Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC 35 DHARSA MAHITAL KHAN S BYE LANE JIGACHA MUKHERJEE PARA HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.2 L+₹76,093 (3.91%)Rejected-Finance 221 3 SALT LAKE SECTOR II KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L2 | Rejected-Finance 2ND LOWEST BIDDER | |
| 3 | L3₹21.9 L+₹2.4 L (12.4%)Rejected-Finance AT G 2 BIDHAN NAGAR PO MEDINIPUR PS KOTWALI PASCHIM MEDINIPUR 721101 | MEDINIPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L3 | Rejected-Finance 3RD LOWEST BIDDER | |
| 4 | L4₹23.0 L+₹3.5 L (18.0%)Rejected-Finance 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L4 | Rejected-Finance 4TH LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹51,937
Closing Date
1 Jul 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, SWEC, PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
EI works for (GPLUS3) model for single 100 bedded covid ward at Nayagram Super Specialty Hospital, in the district of Jhargram----External Electrical Installation with allied works
2023_WBPWD_539223_1
WBPWD/SE/SWEC/NIQ07/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
JHARGRAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹51,937
O/O of SE, SWEC,PWD, PWD Compound, Midnapur
11 Mar 2025
10 Jun 2023
3 Jul 2023
10 Jun 2023
1 Jul 2023
15 Jun 2023
14 Jun 2023
Amount
PART-A [EI WORK FOR SITC OF DG SET]
Construction of suitable foundation of size 6mtr(L) x 2.5mtr(W) x 2.5mtr(H) made of 6 inch thick RCC structure with 12 mm MS rod binding with 8 mm connecting rod at base and top and sand filling as directed by EIC)ordinary cement concrete mix 1:5:3 with graded stone chips of 20mm pakur variety laying concrete base(1:3:6) using 40mm down stone metal & single brick flat soiling of pickle jhama brick incl. at shuttering work by 25mm to 30mm thick wooden plank also at base & top & base& sand filling as directed by EIC &net guard shed work incl. cable, pipe protection, earthing arrangement for DG set as per direction of EIC.
Construction of suitable and needed size triangle structure shed for 200KVA DG set by GI Pole structure on existing foundation of size 6mtr(L) x 2.5mtr(W) x 2.5mtr(H). The no of GI pole will be 06 nos and min. height of 4.5mtr and the shed will be sheded by corgated fibre sheets of 6.5 mtr length and width of 5 mtr.. The total work will be done as per EIC.
Supply & delivery and pouring including transportation of HSD oil
Supply, Installation and fixing of GI made circular structure necessary size (approx. 125mm/150mm) smoke chimney for exiting of DG smoke upto above of 4 storied roof top
Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(make-L&T/ Siemens/ Havells)
Supply & Delivery of 3.5 core 240 sqmm Al/A XLPE 1.1kV grade cable (make: Gloster/Havells/Polycab/RR Kabel)
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of 3.5 Core 240 sqmm cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables
3.5 core 240 sqmm
Finishing the end of 240sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
3.5 core 240 sqmm
Supplying & fixing 100mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Supply & Delivery of following armoured Cu Cable: (Make: Havells/Polycab/ Gloster/RR Kabel)
2 core 10 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
2 core 10 sqmm
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
2 core 10 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes
2 core 10 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
2 core 10 sqmm
Supplying & fixing 32mm Dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Excavation of morrum soil for installation of Earth Electrode and filling & ramming. For Morrum Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level(TATA Medium)
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
PART-B [EI WORK FOR SITC OF LIFT]
S& installation of industrial type wall mounted LT panel board comprising of the following electrical accessories fabricated with 40x40x5 mm MS angle & 40x5 mm MS flat with necy. Welding incl. painting with 2coat synthetic enamel paint over 1 coat of RO primer as per direction of EIC INCOMING a) S&f 415V 63 A TPN SDFu with 3nos HRC fuse in sheet steel enclosure(L&T)-1no Busbar 4bar 100/125A tinned copper 4x15x3 mm basbaur(suitable size) Sheet metal box(16 SWG) with hinge type door in two part with locking arrangement with telescopic screw. as per direction of EIC--1set Outgoing c) S&F 415v 32 A TPN SDFU with 3 no HRC fuse in sheet steel enclosure(L&T)--2no d) S&F 240V 32A DP mainswitch in sheet steel enclosure(havells)--1nos Interconnection Interconnection is tobe made through suitable size throat box/cable end box(16swg) incl. S&f the same with suitable PVC 'FR' cu wire(incl Socketing the END) in between main switch to busbar, metering circuit with 1.5sqmm single core stranded FR PVC cu wire with proper socketing & taping(R,Y,B &N) Reading arrangement a) 0-500V 4" dial square type voltmeter(AC/DC)-1no b)0-100A 4" dial square type Ammeter(AC/DC)-1no c)100/5A CT coil(kappa make)-3nos d) 4step ammeter/voltmeter slector switch-2nos e)LED type indicating lamp(RYB)- 3nos f)sliding lock fuse for indicator -3nos
Supply only 1.1KV grade 4core 35 sq mm PVC AL/Armoured cable (make : Polycab /Havells /Gloster / RR Kabel).
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of Following XLPE/A, Al cable
4core 35 sqmm XLPE/A, Al cable
Finishing the end of following XLPE/A, Al cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4core 35 sqmm XLPE/A, Al cable
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl, Inter connection with suitable size of copper wire and neutral link & provision for earthing aftachment (4 way, Enclosure - 607715) With S & F 415 V 63 A FPMCB isolator as incomer and 240 V, 6-32A SPMCB of Breaking capacity 10KA & C characteristics 12 nos as outgoing (Make-Legrand /L&T/Hager)
Supplying and fixing 250 V. 6-16A per way. (2+8 way)SPN MCBDB with SS enclosure doubledoor with 1P-42.43 protection with DP Isolators as incomer and SPMCBS ('C' Curve, IOKA) as outgoing concealed in wall after cutting the wall & mending good the damages to orginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Enclosure (607711), 01 no 40 A DP Isolator as incoming and 8no. (6-32A) SPMCB C-Curve, 10KA) as outgoing (Make-Legrand/L&T/ Hager) as per direction of EIC -- for machine room lighting & lift Motor
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC in 2no. 25mm size PVC rigid conduit FR"
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 11 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.[on board]
Supply & Fixing 240 V, 02 nos 6 A, 3 pin Modular type plug socket (Brand & colour approved by EIC) with 02 nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand & colour approved by EIC)) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter [ 250V 12'' sweep,920RPM ]
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For AL [ 250V 12'' sweep,920RPM ]
Supply & Delivery of Exhaust Fan [ 250V 12'' sweep,920RPM ] (make EPC heavy duty)
Supply and fixing of 12 SWG 600mm (24'') stainless steel net guard for 12'' exhaust fan with necessary accessaries i.e. nut, bolts,washers etc. on wall incl. fixing
Supply and Delivery of AIR CIRCULATOR METAL HEAVY DUTY (450 mm)(Make- USHA DOMINAIRE WALL FAN(METAL BLADE)/ EPC/Orient/Cinni Full metal body]
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. Making necy. connections etc
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
supply & Delivery of the 40W LED tube [Make – Phillips cat no.-BN021 LED 40S-6500 PSU GR ) or equivalent make of Crompton / Bajaj / Havells
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
Supplying LED bulk head light fitting (Philips cat no.-WT202W LED6S NW PSU S2 PC or equivalent make of Crompton / Bajaj / Havells)
S & installation of single phase Timer DB comprising of (2+10) way SPNMCBDB ( Conceled in wall) , 32 A DP MCB , analog time switch ,32 A DP power contactor , 25 A MCB change over with suitable interconnection [Make : L&T / Legrand / Siemens]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for AC installation, per storey of building per vertical run
Excavation of morrum soil for installation of Earth Electrode and filling & ramming For Morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level(TATA Medium)
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
PART-C [BALANCE EI WORK]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
supply of 40W LED tube [Make – Phillips cat no.-BN021 LED 40S-6500 PSU GR ) or equivalent make of Crompton / Bajaj / Havells
S &D of 1200 mm AC celing fan. (Make -Usha STRIKER 1 STAR (Safety Wire & S3 / P2 Capacitor)/Equivalent model of Orient/ Crompton Greaves ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter [250V 12'' sweep 920 RPM]
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For AL
Supply & Delivery of 250V 12'' sweep 920 RPM exhaust fan (make EPC heavy duty)
PART-D [EI WORK FOR SITC OF HVAC WITH NEGATIVE TEMPARATURE SYSTEM]
Supply & Delivery of Following armoured Cu Cable: (Make: Havells/Polycab/ Gloster/RR Kabel)
4 core 25 sqmm
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
4 core 25 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes
4 core 25 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
4 core 25 sqmm
Starter Pannels Ductable AC machines: Supply and fixing of timer control switch for controlling Ductable AC machines made of suitable size MS sheet duly Power coated paint with IP - 43 protection with front door locking arrangement with all connection and comprising with following accessories including necessary connenctions and earthing attachment on angel iron frame on wall / embedding in wall as per instruction of EIC. a) 63A FP MCB, 30MA -1 nos. (Make - L&T/ equivalent of Legrand, Simens). b) 40A Four Pole Contactor - 4 nos. (Make - L&T, MU type / equivalent of Simens) c) Daily & weekly programmable basis digital time switch, min switching time 1 min, 25 ON/OFF programs, 6 yrs. Battery backup, settable DST & key pad lock features. - 1 no. (Make-L &T - GIC make / equivalent Legrand make) e) Start / Stop push button (1+1)- 2 Set (L&T/ Simens) f) RYB/Amber LED indication Lamp, 240V AC -2 set (L&T / Simens) g) Aux-Relay - 2 No. (L&T / Simens) h) 32A rated Four pole terminal - 04 nos.
Starter Pannels Exhaust System: Supply and fixing of timer control switch for controlling Ductable AC machines made of suitable size MS sheet duly Power coated paint with IP - 43 protection with front door locking arrangement with all connection and comprising with following accessories including necessary connenctions and earthing attachment on angel iron frame on wall / embedding in wall as per instruction of EIC. a) 32A FP MCB, 30MA - 1 nos. (Make - L&T/ equivalent of Legrand, Simens). b) 32A Four Pole Contactor - 2 nos. (Make - L&T, MU type / equivalent of Simens) c) 9-14A Over load Relay - 2 nos. (Make - L&T, MN2 Type/ equivalent of Simens) and Current monitoring relay- 2 no. (L&T: ) d) Daily & weekly programmable basis digital time switch, min switching time 1 min, 25 ON/OFF programs, 6 yrs. Battery backup, settable DST & key pad lock features. - 2 no. (Cat no. - 67DDT0. - L &T - GIC make / equivalent Legrand make) e) Start / Stop push button (1+1)- 2 Set (L&T/ Simens) f) RYB/Amber LED indication Lamp, 240V AC -2 set (L&T / Simens) g) Aux-Relay - 2 No. (L&T / Simens) h)32A rated Four pole terminal - 02 nos.
Supply & Fixing of Water proof Loop Box for AC Machine ODU with 32 Amp. Isoletar(Make-Sintex or Equivalent)(Isoleter Make - L&T /Legrand /Siemens)
Supply & Fixing of Water proof Loop Box for Exhaust Fan with 32 Amp. Isoletar(Make-Sintex or Equivalent)(Isoleter Make - L&T /Legrand /Siemens)
Supply and laying of 4 Core 4 Sqmm copper cabele,1.1 KV, PVC insulated un armoured copper cable laying through medium class PVC conduit with saddling,supports etc. incomplete shape. Makes: RRKabel / Havells / /Polycab Conduit Makes :AKG, Prestro
Supply and laying of 3 Core 2.5 Sqmm copper cabele,1.1 KV, PVC insulated un armoured copper cable laying through medium class PVC conduit with saddling,supports etc. incomplete shape. Makes: RRKabel / Havells / /Polycab Conduit Makes :AKG, Prestro
SILICON SOFTWARE
M/S JOGMAYA ENTERPRISE
MAHESWAR ELECTRICAL INDUSTRIES
technical_1126708.pdf
PDF • 0.56 MB
techsummary_1126708.pdf
PDF • 0.57 MB
finance_1126708.pdf
PDF • 0.56 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_1126708.pdf
PDF • 0.70 MB
AOC7.pdf
PDF • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .