(i) Reliability improvement work with Replacement And Rehabilitation of telecom gears and Telecom cables, OFCs in Bangaon-Barasat-Hasnabad-Dumdum Jn.-Rajchandrapur, Sealdah-Ballygunge-Sonarpur-Canning-Baruipur-Namkhana-Diamond Harbour-Budge Budge-Majerhat section of Sealdah division. (ii) Telecom work in connection with replacement of existing Panel Interlocking System with new Electronic Interlocking System at Nischindapur(NCP) Station.
SDSTE-TLE-T9-25-26CAPRRSK~ER
SDSTE-TLE-T9-25-26CAPRRSK
Open
Works - General
12 Months
24 Paraganas South, West Bengal
₹0
₹3.2 L
29 Dec 2025
3 Dec 2025
15 Dec 2025
A-NON-SCHEDULE/SOR ITEM vide SL. NO. 1 to 197 GIVEN IN SCHEDULE OF
18 %. GST HAS BEEN SHOWN IN ITEM BREAKUP SEPARATELY.
NON-SCHEDULE/SOR ITEM vide SL. NO. 1 to 197 GIVEN IN SCHEDULE OF WORK INCLUDING GST @ 18 %. GST
HAS BEEN SHOWN IN ITEM BREAKUP SEPARATELY
S No. Item Description of Item Unit Qty Rate Amount
1 1 Excavation of cable trench as per cable route plan, 1.2 cum 4500.00 232.20 1044900.00
Mtr. deep and of 0.3 Mtr. wide at bottom as per RDSO
sketch No. SDO/CABLE LAYING/003 or latest alongside
the track in normal (all type) soil/strata, conforming to
distances as per cable route plan and refilling. This work
includes clearing of route from bushes etc, covering of
cable laid in trench by loose soil for a layer of 50mm
thickness approximately before covering by
bricks(Bricks will be provided by contractor). The work
shall be done as per the extant practice on Eastern
Railway and instructions of Railway Engineer at site.
Note:-(a)for all trenches from distant signal to home
signal and to relay room, the minimum headway above
the uppermost cable in the trench should be 600mm. If
due to a large no. Of cables headway is not available, 4"
of 1:2:4 concreting should be done.
SEALDAH DIVISION-S AND T/EASTERN RLY
2 2 Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. cum 280.00 421.19 117933.20
Wide on Platform / Road / Hard rocky area. Refilling with
earth leveling of trenches & restoring the original
surface of trenches. The sharp edges will be
smoothened out in bottom of the chase and will be
leveled properly. In hard rocky ground area , cables will
be laid normally on layer of shifted earth of 0.05 mtrs
thickness previously deposited at bottom of the trench
and cables will be covered with layer of sand or shifted
earth of 0.1 mtr thickness. In case sharp edges of rocky
ground cannot be protected from shifted earth then GI/
C I /PVC /DWC/ HDPE pipes will be used, if numbers of
cables is small. In case number of cables are large RCC
duct will be used. In isolated cases, it can be given
smooth surface by using either masonry bricks or
cement concrete. A row of bricks shall then be placed
length wise on the top and jointed with cement mortar
and layer of concrete with cement plaster shall be
provided on top of the same.Note: This item in hard
rocky area will be operated only where normal depth
i.e.1.2 mtr is not possible and it will be decided by site
engineer/unit officer incharge of work.
3 3 Digging of trench 1.2 Mtrs. deep from rail flange/ road cum 210.00 235.59 49473.90
level and 0.3 Mtrs wide and back filling after placing of
DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered
separately). The ballast disturbed be screened and
dressed as required by Engineer-in-charge or his
representatives and road tarred immediately. For track
crossing, RDSO sketch No. SDO/CABLE LAYING/009 or
latest and for Road Crossing, RDSO sketch No.
SDO/CABLE LAYING/010 or latest are to be followed.
4 4 Transportation of HDT machine with accessories Metre 150.00 1528.81 229321.50
including handling of stores materials, preparation of
sites and boring for placing of 110 mm dia or 3 Nos
40mm HDPE PIPE or as per site requirement for crossing
of S&T cables together a bridges/culvers, pucca
road/crossing, boring trench shall be minimum 3 (three)
meter below the river bed and 1(one) meter below the
track/road/pucca road crossing area. This includes
supply of HDPE pipes, including accessories, cost of fuel
and all other items etc. which will be required for laying
of cable through it.the work shall be executed as per
instruction of site engineer.HDPE PIPE TO BE SUPPLIED
AS PER RDSO SPEC. Contactor shall provide all material
required for boring and adequate nos. of labours for
proper laying of cables into the bore. Cable shall be laid
cautiously so that it should not get damage due to rough
handling & pressure on cable. Note: Hiring charges of
HDT machine will be bore by contractor.
5 5 Laying of telecom/Signalling cable/Power Cable with Metre 150.00 6.78 1017.00
nylon rope through HDPE pipe and back filling of boring
pit. Note: Cable will be supplied by Railway
6 6 Laying of S&T Cables of various cores/ pairs/ quads in RMT 19600.00 4.24 83104.00
trenches/ GI pipes/ RCC pipes/ HDPE/DWC pipes/
Trunking. This also includes laying of cables in track
crossings & road crossings. Item includes provision of
labels of coloured plastic adhesive tapes or any other
identifiable material on each cable to give the cable
number at each Gantry Post/hectometrepost.(Cables will
be meggered before and after its laying by contractor
under supervision of Railway Representative and the
contractor will submit the meggering report of each
testing). Length of the cable laid includes the length of
the cable coiled for termination purposes. Note: This
also includes laying of Quad/PIJF cable from BPAC/UFSBI
location to SM Room/Relay Room/OFC Room etc. &
Laying of under ground Earth cable as per instruction of
railway representative. Note: Quad/PIJF/Earth cable will
be provided by Railways.
7 7 "Supply of Medium class GI pipes 100 mm dia (4.5 mm Metre 100.00 645.76 64576.00
thickness) as per IS 1239 (Part 1): 2004 or Latest.
Inspection: Consignee"
8 8 "Supply of Medium class GI pipes 50 mm dia (3.6 mm Metre 100.00 342.37 34237.00
thickness) as per IS 1239 (Part 1): 2004 or Latest.
Inspection: Consignee "
SEALDAH DIVISION-S AND T/EASTERN RLY
9 9 "Supply of 'ELBOW'- BENDS to suit GI pipes 50 mm dia Numbers 20.00 90.00 1800.00
(3.6 mm thickness) Inspection: Consignee"
10 10 Laying & Fixing of Medium class GI pipes 50/100 mm dia Metre 200.00 83.05 16610.00
(4.5 mm thickness) & 'ELBOW'- BENDS to suit GI pipes
50 mm dia (3.6 mm thickness) as per IS 1239 (Part 1):
2004 with socket & coupling on culverts bridges or at
any other locations as decided by Site Engineer. It
includes installation of all material required for fixing
arrangement. Contractor will install flexible/corrugated
HDPE pipe at the end of GI pipe along with any masonry
work (if required) to protect the cables from sharp edges
and sudden bends. GI pipe, HDPE & ELBOW'- BENDS will
be provided by railway.
11 11 "Laying of Power Cable/CAT-6/Switch Board Cable/Earth Metre 1600.00 38.14 61024.00
cable/LS cable etc or any other cable in PVC casing
capping of appropriate size. The work also includes
supply and fixing of casing and capping as per
instructions of site incharge. Inspection: Consignee"
12 12 "Supply, Transportation at site and Installation of RCC Numbers 260.00 353.39 91881.40
cable route marker engraved and painted on both side
along the route at every 30 meter and at route
diversion. The cablemarker is to be fabricated as per
CCE/ER's Technical Circular No 108 dated 22.04.24 vide
drawing No.S.I.-S&T/1/2024 (Sheet No.1).The fixing work
is to be done as per extant practice of E. Rly. and as per
rly. site supervisor. Note : (i) Marker shall be placed in
the trench during closing the trench such that there is
no possibility of putting markers at wrong Location. (ii)
Colour Scheme shall be RED for Signal Cable , GREEN for
Quad Joints & YELLOW for OFC Joints. (iii) Engraving on
the RCC marker will be same for all the cables i.e ""ER
S&T CABLES"" Note-The cable route marker to be
provided as per technical circular no. 108 Inspection :
13 13 Closing of Cable Entry Holes by concrete permanently. Job 100.00 100.00 10000.00
All the materials required for the work i.e cement
,Sand,1/4'Stone chips etc. will be supplied by the
14 14 "Supply of half size apparatus case (As per RDSO Numbers 12.00 6661.00 79932.00
drawing No. RDSO/S-11507). This includes supply of
location box (GKP type) with 'E' type lock & key, fitted on
location door on both side, E Type lock as per RDSO Drg.
No. SA 3376 and Key to Drg. No. 3377 as per RDSO
drawing No. RDSO/S-11507. Inspection: Consignee "
15 15 "Casting, concreting and curing of concrete foundation Numbers 12.00 2631.36 31576.32
(in ratio 1:3:6), erection and installation of half size
apparatus case (GKP type) Apparatus Case as per
DRG.NO. RE/S&T/SIG/TENDER /SK/8/85 with 'E' type lock
on CC foundation. This includes cost of all materials
required for fixing holding down bolts, casting,
concreting. Note: - bolts, nuts and washers, bitumen
compound to be supplied by contractor and bitumen
compound to be used in between apparatus case and
foundation as per site engineer. This also includes
bottom of apparatus cases filled with sand and the
outside covered with masonry work and neat cement
plastering. Note: - Location boxes to painted with anti-
corrosive paints as per IS: - 9862-1981, one and half feet
from the bottom, on all surfaces-both inside and outside.
Inspection: Consignee. "
16 16 Painting of two coats of synthetic enamel paint over one Numbers 12.00 200.00 2400.00
coat of primer on the following after scraping & cleaning
surface wherever necessary with contractor's own
supply of paints and primer. Note: The paint and primer
should be from Asian Paints/Nerolac/Dulux/Berger. The
primer/enamel paints(Aluminiun synthetic, black
enamel, brilliant white and yellow) will be as per (IS
5660 of 1970)/(IS 2932 of 1974 or latest) of Apparatus
case Half size. (Outside and Inside).
17 17 "Supply of paper base hylam sheet 12 mm thick. Sqm 7.00 4550.85 31855.95
Inspection: consignee."
SEALDAH DIVISION-S AND T/EASTERN RLY
18 18 Fixing of slotted angle and fixing of hylam sheet (Hylam Numbers 12.00 2118.64 25423.68
sheet will be supplied by Rly) for clamping of cable and
fixing of cable joint on the hylam sheet with earthing of
armour of the quad cables including supply of slotted
angles, wires ferrules for marking and miscellaneous
materials per location to be supplied by contractor.
19 19 "Supply of earth electrode mild steel galvanized, Numbers 12.00 1267.80 15213.60
lightclass, IS:1239(PART-I)-1979.earth electrode pipe
should be with 3 mm thick, 50 mm dia and perforated
(staggered), 5 mm dia holes, 2 nos per 305 mm length
with clamp of MS FLAT(galvanised) of size35 mm x 6
mm (SPEC.NO.226 STD). Earth pipe should include CI
threaded cap. Materials to be procured and designed as
per PCSTE/ER'S DRG. NO. SI/TYP/0097 dated 25.03.2025
or latest. Inspection: - Consignee"
20 20 "Supply of MS FLAT (SPEC. NO. 226 STD or latest) ofsize Numbers 12.00 772.03 9264.36
35 mm x 6 mm with length 5 mtr with holes of 12mm
dia at both ends as per PCSTE/ER'S DRG. NO.
SI/TYP/0097 dated 25.03.2025 (or latest). Note: (The MS
flat with holes may be supplied in equivalent length in
mtrs or as per site requirement). Inspection :
21 21 Fixing of earth electrode including laying and installation Numbers 12.00 983.90 11806.80
of MS flat of size 35 mm x 6 mm with length 5 mtr or as
per extant practice of Eastern Railway. As per
PCSTE/ER'S DRG. NO. SI/TYP/0097 dated 25.03.2025 or
latest for apparatus cases, signal post & other
equipment as per instruction of site engineer. Fixing of
MS flat at apparatus cases/ signal post/other equipment
should be made by the firm at site. Full threaded bolts of
10 mm dia and length 40 mm should be welded in the
apparatus cases in such way that the MS flat at
apparatus case end can be fixed from outside or from
inside. Welding arrangement with accessories and
welding materials should be arranged by the contractor
for fixing of bolts at equipment end where required as
per instruction of Rly. site engineer. All hardware and
other miscellaneous materials required for installation to
be supplied by the contractor except earth electrodes
22 22 "Supply,installation and jointing of Thermo shrink Numbers 45.00 2661.86 119783.70
Universal Jointing kit for Quad Cable/PIJF cable as per
RDSO spec IRS/TC-77/2012 revision 3 and with latest
Amdt. The jointing is to be housed in location box as per
Technical Policy Circular No-107. Inspection: RDSO"
23 23 "Supply of Polyethylene insulated underground railway Kilometre 7.00 241504.00 1690528.00
jelly filled telecom 6-Quad cable of 0.9 mm dia. for S&T
installations as per spec no. IRS:TC 30-2005 Ver 1.0
amendment -5 or latest. Inspection: RDSO"
24 24 "Supply of 20 pair Polythene Insulated Polythene Kilometre 7.00 195500.00 1368500.00
sheathed armoured Jelly filled Telephone cable with
Poly-AL moisture barrier 0.63 mm dia as per
specification No. IRS:TC-41-97 or latest. Inspection :
25 25 Supply of 24 Fibre armoured underground Optic fibre Kilometre 3.00 55250.00 165750.00
cable as per RDSO/SPN/TC/110/2020 Rev.: 0 or latest.
Make: Finolex/Birla or Superior. Inspection : RDSO
26 26 "Supply of 6 Fibre armoured underground Optic fibre Kilometre 3.00 35294.92 105884.76
cable, conforming to TEC Spec.No.
GR/OFC02/03.SEP.2003 or Latest. Make:
Finolex/Mescab/D-Link or Superior Inspection:
27 27 "Supply of 10 pair switchboard indoor copper cable 0.6 Metre 3500.00 41.53 145355.00
dia as per TEC/GR/WIR-06/03. MAR 2002 with latest
Amendments. Make: Finolex/Polycab/Mescab or superior
Inspection: Consignee. "
28 28 Supply of 20 pair 0.4 mm switch board cable as per Metre 1000.00 89.23 89230.00
TEC/GR/WIR-06/03. MAR 2002 with latest Amendments
.Make: Finolex/Polycab/Mescab or superior. Inspection :
29 29 "Supply of STP (Shielded Twisted Pair) CAT-6 cable shall Boxes 10.00 5801.00 58010.00
be compliant with latest EIA/TIA- 568-B.2-1 standard or
latest (1 Box = 305 Mtrs) Make- D-Link/Digisol or
superior. Inspection:Consignee"
SEALDAH DIVISION-S AND T/EASTERN RLY
30 30 Supply of power cable 3 core 2.5 sq mm multi strand Metre 4100.00 51.69 211929.00
(50/0.25 mm dia) cable as per IS 694:1990 reaffirmed
1995 or latest suitable for railway electrification area.
Make: Havells/Polycab/Mescab or superior. Inspection :
31 31 "Supply of 2 core screened/shielded multistrand PVC Metre 3500.00 29.66 103810.00
insulated wire (24/0.2 mm dia) for speaker load line.
Make: Havells/Polycab/Mescab or superior. Inspection :
32 32 Laying of Power Cable/STP/UTP CAT-6/Switch Board Metre 16000.00 16.10 257600.00
Cable/speaker cable/Earth Cable etc. through flexible
PVC Conduit Pipe/ GI Pipe/HDPE Pipe (where necessary)
as per direction of the Rly. Representative. Note-This
also includes Laying of STP/UTP CAT-6 from Relay
room/OFC to SM Panel room for Block circuits as per the
site/station, Earth cable as instruction of railway
representative & Laying of Power cable for VSS locations
or any as per instruction. Cable will be supplied by
33 33 "Supply PVC conduit pipe of size 50 mm dia. Min 3 mm Metre 50.00 65.25 3262.50
thickness with ISI mark, Make: Supreme/Polycab/Jindal
or Superior. Inspection : Consignee"
34 34 "Supply of conduit pipe size 25 mm dia min. 2 mm Metre 15050.00 24.80 373240.00
thickness with ISI mark. Make: Supreme/Polycab/Jindal
or Superior. Inspection : Consignee."
35 35 Fixing of PVC conduit pipe on wall, bridges, platform Metre 15000.00 5.27 79050.00
shed complete with 'U' clamps and necessary fixture
screws etc. as per route given by site engineer of
Railways. Note- PVC pipe will be supplied by railway.
36 36 "Supply of rolled flexible PVC Pipe of 25 mm dia. Metre 300.00 24.25 7275.00
Inspection: Consignee"
37 37 Supply & installation of G.I. Perforated Type Cable Tray Metre 150.00 629.62 94443.00
with all accessories like Tees, elbow, reducers, couplers
etc. Cable Tray Sheet Thickness: 2.5 mm, Cable Tray
Width: 300mm, Cable Tray Height (mm): 50 as per Drg
No. SK/SDAH 2025/01 dated:25.07.2025 or latest
Inspection: Consignee
38 38 Supply of 40 mm dia permanently lubricated HDPE Kilometre 9.20 53277.12 490149.50
telecom: ducts (with chord) as per RDSO SPEC.NO.
RDSO/SPN/TC/45/2013 REVISION 2.0 with latest
amendments or Latest in length of 1000 mtrs/roll For
each km. Of HDPE duct following items are to be
supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2
nos. (c) plastic couplers slip fit/push fit type-2 nos. (d)
end plugs to be provided along with drum 2 nos. (Note:
The color of duct will be as per Technical circular -124.
For station area the color of HDPE duct will be brown.
The colour of the duct is to be confirmed by the in-
charge of the work before supply) Inspection: Consignee
39 39 Laying of HDPE pipe duct, 40/33 mm in trenches Kilometre 9.00 20961.02 188649.18
/overhead and protective works including pulling of
mono-mode armoured OFC cable through duct in
trenches and as advised by site engineer. Note:- (1) the
contractor will take over the OFC cable from railway
store to site of work duly checked the continuity of each
fibre from end to end . (2) before & after laying of optical
fibre cable through duct, continuity test from end to end
of each fibre to be made by the contractor to ensure
availability of all duly certified by the site engineer.
Note: OFC & HDPE Duct will be provided by railway.
40 40 Over head laying of 6-core OFC cable along with Metre 200.00 35.37 7074.00
FOB/Wall/shed structure etc. including clamping/fixing
the PVC conduit over wall ceiling/open
space/terrace/existing fixtures etc. as per directives of
Rly. Site engineer.
SEALDAH DIVISION-S AND T/EASTERN RLY
41 41 Earthwork in filling in embankment, guide bunds, around cum 10.00 124.58 1245.80
buried type abutments, bridge gaps, trolley refuges, rain
bunds if provided, platforms etc. with earth excavated
from outside railway boundary entirely arranged by the
contractor at his own cost as per RDSO's latest
guidelines and specifications and special condition of
contract including all leads, royalty, lifts, ascents,
descents, crossing of nallahs or any other obstructions.
The rates shall include all dressing of bank to final
profile, demarcation and setting out of profile, site
clearance, removing of shrubs, roots of vegetations
growth, heavy grass, benching of existing slope of old
bank, all handling/re-handling. Taxes, Octroi and royalty
etc. as a complete job. Cut trees shall be property of
railways and to be deposited in the railway godown
unless specified otherwise in the Special conditions of
42 42 Repair of pucca roads to original state in level/ Road Metre 100.00 216.95 21695.00
crossing area after cable laying. All required material for
repairing will be arranged by firm by their own cost
43 43 "Supply of Double Walled Corrugated (DWC) HDPE Numbers 5.00 576.27 2881.35
Pipe/duct with associated collars etc. as per RDSO
Specification No. RDSO/SPN/204/2011 ver 1.1 or latest
with latest ammendments anti-rodent & anti-oxidant and
non-flame propagating type in 6 meters straight length
and of size 120 mm outer dia& 103.5 mm inner dia. (The
manufacturers, suppliers must produce valid IS license
and should be certified under ISO 9000 and shall submit
copy of certificate). One of the following coupling
arrangements should also be supplied with each pipe as
per the site requirement. 1) Suitable snap fit coupler
with rubber O-Ring 2)Spacers, 3)Tees, 4)Bend, 5)End-cap
(The total quantity of above items is equal to no. of pipes
supplied.) DWC pipe shall be marked at every 1 mtr.
length in such a way that manufacturer's name, vendor
name and year of manufacture can be easily identified.
Inspection: Consignee "
44 44 Placing of DWC HDPE/RCC/GI pipes along with collars in RMT 30.00 26.27 788.10
trenches at places near track and road, crossings,
platform cuttings etc.
45 45 Cement concrete work for miscellaneous items in the cum 50.00 3047.46 152373.00
ratio 1: 3: 6. Item includes excavation, ramming, curing
and plastering with cement & sand mixture (aggregate
not exceeding 3.8 cm.) (Aggregate cement & sand to be
supplied by the contractor). Wherever depth of 0.5 m
cable trench is not feasible, cable shall be protected as
:- Preparation of cement mixture 1:3:6 with contractor's
own materials and spreading cement concrete mixture
layer of 100 mm thick over the already laid cables in the
excavated trench.
46 46 Supply and installation of Telecom Console Numbers 1.00 50000.00 50000.00
Unit/Customized rack for installation of all telecom
equipment, telecom cable and telecom power supply in
one unit/customized rack consisting of front and back
panel as per Technical policy circular-113. (Note: The
console unit should be made of CRCA steel sheet with
ivory colour powder coated finish and should have
locking and sealing arrangement. The dimension of
console unit is to be supplied as per the site
requirement) Inspection: Consignee
SEALDAH DIVISION-S AND T/EASTERN RLY
47 47 "Supply of basic material to construct unit maintenance Lot 8.00 12836.44 102691.52
free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0
or latest and conforming to RDSO Drg. No. SDO / RDSO/
E&B/001 or Latest. and RDSO Doc. No. RDSO-SIG0SPD
STS/E/TAN/3006 ver 3.1 or latest. Necessary testing
certificate of UL, IEC to be produced. It consist of
following: (a) Copper bonded steel electrode of 3.0 m
long, 17.2 mm dia with copper bonding thickness of
minimum macrons and UL listed and marked = 1 no. (b)
Earth enhancement material supplied in sealed bags of
minimum 10 kg = 3 nos. (c) Copper strip of 200x25x6
mm, to terminate earth rod = 1 no. (d) Copper strip of
300x25x6 mm (MEEB) = 1 no. (e) Copper strip of
150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm
multi strand single core PVC insulated copper cable as
per IS: 694 for connecting main earth electrode to MEEB
in the equipment room (4nos.) (minimum 10 meter and
as per site requirement) (iii) Supply of 16 sq. mm multi
strand single core PVC insulated copper cable as per IS:
694 for connecting MEEB to SEEB and SPD to MEEB
(minimum 10 meter) (iv) Supply of 10 sq. mm multi
strand single core PVC insulated copper cable as per IS:
694 for connecting various equipment to SEEB (v)
Supply of copper lug sleeve for 3/16 cable Inspection:
48 48 "Installation of Unit Maintenance Free Earth as supplied Set 8.00 5575.42 44603.36
in above item. It includes ( i ) Digging the earth to the
required depth.(ii) Insertion of electrode. (iii) Filling of
earth enhancing compound (Approx.30 Kg)(iv) Provision
of exothermic weld connections to copper tape of 25
mm x 6 mm x 200 mm to the earth electrodes. All
material tools and features requiredfor weld will be
arranged by contractor. (v) This also includes CC cover
1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch
thickness. Cables 35 Sq mm/ 16 Sq mm/10sqmm
forconnecting earth to busbar, busbar to busbar and bus
bars to various equipment. Earth electrode of 17.20 mm
dia and 3.00 meter long high tensile low carbon steel
circular rods molecularly bonded with copper and outer
surface (minimum copper bonding thickness of 250
microns to made requirement of under writer's
laboratories (UL) 467-2007 or latest. Copper strips of
200 mm x 25 mm x 6 mm to be welded with each earth
electrode, copper strips of 300 mm x 25 mm x 6 mm for
main equip- potential bus bar, copper strips of 150 mm
x 25 mm x 6 mm sub equip-potential bus bar in relay
room, power room, OFC room and panel room. The
distance between the MEEB and the SPD box should not
be more than 0.5 mtrs. Inspection chamber of site 300
mm x 300 mm x 300 mm (Inside dimension) of
approximate 50 mm thick with pulling hooks to cover the
earth pits. Note: The installation of this item shall be
carried out as per RDSO Specs. No RDSO/SPN/197
Ver.1.0 or latest and conforming to RDSO Drg. No. SDO /
RDSO/ E&B/001 or Latest. and RDSO Doc. No. RDSO-
SIG0SPD (PROJ)/1/2020 dated 01.01.2025 or latest.
STS/E/TAN/3006 ver 3.1 or latest "
49 49 "Supply of optic fiber splice closure (24 fiber) as per tec. Numbers 35.00 3015.25 105533.75
Specification no. TEC/GR/TX/OJC-002/03/APR-2010 or
latest with latest amendment including all miscellaneous
items and consumables for fiber splicing. Inspection:
50 50 Jointing, terminating & splicing of 24 fibre optic fibre Numbers 37.00 9004.24 333156.88
cable and fixing of termination box/FDF/placing of joint
closures in the pit required at various locations including
transportation of all the jointing & terminating materials
from railway store to the work site and returning leftover
materials to the railway store. Note:Jointing/Splicing of
Cables/OFC for permanent restoration of cables/OFCs at
any time wherever instructed. Note-Splice closure will
be provided by railway.
SEALDAH DIVISION-S AND T/EASTERN RLY
51 51 Excavation of OFC pit for OFC cable jointing of size 1.5m Numbers 35.00 5655.93 197957.55
x 1.5m x 1.2 m or as per site requirement for all type of
soils. Back filling the pit and ramming after jointing.
Provision of brick walling the four walls and bottom of pit
with RCC slab, with bottom & top cover with holes for
drainage and cable entry with filling of dry sand mixed
with anti-termite chemical up to 400mm height. Note: All
the materials including cement,Bricks, sand etc.
required for the above will be supplied by the tenderer.
52 52 Supply & Execution/Installation of 20 pair CT Box with 40 Numbers 80.00 1713.81 137104.80
Nos (1 in 1 out) Wago Terminal properly fixed on carrier
rails with end plates and end stopper inside the CT box
for termination of PIJF/Quad cable .Note- As per
Technical policy circular no. 110, the twisting of
Quad/PIJF cables to be done before termination at
location boxes/CT rack/OFC room/SM Room/CT boxes.
Soldering/Tinkering of armour earthing to be done.
Inspection : Consignee
53 53 "Supply of Fiber Distribution Management System 24 Numbers 12.00 7826.00 93912.00
port, Single Mode, Simplex Fiber Optic Patch Panels,19
inch 1 U Rack Mountable with SC connector with all
accessories. Make: Syrotech/Commscope/Digisol or
superior Inspection: Consignee."
54 54 "Supply of Fiber Distribution Management System 12 Numbers 6.00 7011.19 42067.14
port, Single Mode, Simplex Fiber Optic Patch Panels, 19
inch 1 U Rack Mountable with SC connector with all
accessories. Make: Syrotech/Commscope/Digisol or
superior Inspection: Consignee. "
55 55 Installation of LIU/FDMS and termination as per site Numbers 16.00 298.53 4776.48
56 56 Splicing /Dropping/Termination of each Fiber /Pigtail in CORE 400.00 44.83 17932.00
the LIU/FDMS through fusion Splicing of the termination
of OFC Cables, as per the instructions of Railway site
57 57 Testing of all fibres o f t h e optic fibre cable, quad, PIJF Station 1.00 9036.44 9036.44
cable, ADMS, mux and other accessories installed above
and final commissioning of optic fibre communication link
conforming t o railway's specification including e n d to
end testing for realisation of optic fibre system.
58 58 Supply, installation and complete indoor wiring of 19 Numbers 1.00 31838.98 31838.98
inch (42U) covered Rack of size 2035 mm x 600 mm x
600 mm (Approx.)(a).Size of Server Rack Enclosure :
42U (b) Type of Server Racks : Rack Enclosures.(c) Rack
Size(mm) : 2035 mm x 600 mm x 600 mm (Approx.). (d)
Mount Type : Floor mount (e) Front glass Door : Yes. (f)
Secure Locks : Available (g) Support cable entry from top
or bottom : Yes (h) Vertical & Horizontal managers : Yes
(i) Numbers of Rack trays : 2 (j) Number of Fan For Heat
dissipation (nos) : 4 (k) Number of fan trays : 4 (l) PDU
Power Strips : 1 with 6 Sockets. The rack shall be
complete with all fittings for housing SDH equipments,
Primary MUX, DDF, MDF using krone modules and other
required accessories. Make: HCL/VALRACK or superior,
Inspection: Consignee
59 59 "Supply of wall mount 9U Rack Enclosures Numbers 12.00 7239.02 86868.24
Networking/Server Rack with power strip 5A socket 06
no. & 01 MCB, Depth of the Rack: Upto 500
mm,Transparent Toughened Glass used in front door,
CRCA Steel rear door with Secure Locks,Cable Manager,
Support cable entry from top or bottom, with fan tray
and two nos. fans. Make: Valrack/Netrack/Dynamic/D-
Link or similar Inspection: Consignee. "
60 60 "Supply of 6U wall mounted rack with power strip 5A Numbers 10.00 3605.85 36058.50
socket 06 no. & MCB, Depth of the Rack: Upto 400mm,
Transparent Toughened Glass used in front door, CRCA
Steel rear door, with Secure Locks, Support cable entry
from top or bottom, with fan tray and min. 02 nos. fans.
Make: Valrack/Netrack/Dynamic/D-Link or similar.
Inspection: Consignee. "
SEALDAH DIVISION-S AND T/EASTERN RLY
61 61 "Supply of wall mount 4U Rack with power strip 5A Numbers 10.00 3919.60 39196.00
socket 06 no. & MCB, Depth of the Rack: Upto 400mm,
Transparent Toughened Glass used in front door, CRCA
Steel rear door, with Secure Locks, Support cable entry
from top or bottom, with fan tray and min. 01 nos. fans.
Make:Valrack/Netrack/Dynamic/D-Link or similar.
Inspection: Consignee. "
62 62 Installation of 9U/6U/4U rack with necessary angles, Numbers 32.00 469.54 15025.28
fasteners and other fixing arrangements.
63 63 "Supply,Installation & Commissioning of Telecom TDM Pair 8.00 53344.50 426756.00
Multiplexer Rack Mountable Device consisting of one E1
port, Two V.21 /V.23 (E&M) 2W/4W interfaces with auto
change over mechanism to Quad ports 2W/4W ; each
port configurable as 2W or 4W no restriction in
configuration ; Automatic change over of the data traffic
between two axle counters if the E1 Link between the
Axle counter fails then will switch over to the copper
automatically. If the Power to the Converter Fails then It
also Automatically changes the data transportation over
the copper link.Potential Free contacts for indicating the
events E1 Link UP, E1 Link DOWN, V.21 Signal UP and
DOWN between two axle counters. 48 VDC power
s u p p l y. Make/Brand:TEAMLINK FABIO-1CX/MRO-TEK-
MAPLE or similar. Inspection: Consignee"
64 64 "Excavation of cable trench as per cable route plan, 1.2 cum 1800.00 207.63 373734.00
Mtr. deep and of 0.3 Mtr. wide at bottom without brick
as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG,
SK/8/95/NKG. or latest alongside the track in all kinds of
soil, conforming to distances as per cable route plan and
refilling. This work includes clearing of route from
bushes etc. The work shall be done as per the extant
practice on Eastern Railway and instructions of Railway
Engineer at site. Note:-(a)for all trenches from distant
signal to home signal and to relay room, the minimum
headway above the uppermost cable in the trench
should be 600mm. If due to a large no. Of cables
headway is not available, 4"" of 1:2:4 concreting should
be done. Note:-(b-1) payment will be made as per actual
work done on pro-rata basis, if required depth is not
available at site. (b-2) if the depth of trench is not
uniform in a span of 100 mtr. Or shorter lengths if site
condition demands along the cable run, minimum depth
will be taken for that particular stretch for payment. "
65 65 "Supply of Armoured Duplex Fiber Optic Patch Cord 3 Numbers 150.00 1271.19 190678.50
meters (LC-SC/SC-SC/LC-LC/FC-LC) as per site
requirement.Outer Jacket: PVC or LSZH, Mode:Single,
Durability: 1000mate/demate cycles, Nominal
Wavelength : 1310 nm, Fibre Attenuation: < 0.38 dB/Km
at 1310nm, < 0.25 dB/Km at 1550 nm, Insert
Loss/connector: Maximum 0.1dB per connector plus fibre
loss,Return loss : Better than 45dB Make:
Iveonet/Relemac or superior Inspection: Consignee"
66 66 Supply of Universal 2/4 wire way side DTMF control Numbers 38.00 4409.32 167554.16
telephone as per RDSO spec. no. IRS: TC:82: 2005 (with
Amdt. 3) or latest. Make-Bentron/ EPSILON or similar.
Inspection: Consignee
67 67 "Supply of power supply unit for telecom installation at Numbers 45.00 3169.49 142627.05
way side station suitable to operate max 6 equipments
of DTMF type (12V/7AH) battery with suitable battery
charger) as per RDSO spec. No. IRS: TC-72-97 or latest.
Make-Bentron/ EPSILON or similar Inspection:
68 68 Supply of 4W way station DTMF equipment as per RDSO Numbers 33.00 5686.44 187652.52
spec. no IRS : TC : 60 /2007 (DECODER) or latest.Make-
Bentron/ EPSILON or similar. Inspection: Consignee
69 69 Installation of 4W way station DTMF equipment & 4 wire Numbers 5.00 1065.25 5326.25
telephone.Required fixing arrangements to be done by
SEALDAH DIVISION-S AND T/EASTERN RLY
70 70 Supply of standard 19"rack mountable , -48V DC Numbers 1.00 168837.29 168837.29
working, Add-Drop STM-4 SDH equipment conforming to
GR No. TEC/GR/TX/SDH - 010/03.Jan 2011 or latest
amendment, complete with redundant power supply, 2
no. STM 4 of aggregate L.4.2 Optical interface
modules/Cards one each for East and west side, TX/RX
and 2 nos. of STM-1 S 1.1 optical interface modules
complete with 5 mtrs long optical fibre cords, 21 E1s
with DDFs and cable assembly for termination to DDF
and minimum 8 nos. of 10/100 Base-T Ethernet ports,
Fast Ethernet on SDH [EoS] 10/100 Base-I interface
module/card supporting with LCAS and GEP, order wire
subrack DDF installation material, manuals and other
accessories. Complete Engineering order wire (EOW)
arrangement. Necessary/Firmware for local/remote
monitoring/configuration of the equipment through EMS
and Software/Firmware interface to work all Network
elements as Gateway Network Element [GNE], 2 nos of
MCBs of appropriate rating and necessary connecting
cords and cables for power supply modules. Inspection:
71 71 Installation and commissioning of STM-4 in the existing Numbers 1.00 19911.02 19911.02
rack with ready infrastructure or in new rack as desired
by the site Engineer.
72 72 "Supply of 2 MB Programmable Primary Digital drop Numbers 5.00 126532.20 632661.00
insert multiplexer as per RDSO Specs. IRS:TC: 68-2012
Amdt. 1 or latest with conference facility and other
stipulation to tender documents and fully wired for 30
channel complete with power supply card, remote
control, supervision facility and all other accessories,
installation material, manuals etc. It should have
facilities to accommodate data interface card in multi
drop mode and should be able to support cards needed
for video conferencing and ISDN. It shall support NMS
installed at Test Room and may operate local/remote
location of entire section. It also includes submission of
all technical documents, manuals and supply of all
miscellaneous items which will be required for final
testing and commissioning of system. The above MUX
should be equipped with following circuits: -i) 2 wire/ 4
wire E&M VF circuits ( minimum 16 nos ckts)ii)
Subscriber loop circuits ( minimum 4 nos ckts iii)
Exchange loop interface circuits (minimum 8 circuits ) iv)
This also includes connecting all pigtails, optical patch
cords etc. to the SDH equipments. This also includes
connection of SDH and primary MUX equipment with all
interface cards to the 48V Bus including supply of wires
and connectors termination of all evens on DDF taking
PVC cable over runway or a wall and termination of VF
interface circuit to the Krone type. Inspection: RITES"
SEALDAH DIVISION-S AND T/EASTERN RLY
73 73 Installation, wiring, testing and commissioning of 2 MB Numbers 2.00 9637.29 19274.58
Programmable Primary Digital drop insert multiplexer as
per RDSO Specs. IRS:TC: 68-2012 Amdt. 1 or latest with
conference facility and fully wired for 30 channel
complete with power supply card, remote control,
supervision facility and all other accessories, installation
material, manuals etc. It should have facilities to
accommodate data interface card in multi drop mode
and should be able to support cards needed for video
conferencing and ISDN. It shall support NMS installed at
test Room and may operate local/remote location of
entire section. It also includes submission of all technical
documents, manuals and supply of all miscellaneous
items which will be required for final testing and
commissioning of system.The above MUX should be
equipped with following circuits: -i) 2 wire/ 4 wire E&M VF
circuits ( minimum 16 nosckts)ii) Subscriber loop circuits
( minimum 4 nosckts)iii) Exchange loop interface circuits
(minimum 8 circuits )iv) This also includes connecting all
pigtails, optical patch cords etc to the SDH equipments.
This also includes connection of SDH and primary MUX
equipment with all interface cards to the 48V Bus
including supply of wires and connectors termination of
all evens on DDF taking PVC cable over runway or a wall
and termination of VF interface circuit to the Krone type.
All materials such as wires for Earthing & power supply,
wire carrying aluminium
ladder,MCB,Connectors,foundation bolts,nuts,base
frame,mounting accessories for fitting of
transformers,U-Link Panels,inter connecting cables etc.
required for the above shall be supplied by the
74 74 Supply of Subscribe loop interface cards, minimum 4 Numbers 14.00 10383.05 145362.70
circuits per card as per RDSO Specs. IRS:TC: 68-2012
Amdt. 1 or latest for existing WEBFIL PD MUX. Inspection
75 75 Supply of 2W/4W E&M interface cards, minimum 4 Numbers 14.00 10189.83 142657.62
circuits per card as per RDSO Specs. IRS:TC: 68-2012
Amdt. 1 or latest for existing WEBFIL PD MUX. Inspection
76 76 Supply of Exchange loop interface card, 4 circuits per Numbers 8.00 6907.63 55261.04
card as per RDSO Specs. IRS:TC: 68-2012 Amdt. 1 or
latest. for existing WEBFIL PD MUX Inspection :
77 77 Supply of surge suppressor for all the 30 circuits derived Numbers 4.00 5554.24 22216.96
from the Primary MUX (Z protection). (Note: The unit
(no.) denotes a set of surge suppressor required for all
the 30 circuits derived from primary MUX) Inspection:
78 78 Supply of 8/6 port (100/10 base T) ethernet interface Numbers 1.00 43120.40 43120.40
card for SDH ADM STM-4 suitable for STM-4 (Model-TJ
1400). Inspection : Consignee
79 79 Supply of NIM card as per RDSO spec no. IRS-TC-68/2012 Numbers 14.00 22595.60 316338.40
or latest and suitable for existing WEBFIL PD MUX.
Inspection : Consignee
80 80 Supply of Tributary module card as per RDSO spec no. Numbers 14.00 34369.56 481173.84
IRS-TC-68/2012 or latest and as per suitable for existing
WEBFIL PD MUX. Inspection : Consignee
81 81 "Supply and installation Of 32U(600X600mm) Floor Numbers 4.00 28500.00 114000.00
Mount Network Rack with PDU of 6 Socket (15/5 amp
socket), Server Tray (3 Nos), Cable Organiser 1U Closed,
4 Fan with all required accessories. Make:
Valrack/Netrack/Dynamic/D-Link or superior. Inspection:
82 82 "Supply of Magneto telephone, desk type as per spec. No Numbers 24.00 2935.35 70448.40
IRS/TC-79/2000 Amdt. 4 or latest with all accessories
Make: Epsilon/Anu Vidyut or superior. Inspection:
83 83 "Supply of 8 lines annunciator for Magneto Phones. Numbers 4.00 7184.74 28738.96
Make- EPSILON or superior. Inspection- Consignee"
SEALDAH DIVISION-S AND T/EASTERN RLY
84 84 "Supply of Master telephone with voice recording facility Numbers 5.00 42348.00 211740.00
of Electronic LC gate telephone systems with voice
recorder as per RDSO SPEC.NO.RDSO/SPN/TC/51-2021
REV 1.0 or latest. Material to be supplied from RDSO's
approved source only with 03(three) years full
warranty.Note: - 1) The date of manufacture of the item
should be of current year at the time of supply to railway
stores. Inspection: RDSO"
85 85 "Supply of Gate (slave) telephone as per RDSO Numbers 10.00 4415.00 44150.00
SPEC.NO.RDSO/SPN/TC/51-2021 REV 1.0 or latest
Material to be supplied from RDSO's approved source
only with 03(three) years full warranty. Note: - 1) The
date of manufacture of the item should be of current
year at the time of supply to railway stores. Inspection:
86 86 "Supply of 24V Power supply unit with MF Battery and Numbers 10.00 5706.00 57060.00
Charger for Master Telephone As per RDSO
SPEC.NO.RDSO/SPN/TC/51/2021 REV 1.0. or latest. Note:
PSU should have another output of 12 V + 0.5 V, with
current capacity of minimum 500 mA for local use of
Station Telephone Unit. Inspection : RDSO "
87 87 Supply of cylindrical type V.F. transformer Numbers 54.00 620.34 33498.36
1120:600/470:1120 as per IRS/TC/76-2021 ver. 01 or
latest. Note: The transformers (1120:600/470:1120) to
be supplied as per the site requirement. Inspection -
88 88 Installation of V.F. Transformer 1120:600/470:1120 to Numbers 4.00 380.20 1520.80
the site given by the railway representative.
89 89 "Supply, Fixing and wiring of 20 Pairs Krone type D.P. Numbers 4.00 1007.72 4030.88
Box with krone Module, the box should be Powder
Coated Material - Metal (MS). Inspection: Consignee"
90 90 Supply of SMPS based Battery Chargers as per RDSO Numbers 1.00 78583.05 78583.05
Spec for Telecom use 48 volts, 25 Amps in 2+1
configuration modules of 25 Amps with ultimate
expandable capacity 50 Amps, automatic switching
between the modules as per RDSO Spec No.
RDSO/SPN/TL/23/1999 version 4 or latest along with two
potential free contacts. Make- Statcom/Amara Raja or
superior. Inspection: RDSO
91 91 Installation of Battery chargers, Power distribution Board Numbers 1.00 3879.66 3879.66
along with MCBs of suitable ratings and wiring and
commissioning of External alarm contacts through NMS
& earthing of SMPS based Chargers to nearest
SEEB(10sqmm earth cable green color will be provided
by contractor). The work includes supply of MCBs, lugs
and other accessories required for installation of power
plant. Inspection: Consignee
92 92 Supply of 48Volt/200AH maintenance free VRLA Numbers 1.00 75756.77 75756.77
Batteries duly charged as per IRS Spec. No. S-93/96(A)
with amendments-1 or latest. Inspection: RDSO
93 93 Installation, wiring, testing & commissioning of Numbers 1.00 16328.81 16328.81
48Volt/200AH maintenance free VRLA Batteries duly
charged as per IRS Spec. No. S-93/96(A) with
amendments-1 or latest.The work includes supply of
battery rack, min. 20Mtr of 16sq.mm power cable with
lugs for connecting load & battery through the charger,
battery lugs and other accessories required for
installation of power plant. Make: Amara Raja/Exide or
superior. Inspection: Consignee
94 94 "Supply of RR Cell, 1.5V/45 AH. Make: Spark/Tiger or Numbers 50.00 624.70 31235.00
superior. Inspection: Consignee."
95 95 "Supply of 12V,10A SMPS Based power supply unit Numbers 20.00 6212.03 124240.60
suitable for 25W VHF set. Make-Axiom/Bentron or
superior. Inspection: Consignee."
96 96 "Supply of MCB 16A, Double Pole,DIN Rail Mount. Numbers 50.00 343.30 17165.00
Make:Havellls/Schneider or superior. Inspection:
97 97 "Supply & installation of 12 Volt, 120 AH single unit MF Numbers 2.00 12500.00 25000.00
battery for 25W VHF set. Make- Exide/Amaron/Quanta or
superior Inspection : Consignee"
SEALDAH DIVISION-S AND T/EASTERN RLY
98 98 Supply & Installation of DC-DC converter for emergency Numbers 2.00 17577.97 35155.94
communication through V.H.F. as per specification - the
DC DC converter shall be independent for each vhf base
equipment (voice equipment) and shall allow t o work
from -48V nominal input (-48V to -60V variation) & output
12V DC. The power capacity to deliver 10A current with
output short circuit protection & ripple voltage less than
5mv for telecom circuit. Short circuit current not more
than 2 mA, input-output insulation by 2.5 KV, load &
output regulation +/-1% with ERTL certification.
Make:VERON/DACS/Machronics or superior. Inspection:
99 99 Supply of Buffer amplifier for emergency communication Numbers 2.00 11726.27 23452.54
through V.H.F. As per voice frequency channel shall be
6 0 0 ohms balanced 4 W (viz. 2 W f o r transmit, 2 W for
receive) and 2W for E&M signalling. The nominal voice
frequency signal shall be 0 dbm level the buffer amplifier
should work of -48V DC or can from the DC-DC converter.
B u r n i n o f t h e complete equipment a t 5 5 degree
centigrade to avoid infancy failures. During the test the
equipment shall be kept continuously on.
Make:VERON/DACS or superior. Inspection : Consignee.
100 100 "Supply of Floor mounting surge supressure(4 Nos. Of Numbers 1.00 9552.19 9552.19
16A Socket in each strip), protection should be provided
in each socket separately, Weather proof light gray color
M.S. enclosure, Normal input voltage:230VAC,+/- 10%
Single phase, 50-60 Hz, Input AC cord: 6 ft. 3 core 15
amps. One ANCHOR/Havells make 16 amps top to be
provided at one end of the mains cord, LED indication:
One 5mm red LED for power ON, One 5mm green LED
for protection present., Output Termination: 4 Nos.16
amps socket of anchor make to be provided, Thermal
cutoff: 16 amps MCB to be provided, make: Rockware or
Superior, Inspection: Consignee."
101 101 Supply, Fixing and wiring of 10 Pairs Krone type D.P. Box Numbers 6.00 685.59 4113.54
with krone Module, the box should be Powder Coated
Material - Metal (MS). Inspection: Consignee
102 102 Supply of UTP CAT-6 cable as per EIA/TIA- 568-B.2-1 Metre 915.00 16.10 14731.50
Make: D Link/Molex/Comscope or superior. Inspection:
103 103 "Supply of MCB 10A, single Pole, DIN Rail Numbers 30.00 106.26 3187.80
Mount.Make:Havellls/Schneider or superior Inspection:
104 104 "Supply of MCB 06A, Double Pole, DIN Rail Mount. Numbers 10.00 310.60 3106.00
Make:Havellls/Schneider or superior Inspection:
105 105 "Supply of Small Form- Factor Pluggable (SFP) as per Pair 29.00 9806.10 284376.90
IEEE standard: IEEE 802.3z,Connector type: LC
type,Wavelength(nm): 1310 nm, Fibre type: Single
mode, Max cable distance: upto 20 km.To be suitable for
Datacom equipment/ STM-1 & STM-4 supplied as per site
requirement. Make:DIGISOL/Netgear/Cisco or superior
(to be suppied in pair) Inspection: Consignee."
106 106 "Supply of 250 watt Amplifier Make Ahuja/NEXA or Numbers 16.00 9239.83 147837.28
superior Note: The supplied amplifiers should have USB
support. Inspection: Consignee"
107 107 "Supply of 500 watt Amplifier Make Ahuja/NEXA or Numbers 7.00 22487.29 157411.03
superior Note: The supplied amplifiers should have USB
support. Inspection: Consignee."
108 108 "Supply of 700 watt Amplifier Make Ahuja/NEXA or Numbers 2.00 25583.90 51167.80
superior. Note: The supplied amplifiers should have USB
support. Inspection : Consignee"
109 109 "Supply of 40 W high fidelity PA horn speaker IP-65 rated Numbers 50.00 5180.51 259025.50
including fixtures, Custom mounting bracket and other
material required. Make- Ahuja/BOSCH or superior.
Inspection: Consignee."
110 110 "Supply of 15 watts Horn speaker with 10 watt tapping, Numbers 30.00 1611.02 48330.60
matching transformer and driver unit including fixtures ,
Custom mounting bracket and other material required.
Make- Ahuja/BOSCH/Bose or superior Inspection:
SEALDAH DIVISION-S AND T/EASTERN RLY
111 111 "Supply of column speaker 15W with LMT all metal Numbers 26.00 1294.91 33667.66
weather resistant, including fixtures,Custom mounting
b r a c k e t and other material required. Make-
Ahuja/Bosch/Bose or superior Inspection:Consignee. "
112 112 "Supply of Dynamic Microphone with cord & stand. Numbers 42.00 1426.72 59922.24
Make: Ahuja/Shure/Sennheiser or superior. Inspection:
113 113 "Supply of Microphone Signal Cable : 0.75 Sq. Mm two Numbers 5.00 4900.00 24500.00
core shielded microphone cable. 100 m roll. (1 Roll=1
No.) Inspection : Consignee"
114 114 Supply, Installation, testing and Commissioning of Numbers 10.00 39271.19 392711.90
Platform dual face, 4 digit, GPS synchronised digital
clock as per RDSO spec. RDSO / SPN/ TC /62 /2008 Rev.
4.1or latest with latest ammendments, with LED of
Blue/Red/White colour and size approximately 762 x 381
x 228 mm It also includes all fitting arrangements.
(Colour to be decided by Railways).Inspection: (i)
RDSO/RITES if value of item in work more than 5 lakhs or
as per extant policy.(ii) Consignee subject to
procurement from RDSO approved vendors if value of
whole item in work less than 5 lakhs or as per extant
115 115 "Supply of Digital Clock suitable for Office Complex with Numbers 20.00 11199.15 223983.00
GPS Synchronization in standalone mode as per Clause 6
of RDSO spec. RDSO / SPN /TC /62 /2008 Rev. 4.1 or
l a t e s t It also includes all fitting arrangements.
Inspection: Consignee"
116 116 "Supply of 1 x 6 Sq.mm. (Green) multi strand copper Metre 700.00 35.59 24913.00
power wire as per IS: 694:2010 orlatest, 84 conductor
each dia 0.30mm +/- 0.01 with insulation thickness of
0.8 mm and nominal conductor resistance of 3.3
ohms/km and test parameters as per RDSO
Specn.No.IRS:S- 76/89 (Amnd.3) or latest. Color of the
wire which is required will be specified by the Engineer
in-charge Inspection: Consignee"
117 117 "Supply of 1 x 10Sq.mm. (Green) multi strand copper Metre 700.00 100.85 70595.00
power wire as per IS: 694:2010 or latest, 140 conductor
each dia 0.30mm +/- 0.01 with insulation thickness of
1.0 mm and nominal conductor resistance of 1.91
ohms/km and test parameters as per RDSO
Specn.No.IRS:S- 76/89 (Amnd.3) or latest. Color of the
wire which is required will be specified by the Engineer
in-charge Inspection: Consignee"
118 118 "Supply of 1 x 16 Sq.mm. (Green) multi strand copper Metre 700.00 111.02 77714.00
power wire as per IS:694:2010 or latest, 126 conductor
each dia 0.40mm +/- 0.01 with insulation thickness of
1.0 mm and nominal conductor resistance of 1.21
ohms/km and test parameters as per RDSO
Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the
wire which is required will be specified by the Engineer
incharge. Inspection: Consignee"
119 119 "Supply of 1 x 35 Sq.mm. (Green) multi strand copper Metre 600.00 150.00 90000.00
power wire as per IS:694:2010 or latest, 276 conductor
each dia 0.40mm +/- 0.01 with insulation thickness of
1.2 mm and nominal conductor resistance of 0.554
ohms/km and test parameters as per RDSO
Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the
wire which is required will be specified by the Engineer
incharge. Inspection: Consignee"
120 120 "Supply of Tinned Copper LUGs for fitting in Cable Size: Numbers 1500.00 2.54 3810.00
6 sqmm, Barrel Inner-dia: 4.0mm, Barrel Outter-Dia:
5.5mm, Barrel Length: 10mm, Stud Hole Center-dia:
8.2mm, Palm Width: 10.0mm, Thickness: 1.3-1.5mm,
Lug Length: 24mm,Thimble type: Ring/Fork type as per
site requirement. Inspection: Consignee"
121 121 "Supply of Tinned Copper LUGs for fitting Cable Size: Numbers 1500.00 3.39 5085.00
10sqmm, Barrel Inner-dia: 4.7mm, Barrel Outter-Dia:
7.10mm, Barrel Length: 10mm, Stud Hole Center-dia:
9.9mm, Palm Width: 12.6mm, Thickness: 1.8, Lug
Length: 27mm, Thimble type: Ring/Fork type as per site
requirement. Inspection: Consignee"
SEALDAH DIVISION-S AND T/EASTERN RLY
122 122 "Supply of Tinned Copper LUGs for fitting in Cable Size: Numbers 1500.00 4.36 6540.00
16 sqmm, Barrel Inner-dia: 6.4mm, Barrel Outter-Dia:
8.0mm, Barrel Length: 12.2mm, Stud Hole Center-dia:
10mm, Palm Width: 12.6mm, Thickness: 1.8, Lug
Length: 28-30mm,Thimble type: Ring/Fork type as per
site requirement. Inspection: Consignee"
123 123 "Supply of Tinned Copper LUGs for fitting in Cable Size: Numbers 1500.00 8.73 13095.00
35 sqmm, Barrel Inner-dia:13 mm, Barrel Outter-Dia: 17
mm, Barrel Length: 12.2mm, Stud Hole Center-dia:
10mm, Palm Width: 12.6mm, Thickness: 1.8, Lug
Length: 28-30 mm,Thimble type: Ring/Fork type as per
site requirement. Inspection: Consignee"
124 124 "Supply of Nut Bolts, Washer (Stainless Steel) as per the Set 2200.00 20.00 44000.00
site requirement (One set consists of 1 Nut, 1Bolt , 2
washer & 2 spring washer) Note :- Hex Nuts, bolts and
washers of size 5/16"" Inspection: Consignee"
125 125 "Supply of basic material to construct unit maintenance Numbers 35.00 4000.00 140000.00
free earth as per RDSO/SPN/197 Ver.1.0 or latest and
conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or
Latest. and RDSO Doc. No. STS/E/TAN/3006 Version 3.1
or latest. Necessary testing certificate of UL, IEC to be
produced. It consist of following: (a) Copper bonded
steel electrode of 3.0 m long, 17.2 mm dia with copper
bonding thickness of minimum macrons and UL listed
and marked = 1 no. Inspection: Consignee"
126 126 "Installation of Unit Maintenance Free Earth . It includes Set 35.00 3000.00 105000.00
( i ) Digging the earth to the required depth. (ii) Insertion
of electrode. (iii) Filling of earth enhancing compound
(Approx.30 Kg) (iv) Provision of exothermic weld
connections to copper Strip to the earth electrodes. (v)
This also includes supply of CC cover 1.5 ft x 1.5 ft. 1 ft
wall thickness 2 inch with cover 3-inch thickness
including Painting of Earth Pit As well. All material tools
and features required for weld will be arranged by
contractor. Inspection: Consignee. "
127 127 "Supply of Copper Strip for MEEB/SEEB (25X6)mm Metre 70.00 700.00 49000.00
Inspection: Consignee "
128 128 "Supply of Copper tape for BRC( 25X2) mm. Inspection: Metre 250.00 250.00 62500.00
129 129 "Installation of MEEB/SEEB/BRC with the insulators (As Numbers 700.00 25.00 17500.00
per the instruction of Site Engineer). Fitting materials &
Insulator (Dough Moulding Compound Conical type of
different Size) as per the site requirement to be supplied
by the contractor. Note: 'No' in the unit column indicates
'per insulator' "
130 130 "Supply and Execution of Exothemic Welds for more Numbers 300.00 418.00 125400.00
than 16 sqmm wire. This includes Welding Kit , Welding
Powder, Mould and other necessary materials. Note- No.
in unit column indicates per welding. Inspection:
131 131 "Supply and Execution of Exothemic Welds for upto 16 Numbers 1300.00 316.00 410800.00
sqmm wire. This includes Welding Kit , Welding Powder,
Mould and other necessary materials. Note- No. in unit
column indicates per welding. Inspection: Consignee"
132 132 Construction of cement concrete enclosure for earth Numbers 47.00 483.90 22743.30
electrode as per DRG. NO. PCSTE/ER'S DRG. NO.
SI/TYP/0097 dated 25.03.2025 or latest. This includes
supply of all materials by the contractor required for
cement concrete enclosure duly inspected by consignee.
133 133 "Supply of Earthing powder ( Earth Enhancement Kg 1050.00 47.50 49875.00
M a t e r i a l ) as per Para 8.2 of RDSO Spn. No.
RDSO/SPN/197 or latest Note :- Minimum weight of Bag
should be of 10 KG. Inspection: Consignee "
134 134 Supply of MS Fencing frame for ring earth area, location Metre 250.00 2540.00 635000.00
box and other S&T premises as per DRG. No. CWM
00223 or latest. (Height of fence would be of 1.5m)
Inspection: RITES
SEALDAH DIVISION-S AND T/EASTERN RLY
135 135 "FIXING OF FENCE AROUND THE RING EARTH AREA AND Metre 250.00 400.00 100000.00
OTHER MISCELLANEOUS WORKS TO BE EXECUTED. THIS
JOB INCLUDES CUTTING AND WELDING OF MS GRILL ,
DRILLING, CEMENT CONCRETING. THIS WORK TO BE
EXECUTED IN ONE RING EARTH AREA AS PER THE
INSTRUCTION OF RAILWAY SITE ENGINEER(S). ALL THE
MATERIALS (i.e SAND, CEMENT, STONE CHIP ETC) &
MANPOWER TO BE SUPPLIED & PROVIDED BY THE
CONTRACTOR EXCEPT MS GRILL FENCE . As per 'Typical
fencing for earthing S&T installation' Annexure-III (c) of
document no. RDSO-Sig0SPD(PROJ)/1/2020 ver 0.0 dtd
01/01/25. Note: Per foundation of fence would be of
250mm X 250mm with 300mm minimum depth. "
136 136 "Supply of 50mm x 6mm GI tape for interconnecting Metre 150.00 462.71 69406.50
earth electrodes.. Inspection: Consignee "
137 137 "Installation of GI Tape (50 X 6 mm) for connecting Main Numbers 35.00 80.00 2800.00
earth pit to other earth pit in case of loop earth. Note:
'No' in the unit column indicates 'per pair of earth pit'.
The GI tape shall be buried at Depth not less than 500
mm below the ground level. "
138 138 "Construction of Concrete Path Way (500 mm Width) Metre 150.00 2165.00 324750.00
from One Earth pit to the consecutive Earth Pit. &
Painting of Earth Pit As well as concrete path way. This
includes supply of Bricks, Cement, Sand, Stone chip &
Paint of good quality. "
139 139 "Segregation of Clean & Dirty wire ( Earth wire, wire Job 40.00 3000.00 120000.00
from unprotected sources,VHF antenna cable etc.) in SM
Room and OFC Room. This includes supply of PVC pipe &
PVC Trough of different sizes & fixing of it along with
laying of dirty cable through PVC pipe/Trough. It also
includes proper writing of "" DIRTY CABLE"" & "" CLEAN
CABLE"" on the cable tray or PVC Pipe. Note- Job. in unit
column indicates per Station."
140 140 Supply of 6 feet Heavy Duty Foldable Aluminium Ladder Numbers 10.00 4543.31 45433.10
(2 wayStepladder) with broad steps on main side with PF
at the top (PFSIZE:16"X12"). Make: Kalco/Werner or
superior. Inspection: Consignee.
141 141 "Supply of Aluminium Single Pole Platform step ladder, Numbers 1.00 14830.50 14830.50
Capacity 150 kilogram. Note: The ladder should have
Portable and Compact Telescopic Ladder with 14-Steps.
Inspection: Consignee."
142 142 "Supply of Telephone instrument single push button, Numbers 100.00 761.86 76186.00
Caller Id Landline Set. Make: Beetel C51 or superior
Inspection: Consignee"
143 143 "Supply of Telephone instrument single push button, Numbers 105.00 455.85 47864.25
without Caller Id Landline Set. Make: Beetel C11 or
superior Inspection: Consignee"
144 144 "Supply of open standard SIP phone. Make: Grandstream Numbers 10.00 4465.56 44655.60
GXP1610/Alcatel or superior. Inspection: Consignee"
145 145 "Supply of Telephone Rosette Box. Inspection: Numbers 205.00 32.97 6758.85
146 146 "Supply of Wireless Phone FCT to support LTE, 5 G Numbers 25.00 5180.11 129502.75
network , CLI function,LCD Display with blacklit, call Log
(missed/dialled/received), Battery Standby Time 50 Hrs,
Battery TalkTime 3 Hrs, with Alarm Clock withsnooz,
calculator, 2-way speakerphone with volume
(adjustable),low battery warning. NOTE- CUG SIM will be
Provided by Railway Make:Beetel or superior. Inspection:
147 147 "Supply of Telephone Line Cord (RJ11). Inspection: Numbers 100.00 41.52 4152.00
148 148 "Supply of Telephone Coil Cord (RJ11) Inspection: Numbers 100.00 56.77 5677.00
SEALDAH DIVISION-S AND T/EASTERN RLY
149 149 Supply & Installation of Automatic change over device Numbers 38.00 63837.00 2425806.00
for DAC / UFSBI/BPAC to Optical fibre, STM(E1) ,
standard 19"" rack mountable device consisting of two
E1 port supporting 120 Ohms interface; dual optical
ports with (1+1) hot stand by with SFP Module loaded 20
Kms driving distance and four V.21 /V.23 (E&M) 2W/4W
interfaces with auto change over mechanism to Four
Quad ports 2W/4W ; each port configurable as 2W or 4W
no restriction in configuration ; unit to support Potential
free contacts four numbers can be linked with data
logger / RTU for E1 Status , Quad Status & Power Supply
status ; Unit support front panel ressetable audiable
buzzer in case of main link fails (optical or E1) ; Unit to
support power OFF fail safe mechanism when the unit is
switched OFF the inputs is bypassed to the Quad cable
automatcially.Note-Prior approval is required by
engineers representative before supply of material .
Make/Brand:CYGNUS 845-4P/MRO-TEK-MAPLE-
4C(O)/Team engineer or superior Inspection: RITES.
150 150 "Supply, installation, testing and commissioning of Class Numbers 22.00 12500.00 275000.00
""B"" & ""C"" surge protection device all enclosed in
transparent box complete with internal wiring and LED
lamp to indicate status of SPD. The Class C SPD shall
have remote indication contact pluggability and visual
indication. Specification mentioned as per guideline of
RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO
Drg. No. SDO / RDSO/ E&B/001 or Latest. and RDSO Doc.
No. STS/E/TAN/3006 Version 3.1 or latest. Make-
ABB/Allied Power Solutions/OBO Bettermann OR superior
Inspection: Consignee "
151 151 "Supply of Layer-2 Manageable 24 Port POE switch Numbers 15.00 32407.25 486108.75
having 24 nos. 10/100/1000 Ethernet port with POE+
support and 4x1GE SFP optical Port with Loaded optical
module (4 nos.) with all accessories as per RDSO spec
RDSO/SPN/TC/83/2020 Rev 2.1 or latest. Make:
Cisco/Juniper/D-Link//HP/TP-Link or superior Inspection:
152 152 "Supply of Layer 2 fully Managed switch (Minimum 8+2 Numbers 18.00 20837.74 375079.32
ports manageable with 2 nos. Gigabit SFP port with
loaded optical module (2 Nos.) and 8 Nos. 10/100/1000
Mbps Ethernet port, POE+ support with all accessories
as per RDSO spec RDSO/SPN/TC/83/2020 Rev 2.1 or
l a t e s t Make D-link/Digisol/Cisco/Juniper or superior.
Inspection: Consignee"
153 153 "Supply, Installation and Commissioning of 16 port Numbers 1.00 245000.00 245000.00
router having 16 WAN x 02 Mbps (E1 G.703 interface) RJ
45 ports & Min. 04 gigabit ethernet LAN ports as Per
RDSO Spec RDSO/SPN/TC/84/2008 Rev.0 or Latest with
all required accessories. Note: Prior approval is required
by railway engineers representative before supply of
material. Make: CISCO/Juniper/HP or superior. Inspection:
154 154 "Supply, Installation and Commissioning of 8 port Router Numbers 1.00 147591.00 147591.00
with 02 LAN/WAN 10/100/1000 GE with SFP Combo Ports
with loaded SFP module & ( 08X02 mbps E1 G.703
interface RJ 45 ports as Per RDSO Spec
RDSO/SPN/TC/84/2008 Rev.0 or Latest With all required
Accessories. Note: Prior approval is required by Rly
engineers representative before supply of material.
Make Make -CISCO/Juniper/HP or superior. Inspection:
155 155 "Supply of 4 Port Router having 04 WAN x 02 Mbps (E1 Numbers 25.00 95200.00 2380000.00
G.703 interface) RJ 45 ports & Min. 02 gigabit ethernet
LAN ports as Per RDSO Spec RDSO/SPN/TC/84/2008
Rev.0 or Latest With all required accessories. Note: Prior
approval is required by Rly engineers representative
before supply of material. Make:CISCO/Juniper/HP or
superior Inspection: RITES "
156 156 "Supply of Gigabit Ethernet Media Converter Single- Pair 20.00 5197.00 103940.00
Mode as per RDSO/ SPN/TC/103/2013 ver.2 or latest.
Make:Digisol/TP Link or superior. Inspection: Consignee"
RDSO/SPN/TC/82/2020 Rev 2.0 or latest with latest
ammendments. Make: Nomous/Team engineer or
superior. Inspection: Consignee.
SEALDAH DIVISION-S AND T/EASTERN RLY
RDSO/SPN/TC/80/2020 Rev 2.0 or latest with latest
ammendments. MAKE- Team engineer/Nomus or
superior Inspection: Consignee."
159 159 "Supply of 4E1 to 4 Ethernet Converter. Make: CubeTel Numbers 15.00 16559.00 248385.00
or superior Inspection: Consignee."
160 160 "Supply of CAT-6 UTP RJ-45 patch cord (5mtr long) Numbers 50.00 217.28 10864.00
twisted stranded cable terminated with RJ45 modular
plugs at both the ends. TIA/EIA-568-C.2 standard or
latest, Insulation Material : High Density Polyethylene,
Outer Jacket: FR-PVC, Conductor diameter: 23 to 26
AWG, Conductor Metal : Bare Copper. Make D-
Link/Digisol or superior Inspection: Consignee. "
161 161 "Supply of CAT-6 UTP RJ-45 patch cord (3 mtr long) Numbers 54.00 197.18 10647.72
twisted stranded cable terminated with RJ45 modular
plugs at both the ends. TIA/EIA-568-C.2 standard or
latest, Insulation Material : High Density Polyethylene,
Outer Jacket: FR-PVC, Conductor diameter: 23 to 26
AWG, Conductor Metal : Bare Copper, Make D-
Link/Digisol or superior Inspection: Consignee. "
162 162 "Supply ofCAT-6 UTP RJ-45 patch cord(1M length) Numbers 4.00 161.97 647.88
twisted stranded cable terminated with RJ45 modular
plugs at both the ends. TIA/EIA-568-C.2 standard or
latest , Insulation Material : High Density Polyethylene,
Outer Jacket: FR-PVC, Conductor diameter: 23 to 26
AWG, Conductor Metal : Bare Copper, Make D-
Link/Digisol or superior Inspection: Consignee."
163 163 "Supply of passthrough RJ-45 Connectors suitable for Numbers 1050.00 6.66 6993.00
STP/UTP cables, confirming to IS 1293:2019 or latest.
Make:-D Link/Digisol or superior Inspection: Consignee."
164 164 Supply of frame, surface box and white cover plates for Numbers 30.00 484.75 14542.50
Two modules. This also includes supply of RJ-11
Telephone sockets with level holder Jack type, RJ-45 LAN
sockets Jack Type and blanking plates for one modules.
Make: D-Link/Legrand or superior. Inspection: Consignee
165 165 Fixing of frame, surface box and white cover plates for Numbers 30.00 121.19 3635.70
Two modules. This also includes fixing of RJ-11
Telephone sockets with level holder Jack type, RJ-45 LAN
sockets Jack Type and blanking plates for one modules.
166 166 "Supply of 2.0 MP IR IP Network Dome Camera with all Numbers 4.00 3789.83 15159.32
accesssories, Image Sensor: 1/2.7"" Progressive Scan
CMOS, Lens type: 2.8mm, 4 mm, 6 mm, resolution: 1920
x 1080,Interface: 1 RJ45 10M/100M self-adaptive
Ethernet port. Power 12 VDC ± 25%, 0.4 A, max. 5 W,
Ø5.5 mm coaxial power plug PoE: 802.3af, Class 3, 36 V
to 57 V, 0.2 A to 0.15 A Make: Hikvision/CP PLUS or
superior Inspection: Consignee."
167 167 "Supply of 2 MP EXIR VF IP Bullet Network Camera with Numbers 24.00 7105.93 170542.32
all accesssories, resolution: 1920 x 1080, Lens
Type:Varifocal Lens, motorized lens, 2.8 to 12 mm,
ImageSensor: 1/2.7"" Progressive Scan CMOS, Power
supply:12 VDC ± 25%, 0.9 A, max. 11 W, Ø5.5 mm
coaxial power plug, PoE: (802.3af, Class 3, 36 V to 57
V),0.23 A to 0.36 A. Make: Hikvision/CP Plus or superior
Inspection: Consignee. "
168 168 "Supply of 23.8 Inch Full HD Led Backlit IPS Panel Numbers 15.00 11779.66 176694.90
Monitor. Make-LG/Samsung or superior. Inspection:
Make:Honeywell/MX or superior Inspection:Consignee.
Make:Honeywell/MX or superior Inspection:Consignee.
171 171 "Supply of 4+2 POE switch (Minimum 4+2 ports Numbers 12.00 4940.00 59280.00
manageable with 2 Uplink Port Switch for CCTV Camera
and Networking and 4 fast ethernet port. Make D-
link/Digisol or superior. Inspection: Consignee."
SEALDAH DIVISION-S AND T/EASTERN RLY
172 172 Supply of 8 Channels (NVR) network video recorder Numbers 12.00 9966.10 119593.20
having IP Video Input:8, HDMI Output: 4K (3840 x
Format:H.265/H.265+H.264/H.264+, Recording
Resolution: 12 MP/8 MP/6 MP/5 MP/4
MP/3MP/1080p/UXGA/720p/VGA/4CIF/DCIF/2CIF/CIF/QCIF,
Network Interface:1 RJ-45,10/100/1000 Mbps self-
adaptive Ethernet interface, RJ-45 10/100 Mbps self-
adaptive Ethernet interface, 2 SATA interfaces, Up to 10
TB capacity for each HDD, USB: Front panel: 1 x USB 2.0;
Rear panel: 1 x USB 2.0,Third-party network cameras
supported. Make: Hikvision/CP PLUS or superior.
Inspection: Consignee
173 173 "Supply of 16 Channels 4K Network Video Recorder Numbers 4.00 18950.00 75800.00
(NVR) with Support 2 SATA HDDs up to 20TB, 2 USB
ports(2.0), HDMI / VGA simultaneous video output,H.265,
H.264+, H.264, JPEG format, Video output: Video Output
720.Third-party network cameras supported. Make: CP
Plus-UNR-4K2162-V3 /Hikvision or superior Inspection:
174 174 Supply of 4TB Windows Surveillance Hard Numbers 12.00 7575.28 90903.36
Disk,compatible to all latest OS, Form Factor:
3.5,Interface: SATA 6 Gb/s, Cache (MB): 64, Water &
Shock Resistant Make: Toshiba/Seagate or superior.
Inspection: Consignee.
175 175 "Supply of Wireless Wi-Fi Gigabit Router with 4G/5G SIM Numbers 12.00 5366.40 64396.80
Card support. Make:D-Linl/TP Link/CP PLUS-CP-XR-DE21-
S-V2 or superior Inspection: Consignee. "
176 176 "Supply and Installation of 1KVA Online UPS with min. 30 Numbers 8.00 21508.92 172071.36
minute backup full load condition along in with 03 Nos.
12v/26Ah external battery (Quanta/Exide OR superior)
with terminal, battery rack & accessories set. Make:
Microtek/Numeric/Emerson (Vertiv)/ APC or superior
Inspection: Consignee. "
177 177 "Supply of Line interactive 600VA UPS, battery:12V/7Ah Numbers 20.00 3462.18 69243.60
SMF-VRLA confirming to JISC-8702 Pt 1,2 &3, IP-21
protection, ABS Enclosure, Protection against short
circuit, over voltage and over load, Input Voltage:
230V/AC, Surge Protected 6A, 2/3 Pin Output, cable
length: 1.22 m, Output Power Capacity:360Watts/ 600
VA Make: APC/Mircotek/Numeric or superior Inspection:
178 178 "Supply of Cable Route Locator/Tracer set suitable for Numbers 1.00 348066.10 348066.10
detecting underground armored OFC, Telecom, Power &
Signalling Cables with LCD graphics, Display
active/passive modes. {It must have a rechargeable
battery cum charging facility for both transmitter &
receiver along with other accessiories} Make & Model :
Radiodetection RD-8200 G/ Stanley STLOC10 or
superior. Item to be supplied after successful
demonstration and Approval of Railway. Inspection:
179 179 "Supply of optical power meter with Visual Fault Locator, Numbers 11.00 13994.48 153939.28
as per TEC spec. GR/OPM-01/03 Feb 2005 or latest. with
compatible adapter, Charging cable & all required
accessories. Note-Item to be supplied after successful
demonstration and Approval of Railway. Inspection:
180 180 Supply of digital Multimeter. Make:RISHABH 410/Fluke Numbers 10.00 2940.19 29401.90
101 or superior. Inspection:Consignee.
181 181 "Supply of Digital cable insulation tester for Numbers 17.00 7366.10 125223.70
measurement of Cable insulation resistance with auto
range 0-500V DC. Item to be supplied after successful
demonstration and approval of railway. Make: Rishabh
INSU-20/Metravi/motwani or superior.
Inspection:Consignee."
SEALDAH DIVISION-S AND T/EASTERN RLY
182 182 Supply of Digital Cable network tester (LAN Tester) to Numbers 12.00 510.40 6124.80
Check RJ11, RJ45 and BNC connectors, Full LED
indication lights on both main and remote unit, to Verify
continuity, opens, shorted or cross wire paired, Indicator
LED Lights, Power 9V Alkaline Battery, Electricity : 25mA
, make: Dlink or superior. Inspection: Consignee
183 183 "Supply of true RMS Digital Multimeter. Make- Rishabh Numbers 5.00 25307.63 126538.15
6016/Fluke or Superior. Item to be supplied after
successful demonstration and Approval of Railway.
Inspection : Consignee "
184 184 "Supply of Passthrough Crimping tool, Modular Plugs Numbers 22.00 734.93 16168.46
8P8C RJ-45, 6P6C RJ-12 and 4P4C RJ-11, 7.5 inch steel
construction body, All-steel handles (with padding),
Suitable for 22-26 AWG wires, Built-in cable stripper with
stop to ensure correct strip length continuity tester.
Inspection: Consignee "
185 185 Supply of Digital Cross Talk Meter measuring set as per Numbers 4.00 45000.00 180000.00
SPN IRS TC: 45/88 or latest with latest amdt. Make: Anu
Vidyut or superior Inspection: Consignee
186 186 Supply of Transmission measuring set (TMS kit) Numbers 4.00 22000.00 88000.00
complete with tone generator and Db meter with
Complete set with all connection lead & Accessories as
RDSO specification IRS:TC-43/87 or latest with latest
ammendments. Make: Anuvidhyut/Aplab or superior.
Inspection: Consignee
187 187 Supply of Digital Earth Resistance Tester for Numbers 2.00 7424.58 14849.16
measurement of earth resistance with Range -0.5 Ohms
to 500 Ohms. Rishabh/WACO or Superior. Item to be
supplied with accessories after successful demonstration
and Approval of Railway. Inspection: Consignee
188 188 Supply of 25W VHF power meter suitable for testing and Numbers 4.00 20000.00 80000.00
measurement in Frequency range typically 100-300
MHz. measuring Forward Power, Reverse Power. Note-
Item to be supplied after successful demonstration and
Approval of Railway Make-NISSEI RS-502/Surecom SW-
102 or Complete set with all connection lead &
Accessories. Inspection: Consignee
189 189 "Supply of Soldering Iron 65W/220V, 65 watts pencil bit Numbers 27.00 207.31 5597.37
Soldering Iron Handel Material: Wooden/FRP, 1.5Mtr
Long Wire, Capacity 230V-240V
Make:Soldron/Toni/Shakti or superior. Inspection:
190 190 "Supply of Suction and blower vaccum cleaner 700 Watt. Numbers 5.00 3987.00 19935.00
Filter Type: HEPA Filter, Capacity: 0.8 litres or more,
Noise Level: 80 dB or better along with all accessories
such as 2 in 1 small brush, cervice nozzle, hose pipe,
extension tubes, blower nozzle, floor cum carpet brush
with power cord . Make: Eureka Forbes/Inalsa or superior
Inspection: Consignee "
191 191 "Supply of Electric Drill machine 600 Watt with Technical Numbers 8.00 3639.83 29118.64
Specifications: Speed upto 3000 RPM , Rated Torque of
Min 1.4 Nm, Impact rate upto 48000 BPM, along with 01
Nos of 4 mm, 5 mm, 6 mm, 8 mm and 10 mm drill bit.
Make:Bosch GSB 600/Stanley or superior. Inspection:
192 192 Supply of Hand held rechargeable LED Torch 5W with Numbers 25.00 624.71 15617.75
upto 10 hr back up with 3.7V 3000mAh Lithium-Ion Re-
Chargeable Battery. Make: Havells/Nippo or superior
Inspection: Consignee.
193 193 "Supply of All in one PC 13th Generation Intel Core™ i3 Numbers 2.00 52960.00 105920.00
processor or better, Windows 11 Home or latest, 60.5
cm (23.8) diagonal FHD display ,8 GB DDR4 RAM, 512
GB SSD Solid State Drive, Wireless Keyboard and Mouse
, True Vision 1080p FHD IR tilt camera and operating
system with Pre-Installed MS Office Home, 02Nos 128GB
Pen drive. Make:HP/DELL/ASUS or superior Inspection:
SEALDAH DIVISION-S AND T/EASTERN RLY
194 194 "During the block working period of any department or Man- 75.00 4859.00 364425.00
dismantaling / refixing / shifting and other allied work of Days
Telecom department as-(i) Unearthing Defective Cable &
OFC Joints.(ii) Jointing/Splicing of Cables/OFC for
temporary or permanent restoration of cables/OFCs at
any time wherever instructed. (iii) Searching of
bad/defective cables/OFCs joints and Jointing/Splicing of
Cables/OFC for temporary or permanent restoration of
cables/OFCs (iv) Small Trenching Work for replacing
Defective Cable/OFC. (v) Cleaning of OFC Hut/SM
Panel/Exchange/DATACOM equpments/TIBs, CIBs/ and
Replacement of Speakers , LS cables. (vi) Carrying
Heavy Telecom Materials such as Quad Cable, Charger
from one place to another. (vii) Carrying & Depositing
Heavy Scrap materials from different stations to
Sectional Store And Other Miscllanious Works To Be
Executed. This Job Includes Cost Of Releasing Of
Telecom Equipments, Gears & Devices And
Reconnection Of The Same After the Work. The work
may be executed at any time of day or night, as per the
instructions of the Railway Site Engineer(s).. The team
should have sufficient equipment like OTDR, splicing
machine, power meter etc. Vehicle arrangements for
transportation shall also be made by the firm.. 1.Cable
Jointer Cum Wire Man =1Nos (2) Ofc Splicer =1No
(3).khalasis/ Helpers=3Nos shall be provided per
day/Night, either individually or as a group or as
specified by the Railway railway & Payment shall be
made based on the Basic Rate per Day, as applicable to
the category of manpower deployed (Unskilled/Semi-
skilled/Highly Skilled) and as specified in Annexure-I.
Note: Mandays in unit column indicates Per Day/Per
Night and all required material during the work provided
by the Railway."
195 195 "Supply of All in one inkjet printer (A4 size paper) with Numbers 5.00 8852.81 44264.05
FAX,scan, copy & print function. Make: Canon PIXMA / HP
Deskjet Ink Advantage 4178 / Epson or superior.
Inspection: Consignee."
196 196 "Supply of Maintenance console Intel Core i5 11500 8 GB Numbers 5.00 45508.47 227542.35
RAM/ 1000 GB HDD/SSD/ Windows 11 home or latest
with Pre-Installed MS Office Home, HD 720p Camera &
Keyboard & wireless Mouse, 1Nos laptop bag, 2Nos
64GB Pen drive. Make:HP/DELL/ASUS or superior.
Inspection: Consignee "
197 197 Dismantaling & Release of all old cable (data/LS & power Metre 2000.00 5.39 10780.00
cable both) as per instruction of site engineer &
transporting of the same to store.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .