and Replacement of unserviceable Battery 12 Volts 150 AH including taking down unservisable battery complete all as specified and directed by Engineer in charge. Make - Exide /Amaron/Standard farukwa/AMCO or as approved by GE
Disconnection and removing old unserviceable Power Pack unit providing, installation & commissioning of Power Pack Input 230 V AC, Output 12 V DC suitable for 11 KV HT VCB/RMU Panel complete all as specified and directed by Engineer in charge.
Topping up / complete renewal of transformer oil having breakdown strength not less than 60 KV/Min for oil cooled Transformers complete all as specified and directed by Engineer in charge. Make : Power oil/Servo /any ISI make as approved by GE
Supply and replace the silica gel for transformer of any capacity complete all as specified and directed by Engineer in charge.
Disconnection and removing unserviceable Transformer Tap changer and Supply and Fix new Transformer Tap changer made of Brass/Copper material for regulating LT volage suitable for existing Transformer of any capacity complete all as specified and directed by Engineer in charge.
Disconnection and taking down the Transformer of any capacity from the existing position and transporting to work shop and opening the outer cover, draining out the oil and lifting the core along with winding, finding the faulty /burnout primary and secondary winding and rewinding with fine enameled insulated copper winding of same size/guage, turns keeping in hot air oven till the moisture evoporates, reassembling the transformer parts such as core, winding, outer cover, refilling back the Transformer oil complete and transporting back to its original position and reconnecting the LT/HT cable connections complete all as specified and directed by Engineer in charge.
Material and labour for cable jointing kit for 11KV grade cable for outdoor termination heat shrinkable type end termination joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engineer in charge.
Material and labour for cable jointing kit for 11KV grade cable for outdoor termination heat shrinkable type end termination joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer in charge.
Material and labour for cable jointing kit for 11KV grade cable for indoor termination heat shrinkable type end termination joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engineer in charge.
Material and labour for cable jointing kit for 11KV grade cable for indoor termination heat shrinkable type end termination joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer in harge.
Material and labour for outdoor type straight through jointing kit heat shrinkable for 11KV grade UG cable suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 120 Sqmm to 185 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for outdoor type straight through jointing kit heat shrinkable for 11KV grade UG cable suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 50 Sqmm to 95 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour in replacement of XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3 core, 11000 volts, grade of the size 95 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour in replacement of XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3 core, 11000 volts, grade of the size 185 Sqmm complete all as specified and directed by Engineer in charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for taking out/laying of cable and getting out in soft/loose soil complete all as specified and directed by the Engineer-in-charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directedby Engineer in charge.
Removing excavated material (Soil) to a distance n exc. 50 m and depositing where directed at a level n exc. 1.5 m above starting point complete all as specified and directed by Engineer in charge.
Material and labour for sand cushioning with sand in two layer, first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified and directed by Engineer in charge. Note:- Punned thickness only shall be measured for the purpose of payment.
Supply and laying unreinforced precast concrete cable cover class HV, Type I, flat, size 300x180x40 mm for HT cable all sizes complete all as specified and directed by Engineer in charge.
Supply and fix in repair of transformer LT side bushing/insulator with neoprene washer with terminal studs and bolt, nuts, etc complete all as specified and directed by Engineer in charge.
Supply and fix in repair of transformer HT side bushing/insulator with neoprene washer with terminal studs and bolt, nuts, etc complete all as specified and directed by Engineer in charge.
Jack Electrolinks Private Limited (BID ID -3144173)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .