Executive Engineer, Electrical Division, M.C., Chd
Executive Engineer, Electrical Division, M.C., Chd
Providing and fixing of new lights in place of old, missing non Led garden street light in Sector- 18, 19 and 21 Chandigarh. (Ward No. 11)
2026_MCC_95282_1
172/E/MCC/2026
Open Tender
Electrical Works
Percentage
90 days
Providing and fixing of new lights in place of old
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹22,745
21 Sept 2026
9 Sept 2026
17 Sept 2026
9 Sept 2026
17 Sept 2026
9 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | RCC Pole Bracket: S/E of 32mm dia x 2m long G.I. Pipe (Medium Class) Pole Arm/ Bracket for mounting LED Street Lighting/ Fitting on pole cement/tubular including bending the pipe of the required shape (90 to 105 deg), 2 nos. required size (suitable for cemented and circular pole) Flat Iron Clamps with Nut, Bolts and Washer. GI Coating/ Painting the flat iron with primer and finish paint as per relevant tender specifications or other material required to fix the bracket and work must be completed to the entire satisfaction of Engineer-in-charge. The bracket is to be fixed on RCC/ Steel Tubular Pole with the help of M.S. Clamps including welding and drilling of holes and complete in all respect including labour and other petty items required to complete the job upto the entire satisfaction of the Engineer-in-Charge.The Make of the G.I. pipe should be of Tata/ Jindal/ Hissar or Ravindra. | 13 | Nos. | 900 | ₹11,700 |
| 2 | Supply and Erection of 2.5” dia. G.I. Pipe pole 4.5 Mtrs long.
Supply, Fabrication & Erection of 2.5” dia G.I. pipe pole having length 4.5 long, B class (medium) Jindal/ Tata/ Birla make ISI marked. The pole shall be erected 3’ below ground level in 8” dia. RCC muff ready made. The gap between the pole and muff shall be filled with cement concrete in ratio of 1:2:4 and making required no. of holes in the pole including carriage of pole to the site of work including all labour and material required to complete the job including suitable size of nipple welded with the pipe. Material to be (Jindal, Hissar or better brand Only). The cost includes a plinth of cement concrete of 12”x12” size and 2” thick. The work shall be executed to the entire satisfaction of Engineer-in-Charge. | 25 | Nos. | 3,144 | ₹78,600 |
| 3 | Wall Bracket: S/E of 32mm dia x 1m long G.I. Pipe (Medium Class) Pole Arm/ Bracket for mounting LED Street Lighting/Fitting on pole including bending the pipe of the required shape (90 to 105 deg), 2 nos. required size (suitable for cemented and circular pole) Flat Iron Clamps with Nut, Bolts and Washer. G.I. Coating/ Painting the flat iron with primer and finish paint as per relevant tender specifications or other material required to fix the bracket and work must be completed to the entire satisfaction of Engineer-in-charge. The bracket is to be fixed on wall with the help of M.S. Clamps including welding and drilling of holes and complete in all respect including labour and other petty items required to complete the job upto the entire satisfaction of the Engineer-in-Charge.The Make of the G.I. pipe should be of Tata/ Jindal/ Hissar or Ravindra. | 2 | Nos. | 532 | ₹1,064 |
| 4 | S/E of CC Collars including following:-
a) The box shall be enclosed in a cement collar made from cement concrete 1:2:4 with outside dia 16”.
b) The collar shall be embedded in the group upto 6” shall stand 9” above ground shall have housed 12” high SMC Box and 6” top over the box.
c) The collar shall be provided with 2 G.I. Pipe of 40mm dia and 45cm long to facilitate entry of cables in the junction box after digg out the cable loops from earth complete in all respects, connections etc.
d) The collar shall be plastered properly finished, curing and painted with 2 coats of Apex paint of superior quality.
e) Providing and Fixing junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement. The existing ckt cable loops be made properly connection after digging from the earth and refilling the same position. There should be a terminal Strip (Thimble type) 30 amp, one no. Kitkat, rating suitable for minimum 4x16 sq.mm aluminum cable termination. The sheath of the armoured cable should be properly thimbed with the pole for proper earthing. Curing of CC Collar must be done as per satisfaction of Engineer-in-charge. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect. | 56 | Nos. | 2,352 | ₹1,31,712 |
| 5 | Dismantling of existing damaged/broken old bollard lights/CC Collar, Jallies alongwith junction box, wire and C.C. foundation etc. and other material complete in all respect to the satisfaction of Engg-in-charge. The entire “malba” shall be disposed off and send to C & D plant Industrial Area Phase-I.The contractor shall hand over the dismantled material to the J.E-in-Charge at central store in proper form duly accounted or the same may be considered as recovery/ buyback as per conditions of DNIT. | 27 | Nos. | 219 | ₹5,913 |
| 6 | Minor Repair of Cemented Bollard/ CC Collar: Minor Repair of Cemented Bollard/ CC Collar and all the necessary items for repair i.e. sand and cement and curing of CC Collar after repair complete in all respects to the entire satisfaction of Engineer-in-Charge. | 10 | Nos. | 393 | ₹3,930 |
| 7 | PAINTING & NUMBERING OF POLES 7.5/9 MTR. LONG:- (With Snowcem)
Painting of poles above ground level with two coats of Silver paint of Nerolec/ Asian/ ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/ rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. The Cement collar around the pole should be painted with two coats of good quality White colour snowcem. The Danger sign's shall be written on each pole on it's two sides with red paint on yellow base to be show to warning about hazard as threats which are essential to safety for General Public. The work shall be completed to the to the entire satisfaction of Engineer-in-charge. | 5 | Nos. | 583 | ₹2,915 |
| 8 | PAINTING & NUMBERING OF POLES 4.5/6 MTR. LONG:- (With Snowcem)
Painting of poles above ground level with two coats of Silver/Green paint of Nerolec/ Asian/ ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/ rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. The Cement collar around the pole should be painted with two coats of good quality White colour snowcem. The Danger sign's shall be written on each pole on it's two sides with red paint on yellow base to be show to warning about hazard as threats which are essential to safety for General Public. The work shall be completed to the to the entire satisfaction of Engineer-in-charge. | 25 | Nos. | 361 | ₹9,025 |
| 9 | S&E of Outdoor type both side with L-key lock arrangement openable M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mm x 100mm x 6mm thick at the bottom of the legs. The front side and the back side of the pedestal should be openable with hinged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx 6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. Four No. supporting members each of size 50mm x 6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN, BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. One No. The legs of the pedestal shall be embedded in the 1:2:4 C.C. mixture by digging 1' deep pit of 1' dia. The letter 'M.C.C.' in 4" size shall be written on the front door of the Pedestal. The job also included supply and erection one no. wooden plank/ board of size 1’-6’’ x 1’-6’’ and 25mm thick suitable for fixing energy mater including cost of screw, nuts and bolts in cubical pedestal complete in all respect. The pedestal will be housed on RCC foundation, Snowcem and platform of size 900mm deep (450mm underground and 450 mm above ground x 960 mm long x 410 mm wide including sufficient number of DWC pipe size of 51/63mm pieces to facility to entire the main cable and the circuit cable. The work shall be executed to the entire satisfaction of Engineer-in-Charge. | 5 | Nos. | 20,204 | ₹1,01,020 |
| 10 | Supply & Erection of Three Phase Automatic Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons/ L&T/ Schenider or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-
1. It shall have 3 contactors of capacity 40 Amp. each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage.
2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet for its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS. | 8 | Nos. | 16,487 | ₹1,31,896 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
BOQ_117025.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .