| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | ₹11.1 L Quoted ₹9.4 L | L1 | Accepted-AOC On being L1 |
| 2 | L2₹10.9 LRejected-Finance AT BUDHIJAM COLONY ORIENT COLLIERY BRAJRAJNAGAR JHARSUGUDA ODISHA 768216 | JHARSUGUDA | ODISHA | 768216 | ₹10.9 L | L2 | Rejected-Finance On being L2 |
| Sl No | Description | Qty | Unit | M/S LIGHT PALACE L1 | M/s BIKASH ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required- Above 10.00 metre and upto 12.00 metre | 65 | Nos. | 3,645.49 ₹2.4 L | 4,201.12 ₹2.7 L |
| 2.00 | Erection of steel tubular pole length exceeding 12 mtrs but not exceeding 16 mtrs in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc as req. | 5 | Nos. | 4,498.22 ₹22,491.10 | 5,183.82 ₹25,919.10 |
| 3.00 | Supplying and erection of galvanised stay set for 11kV overhead lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turnbuckle (20 mm X 600 mm),7/ 4.00 mm dia G.l stay wire and 11kV strain insulator etc in cement Concrete 1:3:6 (1 cement: 3 coase sand: 6 graded stone aggregate 40 mm normal size) foundation incluiding exavation and refilling etc. as required. | 35 | Set | 2,816.97 ₹98,593.95 | 3,246.32 ₹1.1 L |
| 4.00 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6mm
(7.14 kg per metre) double pole cross arm for three wire 11kV overhead line conductors complete with through bolts and nuts for
clamping to the poles, 50 mmX6 mm M.S. flats welded on one side
to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/fittings, bolts, nuts and washers etc and painting with primer and finish paint as required. | 14 | Set | 2,409.16 ₹33,728.24 | 2,776.36 ₹38,869.04 |
| 5.00 | Supplying of channel iron 75 mm X 40 mm X 6mm (7.14 kg per
metre) cross arm for two 11 KV over head line conductor complete 50 mm X6 mm MS plat iron clamps, iron clamps, bolts and nuts incluiding drilling holes for insulator pins, bolts, nuts and washer etc and painting with primer and finish paint as required | 42 | Nos. | 1,110.43 ₹46,638.06 | 1,279.68 ₹53,746.56 |
| 6.00 | Supplying of 75 mm X 40 mm X 6mm channel iron pole top bracket /cross arm for single 11/22/33KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required | 42 | Nos. | 258.78 ₹10,868.76 | 298.22 ₹12,525.24 |
| 7.00 | Supply of two lengths of angle iron 75 mm X 40 mm X 6 mm (4.5 kg per metre) double pole cross arm for 11kV over head line conductors complete with through bolts and nuts for clamping to the primer and finish paint as required for Cradle guard | 5 | Set | 1,228.79 ₹6,143.95 | 1,416.08 ₹7,080.40 |
| 8.00 | Supply of angle iron 75 mm X 40 mm X 6 mm (4.5 kg per metre) for running earth support complete with through bolts and nuts for clamping to the primer and finish paint as required | 56 | Set | 560.6 ₹31,393.60 | 646.04 ₹36,178.24 |
| 9.00 | Erection of double pole 3 wire cross arm for 11 KV/22KV/33KV
Overhead lines etc. as required | 14 | Each | 471.29 ₹6,598.06 | 543.12 ₹7,603.68 |
| 10.00 | Erection of pole top/straight two wire/ V shape two wire, angle iron/
channel, cross arm on steel tublar/PCC pole for 11/22/33 KV as
required. | 150 | Set | 208.21 ₹31,231.50 | 239.94 ₹35,991 |
Updated dates
Tender Value
₹20.7 L
EMD Value
₹25,900
Closing Date
13 Mar 2026, 5:00 pmClosed
Pramod Swarnkar, Sr. Manager (EnM)
Office of the Project Engineer (EnM), ILBL OCP, Lakhanpur Area, MCL
Extension/diversion of 6.6KV HT Power line for providing power supply from Chharla Siding to construction site to Silo Phase II Conveyor/workshop of ILBL OCP, Lakhanpur Area, MCL
2026_MCL_354829_1
MCL/LKPA/ILBL/ePC-EM/25-26/59
Open Tender
Electrical and Maintenance Works
30 days
EnM Dept., ILBL OCP, Lakhanpur Area, MCL
Please refer Tender documents.
4 documents required · 4 mandatory
₹25,900
15 May 2026
27 Feb 2026
16 Mar 2026
27 Feb 2026
13 Mar 2026
27 Feb 2026
27 Feb 2026 - 2 Mar 2026
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required- Above 10.00 metre and upto 12.00 metre
Erection of steel tubular pole length exceeding 12 mtrs but not exceeding 16 mtrs in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc as req.
Supplying and erection of galvanised stay set for 11kV overhead lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turnbuckle (20 mm X 600 mm),7/ 4.00 mm dia G.l stay wire and 11kV strain insulator etc in cement Concrete 1:3:6 (1 cement: 3 coase sand: 6 graded stone aggregate 40 mm normal size) foundation incluiding exavation and refilling etc. as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6mm (7.14 kg per metre) double pole cross arm for three wire 11kV overhead line conductors complete with through bolts and nuts for clamping to the poles, 50 mmX6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/fittings, bolts, nuts and washers etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6mm (7.14 kg per metre) cross arm for two 11 KV over head line conductor complete 50 mm X6 mm MS plat iron clamps, iron clamps, bolts and nuts incluiding drilling holes for insulator pins, bolts, nuts and washer etc and painting with primer and finish paint as required
Supplying of 75 mm X 40 mm X 6mm channel iron pole top bracket /cross arm for single 11/22/33KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Supply of two lengths of angle iron 75 mm X 40 mm X 6 mm (4.5 kg per metre) double pole cross arm for 11kV over head line conductors complete with through bolts and nuts for clamping to the primer and finish paint as required for Cradle guard
Supply of angle iron 75 mm X 40 mm X 6 mm (4.5 kg per metre) for running earth support complete with through bolts and nuts for clamping to the primer and finish paint as required
Erection of double pole 3 wire cross arm for 11 KV/22KV/33KV Overhead lines etc. as required
Erection of pole top/straight two wire/ V shape two wire, angle iron/ channel, cross arm on steel tublar/PCC pole for 11/22/33 KV as required.
Supply and erection of 11 KV grade, composite Silicone rubber disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required Minimum Failing Load-45KN, 320mm Creepage distance . As per IEC 61109, Grey Colour (As per TPS)
Supplying and erection of 11 kV grade , 5kN, Silicone rubber, Fibre Glass rod (FRP), Boran free, Composite polymer pin insulator complete with large steel head G.I. pin, nuts,washers etc. as required. Sectional Length -342 ± 20 mm, Creepage distance-320 mm minimum, As per IEC 61109
Erection of AAA conductor of 125 sqmm diameter including binding etc. as required. (55 x 50 x 3 x 0.342kg/mtr = 2822 Kg) + (2822*3% wastage=85 kg) = 2907 kg
Erection of AAA Conductor upto 55 sgmm diameter 7/3.15mm) including binding etc as required. (55 x 50 x 0.149 kg/mtr = 410Kg) + 12 kg (3% wastage) = 422 kg
Supply, Weaving/fabrication and erection of craddle guard as required
Dismantling of overhead lines comprising of copper / aluminium over head conductor, G.I. wire, cross arms insulators etc as required
Dismantling of pole/street light standard/strut embeded in cement concrete foundation etc.as required
Supply, installation and commissioning of maintenance free earthing system, earth resistance upto 01 ohm with test certificate. Specification: Earthing electrode-50/3 MTPCB, 3M X 58mm, THK:50, 250 Micron copper coating on GI Pipe, Terminal Size-40/6, Inner strip-25x3, Filling material-BFC silica base bentonite powder 5OKg, Earth pit digging by spiral machine, Pit Cover- Poly Plastic (BIG) Primary earthing electrode (outer pipe) of 99.9% pure copper coating(250micron) on GI Pipe( diameter 58mm)X3mtrs. The hollow space of the electrode is duly filled with a highly conductive and non corrosive compound (graphite power) which safeguards the secondary electrode getting corrode over a long period of time under the soil. Also the compound ensures the easy distribution of leakage/fault current lands on the electrode, Both the ends of the electrode are permanently sealed and the top portion of the earth electrode is compressed to form and extended lead with 2 holes on the terminal for connecting to the load/equipment. (suitable conductor/cable will be supplied by dept as per requirement and purpose)
Dismantling and re-erection of 11 kV Grade 400A/800A double break Horizontal type GOAB Switch (Complete with all limbs, vertical pipe support, Structural Steel, joist support for handle ) on the double pole cross arm.
Total impact of Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.69 MB
Tendernotice_2.pdf
PDF • 1.02 MB
BOQ_367691.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid