| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹35.4 L+₹88,865 (2.57%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹37.1 L+₹2.5 L (7.25%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹43.5 L+₹9.0 L (25.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹46.0 L+₹11.4 L (33.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
5 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/TOKEN- 72 OF 2021-2022 CLEANING OF OH RESERVOIRS, UG SUMPS AT VARIOUS INSTALLATIONS, PUMP HOUSES, SERVICE TANKS TO ACCNS AND OTHER ALLIED WORKS IN THE AREA OF AGE E/M (N) UNDER GE (N) PUNE
2022_MES_501619_2
GE (N) P/TOKEN- 72 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹88,000
Yes
24 Feb 2022
27 Jan 2022
7 Feb 2022
27 Jan 2022
5 Feb 2022
31 Jan 2022
60 days
Amount
Material and labour for cleaning of RCC underground Sump after scrapping out the scales/deposits from all inner surfaces of sump thoroughly washing with bleaching powder solution (mixed @ 0.5 Kg of bleaching powder of chlorine content 30% per 1000 liters of water), bailing out the settled materials completely away from the site within 100 metres distance, cleaning the tank with clean water and finally sterilizing the tank as mentioned in notes below and resetting the existing level readings complete including taking down and re-fixing of foot valve after necessary cleaning, repairs etc., and replacing minor parts if any required for proper functioning of foot valve, testing and writing “TANK CLEANED ON…..”(date), “DUE DATE ON…..(date) and "CAPACITY .... GALLONS" with 10 cm size white letters on black back ground by engaging skilled artist using best quality synthetic enamel paint all as specified and directed by Engr-in-Charge for the following sizes:-Note :-(i) Writng to Letters will be measured and paid separatly under relavant Item.
Under Ground sump of capacity 1,50,000.00 gallons at Ghorpadi Pump House No.1
Water storage tank of 50,000 glns capacity at 64 Pump House, Victoria Road Pump House, Ghorpadi Pump House No 2, DAD Complex Pump House, Children School Pump House, Milkha Singh Pump House, Manoj Pandey Pump House, Old KG line New Pump House, SCOM House, Ashoka marg Pump House.
water storage tank of 40,000 glns capacity at 64 Pump House and Victoria Road Pump House
water storage tank of 30,000 glns capacity at 16 Queens Garden Pump House, HQ SC Pump House, Shanti Vihar Pump House, Ashoka marg Pump House, 64 Pump House
Underground sump of 25,000 glns capacity at 64 Pump House and SCSR comminication complex Pump House.
Underground sump of 20,000 glns capacity at Victoria Pump House, CESC Pump House, Nirman Vihar Pump House, MES Key personnel Pump House, Commnd MT Pump House, SCOM Pump House and Sainik Aramgrah pump House.
Underground sump of 10,000 glns capacity at CEPZ Pump House, Ashoka Marg Swimming pool
Underground sump of 5,000 glns capacity at PCDA office Pump House, 2 Arjun Marg, Race cource, Comd House and 14 Queen Garden
Scrapping down, cleaning internal surfaces of walls, floors, roofs, drainage system etc of RCC OH reservoirs with of 10 to 20 metres hight staging, removing the accumulated sand/ silt from the chambers as described below and depositing where directed at a distance not exc 50 metres complete all as specified and as directed by the Engineer-in-Charge for the OH reservoir of capacity 60,000 gallons at Milka Singh Pump House and Old KG line Pump House :- (a) Suitably blocking the incomming and outgoing wash out pipes for avoiding mud and foreign meterials deposited in the OH reservoirs getting into pipes and chocking it prior to starting the cleaning. (b) Bail out complete water remaining in the OH reservior before cleaning the mud and other deposits. (c) Filling up the over head reseviors full and feed the affected residential/OTM consumers enough water to sustain during the resevior cleaning period. (d) Manually remove deposited mud sludge and other foreign particles and deposit the same separately away from tanks in low laying areas and levelling complete all as directed. (e) Clean the floor wall and dome of the OH reservoir by jetting water using rotary pressure jets, remove the sludge so deposited completely by rubbing the wall/ floor with brushes and repeat removal and depositing complete as directed (Approved detergent shall be used). (f) Writing of the date of cleaning of the water tank with white letters on black background. (g) Sterilization of tank by agents eco-friendly, bio-degradable and highly effective against all pathogens, or approved chemical. (h) Sterilization of tank atmosphere by industrial UV radiator leaving the tank complete sterilized (i) All the required Tools and plants, lubricants/oils and materials will be supplied by the contractor during the work. (j) Fresh air to be blown into the tank for a period before allowing a person to enter. The cleaner should wear protective clothing, including gloves, a boots, Safety Helmet and glasses. Contractor should make sure someone remains outside the tank, next to the access hatch all the time in case the cleaner has an accident. The availability of gas masks and portable ventilators would be made available by the contractor at site during cleaning ope Note :-(i) Remove the blockage from inlet/ outlet over flow pipes and ensure satisfactory distribution. (ii) Writng to Letters will be measured and paid separatly under relavant Item.
All as serial item No. 02.00 but for OH Reservoir of capacity 50,000 gallons at 64 Pump House, Victoria Road Pump House, Ghorpadi Pump House No 1, Ghorpadi Pump House No 2, DAD Complex Pump House, SCOM Pump House and Manoj Panday Pump House Milkha singh Pump House , Old KG line Pump House.
All as serial item No. 02.00 but for OH Reservoir of capacity 30,000 gallons at Victoria Road Pump House
All as serial item No. 02.00 but for OH Reservoir of capacity 25,000 gallons at 64 Pump House.
All as serial item No. 02.00 but for OH Reservoir of capacity 10,000 gallons at SCSR comunication complex Pump House.
M&L for preparation of internal plastered/ concrete surfaces of overhead reservoir of capacity upto 1.5 lakhs gallons at different locations and applying two coats nontoxic, non-corrosive water proof coating inside the tank complete all as specified and directed. Make:- Sikagard-67, Dr Fixit Pidifine 2K, Clean Tech PW or equivalent as certified by CFTRI, Mysore for potable water Note: - a) Surface preparation and application procedure shall be as per manufacturer’s guidelines and directions of Engineer-in-Charge. b) The paint used should not contain any harmful chemical content to pollute drinking water. A manufacturer certificate for the same is mandatory and contractor must produce the certificate as mentioned above before application to Engineer-in-Charge
M&L for preparation of internal plastered/ concrete surfaces of UG sump of capacity10000 upto 1.5 lakhs gallons at different locations and applying two coats nontoxic, non-corrosive water proof coating inside the tank complete all as specified and directed. Make:- Sikagard-67, Dr Fixit Pidifine 2K, Clean Tech PW or equivalent as certified by CFTRI, Mysore for potable water Note: - a) Surface preparation and application procedure shall be as per manufacturer’s guidelines and directions of Engineer-in-Charge. b) The paint used should not contain any harmful chemical content to pollute drinking water. A manufacturer certificate for the same is mandatory and contractor must produce the certificate as mentioned above before application to Engineer-in-Charge
M&L for preparation of old external plastered/ concrete surfaces of overhead reservoir/UG sump and Distempering walls with cement paint, white or tinted, as per manufacturer's specification. Two or more coats on new work
M&L for preparation of external surface Including grouting and rendering of damage surface & matching with the exiting surface of overhead water storage tank of 10 to 20 meters upto capacity 1.5 lakhs gollons by scrapping all dirt’s dust, rust from roofs and overhead tank wall etc and then apply with two coats of heat reflective paint With SRI >=122 even and smooth of white colour with colour bands all complete as directed by Engr-in-charge. Make of Paint : COOL-ROOF-AV Note: Contractor has to ensure the safety of the working personnel and the quoted rate inclusive the rate of tools and equipments needed for the job.
M&L for scraping, cleaning of walls,pillars of 10 to 20 meters staging overhead water tank at filter house and other water supply installations by scrapping all dirt’s dust, rust from roofs ,walls,pillars of overhead tank etc and then apply with two coats of insect (mosquito/bee) repelling paint even and smooth of white colour with maroon colour bands or all complete as directed by Engr-in-charge. Make of Paint : CORION -REPEL PAINTS Note: Contractor has ensure the safety of the working personnel and the quoted rate inclusive the rate of tools and equipments needed for the job.
Material and labour for preparation of old painted steel or iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of new or previously untreated steel or iron surfaces of any description over 10cm width or girth and applying one coat of red lead primer and one coat of black japan paint complete all as specified and directed.
M & L for Preparation of old plastered or unplastered wall surface for white washing
M & L for Preparation of old plastered or unplastered ceiling surface for white washing
M&L for white washing one coat for internal, external surfaces of pump houses complete all as specified and directed.
M&L for Scrubbing the old paint by means of sand paper and preparing the surface for fresh painting and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the pertaining MES and SM no. as specified for the following capacity :
Centrifugal pump set 3HP
Centrifugal pump set 5HP
Centrifugal pump set 7.5 HP
Centrifugal pump set 10 HP
Centrifugal pump set 15HP
Centrifugal pump set 20HP
Centrifugal pump set 25HP
Centrifugal pump set 30HP
Taking down of old unserviceable steel ladder of any steps any size from UG sump and overhead tanks
Supplying and fixing steel ladder IN UG sump and overhead RCC tanks with 12 numbers of steps made using 32mm medium grade GI pipe having 30 cm step to step spacing, 40 cm outer width and 3.5m to 4.0m height including applying two coats of nontoxic, non-corrosive water proof paint over a coat of primer after necessary surface preparation and grouting at site complete all as specified and directed. Make:- Sikagard-67, Dr Fixit Pidifine 2K,Clean Tech PW or equivalent as certified by CFTRI, Mysore for portable water.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
S&F framed work such as grill,channel, valve chamber cover, grating ,etc,with end of bars shouldered and/or riveted,or forged in to spikes, framed guard bars, flat iron, angle, barred iron doors, ladder, framed balusters,walk ways,railings,framework of water tanks and and similar work GDE Fe-410-0 or Fe-310-0,
Taking down old u/S MS plates any size
S & F Fe-410- W(Gde- E- 250)Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes including necessary nuts,bolts, washer etc with necessary fabrication and alterations required at site
M&L for running welding of thickness n'exc 6mm in repairs complete all as directed.
S & F in repair Aviation obstruction light on 60ft staging overhead water tank with all mounting arrangements, cementing etc having LED 36/40W capacity in yellow painted die cast alluminium alloy housing red colour polycarbonate dome and accessories. Make : Bajaj, Havells, Crompton
Taking down old unserviceable copper sub main wiring of size 2.5 sq.mm including earth continuity wire complete all as directed.
M&L Sub main wiring with 2 runs of 2.5 Sq.mm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable with one run of 1.5 sq.mm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor drawn in surface/recessed in steel conduit complete all as specified and as directed. Note:- Two runs of FR cable, one run of earth continuity conductor FR cable and one run of steel conduit shall be measured as one length/running metre.
Taking down of old unserviceable/serviceable GI/aluminium earth continuity conductor from over head RCC tanks of any size , if found serviceable will refixed if found unserviceable will be discarded all as per directed by Engineer-in-charge
M&L for GI earth continuity conductor or main earthing lead fixed of size 25 X 4 mm to wall on batten/porcelain/epoxy insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc.connected upto test terminal point etc complete including fixing with saddles and screws for fixing porcelain/epoxy insulators/conduit/pipe , all as specified and directed for the following type of conductors :- Note : - Insulators/conduit/pipe shall be measured and paid separately under appropriate items here in after
M&L for GI/ aluminium earth continuity conductor or main earthing lead of any size to be re-fixed to wall on batten/porcelain/epoxy insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc.connected upto test terminal point etc complete including fixing with saddles and screws for fixing porcelain/epoxy insulators/conduit/pipe , all as specified and directed for the following type of conductors :- Note : - Insulators/conduit/pipe shall be measured and paid separately under appropriate items here in after
M&L for plate earthing for complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of equipments etc at the other end , earth strip encased in and including 40 mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 4 mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with wire mesh , funnel and excavation and earth work, earth pit in PCC 1:2:4 type B-O using 12.5 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No -3 of SSR Pt-I. Note:- (a) Rates for Excavation and earthwork in any type of soil/strata, testing on completion, GI strip 25x4 mm dia and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. (b) On testing, after completion, if the earth resistance less than 3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained.
S&F in repair Air termination single pointed aluminium rod not less than 12mm dia and 300mm long including fixing arrangements all as specified and as directed.
S&F in repairs Post insulator epoxy LV type suitable for aluminium/ GI strip 25 x 4 mm lightening conductor fixed on wall/roof/pole including screw, and taking out existing insulators complete all as specified and as directed.
M&L for Lifting of submersible pump set of any make/ capacity from any depth but not more than 250 feet depth including disconnecting and taking down colomn pipe from coupling one by one along with submerssible cable and keeping in safe custody for lowering after developement of bore well complete all as specified and directed. Note: (i) No T& P will be issued by departement for lifting/ lowering of pump set. (iii) Cost of T&P and any other materials and transport for taking the pump set for work shop and back (if required) will be bear by the contractor and the cost of same is deemed to be included in item rate.
M&L for Cleaning and redevelopment of existing borewells and with 250 psi and 750 cfm capcity air compressor (to get maximum yeild ) continously until clear water obtained all as specified and directed by EIC. Note : Cleaning depth will be measured after the cleaning machine has gone to the lowest depth already achieved in the existing borewell
M & L for rigid pvc sheet at least 3mm thick and density 700 kg per cum screen printed with suitable designs using Glossy PVC Ink and to be fixed using necessary nut ,bolts, washers etc.
S & F in repairs Wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples with size of mesh 20 mm
S & F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Demolition and dismantling of concrete of any description and in any position not otherwise specifically provided and throwing the rubbish with in 50mtrs
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping including necessary formwork as required complete all as specified and as directed.
M&L for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) for Cement concrete in foundations, filling and mass concrete including necessary formwork as required complete all as specified and as directed.
M & L for reinforced cement concrete (nominal mix) in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves including form work as required with type B!(1:2:4) 20 mm graded aggregate
M & L for TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Make:Rashtriya Ispat Nigam Limited (RINL),Tata Iron & Steel Company (TISCO or Tata Steel),M/s Jindal Steel and Power Ltd (for TMT bars),M/s Electrosteel Steel Ltd
Demolition of old u/s Brickwork or stone/boulder masonry but built in cement mortar or cement lime mortar Note : Work may involve working on RCC tank of staging 10 tp 20 meter above ground. The quoted rate deem to be includes the same and no extra demanad for cost will be entertained at later stage.
M&L for brick masonry with fly ash bricks exc 6 meter mean radius in cement mortar 1:6 all as specified and directed. Note : Work may involve working on RCC tank of staging 10 tp 20 meter above ground. The quoted rate deem to be includes the same and no extra demanad for cost will be entertained at later stage.
Dismantling and removing cement plaster of any thickness and removing from site to a distnace exc 50 metre but not exc. 100 metre all as directed. Note : Work may involve working on RCC tank of staging 10 tp 20 meter above ground. The quoted rate deem to be includes the same and no extra demanad for cost will be entertained at later stage.
M&L for rendering with 15mm thick in cement mortar 1:4 on fair surfaces of brick or concrete surafaces finshed even and smooth surfaces without using extra cement and all as specified and directed by Engr-In-Charge.
M& L for Rough excavation in soft/loose soil not exceeding 1.5 m deep and getting out in black cotton soil of above mentioned sites.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms by using excavated soil.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at level not exc. 1.5 m above starting point.
M & L for Writing letters alphepet or figures in (Block.Roman, Italic or Indian) n exc. 30 cm length with suitable font thickness, to write in a height of upto 18 mtr including arranements of skufoldings all as specified and as directed.
M & L for Writing letters in English Small/ Capital or figures in Roman/Arthimatic (Block. Roman, Italic or Indian) n exc. 60 cm length with suitable font thickness, to write in a height of upto 18 mtr including arranements of skufoldings all as specified and as directed.
Supplying and fixing 3mm thick, plain acrylic transparent sheet on wall including necessary fixing accessories like stainless steel fasteners, bolts etc., with all alteration at site incuding cutting, reaming etc. complete all as directed.
Removal of bio-degradable bee-hives wild growths from the structure tank and member of the overhead reservoir complete including wild bees with suitable application of fuming smoke or chemical fog application and applying a coat of alergent for keeping away or return of bee-hives (All the bee-hives on the tank shall be removed and cleaned) Note : The removal of bee-hives shall be carried out with total precautions so that wild bees do not get the time and opportunity to attack the public in the locality.
Material and labour for chemical and biological testing potable water as per IS 10500 (latest revision) sample from the nearest district Laboratory or municipal corporation P.H.E. including transportation complete all as specified and directed. Note:- The rate quoted by contractor includes the following: 1. Collecting water samples in sterlised containers from the location as directed by Eng-in-Charge 2. Transporting the collected sample immediately to the lab and submitting the test report to the Eng-in-Charge.
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
visionenterprises
purva engineears and contracters
K.K.Enterprises
Sai Ram Electricals and Refrigeration Works
Dheer Engineering
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
Fine-Tech. Electricals
Chaulya Enterprises
Suchit constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .