Tender Value
₹23.7 L
EMD Value
₹23,730
Closing Date
19 Feb 2022, 6:00 pmClosed
RE Electrical RHB
Resident Engineer Division Electrical Rajasthan Housing Board Jyoti Nagar Jaipur
Repair and Annual maintenance of 33 0.4 KV GSS and DG Sets in Gomti Apartment Sector 18 Pratap Nagar RHB Jaipur
2022_RHBCE_258118_1
RE-Electrical_03/2021-22
Open Tender
Electrical Works
Percentage
365 days
Jaipur
As per NIT
2 documents required · 2 mandatory
₹1,180
As per NIT
₹23,730
Yes
23 Feb 2022
8 Feb 2022
22 Feb 2022
8 Feb 2022
19 Feb 2022
8 Feb 2022
Amount
(PART 'B) Replacement Work
Safety & measurement Equipments
Rubber Hand Gloves
Safety Belts
Safety Helmets
Transformer oil for toping in consevator tank of 1600 KVA,33/0.433 KV (2 Sets)
Replacement of following faulty items/ cnsumable items of DG Sets
Oil Filter of 75/80 KVA DG Sets
Diesel filter of 75/80 KVA DG Sets
Lubricant OIL
180 AH Lead acid battery
RYB Indicator
Diesel Pipe
Canopy Lock
DG Panel Relay
RPM Meter
Fuel Strainer
Stop Solenoid
Fan Belt
Fuel injection pump repair
coolent
Diesel
4pole 130 amp contractor with NO/NC
CSENEX-I 101-S-D-C-H 110 V DC Relay
JRV 161 A/B/C 110 V DC Auxiliary Relay
Transformer panel annunciator 24 Windows
Refilling of fire fighting cylinder ABC Powder Type 4 KG
Refilling of fire fighting cylinder CO2 Type 4.5 KG (3 Nos cylinder)
Replacement of E/F and over current relay suitable for 33 KV 1600 KVA Transformer Panel and feeder Panel
Replacement of spring charging motor of 33 KV VCB
Replacement of Burnt wiring of TRF Panels feeder panels and Amf Panels with suitable size PVC insulated copper conductor
Calibration of meters,and CT/PT SET CT Ratio 240A-120A-60A/5A-5A PT Ratio 33KV /110V
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz ±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced
LED Street Light fixture 70 Watt
(Part C)
I st Time Operation and Maintenance Work GSS
Labour charges for over all inspection of sub station with two transformer for job requiring works analysis and testing of dielectric strength of oil ,insulation resistance valve and earth resistivity etc.
Labour charges for opening the transformer tank top cover after removing required accessories , including all T&P up to 5 MVA Transformer
Preventing oil leakage by changing main gasket with material after removing cover up to 1.6 MVA Transformer
Change of HV /LV bushing gasket ring and rubber washers including supply of required material & draining /refilling of oil as required
Change of gaskets of valves/ radiator/ Buchhloze,s Relay including cost of gaskets etc.
Valves/Buchhloze,s Relay
Radiator Valves
Dehydration/filteration and reconditioing of transformer oil
Cleaningof oil scale deposits over the body and radiators of power transformerwith thinner/detergentand de-rustingup to 1.6 MVA Transformer
Checking ,tightening & replacement of jumpers,clamps connectors of bus bar including transformer &equipments of sub station
33/11 KV S/S with 2 Nos.Power transformer
Replacement of damaged bus bar conductor in cluding re jumpering etc.
Bus bar with ACSR Panther
Replacement of damaged Pin Post insulators including re binding and jumpering etc.
33 KV PIN/POST Insulator
Replacement of damaged Disc insulators with hardware including re binding and jumpering etc.
on 33 kv side
Replacement of damaged jumpersincluding fixing PG clamps T Clamps and connectors both side proper tighting of MS Nuts and bolts
ACSR Panther
Replacement of33/11 KV Lighting arrestors including jumperigs and earth connections etc
Repair and maintenace of 33/11 KV isolator/GO Switch
33 KV Isolator/GO Switch
Removing of unwanted grass/small plants from the33/11 kv sub station ( 2 times)
from gravelled land
General Maintenance charge of DG Sets
II nd Time Operation and Maintenance Work GSS
Labour charges for over all inspection of sub station with two transformer for job requiring works analysis and testing of dielectric strength of oil ,insulation resistance valve and earth resistivity etc.
Labour charges for opening the transformer tank top cover after removing required accessories , including all T&P up to 5 MVA Transformer
Preventing oil leakage by changing main gasket with material after removing cover up to 1.6 MVA Transformer
Change of HV /LV bushing gasket ring and rubber washers including supply of required material & draining /refilling of oil as required
Change of gaskets of valves/ radiator/ Buchhloze,s Relay including cost of gaskets etc.
Valves/Buchhloze,s Relay
Radiator Valves
Dehydration/filteration and reconditioing of transformer oil
Cleaningof oil scale deposits over the body and radiators of power transformerwith thinner/detergentand de-rustingup to 1.6 MVA Transformer
Checking ,tightening & replacement of jumpers,clamps connectors of bus bar including transformer &equipments of sub station
33/11 KV S/S with 2 Nos.Power transformer
Replacement of damaged bus bar conductor in cluding re jumpering etc.
Bus bar with ACSR Panther
Replacement of damaged Pin Post insulators including re binding and jumpering etc.
33 KV PIN/POST Insulator
Replacement of damaged Disc insulators with hardware including re binding and jumpering etc.
on 33 kv side
Replacement of damaged jumpersincluding fixing PG clamps T Clamps and connectors both side proper tighting of MS Nuts and bolts
ACSR Panther
Replacement of33/11 KV Lighting arrestors including jumperigs and earth connections etc
Repair and maintenace of 33/11 KV isolator/GO Switch
33 KV Isolator/GO Switch
Removing of unwanted grass/small plants from the33/11 kv sub station ( 2 times)
from gravelled land
General Maintenance charge of DG Sets
(Part D) Annual operation of GSS
Providing one number skilled manpower in one shift of 8 hours on all days including Sunday and holiday
Ist year
Providing one number semi skilled manpower in one shift of 8 hours on all days including Sunday and holiday
Bidder Name
Amount
ASHISH ELECTRICALS(GSTN-08AHXPC7032J1ZZ)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .