| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹28.4 L+₹7,972.50 (0.28%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹28.5 L+₹20,122.34 (0.71%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹32.1 L+₹3.8 L (13.4%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹32.8 L+₹4.5 L (16.0%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
3 Dec 2020, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Special repair and alternate switching of LED security lights, conversion of HPSV / HPMV high mast lights into LED flood light, 2x15 KVA UPS, 03 x high mast light and certain sanctioned works under GE (Army) Suratgarh at Suratgarh Mil Stn
2020_MES_392934_1
GE (A) SOG - 56/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹82,000
Yes
11 Jan 2021
5 Nov 2020
5 Dec 2020
5 Nov 2020
3 Dec 2020
19 Nov 2020
Amount
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable service bracket any type and any size on LT / HT poles complete all as specified and as directed by Engineer-in-charge.
Taking down high mast light fitting such as SV / MV / MH light fitting 250/400 watts or 160 / 200 watts, flood light fitting and replace with new flood light of 150 / 200 / 300 watts and finding faults, tightning of loose connection, cleaning etc complete all as specified and directed by Engineer-in-Charge. Notes :- (i) The new flood lights which are required to be replaced shall be measured and paid for separately as “Supply only” under srl item No 4 to 6 of BOQ here-in-after. (ii) Detection and rectification of fault in over head / under ground line shall be done by the contractor & rate for the same is deemed to be included in this item. Nothing extra shall be paid on this accout.
Supply only LED flood light of 150 watt with high pressure die cast housing with lens with lumen output 6000K complete (including LED, drive and internally prewired) with on board 10 KV surge protection. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 /66 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 110 lumens per watt including connection with PVC insulated stranded copper conductor cable, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Crompton Cat part No LFLN-150-CDL/60-M / Wipro cat part No LF07-152-090-50-V5 / Philips cat part No BVP122 LED 150 CW HE NB FG XTFCL S4 /Syska cat part No SSK-BLS-N-150W
Supply only LED flood light of 200 watt with high pressure die cast housing with lens with lumen output 6000K complete (including LED, drive and internally prewired) with on board 10 KV surge protection. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 /66 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 110 lumens per watt including connection with PVC insulated stranded copper conductor cable, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Crompton Cat part No LFLN-200-CDL/60-M / Wipro cat part No LF20-272-060-57-G2 / Philips / Syska cat part No SSK-BLS-N-200W
Supply only LED flood light of 300 watt with high pressure die cast housing with lens with lumen output 6000K complete (including LED, drive and internally prewired) with on board 10 KV surge protection. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 /66 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 110 lumens per watt including connection with PVC insulated stranded copper conductor cable, 1100 volts grade, 4 sqmm x 3 core of ISI marked complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Crompton Cat part No LSFO-300-CDL/60-M / Wipro cat part No LF20-392-060-57-G3 / Philips / Syska Syska cat part No SSK-BLS-N-300W
S&F in replacement integral aviation obstruction light comprising of aluminium housing with polycarbonite enclosures complete all as specified and directed by Engineer-in-charge.
Supply and installaton in replacement of control panel (KIOSK) (out door, double door) with capacity 40 Amps triple pole & neutral (TPN) MCB incomer housing including for circuit operation of power tool motor control with 02 Nos of 09 Amp contactors and raise lower push button for mast including 35 sqmm incoming and 16 & 2.5 sqmm outgoing terminal complete all as specified and directed by Engineer-in-charge.
S&F in replacement three phase 1 HP integral motor, 6 poles, single speed, 415 volts, 50 Hz complete with connections including suitable size stainless steel chain for lowering down / up high mast assembly complete all as specified and directed by Engineer-in-Charge.
Dismantling existing unserviceable cross-arms of M.S. channel or angle sections etc. of any size and type complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down insulators of any type and size complete all as specified and directed by Engineer-in-Charge.
Disconecting and taking down existing unserviceable bracket and unserviceable street light fittings of any type/ make and refixing in existing or other position including connection with cable PVC insulated stranded copper conductor, 1100 volts grade, 1.5 sqmm 3 core size of ISI marked from security light to pole box along with accessories as directed by Engineer-in-charge. Notes:- (i) Any T & P and Ladder wheel required for the work shall be arranged by the Contractor. The rate of this aspect is included in this item and nothing extra shall be paid on this account.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
S&F street light pole box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 65 for outdoor Installation with internallly embedded gasket (PUR) including MCB SP 6 Amps 01 No along with left side hinge door (notch arrangement not acceptable) & premoulded knockout all sides including back of the base must. The box fitted with 10 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos. Make :- Syntex / Hensal / Schneider Notes :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
S & F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 150mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
S&F steel tubular swaged pole 09 meter long type 410 SP-31 and including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint to remaining portion of pole, clamps etc and marking pole number with synthetic enamel paint black colour in 80mm high letters over 150mm dia yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note :- Earthwork, PCC in foundation & coping shall be meaasured and paid saperately under respective items of BOQ.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in L & T / Havells / Schneider Make of MCB :- Legrand Cat Part No 408593 or equivalent in L & T / Havells / Schneider
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F street light bracket made out of 32mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing LED Street / Security light fitting of 60 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 110 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Crompton Cat Part No LSTP-60-CDL-M / Havells Cat part No. ENDURAPEARLNEOSL60WLED757PASYTOPC / Wipro cat part No LR02-671-XXX-57-G2 or equivalent in philips
Notes for srl Item No 21 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F three phase automatic street light switch suitable for 5 KW load complete with Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be platform mounted and structure must be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD (Swadeep 02EC5KW3P) / Siemens / Legrand / Indo Asian
S&F in replacement three phase load 5 KW automatic street light switch using NATURE SWITCH for automatic switching of (ON/OFF) of all 3 phase of street / security lights and digital timer switch (L&T make or equivalent) for switching (ON/OFF) 2 phase (out of 3 phases) at pre-defined timing during night including contractors, 3 Nos incloming -outgoing MCBs of 20-25 Amps each & copper circuit wiring of minimum 10 sqmm. automatic switch ON of all 3 phase as at DUSK based on LUX (30 LUX) level of natural light. Automatic switch OFF all street light as DAWN based on the LUX level (10 lux of natural light). First phase (red) to operate full night, second phase (yellow) and 3rd phase (blue) can be switched OFF at a pre-define time during night (Say 11:00 PM) and switched ON again at a pre-defined time during early morning (Say 4.00 AM) before finally switching OFF automatically at DAWN. Bypass option for bypassing both sensor and timer. The infrared sensoned based nature switch along with digital timer should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid (hensal make or equivalent junction box) confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be platform mounted and structure must be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD (Swadeep 02EC5KW3P- Dual) / Siemens / Legrand / Indo Asian
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
Supply, installation, testing and commissioning Split Type Air conditioner Electric driven (Single phase) 1.5 Ton, five Star rating capacity with remote control including complete assecories all as per manufacturer's instructions in all respect as directed by Engineer-in-charge. Make:- O-General Model No ASGA18FUTC / Blue star Model No. IC318XATU / Carrier Model No. JTKJ50 Note :- Voltage stabilizer of required capacity shall be measured and paid for separeltly in respective item of BOQ.
Supply, installing & testing Voltage Stabilizer of capacity 5 KVA copper wound for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 280V output voltage 230 V with accuracy of + 5% complete all as specified and directed by Engineer in charge. Make :- POWER TECH / VINTEK ELECTRONICS (VOLINA) / VINITEC ELECTRONIC LABORATORY (VINITEC) / Godrej
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 27 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 27 above but cable of cross sectional area 25 sq mm 4 core and including taking down old cable
All as per item No 27 above but cable of cross sectional area 6 sq mm 5 core and including taking down old cable
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 31 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 37 above but including taking down old tubing
All as per item No 37 above but 50mm bore tubing and including taking down old tubing
All as per item No 37 above but 32mm bore tubing
All as per item No 37 above but 15mm bore tubing
S&F in replacement of dry sealed maintenance free battery, direct current backup system 12 volts, 42 AH suitable for 15 KVA UPS system with 2 year replacement warranty from manufacturer complete all as specified and directed by Engineer -in-Charge.
Servicing / checking by authorised service engineer of OEM of complete three phase UPS 15 KVA (Make - Microtek) after opening and disconnecting of all component / parts and incoming / outgoing electric supply and cleaning, checking of serviceability of all components and connected items and reassembling of the same with replacement of the following items with new :- (a) Silicon-controlled rectifier (SCR) module - 03 Nos (b) Insulated-gate bipolar transistor (IGBT) - 05 Nos (c) Programming driver card - 02 Nos (d) Cooling fan 240 volts - 01 No After repair reconnecting of incoming and outgoing connection of UPS and fix in its original position and testing for satisfactory working complete set to work etc complete all as specified and as directed by Engineer-in-charge. --------------------------------------------------------------------- Note :- A sum of Rs. 159774/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 21 (Schedule of Credit) of Tender documents.
GURDEEP SINGH AND COMPANY
SRI SAI CONSTRUCTION COMPANY
M/S GODARA CONSTRUCTION CO.
M/S R. K CONTRACTOR & SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .