| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.9 L+₹57,325 (1.72%)Rejected-Finance SHYAM BHAWAN OPP BANK OF INDIA CHOPASNI ROAD JODHPUR 342003 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹38.5 L+₹5.1 L (15.4%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹44.2 L+₹10.9 L (32.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | - | Rejected-Technical Rejected due to adverse remark against the firm in WLR |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Nov 2022, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION WORKS AT ZONE-I UNDER JURISDICTION OF GE (A) JAISALMER
2022_MES_550197_2
8225/22-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹80,000
Yes
27 Feb 2023
8 Oct 2022
3 Nov 2022
8 Oct 2022
1 Nov 2022
15 Oct 2022
Amount
Note :- The quoted rates shall deemed to be included for the following : (a) As the above work is required to be carried out for rectifying day to day E/M nature compliants, the following term and conditions shall be applied:- (b) Hence the contractor shall have to employee adequote manpower not less than 4 elects & 4 helpers to attend and rectify all the complaints/defects received in a day on same day. (c) A credit rep of contractor shall report daily at service centre to concern JE E/M or Engr -in- Charge and receive job card/complaint slip for No light complain /repair/replace the items on same day failing which the panalty shall be imposed and recovered as under :- (i) Non reporting of trademen : 300/- per elect /day Helper 200/- per helper per day (ii) Non attending the complaints to with in 48 hrs 30/- per complaints per day shall be recovered. (d) The contractor shall depute adequate trademan/ helper to repair/ replacement of u/s parts and attending the day to day complaints received from user on daily basis but not less than 4 Electrician and 4 helper per day.Providing of safety equipments to the electrician/labour will be responsibility of the contractor . He shall also deposit printed complain slip book in prescribed format as specified by Engg-in-charge for entire duration of contract at the time of sample approval it self.
Taking down of old unsv armoured cable of any type any size from surface/ casing capping / surface conduit etc as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down the existing unserviceable sheet metal neutral enclosre as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down of old unsv tubelight fitting /bulkhead/ garden light/ gate light/flame proof light of any descriptionlight fitting any type any watt complete all as specified and directed by Engineer-in-charge.
S&F in repair, Switch modular 6 Amps single pole, one way complete complete all as specified and directed by Engineer-in-charge.
S&F in repair, modular Socket outlet, multi purpose, 6 Amps 3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S&F in repair, modular Bell push 6 Amps 1 module complete all as specified and directed by Engineer-in-charge.
S&F in repair, modular Socket 16 Amps, 3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S&F in repair, modular Switch 16 Amps one way 1 module complete all as specified and directed by Engineer-in-charge.
S&F in repair, Switch modular 6 Amps two way, 1 module complete all as specified and directed by Engineer-in-charge.
S&F in repair, switch piano flush type single pole, one way 5 amps, 230 Volts complete all as specified and directed by Engineer-in-charge.
S&F in repair, switch piano flush type single pole, two way 5 amps, 230 Volts complete all as specified and directed by Engineer-in-charge.
S&F in repair, socket outlet flush type 5 Amps, 3 pin, 230 Volts as per IS complete all as specified and directed by Engineer-in-charge.
S&F in repair, switch socket combination flush type 2 in 1, 5 Amps, 230 Volts complete all as specified and directed by Engineer-in-charge.
S&F in repair, switch piano flush single pole one way 15 Amp 230 volt complete all as specified and directed by Engineer-in-charge.
S&F in repair, socket outlet flush type multipurpose 2 in 1, 5 pin 5 and 15 Amp, 230 volts complete all as specified and directed by Engineer-in-charge.
S&F in repair, switch socket combination flush type multipurpose 2 in 1, 5 pin, 5 and 15 Amp, 230 volts complete all as specified and directed by Engineer-in-charge.
S&F in repair, bell push single pole, 5 amps, 230 Volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F in repair, white colour finished mounting modular surface box of suitable size for following sizes:-
(a) One module
(b) Two module
(c) 3 modules
(d) 4 modules
(e) 6 modules
(f) 8 modules
(g) 12 modules
S&F in repair, modular white cover plate with frame inner and outer plates for following sizes:-
(a) 1 module
(b) 2 modules
(c) 3 modules
(d) 4 modules
(e) 6 modules
(f) 8 modules
(g) 12 modules
S&F in repair, Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engg-in-charge.
S&F in repair, Fan regulator, step type, flush type, 230 volts 50Hz single phase, piano type, complete all as specified and directed by Engg-in-charge.
S&F in repair, modular fan regulator 5 step type, 2 module complete all as specified and directed by Engg-in-charge.
S&F PVC insulation Tape roll 20mm width and 8 metre in length for electrical wire colour code red, yellow, blue & black joints complete all as specified and directed by Engg-in-charge.
S&F in repair, Bell, AC, 230 Volts, single pole complete all as specified and directed by Engineer-in-charge.
S&F in repair, buzzer, Ding Dong, AC, 230 Volts, single pole complete all as specified and directed by Engineer-in-charge.
S&F in repair, ceiling rose, 3 terminal, AC, 230 Volts PVC/polycarbonate, isolated body,single pole complete all as specified and directed by Engineer-in-charge.
S&F in repair, plastic laminated bakelite sheet cover of hylem 2.8 mm thick including cutting holes for switches, sockets etc as pre requirement including fixing with brass machine screws and washer complete of following sizes:-
(a) 10" x 12" size
(b) 8" x 10" size
(c) 8" x 6" size
(d) 7" x 4" size
(e) 4" x 4" size
S&F in repair, PVC rectangular block gang box for mounting switches, sockets, fan regulator etc including cutting holes for switches, sockets etc as pre requirement including fixing with brass machine screws complete of following sizes:-
(a) 10" x 8" size
(b) 8" x 6" size
(c) 7" x 4" size
(d) 4" x 4" size
S & F MCCB 415 V, 16 KA, 4 pole suitable for fixing on DB of capacity 63 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note : ICS =100% ICU
S & F MCCB 415 V, 16 KA, 4 pole suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note : ICS =100% ICU
S & F MCCB 415 V, 16 KA, 4 pole suitable for fixing on DB of capacity 125 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note : ICS =100% ICU
S&F MCB's TPN 63-100 Amps, 415 Volts,10 kA 'C' curve complete all as specified and directed by Engineer-in-charge. Note : ICS =100% ICU
S&F in repair, twisted twin core flexible copper cable of size 24/0.20 complete all as specified and directed by Engineer-in-charge.
S&F in repair, Three core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm complete all as specified and directed by Engineer-in-charge.
S&F in repair, Three core cable PVC insulated and unsheathed multistranded copper conductor of size 4.0 Sqmm complete all as specified and directed by Engineer-in-charge.
S&F in repair, Three core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm complete all as specified and directed by Engineer-in-charge.
S&F Sheet metal and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10%, Necessary mounting arrangements. The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per Crompton CAT PART NO Shelter . CIS -305-40-57-SL-DP-NWH or equivalent in Appx 'B' list of makes.
S&F LED tube light fitting 10 Watt, 2 Feet or 591 MM in length, IP 20 Protection, wall mounted type, Slim LED Batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V , 50Hz AC Supply and Operating tempraeture 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
S&F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S&F for LED down light recess mounted/Surface mounted/POP mounted or as per site requirement, square/Round type worm white / Neutral white or 3000 K to 6500 K as per user requirement 15 watts with efficiency of 100 lumens per watt, in worm white/ neutral white as per site requirement sleek design aluminium housing polycarbonate diffuser white finish operating voltage from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S & F recess mounted/Surface mounted/POP mounted or as per site requirement LED down light 5 Watt round/Square in shape worm white / Neutral white or 3000 K to 6500 K as per user requirement Ideal for wardobes, furniture lighting, display & interior decoration complete all as specified and directed by Engineer-in-charge.
S&F bldg security light fittings Wall mounted LED light 35 Watt including bracket made out of GI pipe (medium grade) 40mm, 1.20 metre long made to shape and fixed outside of the building by means of 2 No FI 40x6 mm clamps with suitable size of nuts, bolts, washers and connecting with three core copper flexible cable of size 1.50 Sq mm complete all as specified and directed by Engineer-in-charge.
Supply, laying, fixing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 Sqmm 2 Core nominal cross section in service connections complete all as specified and directed by Engineer-in-charge.
S & F Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and suitable of including warm LED bulb 15 watts complete all as specified and directed by Engineer-in-charge.
M/L for repair/refixing of loosely hanged PV/steel conduit, PVC casing & caping of any type, size by means of shadles, clamps screwes to existing wall/ceiling and making good in all respect incl wiring inside complete all as specified and directed by Engineer-in-charge.
S&F in repair, PVC conduit pipe of 20mm dia including tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-charge.
S & F in repair of LED warm white Bulb 9 Watt of Base E27 complete all as specified and directed by Engineer-in-charge.
S & F for recess mounted/Surface mounted/POP mounted 2' x 2' square LED panel 36 watts, worm white / Neutral white or 3000 K to 6500 K of size 596 x 596 x 9 mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and directed by Engineer-in-charge.
S& F wall decorative wall light fixture made out of metal body, having B-22 threaded holder suitable for 5 to 9 watt led lamp complete all as specified and directed by Engineer-in-charge.
S&F Track light with the high power LED 15 watt cylindro various luminous intensity level from 1500 to 3500 lumen ,which is perfect alternate to conventional HID lamps .Size of Track light Dia 70 mm ,length 180 mm, Height 212 mm . Make : Havells Cat Part No :CYLINDROTS15 WLED830S3WIRE38WHT or equivalent in Appx 'B' list of makes.
S&F in repair of flame proof rotary type switch with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable in flexible metalic conduit with suitable size complete all as specified and directed by Engineer-in-charge.
S&F in repair, PVC casing, capping of 25mm width ISI marked with all accessories complete all as specified and directed by Engineer-in-charge.
Fixing only MCB Single pole capacity of (6A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB SP (6 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing only MCB Single pole and Neutral capacity of (6A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB SPN (6 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing only MCB Three pole (TP) capacity (25 A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB TP (25 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing only MCB Three pole & Neutral (TPN/FP ) capacity of (25 A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB TPN (25 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing of LED tube light / LED Light fitting /Surface mounted /ceiling mounted/Bulk headlight / building security light fitting of any size or any type complete all as specified and directed by Engineer-in-charge. NOTE :- LED tube light /LED Light fitting of any description shall be issued under Sch 'B' free for fixing only.
S&F fan Capacitor 2.5 MFD, 240 V from Ceiling/Exhaust fan including taking down fan Capacitor complete all as specified and directed by Engineer-in-charge.
Shri Maruti Trading Co.
SHRI HARI CONSTRUCTION
M/S SHRI HARI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .