| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.5 L+₹2.3 L (5.38%)Rejected-Finance 245A 7A 1 JAYANTIPUR GOKUL AWAS YOJNA SULEM SARAI PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹47.6 L+₹4.4 L (10.2%)Rejected-Finance HIG 40 TYPE B DEV PRAYAGAM ADA COLONY JHALWA PRAYAGRAJ U P 211015 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211015 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹47.7 L+₹4.5 L (10.3%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹48.3 L+₹5.0 L (11.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹44.8 L
EMD Value
₹89,700
Closing Date
24 Jul 2023, 10:00 amClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIR TO ROOF TREATMENT AND CHAJJA REPAIR AT CERTAIN LOCATIONS UNDER GE (AF) BAMRAULI
2023_MES_606540_1
8820/E8
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹89,700
Yes
23 Sept 2023
28 Jun 2023
25 Jul 2023
28 Jun 2023
24 Jul 2023
14 Jul 2023
Amount
Demoliton of cement concrete (un reinforced) of any description and in any position not other wise specifically provided for complete all as specified and directed.
Demolition, Cement concrete (reinforced) of roof and floor,beams ,staircase,landing,chajjas,lintel and similar suspended work in any position complete all as specified and as directed by the Engineer-in-Charge.
M & L for Reinforced cement concrete design mix 1:1:5:3 (20mm graded aggregate)in chajjas beams lintels cantilever fair finish using necessary form work complete all as specified and as directed by the Engineer-in-Charge(note form work paid seprately)
M&L for cutting channels groves or rebates where reinforcement is cut through n exc 15cm girth and trimming the surface
M&L for formwork to chullah hoods, chajjas trough,beam and similar item including edges for fair finished surface all as specified and directed by engineers incharge.
M & L for 75mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate complete all as specified and as directed by the Engineer-in-Charge
S & F TMT bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips.
Taking down cement plaster or cement lime plaster of any description including racking out joints, haking for key , scrubbing down with water etc and prepare to receive new plaster complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars etc from parapete etc and removal unserviceable brick/brick bats complete all as specified and directed.
M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 as in parapets etc complete all as specifed and directed.
M&L, rendering 15mm thick in cement mortar (1:4), on fair faces or brick work or concrete surfaces, finished even and smooth without using extra cement and mixed with water proofing compound @ 200ml per 50 Kg weight of cement (1 Bag). (Note: WPC will be measured and paid separately).
M & L for Rendering 10mm thick in cement plaster 1:6 on any fair faces of brick work or concrete surfaces finshed even
M&L for 10 mm thick rendering in CM (1:3) on fair faces of brick work or concrete ceiling surfaces finished even and smooth without using extra cement etc complete all as specified.
M&L for forming external or internal rounded angles,exc 80mm but n exc 200mm girth
M&L for cement concrete etc B-0 (using 12.5mm graded stone aggregate) benching,coping,lintels, slope etc as per existing or as directed including finished surface even and fair complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling surfaces and applying three coats of white wash etc complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) , including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).
S&F in repairs 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls .
S&F in repairs 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls .
S&F in repairs 110mm bore PVC (SWR) bends any radius.
Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Dismantling of brick tiles laid bedded and pointed in any morter or brick tiles on roof , floors, channels, kerbs, aprons etc,cement concrete of any description & in any position not otherwise specifically provided for.
Cleaning the roof surfcae from dust /dirt and any other foreign materials and applying a coat of bituminius primer @ 0.30 liters per square meter uniformity after the surfaces fully dried complete applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm completeall and laying APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer.
M&L for 40mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof padding, benching existing roof slab to slope as per existing or as sirected including finished surface even and fair complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:4) cover concrete surfaces of roof, mixed with @ 200ml liquid water proofing compound by 50Kg weight of cement (1 bag) as per manufacturerrs instruction inclduing finishing surfaces even and smooth without using extra cement complete all as specified and directed. (WPC shall be measured and paid separately). (Note: WPC will be measured and paid separately).
M&L for cement concrete tiles 25cmx25cmx20mm thick machine pressed set jointed and pointed in neat cement slurry in floors and cut polished over roof treatment, laid over and including 15mm thick screed be din cement mortar (1:6) mixed with and including polymer based liquied water proofing additive @ 200ml liquid water proofing compound by 50Kg weight of cement (1 bag) or as per manufacturers specification and joints of cement concrete tiles shall be filled with cement mortar (1:4) mix with complete all as specified and directed. (note-15mmthick screed bed in cement mortar (1:6) and water proofing compound paid sepratevely)
M&L for 15mm thick screed be din cement mortar (1:6) mixed with and including polymer based liquied water proofing additive @ 200ml liquid water proofing compound by 50Kg weight of cement (1 bag) or as per manufacturers specification and joints of cement concrete tiles shall be filled with cement mortar (1:4) mix with and including 5% curde oil complete all as specified and directed.
Supply only liquid integral water proofing compund. Make Dr Fixit Pidipfoor LW+.
M&L for cutting out cracks to V section in existing roofs or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clen dry sand (1:1) (by weight) complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cills bencing and other similar bands, plinth courses, parapets, coping bed plates and the like inclduing weathering, slightly rounded or chamfered angles and throating finishing surface even and smooth as directed inclduing use and waste of form work complete all as specified and directed.
S&F 0.63 mm th plain galvanised sheeting fixed on crumple joints fixed with screw on wall/ roof as required complete all as directed.
M & L for dismantling down decrepit existing unserviceable cement plaster loose/unsound debilitate cement concrete of any description and in any position from existing external/Internal surfaces of RCC/slab/beam/columns/RCC fascias etc. average profundity 40 mm (Max. hight up to 8 mtr. from existing ground level) and disposal of unserviceable material ie Debris and Rubbish outside MOD land at placec specified by local bodies upto 50 metres of lead including cutting of all edges, making square shoulders of the cavities roughening the smooth surfaces, abrade out/expel corrosion all loose/scale/rust etc from the observed reinforcement by applying rust remover and cleaning the steel reinforcement properly, and after that applying Protezion Ferro single component cementations on observed reinforcement surfaces to create a continuous film not less than 1 mm thick and preparing the surface to get grout mortar including providing necessary proportions, bracing and runners to relieve the members from the load coming on working platform as required and as per design and pattern including preparing the surface to coordinate with the existing surface, using alkaline based rust remover for corroded steel structure and concrete remover cleaning etching Agent Chemical make of Thermax/Torchtar Ltd./Ooms Polymer Ltd. of cementitious corrosion inhibiting using primer mucis protezione and Anti corrosive primer exposed steel and concrete surface Chemical Make of Thermax/Torchtar Ltd./Ooms Polymer Ltd. Complete all as specified and directed by Engineer- in -charge. Note: - This item shall be undertaken by the authorized rep of manufacturer.
M & L for fixing welded MS wire mesh weighing not less than 2 Kg/Sqmt and applying using mucis protezion ferro mono primer and Anticorrosive primer uncovered steel and concrete surface chemical Single component, cementitious corrosion inhibiting primer of make Thermax/Torchtar Ltd./Ooms Polymer Ltd.on uncovered steel reinforcement and wire mesh having mixed density of 2.01.02.05, adhesive on bond strength- 1 N/mm touch drying time of 10-15 minutes and applying 10 mm thick cement mortar 1:4 with using integral water proofing liquid admixture for concrete mortar and integral water proofing compound for cement based concrete and mortar chemical make of Thermax/Torchtar Ltd Ooms Polymer Ltd.100/L 1.1-1.2 gm/cc, chloride content: nil as per IS 2645-2003 & using acrylic polymer base bonding agent and acrylic emulsion modifier and water based concrete bonding agent chemical STD having specific gravity of 1.02) of Thermax/Torchtar Ltd Ooms Polymer Ltd. in ratio as per recommendation of manufacture total chemical not less than 8 % by weight and providing rendering 25 mm layer of mortar single component polymer modifier using single component thixopropic fibre reinforced polymer modified alkali resistant synthetic fibres for exceptional resistance cracking complies repair mortar ratio1:1:4 make of Thermax/Torchtar Ltd./Ooms Polymer Ltd./ to achieve compressive strength of 15 N/mm in 1 Day, 25 N/mm in 3 days adhesion bond strength of > 2 N/mm providing Rendering 10 mm thick in cement mortar and all as specified and directed by Engineer-in- charge. (Make : Fosroc) Note: - This item shall be undertaken by the authorized representative of manufacture.
M&L for drilling hole chemical anchoring of reinforcement on existing columns/chajjas/Top beams/Bottom beams/Circular Column beams/Braces with Hiti HIT-HY 70 or equivalent in Thermax/Torchtar Ltd./ooms Polymer Ltd./ STP Ltd, minimum hole depth 100 mm, steel bar 12 mm dia and drill bit dia 14 mm, complete all as specified and directed by Engineer-in-charge. Make: HT-V-R M12X150 OF Hilti using Polyster Resin based Anchoring material for Horizontal vertical & large Annular Applications and Anchosin P Fix.chemical of Thermax/Torchtar Ltd./Ooms Polymer Ltd. Complete all as specified and directed by Engineer-in-charge. (Make : Fosroc) Note:- This item shall be undertaken by the authorized rep of manufacturer
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position exc 250 ltr n.exc 500 ltr cap etc complete all as specified and directed.
Demolition of RCC 500/1000 ltr water tank of any description and in any position not otherwise specifically provided for
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling water tanks all as specified.
S&F 20mm dia Stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed in repair.
S&F 20mm dia ball valves high pressure of with epxy coated aluminium rod and high density plastic ball screwed for iron pipe and all as specified.
Taking up or down steel water tubing galvanised and removing to store 15 mm dia
Taking up or down steel water tubing galvanised and removing to store 20 mm dia
S&F 15mm dia medium grade galvanized water tubing with all necessary fittings and fixed complete walls.
S&F 20mm dia medium grade galvanized water tubing with all necessary fittings and fixed complete walls.
S&F gate valves gun metal with iron wheel head screwed both ends for iron pipes and fixed 25mm
M&L for repairs to sunken portion/floor including demolition of existing PCC,WC,P/S Trap and removing the material outside MD land and cleaning with the wire brush to dry and applying one coat of URP in cement in ratio 1:1 @ 1liter per Sqm. After drying of this process applying two coats of pidifin2K @ 01 liter/Sqm for two coats and minimum time gap between each coat is 4 hours and 15 mm thick rendering in CM 1:4 including finished even & smooth without using extra cement complete all as specified and directed. Notes:- (a) Area of measurement will be floor area which includes side walls of the sunken portion (a) The pidifin2k chemical treatment shall be carried out by authorized technicians of Dr Fixit (b) 10 years written guarantee (from the certified date of completion of work) shall be obtained from the Dr Fixit and submitted by the contractor.
S&F (in repair) vitreous china squatting pan Orissa Pattern size 580x440mm white with integal foot rest (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe complete including trap, set with cement concrete complete all as specified and directed.
Supply and fixing(in Repair) vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) and P or S trap including connection to drain (or outgoing pipe) and to flushing pipe anti-syphonage pipe etc complete all as specified and directed . including plastic water closetseat closed pattern with flat bottom and cover and mild steel chromiunm plated or aluminum hinging device
Supply only low level cistern of 10 ltr cap PVC dual flush, symphonic action type , with inlet ball valve and float and handle 32 mm dia including bracket after fixing tiles etc including taking down existing complete all as specified and directed.
S&F in repair chromium plated fancy type Hand Jet spray (Health faucet) complete
Supply and fixing (in Repair) vitreous china wash hand basin, white, flat back, size 550x440mm excluding taps, waste, chain and plug and porcelain stopper but including MS brackets including PTMT waste coupling 32mm and cutting for and pining in ends of brackets complete all as specified and directed.
S&F in repair pedstal wash basin white flat back size 550x430mm approved quality (inclusive of 32mm dia PVC waste pipe ,connection pipeand waste coupling) fixed in position including removing the old unhygienic WHB complte all as directed.
Supply only 15mm dia pillar taps CP brass with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair including taking out the existing pillar tap complete all as specified and directed.(Weight not less than 450gms).
S&F in repair fancy type pillar tap swivel spout deck mounterd 15mm dia size with Screwed down high pressure,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
S&F only (in Repair) in 15mm bore dia two way Bib tap cast copper alloy with fancy handle ,screwed for iron pipe or for ferrue and fixed all as specified as engineer in charge
S&F in repair 15mm dia stope valves/angle cock fancy type cronium plated with long shank and cup (cost copper alloy screwed down, high pressure withcrutch or butter fly handle screwed both ends for iron pipe. (Weight not less than 350-450gms)
S&F in repair 15 mm bore (concealed) stop cock ISI marked, cast copper alloy, screwed down, high pressure, fancy type handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair Brass chromium plated shower rose 125mm size including Nipple, socket and other fittings etc complete all as specified.
S&F in repair towel rail 600mm long and 20mm dia of CP fixed with and including Chromium plated brass screws and wooden/plastic cleats
S&F in repair 15mm dia PVC connection of length 450mm fixed as in repair including taking out the existing unserviceable complete all as specified and directed.
S&F 100mm dia cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints,laid in trenches in floor. Etc complete
All as per item No. 60 above but 75mm dia ad fixed to wall
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as speified and directed.
M & L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
S & F for Glazed ceremic coloured printed tiles of size 450x 300mm x7mm thick as in dados, skirting, wall etc set jointed in neat cement slurry and pointed in coloured cement to match the tiles laid and including over 10 mm thick rendering in CM 1 : 4 laying glazed tiles in floors etc. complete all as specified and as directed by the Engineer-in-Charge
M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick joint free (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6) complete all as specified and directed.
Taking down Chowkats or frames with shutter not exceeding 1.5 Sqm each (without taking off shutters from the frames)
S&F powder coated anodised aluminium (shutter/ sliding/ fixed type) windows/ventilator with frame size 60x40x2.00mm thick and shutter with section bearing bottom 25x18x1.50, top 39.4x17.7 X1.50 mm ( if required suitable for moving over three track fixed over top of frame work , top and side section of size 61.6 x 31.75x1.5mm and bearing bottom track of size 61.6x 31.75x1.5mm or fixing with hinges including necessary aluminium jointing cleats, glazing cleats, rubber packing anodised snape beading, screws etc with 5mm thick sun control plain glass in panels incl all fitting and fixture SS wire mesh complete all as spesified and directed .
S&F powder coated anodised aluminium grill powder coated with 6X5 mm aluminium section having square gap of 100 mm thick with ficking rails of channels 12-15 mm or fixed in y chaneels at both side complete all as spesified and directed .
S & F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed by the Engineer-in-Charge
S & F for steel ventilator with top hung shutters including projecting type hinges with steel handle, and steel peg stay,fixed with 3mm thick sheet glass complete without glazing bars complete all as specified and as directed by the Engineer-in-Charge(note:sheet glass paid seprately)
Supply only for sheet glass 3.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F in repair for sheet glass 4.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane including hacking out etc complete all as specified and as directed by the Engineer-in-Charge
S&F mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed as in repair including taking down the unserviceable existing complete all as specified and directed.
S&F in repair mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed as in repair including taking down the unserviceable existing complete all as specified and directed.
S&F framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0
Providing & fixing ceiling with Semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles at all height with GRG (Glass fibre Reinforced Gypsum) False ceiling tiles of size 595x595 mm of approved texture design patterns having moisture content less than 2%, humidity resistance of 99%, NRC) .50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 Part4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L- shape level adjuster of size 85x25x2mm Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. Note : (i) Ceiling tiles shall be authorised brand of make as specified in Appendix 'B' to particular. (ii) Thickness og GI section shall not less be less than 3mm and shall be procured from the tile manufacturer. (iii) Section and hanging system shall have galvanising of minimum 90 grams per sqm and same make of tile. (iv) Work shall be executed by manufacturer's authorised vendor.
M&L for 16-18mm thick Granite(of any type) work (table rubbed and polished) in wall lining (veeneering to wall 12mm thick cement mortar cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S&F in repair Vitreous China urinals,solo bowl type (back or corner wall type)of 385x295x500 complete including providingand fixing plugs, bedding urinalagainst wall in cement mortar1:2, securing urinal to plugs withand including 60mm long brass screws, pointing around urinal back in cement; fixing automaticflushing cistern with brackets,ush pipe, grating and Union fixing supply pipe to flushing fordischarge pipe.
M&L soap dish chromium plated brass fixed with brass nuts as in repairsall as directed.
S&F in repair glass self of with heavy bracket fixed with SS screws in wall complete all as specified and directed
S/F in repairs CP Towel rail 600mm long fixed with and including chromium plated brass screws and wooden/plastic cleats all as specified
M & L for 75mm bore dia pvc floor /Nanhni trap with CP grating, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1all as specified and directed
M&L for complete removal for, plastered or unplastered surfaces of old ceiling surfaces and applying two coat of distemper oil emulsion etc complete all as specified and directed.
M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats of distemper oil-emulsion over a thin layer of 1.5mm thick wall care putty complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of 1.5mm thick wall care putty complete all as specified.
M&L for Washing rubbing down and stopping of distempered and painted surface and applying one coats of distemper oil-emulsion complete all as specified.
M&L for complete removal of existing treatment of old plastered surfaces of walls applying two coats cement based paint paint over a coat of chalk whitining primer etc complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion paint over a coat of primer with 2mm thick wall care putty etc complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over cement wash with white cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of celingand applying two coat of distemper oil emulsion etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces of celing and applying two coats of oil emulsion distemper over a coat of primer with 2mm thick wall care putty etc complete all as specified.
M&L for complete removal of existing treatment of old plastered surfaces of walls applying two coats exterior emulsion paint over a coat of primer with 1.5mm thick wall care putty etc complete all as specified.
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed by the Engineer-in-Charge.
M&L for preparation of old painted Steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed by the Engineer-in-Charge.
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI marked and including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:-
(a) One light/fan/bellpoint controlled by one switch single pole one way
(b) All as per item No 98 here-in-before but one 3 pin 6 amp switch socket out let independent .
(c) All as per item No 98 here inbefore but one 3 pin 6 amps socket outlet on the same board with other switch complete .
All as per item No 98 here-in-before but using 02 Nos. 4.0 sq mm size for main cable and 01 No.4 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board.
Supply and fix switch modular flush 6A single pole one way ISI marked
Supply and fix modular sockets 6 Amp 2 in 1 2/3 pin combined all as specified and directed.
Supply and fix switch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked
Supply and fix modular sockets 16 Amp 2 in 1 3/5 pin combined all as specified and directed.
Supply and fix ceiling rose surface bakelite 60x25mm three terminal
Supply and fix electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type
Supply & fix MCB DB SPN 12 way, double door, IP-43, IK-09, Isolated Neutral Bar and fixed flush to wall and suitable for universal mounting complete all as specified and directed.
Supply and fix MCB, single pole and neutral, 230 volts, 40 to 63 Amp rating, 'C' series fixed in DBs catered here-in-before.
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
S & F LED light fitting 10 Watt bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed.
S&F LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, system lumen efficiency >90 lumen/watt, 6500k/3000k and including connecting from ceiling rose to fitting complete all as specified and directed.
S&F Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLSH, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
S&F Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLSH, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLSH 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats conforming to FE 410W (Gde E-250 Quality A) complete all as specified and directed.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material.
R.K.ASSOCIATES
R K CONSTRUCTION COMPANY
Mohit Enterprises
Avion Industries
M/S KESRI WORKERS
M/S V K MEHROTRA
chauhan construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .