Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹42,850
Closing Date
12 Aug 2025, 11:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
AEE1
Tender for increasing vertical clearance of existing 66kV ITI-Hebbala-1 & 2 (Hebbala - L.R.Bande & Hebbala - Banaswadi tapped to pottery road) double circuit line between tower No. 06 & 07 in HMT Layout, R.T Nagar by providing 02 Nos of 66kV DC plus 6 NBT KPTCL design towers in TLM Sub division, Hoody in the jurisdiction of BMAZ South Circle
KPTCL/2024-25/EL/WORK_INDENT892/CALL-10
KPTCL/2024-25/EL/WORK_INDENT892/CALL-10
Open
Electrical
Two Tender Document System(Two Cover)
KPTCL SEE Transmission And Mantainance Circle BMAZ South Bengaluru
24 documents required · 23 mandatory · 1 optional
Should have carried out erection of all connected equipments of (01)One Transformer Bay/errection of One Transmission line tower/One Terminal Bay of 110/66kV class or above voltage class on Total Turnkey or Partial Turnkey basis, which shall be in satisfactory service for a period of One year prior to date of submission of the Bid. OR Should have carried out erection of all connected equipments of 02(Two) Transformer Bays/two Transmission line towers/ two Terminal Bays of 110/66KV class or above voltage class on Labour Contract or as Sub-Contract to any Turnkey Contractor which shall be in satisfactory service for a period of One year prior to date of submission of the Bid
List of existing commitments and ongoing works
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
GST Certificate
Bidders shall submit audited financial reports for last five years preceding the date of bid submission duly certified by Registered Charted Accountant. Minimum Average Annual Turnover (MAAT) of the bidder for best three years out of last five financial years
Self declaration of not blacklisting, no litigation, no deviation
Power of Attorney
Letter of undertaking
Techno commercial sheets
A certificate is required to be uploaded by both Bidder and Consortium Partners separately regarding restriction on procurement from a Bidder/Consortium Partner of a country which shares a land border with India in the format as specified in the clause No.1.5 of Annexure - XVII of the Tender document
Certificate is to be uploaded by the Bidder agreeing to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India as specified in Annexure - XVIII of the tender document
Self declaration regarding Risk & Cost
The Bidder or his consortium partner should posses valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of Bid Submission.
₹1,080
₹42,850
21 Jul 2025
21 Jul 2025
14 Aug 2025
28 Jul 2025
Tender for increasing vertical clearance of existing 66kV ITI-Hebbala-1 & 2 (Hebbala - L.R.Bande&Hebbala - Banaswadi tapped to pottery road) double circuit line between tower No. 06 & 07 in HMT Layout, R.T Nagar by providing 02 Nos of 66kV DC plus 6 NBT KPTCL design towers in TLM Sub division, Hoody in the jurisdiction of BMAZ South Circle
Fabricated Steel members for 66kV NBT KPTCL Design Tower DC type tower MS [2.710*2=5.420] MS for Stub [0.418*2=0.836] 6 Metres extension MS [1.132*2=2.264]
Supply of galvanized Bolts & Nuts (0.165+0.07=0.235*2=0.47 MT)
Supply of Number Plates
Supply of Danger Boards
Supply of Phase plate (Set of 6 No.)
Supply of Circuit plates
Grounding of tower including the cost of 40 mm dia 2.5mm thick, class C GI pipe of 3 mtrs length with 50 x 6 mm GL flats 3 mtrs long, salt charcoal, including excavation charges.
Copper earth bond 300 mm
Supply of High Performance Conductor (HPC) of Ampacity - 700 A- existing HTLS Conductor
Supply of 7/3.15 mm GI Wire for Ground conductor.
Supply of 90kN Disc Insulators. (5 discs/string therefore, 5*24=120)
Supply of Single Tension fitting with Terminal Pad
Supply of Repair sleeves suitable for HPC
Supply of Vibration dampers for HPC
Supply of Single suspension clamps for Ground Conductor
Supply of T-Clamp
Supply of PG Clamps for Ground Conductor
Check survey using their own equipment
Erection of 66kV DC+6 NBT KPTCL Design Tower
Setting of stub templates and aliging dismantling and transportation of templates from one location to another location
Sorting of Tower parts made of fabricated angle iron.
Supplying and fixing G.I. Angle iron 45 x 45 x 5 mm (1 m length) with cleats, bolt & nuts as per specification and fixing above 0.5 m length each at inner and outer surface of the tower to facilitate ...
Supplying and fixing Barbed wire as per specification.
Fixing of Number Plates
Fixing of Danger Boards
Fixing of Phase plate (Set of 6 No.)
Fixing of Circuit plates
Labour charges for Grounding of tower including the cost of 40 mm dia 2.5mm thick, class C GI pipe of 3 mtrs length with 50 x 6 mm GL flats 3 mtrs long, salt charcoal, including excavation charges.
Rivetting of tower bolt ends by heating using dry-acetylene gas and hammering to destroy threads so as to make the tower members theft - proof (600 Bolts/Tower)
Welding of bolts & nuts (400Bolts/Tower)
Re-Stringing/Releasing: (Existing HTLS equivalent to Coyote ACSR) Paving out conductor from anchor to anchor normally spaced at 5 spans with 4 tangent towers in between, including providing stays at e...
Stringing: (New HTLS/HPC Conductor equivalent to Coyote ACSR) Paving out conductor from anchor to anchor normally spaced at 5 spans with 4 tangent towers in between, including providing stays at each ...
stringing of new ground conductor 7/3.15 mm earth wire without allowing the conductor to touch the ground and without damaging the conductor.
Dismantling existing 66kV DA+0 tower no 06&07 without stub.
Excavation for line tower foundation Normal Soil- Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and su...
Excavation for line tower foundation Dry Fissured/Ordinary Rock: Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings &...
Foundation Concreting : Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates ...
Foundation Concreting : Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates ...
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tyin...
Back filling and levelling with available soil
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
TENDER DOCS HBL TO LRBANDE.zip
Tender Document • 0.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .