Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.1 L+₹24,930 (2.52%)Rejected-Finance NO 45 2ND FLOOR RANGANATHA LAYOUT NEAR GURUKUL HIGH SCHOOL MAHADEVAPURA BANGALORE KARNATAKA 560048 | BENGALURU URBAN | KARNATAKA | 560048 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹10.3 L+₹44,530 (4.50%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹10.5 L+₹64,050 (6.47%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹12.0 L
EMD Value
₹23,940
Closing Date
11 Jul 2018, 6:00 pmClosed
Asst General Manager (E-E)-II
Airports Authority of India Madurai Airport.
ARMO Works of EandM Installations at Madurai Airport during 2018 19 SH Comprehensive Annual Maintenanace Contract of Unitary Air Conditioning, Water coolers, RO Plant and Water dispensers
2018_AAI_12178_2
AAI/MDU/E-E/MDU-214/NIT-05
Open Tender
Electrical Works
Works
365 days
Madurai Airport, Operational Area
Please refer Tender Documents
12 documents required · 12 mandatory
₹1,120
Yes
GM AAI
₹23,940
Yes
29 Jun 2021
3 Jul 2018
13 Jul 2018
3 Jul 2018
11 Jul 2018
3 Jul 2018
3 Jul 2018 - 10 Jul 2018
Amount
JOB CONTRACT Job contract for Operation, preventive and breakdown maintenance of various AC's , Water coolers, Water dispensers, RO Unit etc Installed at Nav-aids, OTB, Engineering offices etc as detailed in "ANNEXURE" - A" at Madurai Airport as per need basis in line with the requirements indicated in the tender document and as required.
Type & Capacity All inclusive Comprehensive Maintenance of all types, makes and capacities of air conditioning units including routine and preventive Maintenance, breakdown repairs, replacing spares, Painting etc complete as required. Ductable split type - 8.5 Ton
All inclusive Comprehensive Maintenance of all types, makes and capacities of air conditioning units including routine and preventive Maintenance, breakdown repairs, replacing spares, Painting etc complete as required. Hide away split type - 7.5 Ton
All inclusive Comprehensive Maintenance of all types, makes and capacities of air conditioning units including routine and preventive Maintenance, breakdown repairs, replacing spares, Painting etc complete as required. Non-ductable Split type with hide away fan coil units - 5 Ton
All inclusive Comprehensive Maintenance of all types, makes and capacities of air conditioning units including routine and preventive Maintenance, breakdown repairs, replacing spares, Painting etc complete as required. Cassette type split - 4 Ton
All inclusive Comprehensive Maintenance of following types of airconditioning units including routine and preventive maintenance, breakdown repairs, replacing spares, painting etc complete as required. Vertical split type - 3 Ton
All inclusive Comprehensive Maintenance of following types of airconditioning units including routine and preventive maintenance, breakdown repairs, replacing spares, painting etc complete as required. Split/ multi split type - 2 Ton
All inclusive Comprehensive Maintenance of all types, makes and capacities of air conditioning units including routine and preventive Maintenance, breakdown repairs, replacing spares, Painting etc complete as required. Split type - 1.5 Ton
All inclusive Comprehensive Maintenance of all types, makes and capacities of watercoolers including routine and preventive maintenance, breakdown repairs, replacing spares, painting etc complete as required.
Comprehensive Maintenance of 16 ltrs capacity hot & cold water dispenser with separate freezer compartment including water container of 20 ltrs capacity suitable to operation on 230V 50Hz AC supply etc., as required.
Trans installation of split airconditioners of following tonnages including dismantling, gas charging, modifying and joining of old pipelines etc., complete as required. 1.5 TR Split A/C
Trans installation of split airconditioners of following tonnages including dismantling, gas charging, modifying and joining of old pipelines etc., complete as required. 2.0 TR split A/C
Trans installation of split airconditioners of following tonnages including dismantling, gas charging, modifying and joining of old pipelines etc., complete as required. 4.0 TR cassete type split a/c's
Supply of 1/4" or 1/2" insulated copper pipe as per site requirement
Supply of 5/8" or 1/2" insulated copper pipe as per site requirement
CMC of 50 LPH R.O Purifier with Minimum of Six stage Purification fully enclosed in powder coated sheet steel enclosure mounted on wall suitable for operation on single phase. 230 V, 50 HZ AC Supply etc. I/C Interconnection with Water cooler etc. Complete as required as per the Specification.
CMC of Water Cooler of Capacity 80/40 ltrs, Self Contained Fully Stainless body, two taps, etc. Including Inbuilt RO Water Purifier 50 LPH with all accessories suitable for operation on 230V, 50HZ Single phase AC Supply etc. I/C Complete as Required as per specification enclosed.(Make: Cross Fields)
Half yearly testing of Water quality for both chemical & bacteriological examination at approved lab and furnishing the test report to AAI
Gnosi Tech Services
ARCTICENTERPRISES
GENIUS AIRCON PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .