| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | ₹6.5 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹7.2 LRejected-AOC SBSTC GARAGE MORE DURGAPUR WEST BENGAL PIN 713201 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713201 | ₹7.2 L | L2 | Rejected-AOC L2 BIDDER |
| 3 | L3₹7.2 LRejected-Finance 2 102A SREE COLONY KOLKATA 700092 | KOLKATA | KOLKATA | WEST BENGAL | 700092 | ₹7.2 L | L3 | Rejected-Finance EMD TO BE REFUNDED |
| 4 | Not Admitted-Fee/PreQual/Technical 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical BAISHNAB PARA PURULIA | PURULIA | PURULIA | WEST BENGAL | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹6.5 L
EMD Value
₹13,086
Closing Date
27 Jan 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (ELECTRICAL))
1ST ADMINISTRATIVE BUILDING, CITY CENTRE, DURGAPUR
ELECTRICAL WORKS
2026_ADDA_987509_1
ADDA/DGP/ED/N-64/2025-26(SL-2)
Open Tender
Electrical Work/ Equipment
90 days
CITY CENTRE, DURGAPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹13,086
16 Mar 2026
15 Jan 2026
29 Jan 2026
15 Jan 2026
27 Jan 2026
15 Jan 2026
Distribution wiring in 1.1 KV single core stranded "FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. Fittings as required. 2 x 56/0.3 (4 sq.mm) + 1 x 36/0.3 (2.5 sq. mm)ECC. PWDSR Nov 2017, Pg. E14, 1aiii + 3% District Charge.
Supply at the work site of IP 66 and IK 07 flood lighting luminaire with 4 KV in built surge protection device and PDC aluminium alloy housing. Lumen output is 24K, nominal wattage is 200 W, suitable for 220-240V, 50 Hz AC supply & nominal system efficacy is 120 lm / watt. Make: Philips {BVP 283 LED 240 CW FG SY5WB 200W SPD V1(with internal SPD 4 Kv + external SPD 10 Kv )} / appvd. equivalent from Crompton / Bajaj / Wipro.
Fixing only flood light fitting with suitable tie clamps and MS plate for mounting on pole / tower or similar structure. C3, 20a + 3% District Charge.
Supply at the work site of 4C x 16 sq.mm Al. conductor, XLPE insulated, armoured, overall PVC sheathed, 1.1 KV grade power cable conforming to IS: 7098(Part-1) 1988 with latest amendments. Make: Polycab / Finolex / KEI / Havells. Analysed Rate, KEI LP 09.10.2024. Analysed rate.
Laying of one No. cable upto 35 sq.mm in underground trench460mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. Item No.1.a of Pg. F2 of PWD (Elect.) SR w.e.f. Nov.2017 + 3 % district charge.
Laying only Cable upto 50 sq.mm through existing RCC/Hume/GI Pipe/open masonry trench for single, 2, 3, 3½ & 4core. (Item No.3.a of Pg. F1 of PWD (Elect.) SR w.e.f.Nov.2017 + 3% district charge.
Laying of cable upto 3/4core x 25 sq. mm on wall / surface incl S & F MS saddles with earthing attachment in 10 SWG GI (hot dip) wire, making holes etc as necy. mending good damages and painting. F1, 2b + 3% District Charge.
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. 50 mm dia. PWDSR Nov. 2017, Pg. F6, Item 11d + District Charge @ 3%.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE / PVC armoured cables as below: 4C x 16 sq.mm. F4, 7c + 3% District Charge.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials: 4C x 16 sq.mm. F5, 8b + 3% District Charge.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Legrand 6-32A SP. D6, 7 + 3% District Charge.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall / on iron frame (S & F) after cutting the wall &mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Legrand, 4 Way, Enclosure 607715.D10, 14 + 3% District Charge.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Legrand 40 A FP. D6, 7 + 3% District Charge.
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc. incl. S & F 3 nos. DIN type HRC fuse as per rating. 63A TPN, L&T.D3, 4a + 3% District Charge.
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc. incl. powder coated painting. D5, 5 + 3% District Charge.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts.Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA medium GI pipe. G1, 2a + 3% District Charge.
Excavation of soil for installation of earth electrode and filling and ramming. For soft soil. G-1, 1a + 3% District Charge.
Excavation of soil for installation of earth electrode and filling and ramming. For morrum soil. G-1, 1b + 3% District Charge.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. G2, 4c + 3% District Charge.
Extra for treatment of soil by using salt & charcoal or coke for electrode. PWDSR Nov.2017,Pg.G-2,Item-3b + District Charges @3%
Connecting the equipment body to earth bus bar including S & F 25mm x 6mm galvanized (hot dip) MS flat on wall / floor with GI saddles as required and connection to equipment incl. drilling holes, with bolts, nuts, washers etc. PWDSR Nov. 2017, G3, 5d+ 3% District Charge.
G S T As applicable @ 18% on total work done value ( SL NO. - 1 to 21 )
Labour Welfare Cess @ 1% on total work done value including G S T ( SL NO. - 1 to 22)
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
TenderBook.pdf
Tender Documents • 1.98 MB
BOQ_2412196.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid