Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.5 L+₹12,506 (0.35%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.2 L+₹1.8 L (5.06%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹42.8 L+₹7.4 L (20.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹44.0 L+₹8.6 L (24.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | M/S Sunshine Construction L2 | M/S Parikshit Sharma L3 | NIDHI CONSTRUCTION L4 | Manoj Electricals L5 | m/s ajay chandil L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for roughening / taking down existing roof treatment surfaces including plaster over old concrete roof by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed.
Note : All demolished item shall be removed from Defence land as per dirns of Engr-in Charge. | 600 | Sqm | 10 ₹6,000 | 10 ₹6,000 | 12 ₹7,200 | 15 ₹9,000 | 5 ₹3,000 Lowest |
| 2.00 | M & L for brushing neat cement slurry with 3 Kg of cement per Sqm for bonding of old concrete surface to new concrete/plaster surfaces complete all as specified and directed. | 600 | Sqm | 20 ₹12,000 | 15 ₹9,000 | 15 ₹9,000 | 35 ₹21,000 | 8 ₹4,800 Lowest |
| 3.00 | M & L for cutting out cracks to 6 mm wide 'V' section in existing roofs or terrace (if cracks > 2.5 mm wide), cleaning out, wetting, grouting with and including chemical compound, water and cement Sand slurry in the proportion of (1:3) by weight mix or as per manufacturers instructions complete all as specified and directed.
Note : All demolished item shall be removed from Defence land as per direction of Engr-in Charge. | 100 | RM | 50 ₹5,000 Lowest | 100 ₹10,000 | 100 ₹10,000 | 130 ₹13,000 | 50 ₹5,000 Lowest |
| 4.00 | M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) mixed with Liquid waterproofing chemical @ 200 millilitre per 50 Kg per cement, as in padding on roof surface for correcting / making proper slope on roof, and finishing the surfaces fair and even without using extra cement complete all as specified and directed.
Note:- WPC shall be measured and paid separately. | 10 | Cum | 3,500 ₹35,000 | 5,000 ₹50,000 | 5,000 ₹50,000 | 5,500 ₹55,000 | 3,000 ₹30,000 Lowest |
| 5.00 | M & L for 10 mm thick rendering in CM (1:3) mixed with Liquid water proofing chemical compound @ 200 mililitre per 50 Kg cement as per manufacturers instructions over concrete surface and finishing the surface fair and even without using extra cement complete all as specified and directed.
Note:- WPC shall be measured and paid separately. | 250 | Sqm | 130 ₹32,500 Lowest | 140 ₹35,000 | 150 ₹37,500 | 180 ₹45,000 | 130 ₹32,500 Lowest |
| 6.00 | M & L for screed bed 15mm thick in cement mortar 1:3 mixed with integral water proofing compound while concrete surface is green and finish the surface even and smooth without using extra cement complete all as specified and directed.
Note:- WPC shall be measured and paid separately. | 600 | Sqm | 150 ₹90,000 | 160 ₹96,000 | 180 ₹1,08,000 | 230 ₹1,38,000 | 140 ₹84,000 Lowest |
| 7.00 | M&L for complete water proofing treatment on "Non approachable / non accessible roof" surface (Horizontal & Vertical surfaces) in following sequence through authorized applicator of the manufacturer all as specified and directed complete.
(i) Cleaning of new rendered surfaces properly and drying the surfaces.
(ii) Applying a coat of oxidised bitumen based solvent primer @ 0.30 Kg / Sqm
(iii) Laying 3 mm thick APP modified water proofing membrane with 100 mm over laps sealed and bounded to the surfaces by 'torchon' method.
(iv) Applying two coats of bitiminous aluminium paint @ 200 Gram / Sq M (minimum) in two coats complete as per manufacturers instruction.
Note:- Waterproofing treatment shall be executed by a qualified team provided by the manufacturer or their authorised applicator. | 600 | Sqm | 370 ₹2,22,000 Lowest | 450 ₹2,70,000 | 450 ₹2,70,000 | 500 ₹3,00,000 | 400 ₹2,40,000 |
| 8.00 | M&L for complete water proofing treatment to sunken floor surfaces of RCC slab by the following specifications including demolition/taking down and cleaning of old surface as specified and directed :-
(a) Plain cement concrete 1:5:10 mix, type E-2 (using 40mm graded aggregate) as in filling of sunken portion complete all as specified and directed.
(a) PCC (1:1.5:3) type A0 with using 12.5mm graded stone aggregate in slope of average thickness 50mm mixed with and including liquid water proofing compound as approved by GE.
(b) Rendering 15mm thick in CM 1:3 mixed with & including water proofing compound on sides of (Vertical surface) sunken floor slab.
(c) Finally Apply two coats of black bituminous paint on complete surfaces of floor & wall and provide necessary connections to soil/waste pipe from WC/ nahani trap etc.
(d) Spray of sand on bituminious surfaces.
Note:- Waterproofing treatment shall be executed by a qualified team provided by the manufacturer or their authorised applicator. | 60 | Sqm | 1,500 ₹90,000 | 1,000 ₹60,000 | 1,800 ₹1,08,000 | 1,500 ₹90,000 | 500 ₹30,000 Lowest |
| 9.00 | M&L for PCC 1:2:4 type B 0) using 12.5 mm graded stone aggregate mixing with WPC as in levelling course and in sunken portions etc incl demolition of old PCC complete all as specified and directed. | 1.5 | Cum | 4,000 ₹6,000 Lowest | 4,800 ₹7,200 | 5,000 ₹7,500 | 6,000 ₹9,000 | 4,000 ₹6,000 Lowest |
| 10.00 | M & L for complete reparing of RCC roof projection, chajjas,roofs, facia, column etc by necessary preparation i.e scrapping ,cutting,chiseling,derusting and cleaning exposed reinforecement, surfaces of damaged, loose RCC surfaces and applying one coat of rust remover by brushing to rusted reinforecemnt to remove loose rust particles and allow to dry it for 2 to 3 Hrs , insert the new reinforcement to damaged portion by drillig hole at required distance , fill the epoxy in to the hole by 2/3 of the hole and insert the reinforcement in the hole, and binding the reinforcement at rusted portion of reinforcement, apply cement slurry on entire damaged area , and plaster the surfaces with cement , sand and Polymer liquid in 1: 3 : 15% of cement by weight ) and water as required , mixing properly and plaster the surface , finished even and smooth by making the edge water dropping groves complete all as specified and directed.
Note : The work shall be carried out on building upto 8.00 m height. The quoted rate shall be inclusive of all necessary scaffolding and safety devices as required. No additional payment shall be admissible. | 50 | Sqm | 600 ₹30,000 | 600 ₹30,000 | 300 ₹15,000 Lowest | 350 ₹17,500 | 400 ₹20,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Jul 2025, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School Mhow (MP) - 453441
REPAIR MAINT OF SUNKEN TREATMENT LEAKAGE SEEPAGE CLEANING OF OVERHEAD TANKS AND ALLIED WORKS IN ZONE D AND E AND REPAIR MAINT TO DRAINS CULVERTS FENCING HARDSTANDING FOOTPATH COMPOUND AT OTM AREA OF AGE BR I UNDER GE MIS MHOW
2025_MES_710494_1
8784/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
180 days
GARRISON ENGINEER (MIS)
All as per Tender document
8 documents required · 8 mandatory
₹500
GE (MIS) Mhow
₹90,000
Yes
19 Aug 2025
27 May 2025
5 Jul 2025
27 May 2025
3 Jul 2025
10 Jun 2025
Amount
M & L for roughening / taking down existing roof treatment surfaces including plaster over old concrete roof by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed. Note : All demolished item shall be removed from Defence land as per dirns of Engr-in Charge.
M & L for brushing neat cement slurry with 3 Kg of cement per Sqm for bonding of old concrete surface to new concrete/plaster surfaces complete all as specified and directed.
M & L for cutting out cracks to 6 mm wide 'V' section in existing roofs or terrace (if cracks > 2.5 mm wide), cleaning out, wetting, grouting with and including chemical compound, water and cement Sand slurry in the proportion of (1:3) by weight mix or as per manufacturers instructions complete all as specified and directed. Note : All demolished item shall be removed from Defence land as per direction of Engr-in Charge.
M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) mixed with Liquid waterproofing chemical @ 200 millilitre per 50 Kg per cement, as in padding on roof surface for correcting / making proper slope on roof, and finishing the surfaces fair and even without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M & L for 10 mm thick rendering in CM (1:3) mixed with Liquid water proofing chemical compound @ 200 mililitre per 50 Kg cement as per manufacturers instructions over concrete surface and finishing the surface fair and even without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M & L for screed bed 15mm thick in cement mortar 1:3 mixed with integral water proofing compound while concrete surface is green and finish the surface even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M&L for complete water proofing treatment on "Non approachable / non accessible roof" surface (Horizontal & Vertical surfaces) in following sequence through authorized applicator of the manufacturer all as specified and directed complete. (i) Cleaning of new rendered surfaces properly and drying the surfaces. (ii) Applying a coat of oxidised bitumen based solvent primer @ 0.30 Kg / Sqm (iii) Laying 3 mm thick APP modified water proofing membrane with 100 mm over laps sealed and bounded to the surfaces by 'torchon' method. (iv) Applying two coats of bitiminous aluminium paint @ 200 Gram / Sq M (minimum) in two coats complete as per manufacturers instruction. Note:- Waterproofing treatment shall be executed by a qualified team provided by the manufacturer or their authorised applicator.
M&L for complete water proofing treatment to sunken floor surfaces of RCC slab by the following specifications including demolition/taking down and cleaning of old surface as specified and directed :- (a) Plain cement concrete 1:5:10 mix, type E-2 (using 40mm graded aggregate) as in filling of sunken portion complete all as specified and directed. (a) PCC (1:1.5:3) type A0 with using 12.5mm graded stone aggregate in slope of average thickness 50mm mixed with and including liquid water proofing compound as approved by GE. (b) Rendering 15mm thick in CM 1:3 mixed with & including water proofing compound on sides of (Vertical surface) sunken floor slab. (c) Finally Apply two coats of black bituminous paint on complete surfaces of floor & wall and provide necessary connections to soil/waste pipe from WC/ nahani trap etc. (d) Spray of sand on bituminious surfaces. Note:- Waterproofing treatment shall be executed by a qualified team provided by the manufacturer or their authorised applicator.
M&L for PCC 1:2:4 type B 0) using 12.5 mm graded stone aggregate mixing with WPC as in levelling course and in sunken portions etc incl demolition of old PCC complete all as specified and directed.
M & L for complete reparing of RCC roof projection, chajjas,roofs, facia, column etc by necessary preparation i.e scrapping ,cutting,chiseling,derusting and cleaning exposed reinforecement, surfaces of damaged, loose RCC surfaces and applying one coat of rust remover by brushing to rusted reinforecemnt to remove loose rust particles and allow to dry it for 2 to 3 Hrs , insert the new reinforcement to damaged portion by drillig hole at required distance , fill the epoxy in to the hole by 2/3 of the hole and insert the reinforcement in the hole, and binding the reinforcement at rusted portion of reinforcement, apply cement slurry on entire damaged area , and plaster the surfaces with cement , sand and Polymer liquid in 1: 3 : 15% of cement by weight ) and water as required , mixing properly and plaster the surface , finished even and smooth by making the edge water dropping groves complete all as specified and directed. Note : The work shall be carried out on building upto 8.00 m height. The quoted rate shall be inclusive of all necessary scaffolding and safety devices as required. No additional payment shall be admissible.
M&L (in repairs) for preparation of surface for application of water based epoxy resin coating of waterproofing for internal wall dampness and filling of cracks over & including CM (1:4) and making the surface smooth and finish complete all as specified and directed. Note : (a) Complete removal of treatment/plaster(where needed) on internal walls and preparation of surface after rendering with CM(1:4) for application and making the surface wet .(b) apply first coat of Dr. fixit Dampguard in ratio (1U base:1U hardner:1U water) in one direction and leaving the coat to dry for 6 to 8 hrs.(c) apply second coat of Dr. fixit dampguard in ratio(1U base:1U hardner:1U water) in perpendicular direction to the first coat applied and leaving the surface to dry for 24 hrs. Material: Dr. fixit Dampguard or the makes/brand/manufacturers as specified in Appendix 'A' of the Particular Specification.
S&F in repairs mild steel work (Tubular, square/rectangular hollow section) as in purline, rafter and wind ties, cleat roof trusses etc including securing bed plate, plat iron fillets for securing wire mesh etc including all necessary drilling bolting or riverting, etc, and similar work conforming to IS 1161-1979 dge St-240 complete all as specified and directed.
M&L for preparation of new steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
S&F 0.50mm thick (total coated thickness) pre-colour, pre profiles Galvalume /zincalume sheets of required colour and design having tensile strength of 550 Mpa, zinc colour coating AZ-150 as in roof ,wall cladding,north light curves,fixed with zinc coated self drilling fastener including EDPM washer complete laid with one corrugation side laps and min 150mm end laps laid to slope all as per manufacturer/profile maker instructions including dismantling old Plain or corrugated steel sheeting,any gauge, thickness, complete all as specified and directed. Note:- The pre-painted galvalume zinc GI based profile pattern steel should be TATA Blue scope colour brand XRW or the makes/brand/manufacturers as specified in Appendix 'A' of the Particular Specification.
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement for inserting galvalume sheet on wall and necessary coping work over the sheet along the wall complete all as specified and directed.
M&L for rendering 15 mm thick in CM ( 1:4 ) on wall/ concrete surfaces finish even and smooth without using extra cement using WPC compound complete including taking down old plaster complete all as specified and directed. Note: WPC shall be measured and paid separetly.
M&L for rendering 10 mm thick in CM ( 1:6 ) on wall/ concrete surfaces finish even and smooth without using extra cement including taking down old plaster complete all as specified and directed.
M&L for 5 mm thick plaster on ceiling in cement mortar 1:3 finished even and smooth without using extra cement including taking down old plaster complete all as specified and as directed .
Supply only Liquid water proofing compound ISI marked complete all as specified and as directed .
M & L for preparation of new plastered surfaces of walls and applying two coat of cement based paint over a coat of cement primer complete all as specified and directed
M&L for applying two coat of oil bound distemper over a coat of 1.50 to 2mm thick wall care putty (JK/Birla) on new plaster surface of walls after -preparation of surfaces complete all as specified and as directed .
M & L for preparing new surfaces of wall and applying three coats of white wash on ceiling and cornices complete all as specified and directed.
M & L for preparation of old decorated surface of wall including brooming, down, scrapping down smoke spot and stopping nails mark by filling Birla white putty and applying one coat of cement based paint over one coat of primer complete all as specified and directed.
M & L for complete removal of existing treatment on old decorated surfaces of wall and applying two or more coats of 100% Premium arcylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade over and including 1.50 to 2mm thick wall care putty and one coat of priming coat of exterior primer complete all as specified and directed. Note- (a) Application of primer and arcylic emulsion paint shall be carried out using an airless spray machine (mechanical means). (b) Wall care putty shall be applied properly to achieve a smooth wall surface. (c) The work will be carried out in a building up to Ground plus Three (G+3) floors. (d) The quoted rate shall be inclusive of all necessary scaffolding and safety devices as required. No additional payment shall be admissible.
M&L for preparation of old decorated surfaces of wall including brooming, washing, roubbing scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying one coat of oil emulsion distemper complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including brooming, washing, rubbing scraping down with complete removal Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying one coat of white wash on walls complete all as specified and directed.
All as per item No. 26.00 above but on ceiling surface
M&L for preparation of old painted surfaces of wood/wood based materials exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
All as per item No. 27.00 above but on steel surfaces.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.50mm graded crushed stone aggregate as in sub base, levelling course, etc complete all as specified and as directed.
M&L for 40mm thick PCC type B1 (1:2:4) using 20 mm graded stone crushed stone aggregate as in flooring and finished complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1: 6 including demolition of old tiles/flooring complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1: 6 including demolition of old tiles/flooring complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 300x200x7 mm thick as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over and including10 mm thick backing coat on fair faces of brick work in CM (1:4) including demolition of old tiles/flooring complete all as specified and as directed.
M&L in repair for glazed ceramic coloured tiles of size 450x350x7 mm thick as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over 10 mm thick backing coat on fair faces of brick work in CM (1:4) complete all as specified and as directed.
M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in foundation, sub base of floor, etc including demolition of old PCC complete all as specified and directed
M & L for 75mm thick cement concrete 1:3:6 type C2, with using 40mm graded stone aggregate as in floor/ plinth protection finish the surface even and smooth without using extra cement including filling the expansion joints with bitumen filler / filler boards and necessary form work etc including demolition of old PCC complete all as specified and directed
M&L for chequered cement concrete tiles (glossy finish) 40 cm x 40 cm x 25 mm thick set ,jointed and pointed in neat cement slurry in floors with grey cement and no pigment laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) and necessary PCC coping ,type C1 1:3:6 ncluding dismantling of old tiles laid bedded and pointed in any mortar Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed.
M&L for 60 mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size & colour confirming to IS 15658-2006 with grey cement and no pigment and necessary PCC coping ,type C1 1:3:6 including dismantling of old tiles laid bedded and pointed in any mortar Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed.
M&L for 80 mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-40 Gde of approved shape, size & colour confirming to IS 15658-2006 with grey cement and no pigment and necessary PCC coping ,type C1 1:3:6 including dismantling of old tiles laid bedded and pointed in any mortar Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed.
M&L for stone dust under floors or in foundations including watering and consolidation spreading and levelling in layers n exc. 25 cm thick complete all as specified and as directed.
S&F in repair of 500 ltrs capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including taking down old water tank complete all as specified and as directed.
Cleaning and removing all dirts and scales from service water tanks and from mouth of circulating pipes etc capacity of tank exceeding 250 ltr but not exceeding 500 ltr complete all as specified and directed.
S&F in repair of 15mm bore ball valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipes and fixed. ( Min Weight 15mm-142 gms) complete all as specified and as directed.
S&F steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in ceiling or in floors including cutting threading and making forged bends on pipes MS hooks etc ,for 15mm bore pipes incl taking down old pipe complete all as specified and as directed.
All as per item No 45.00 above but 20mm bore
Cutting chases in brick wall built in cement mortar for concealed water tubing and making good with cement mortar 1:4 ,cutting depth not exc 10 cm complete all as specified and directed.
S&F in repairs 15 mm CP long neck bib taps screwed down high pressure chromium plated screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15 mm bib taps cast copper alloy, screwed down high pressure chromium plated screwed for iron pipe and fixed complete all as specified and directed.
S&F 15 mm bib cock two way with flange, cast copper alloy, fancy type, chromium plated screwed down for iron pipe and fixed in repairs complete all as specified and directed.
S&F in repair stop valves fancy type chromium plated with long shanks fixed with 15 mm dia bore pipes complete all as specified and as directed.
S&F in repair pillar taps (swan neck type) cast copper alloy with capstan head, screwed down ,high pressure with long screwed shanks and fly nuts fixed in 15 mm bore pipes complete all as specified and directed.
S&F in repairs 15 mm stop cock cast copper alloy, screwed down high pressure chromium plated screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs Stainless steel sink, 1.00mm thick for kitchen, with plug, washers and wastes/coupling, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm with bowl size 410mmx 330mmx 160mm fixed with PVC waste pipe complete all as specified and directed.
S&F in repairs Stainless steel sink with drainage board , 1.00mm thick for kitchen, with plug, washers and wastes/coupling,waste pipe etc including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm with bowl size 410mmx 330mmx 160mm fixed complete all as specified and directed.
M&L for stainless steel plate rack for kitchen 1 mm thick of best quality with suitable hanging arrangement and fixed to wall complete all as specified and as directed by Engineer-in-Charge.Note:- Size of plate rack should not be less than 900x900 mm and weight of rack shall not be less than 8.5 Kg each complete all as specified and directed.
S&F in repairs PVC low level flushing cistern of 10 Litres with all internal fittings including flush pipe complete all as specified and directed.
Taking down and re-fixing WHB/flushing cistern/EWC/ kitchen sink and similar items at same or other location, including cutting for ends and pinning in and ends of brackets or erecting stand but exclusive of fixing of supply and waste pipes,etc complete all ass specified and as directed.
S&F in repair vitreous china wash down water closet pedestal pattern white and flush pipes including white PVC seat cover complete all as specified and as directed .
S&F in repair vitreous china squatting pan `Orissa ' pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipes) including connection to trap and to flush pipe etc and lime concrete bedding including 'P' or 'S' trap complete all as specified and as directed.
S&F in repair health faucet with flexible pipe of one mtr length including wall hook for EWC complete all as specified and as directed. .
S&F in repair flexible type PVC waste pipe 32 mm bore of pipe for WHB/SINK/urinal, etc complete all as specified and as directed.
S & F in repairs PVC (SWR) floor trap plain or multi with stainless steel grating including joining to waste pipe with solvent cement joint dia of outlet 75mm bore complete all as specified and as directed.
S&F in repairs of brass CP tubular towel rail 20 mm dia 60cm long between flange with brackets etc as complete all as specified and directed.
S&F in repair 125 mm size chromium plated shower rose with siwel joint suitable for 15 mm bore GI pipes complete all as specified and directed.
S&F in repairs Plastic water closet seat cover in white colour, closed pattern with flat bottom, and mild steel chromium plated for aluminised hinging device complete all as specified and directed.
S&F in repairs wash basins, vitreous China white flat back size 580x450mm size, including cutting for and pinning in ends with & including MS adjustable brackets or erecting stand complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm.complete as in repairs.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repairs corner glass shelf (with bracket) complete all as specified and directed.
S&F in repair 150 mm long ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
S&F in repair of CP grating 100mm dia complete all as specified and directed.
S&F in repair 25 mm dia aluminium powder coated drappery curtain rod with brass /nickel chrom polish bracket complete all as specified and directed .
S&F in repair CP waste coupling of size 32 mm dia WHB with long screwed shanks and fly nut fixed in repair complete all as specified and directed.
S & F in repair over head tank cover of 500-1000ltr capacity all as specified and directed by Engr-in-charge.
S & F in repairs brass spindles for bib tap and angle cock etc (as per sample kept in office) complete all as specified and directed.
Resecuring or easing and adjusting without taking down shutter of any discription n exc 1.0 sqm each complete all as specified and directed.
Resecuring or easing and adjusting without taking down shutter of any discription exc 1.0 sqm but nexc 2.0 sqm each complete all as specified and directed.
S&F in repair 100mm aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed.
All as per item No 80.00 above but 150mm long
S&F in repair aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruted section and fixing bolt and sliding bolts of extruded section and cast iron - aluminium alloy 300 mm long complete all as specified and directed.
S&F in repair 150 mm long aluminium handles, cast type, anodised fixed to shutters complete all as specified and directed.
S&F in repair 100 mm Butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F in repair 75 mm Butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F in repair 50mm Butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F in repair 40mm dia cupboard knobes fixed with nuts, screw and washer of MS, bright finshed complete all as specified and directed.
S&F in repair of floor door stopper 140mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S&F in repair Mild Steel Door Spring 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repairs of Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per Item No 91.00 above but except pipe
S&F in repairs PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per Item No 93.00 above but except pipe
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed.
S&F PVC junction single (single T) 110mm dia equal or unequal with access door complete all as specified and directed.
S&F PVC junction single (single T) 75mm dia equal or unequal with access door complete all as specified and directed.
Cleaning of roof slab/chajja with sweeping with brooms,removing all depositions/ mud/ vegetations etc and removing the spoil to a distance n.exc 50m complete all as specified and directed.
Cutting of shubs,vegetation including small trees,grass,bush,weed and roots under growth and saplings n.exc 30cm in girth on wall/roof/chajja upto 15.00 hight including necessary scaffolding/ ladder etc and removing to adistance n.exc 50m ,clearing site complete all as specified and directed. Note : The work shall be carried out on buildings upto 15.00 m height. The quoted rate shall be inclusive of all necessary scaffolding and safety devices as required. No additional payment shall be admissible.
Cleaning of roof slab/chajja with sweeping with brooms,removing all depositions/ mud/ vegetations etc and removing the spoil to a distance n.exc 50m complete all as specified and directed.
Cleaning and removing all scale and dirt, etc from water tanks of capacity exceeding 250 litres but not exceeding 500 litres and from mouth of circulating pipes, etc including writing date of cleaning and applying a coat of bleaching powder complete all as specified and directed.
Cleaning and removing all scale and dirt, etc from water tanks of capacity exceeding 500 litres but not exceeding 1000 litres and from mouth of circulating pipes, etc including writing date of cleaning and applying a coat of bleaching powder complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregates as in copings etc. and in similar works including weathering,slightly rounded or chamfered angles and throating and necessary form works including demolition of existing old PCC work complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in surface channels and drains and necessary form works including demolition of existing old PCC work complete all as specified and directed.
M & L for brick work with using modular size fly ash bricks, straight or curved on plan exc. 6 m mean radius built in cement mortar (1:6), including demolition of brick work complete all as specified and directed.
All as per Ser No 107.00 above but except bricks.
M&L for preparation of old plastered or unplastered surfaces of walls including cornices, pillasters by brooming down or steel wire smoke, root, moulds, moss and efforescent salts, and trading oil and greasy spot by using suitable chemical & removing nails, making good holes with chalk whiting, filling cracks and brooming to remove all dirt etc and applying two coat of cement based paint on old prepared surfaces of walls complete all as specified and directed. Note : The work shall be carried out on building upto 12.00 m height. The quoted rate shall be inclusive of all necessary scaffolding and safety devices as required. No additional payment shall be admissible.
Demolition of reinforced cement concrete of any description and in any position (Reinforement cut as required to facilitate demolition) complete all as specified and directed.
M&L for Pre-cast RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in manhole cover slab fixed in position including necessary form work and set in CM 1:6 complete all as specified and directed.
S&F mild steel TMT 6 to 8 mm dia cut to length, bent to shape, required including cranking, bending, spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F in repairs galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain-ing bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire. staples or steel pins etc as directed. (Each line wire to be measured).
Restraining and resecuring including making good staples etc galvanized two strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain-ing bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire. staples or steel pins etc as directed. (Each line wire to be measured).
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for Plain cement concrete type C-2(1:3:6) using 40mm graded stone agg as in foundition filling and mass concrete complete all as specified and directed.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire; flat iron fillets (for securing wire mesh) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Mild steel rag or lewis bolts12 mm dia and nuts screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n exc 15cm complete all as specified and directed.
S&F Mild Steel round bars 8 mm dia and over of Fe 410 W quality A or Fe 290 quality-A, bent to shape required, incl crancking ,bending spirally for hooping for column, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips in chain link fencing complete all as specified and directed.
S&F Mild steel in flat, round or square bars, in available length 40 x 6 mm FI strip fixed to chain link fencing complete all as specified and directed.
Dismantling fencing wire mesh any type complete all as specified and directed.
S&F chain link fencing of 4 mm dia GI wires and 50x50mm mesh size weight not less than 4.50 Kg per sqm including, rails, straining bolts etc including provision of binding wire complete all as specified and directed.
M&L for cement concrete itype E-2, 1:5:10 (using 40 mm graded stone aggregate) as in fundation filling, mass concrete, sub base etc complete all as specified and directed.
M&L for Precast factory made cement concete block as in Kerb stone type B1 1:2:4 (using 20mm graded stone aggregate) fixed in dry mortar as per required size and thickness complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on concrete surface over coat of primer including prepartion of new surface over 10cm width or girth complete all as specified and directed.
M/S Sunshine Construction (BID ID -3335113)
M/S Parikshit Sharma (BID ID -3339766)
NIDHI CONSTRUCTION (BID ID -3341967)
Manoj Electricals (BID ID -3344309)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .