Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹16.9 L+₹21,170 (1.27%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹18.9 L+₹2.2 L (13.4%)Rejected-Finance 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | Rejected-Technical 112 SHIV NAGAR II MURALIPURA SIKAR ROAD JAIPUR RJ | JAIPUR | RAJASTHAN | 302001 | - | Rejected-Technical Not approved since not enlisted in cat b(i) and not upload supported similar work documents |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
10 Feb 2021, 6:00 pmClosed
CWE JAIPUR
HQ CWE JAIPUR KALYAN MARG
PROVN OF WIDENING OF ROAD (SHIFTING OF E/M AND W/S) FROM T JUNCTION OF SUPPLY DEPOT TO MH JAIPUR REAR GATE AT JAIPUR MIL STATION
2020_MES_405486_2
CWE/82033/JPR/E8
Open Tender
Miscellaneous Works
Item Rate
90 days
JAIPUR
Enlisted with MES in class E and above and category b(i)
5 documents required · 5 mandatory
₹500
Yes
GE JAIPUR
₹36,000
Yes
3 Mar 2021
28 Jan 2021
12 Feb 2021
28 Jan 2021
10 Feb 2021
28 Jan 2021
Amount
Water Supply Work
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in any type of soil etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil etc complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.50metre above the starting point etc complete all as specified and directed.
S&F tubes medium grade galvanised with all fitting and fixed in trenches of following sizes:-
(a) 15mm bore of pipe
(b) 20mm bore of pipe
(c) 25mm bore of pipe
(d) 50mm bore of pipe
(e) 80mm bore of pipe
Supplying, laying, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends with jointing materials conforming to IS 8329/2000 standard length, of K7 specification without zinc coating laid in trenches under floor, road etc of following sizes: -
(a) 100mm bore
(b) 150mm bore
M&L for sluice valves of under mentioned type, size and class with cast iron body with forged brass spindle, non rising type and cast iron wheel head, both ends flanged, IS-14846 marked complete with neoprene rubber gasket, jointing material and including nuts/bolts/washer of suitable size including taking down old sluice valve etc complete all as specified and directed of following sizes: -
(a) 80 mm bore, class PN 1.6
(b) 100 mm bore, class PN 1.6
(c) 150 mm bore, class PN 1.6
M&L for construction of valve chamber with brick masonry in CM (1:6) with 15cm thick PCC foundation in PCC (1:4:8) type D2 using 40mm graded stone aggregate, 15mm thick plaster in cm 1:6, 3mm thick MS sheet cover including 40x40x6mm MS angle iron frame fixed in PCC coping, using PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with necessary locking arrangement and painted with two coats of synthetic enamel paint over a coat of red oxide primer on all exposed surfaces including necessary excavation and earth work in any type soil including returning and filling in and ramming and removal of surplus soil up to a distance not exceeding 50 m valve pit chamber as per drawing No TD/2004/26 sheet 1/3 to 3/3 etc complete all as specified and directed of following sizes:-
900mm x 900mm x 900mm (internal dimensions)
1200mm x 1200mm x 900mm (internal dimensions)
Supply and fixing in repair MS saddle piece made out of MS flat iron 50x6mm complete with GI socket welded it on one FI strip suitably positioned at the centre of pipe complete with MS nuts, bolts, washers (02 Nos) and rubber packing for branch connection complete for following sizes of pipe: -
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
M&L for cutting of bituminous road or any type of floor for laying of pipe not exceeding 1.5 m deep including refilling/with material and watering well ramming/compacting and making good with 100mm thick PCC (1:2:4) type B-1, etc complete all as specified and directed.
M&L ductile iron fittings, IS-1538 marked Viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle/radius and straight connecting pieces, but all ends flanged, size of pipe up to 150mm bore, etc complete all as specified and directed.
Cutting of CI/DI pipes in position for insertion of new tees, branches etc of size 150mm bore etc complete all as specified and directed.
External Electrical work
M&L Sand cushioning to PVC underground cable with screened and washed sand and punning to provide a required cover. etc complete all as specified and directed.
M&L brick for protection cover to underground cable (with old sub class ‘B’ bricks) with width equal to length of brick laid dry and abutting each other with gaps between adjacent brick not exceeding 10mm etc complete all as specified and directed.
Supplying and laying un-reinforced precast cable covers class HVP, type I, with peak, size 300mm x 180mm x 40mm.etc complete all as specified and directed.
Supplying installation testing and commissioning of steel 9m,GI Octagonal pole, top dia 70mm, bottom dia 155mm,section-1 (Section length 7000mm) thick 3mm, base plate 260mmX260mmX16mm, hole in pole at a height of 300mm above the planting depth with single arm bracket 1m long with 33.7mm OD GI pipe and individual spike earthing with 8 SWG wire inclusive of civil foundation work, foundation bolt M24X750mm (4Nos) built in control box with flush cover, single arm (9 MTR) including junction box suitable inside the control box, comprising of 6A SP MCB with terminals suitable for terminating incoming and outgoing cables of upto 3.5 core 16sqmm, 1.1 KV grade armoured PVC insulated and covered cables including bolt ,nut and screws etc complete all as specified and directed.
S&F wiring with 3X1.5 Sq.mm ,600 volts grade, FRLS insulted flexible cupper conductor wire from looping junction boxes at the base of the pole to the light fittings through prelaid rigid PVC conduit as required etc complete all as specified and directed.
M&L for PCC (1:3:6) type C2, using 40 mm graded aggregate in foundations, bolt M24X750mm (4Nos) foundation of stay assembly/struts/poles etc complete as per specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate in coping including necessary form work etc complete all as specified & directed.
Dismantling and taking down carefully serviceable LED street lights any capacity or make with disconnecting the electrical connection from electric pole and refixing in the new steel 9 m GI Octagonal pole testing and commissioning etc complete all as specified & directed.
Dismantling of PCC/steel poles complete of any size type including PCC foundation and necessary excavation ,earth work making good disturbed surface etc complete all as specified & directed.
Supply, install, commissioning and testing factory made (including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type, floor mounted, compartmental and IP-54 suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper bus bars installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet with base frame 40X40X5mm angle iron, power coated, Front and rear opening type with aprons for cable entry with double door shutter including locking arrangement, PCC foundation commissioning and testing including connection of LT outdoor factory made CPRI approved complete:- (a) MCCB 4P 63 Amps 16 KA,415 volts- 1No (b) D-21 astrorex time switch-1 No (c) FP 40 Amps contractor -1No (d) MCB TP 10 Amps, C curve -1No (e) MCB 6to32 Amps SP C curve - 03 Nos (f) Reverse forward switch- 01 No (g) Toggle switch (h) Neutral link
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. Charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Supply and laying testing and commissioning connecting and testing in trenches/under floor/road/wall or passing through pipe 1100 volts grade ISI marked XLPE insulated and PVC bedded galvanised steel strips or wire armoured underground stranded aluminium conductor cable of size 16 sqmm 4 core complete all as specified & directed.
Supply and laying testing and commissioning connecting and testing in trenches/under floor/road/wall or passing through pipe 1100 volts grade ISI marked XLPE insulated and PVC bedded galvanised steel strips or wire armoured underground stranded aluminium conductor cable of size 150 sqmm 3.5 core complete all as specified & directed.
S&F galvanised steel water tubing medium grade for protection of underground cable on pole/wall under road crossing etc confirming to IS -1239 including taking out of existing GI pipes of following sizes:-
(a) 40mm bore
(b) 80mm bore
(c) 100mm bore
M&L for boring of existing road/path for laying of GI pipe upto 50mm protection for UG cable including making good disturbed area/surface etc complete all as specified and directed.
Taking out old unserviceable panel feeder pillar of different size and make etc. complete all as specified and directed.
Taking out old unserviceable LT cable of any size and make from existing LT panel to feeder pillar /bus bar chamber of different size etc. complete all as specified and directed.
Supply, install, commissioning and testing factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type, floor mounted, compartmental and IP-65 suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system, all as specified and directed, having bus bar chamber. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS Sheet and with base frame of 50x50x6mm angle iron, powder coated, having front and rear open able hinged double door shutters with aprons for cable entry and locking arrangement, PCC foundation commissioning and testing including connection of LT outdoor factory made CPRI approved complete (LTP-near Pump House No 05).
Incoming (a) ACB, manual draw out type 1250 Amp, 4 Pole, 50 KA with micro processored based release with integral over load, short circuit & earth fault & neutral protection, 50 Hz, 415 Volts grade-01 No. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 1500 Amp, 4 Pole, not less than 60cm long mounted on insulators for incoming supply complete. (c) Digital load manager multy functional energy meter having facility to measure true RMS value, KWH, neutral current for quadrant energy, max demand (KW, KVA, Kvar & Amp), CT operated 415 volts, 50 Hz AC supply including CTs -01 set. (d) Neon indicating lamps (R, Y & B) – 01 Set.
Outgoing (a) MCCB 400 Amps,4 Pole,36KA (lcu=100% lcs),with adjustable thermal over load release with earth fault protection,50Hz,415 Volts grade: 03 Nos. (b) MCCB 250 Amps,4 Pole, 36KA (lcu=100% lcs),with adjustable thermal over load release with earth fault protection,50Hz,415 Volts grade:05 Nos. (c) MCCB 63 Amps, 4 Pole, 25 KA with adjustable thermal over load release with earth fault protection, 50 Hz, 415 Volts grade – 01 No. (d) Time switch Astrorex D21-01 No. (e) DP Contactor 40 Amp-01 No. (f) Aux change over switch SP 6 Amp – 01 No. (g) MCB DP ‘C’ curve 40 Amp – 01 No. (h) MCB SP ‘C’ curve 20 Amp – 01 No. (j) MCB DP ‘C’ curve 63 Amp – 01 No.
Dismantling/taking down old LT Panel complete and disconnecting the electrical connection carefully to serviceable ACB and MCCBs of any size and capacity including PCC foundation and necessary excavation, earth work making good disturbed surface all as directed by Engineer-in-Charge. Note:- ACB and MCCB retrieved from above item shall be deposit to E/M yard by contractor.
M&L for cable, jointing kit, 1.1 KV grade, heat shrinkable, straight through type complete with jointing material suitable for 3.5/4 core XLPE ,armoured, aluminium conductor etc complete all as specified and directed of following sizes:
(a) 25 to 50 sq.mm 3.5 core
(b) 70 to 95 sq.mm 3.5 core
(c) 120 to 150 sq.mm 3.5 core
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 600mmx600mmx6mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. NOTE:- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire. (iii) Quoted shall include cost of 7.5 metre earth lead wire. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Supply, laying, testing and commissioning of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 185 sq mm.
M&L for cable end termination, jointing kit, 11 KV grade, heat shrinkable, indoor type complete with jointing material suitable for XLPE cable 3 core 11 KV grade etc complete all as specified and directed of sizes 150 to 185 Sq.mm x 3 core.
M&L for cable end termination, jointing kit, 11 KV grade, cold shrinkable, straight through type complete with jointing material suitable for XLPE cable 3 core 11 KV grade etc complete all as specified and directed of sizes 150 to 185 Sq.mm x 3 core.
S&F new one copper strip 20X3mm with saddles and fixing screws etc for roof conductors and down conductors above ground etc complete all as specified & directed.
S&F HT/LT cable/route indicator cast iron of suitable size along HT cable trenches including planting in ground with PCC etc complete all as specified & directed.
Schedule of Credit
SHREE BHAGWATI ENTERPRISES
DIVYA ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .