Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Awarded being L1 bidder | |
| 2 | L2₹33.0 L+₹99,700 (3.12%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 bidder | |
| 3 | L3₹34.7 L+₹2.7 L (8.38%)Rejected-Finance INDEX NO B 33 NC R O KRALPORA DISTT BUDGAM SRINAGAR J K 190019 | SRINAGAR | BUDGAM | JAMMU AND KASHMIR | 190019 | L3 | Rejected-Finance Rejected being L3 bidder | |
| 4 | L4₹35.8 L+₹3.8 L (11.9%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L4 | Rejected-Finance Rejected being L4 bidder | |
| 5 | L5₹36.8 L+₹4.8 L (15.0%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L5 | Rejected-Finance Rejected being L5 bidder |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
20 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS, C/O 56 APO, PIN- 914133
CA NO. CWEK/TOKEN-72/969 EWS/2024-25- PROVN OF 1X250 KVA AND TRAILER MOUNTED 01X400 KVA TRANSFORMER WITH ALLIED INFRA AT VARIOUS LOCATION UNDER GE 969 EWS, AND JOB NO- i, XII/01/LBCW/STN HQ URI/ 2024-25) AND ii. ALBW/04/2024-25/HAWS,GULMARG
2024_MES_678316_1
CWEK/TOKEN-72/969 EWS/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 969 EWS
Class D and above and
category b ii
7 documents required · 7 mandatory
₹500
GE 969 EWS
₹75,000
HQ 133 WORKS ENGRS
16 Dec 2024
7 Oct 2024
28 Nov 2024
7 Oct 2024
20 Nov 2024
25 Oct 2024
7 Oct 2024 - 14 Oct 2024
15 Oct 2024
Amount
Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sq mm 3.5 core all as specified.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts earthed grade , of size 3 core 120 sq mm.
Supply, Installation, Commissioning of transformer of capacity 250 KVA step down outdoor type Copper Wounded ONAN Cooling 11/0.433 KV (at no load) AC 3 Phase 50 Hz on secondary side double wounded oil immersed naturally all air cooled with external tubes/radiator, delta connected as on primary and star connected with neutral brought on secondary side and having tapping at (+) 25%. (+) 5%, (+) 7.5% to be changed by hand operated OFF LOAD top changing gear. The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/LV winding when measured by the resistance method after continuous full load run in ambient temprature the transformer snall confirming to IS 2026, 1997 and comprising of following accessories:- (a) 01 No Cable end box on HV side consisting of with 03 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3 Core 120 Sqmm including cable joint complete adopter box.
(b) 01 No cable end box on LV secondary side consisting of 04 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3.5 Core 185 Sqmm including catile joint complete adopter box. (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first filling of dehydrating agent (e) Explosive vent (f) Thermometer Pocket (g) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI Strip. (h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with. maximum temprature indicator and re-setting device to maximum temprature including needle of temprature gauge max reading panted terminal (j) Rating plate with terminal plate (k) Oil drain filter valve (l) Oil filling hole on top cover with plug (m) Air release valve/plug (n) 4 Nos plain solid cast steel detachable rollers (o) Extra bushing for neutral out side the cable box providing independent earthing for neutral (p) First fill of transformer oil confirming to relevant IS and tested upto 60KV dielectric strength.
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 15 m below normal ground level connected to galvanized earth strip 32x6mm (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I Including necessary excavation and earth work in any type of soil PCC 13:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funne, 20 mm dia light grade for protection of earth electrode, 20 mm dia Gi pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion Note The rate sinclusive of necessary earth work, RFR and removal etc, all as specified and directed by Engineer-in-Charge.
M&L for Switch air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps 11000 volts (12 Insulator) alongwith fuse systern complete all as specified and directed.
Supply & fixing Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metre long) including drilling of necessary holes, & painting complete all as specified. Note:- (i) Cost of painting & numbering on poles i.e, making five no alternative white & black strips 30 cm height each (upto 1.50 metre height from top of PCC coping & numbering to the poles with synthetic enamel paint etc shall be deemed to be included in the rates of above items (ii) Earthwork, PCC foundation & coping shall be measured and paid separately under respective item of Schedule
M&L for Lighting arresters expulsion type complete with all fittings transmission class, discharge capacity 65KA suitable for 11000 volts all as specified.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm all as specified.
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth Wire 4.0 mm (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1.3:6 type C1 chamber with RCC 12:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note The rate is iinclusive of necessary earth work, RFR and removal etc all as specified and as directed by Engineer-in-Charge.
Supply, install, testing and commissioning of CPRI approved factory made LT feeder piller box outdoor type made out of 3.15 mm thick CRCA sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, cubical type, front and rear side openable, compartment type with hinged door ligting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 400 amps rated aluminium bus bar having 1100 volts grade sleaving and internal connection should be provided with aluminium strips of suitable size and to accommodate and including the following MCCBS duly painted with 2 coats powder coating over a coat of anticorrosive red oxide primer should accomodate the following accessories
Construction of transformer shed for transformer (2.9 M (L) x 2.4 M (B) x 3.40M (H) complete all as specified and show on Drg No CESZ/TD-1110/2011 Sheet 1/1 and 2/2 dated 01.12.11 all as specified.
S & F cross arms pracing supports, clamps and back plate fabricated from structural steel sections including nuts bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome, one under coat and one finishing coat of aluminum paint all as specified
Excavation in trenches n exc 1.5m wide and nexc 15m depth for foundation, laying of cables etc. and getting out in hard and dense soil complete all as specified
Returning, filling in, including spreading evelling, watering and well ramming in layers not exc 25 cm depth in soil all as specified.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level n exc, where directed at a level n exc. complete all as specified
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed Note The punned down thickness shall only be measured
M&L for plain well burnt as class 'B' bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as speified and directed by Engr-in- charge
M & L for plain cement concrete1:4:8 type D2 (using 40 mm graded stone aggregate for foundation fillings and mass conctere complete all as specified and directed.
M & L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) for mass fillings of poles, concterecomplete all as specified and directed.
Material and labour of danger notice plate of 16 mm thick as per IS 2551 of 1982 mild steel sheets vitreous enamelled white with letters figures and conventional skuil and bones in signal red colour and inclusive fixed with MS flat clamps 25x3mm 2Nos bolts, and nuts for HT 11KV 25x20cm all as specified.
M & L anti-climbing device: spikes type fabricated cut of M. S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole all as specified.
Supply and laying Gl pipe 80 mm bore light grade with fitting for cable protection at road crossing/under concrete all as specified.
M & L PCC 1:2:4 type B (using 20 mm graded gush stone aggregate), casting in cube of size required size at site by using necessary form work for coping of poles all as specified.
M&L for test point terminal block made of gun metal or phoshorus bonze size 75x75x25mm, dilled and screwed including 4 Nos 8mm dia 25min long hexagonal head screwes fixed on wall surface making connections of down earth conductors and earthing strips all as specifed and directed.
Supply installation, testing and commissioning outdoor type stepdown transformer, 11 KV, 415 volts (at full load) AC 3 phase 50 HZ 400 KVA capacity, core type, double copper wound, Oil immersed, naturally cooled oil Natural Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN- 11 with neutral brought out on secondary side (LV side) and having taping at ±25% & ±5% on HV side to be charged by means of hands operated off load tap changer gear The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measurement by resistance method after continous full load run on an ambient temp of 40 degree celsius. The transformer shall be IS-1180 marked Complete all as specified and directed by Engr-in-charge with the following standard fittings/accessories
(a) One cable box on LT side (Secondary side) consisting of four No's procelain with copper bushing rods complete with nuts and washers with one No cable gland suitable for reception of taking out 01 No 35 core LT 1100 Volts grade, PVC insulated heavy armoured cable including gland join and jointing materials complete (b) Oil Conservator with filter type drain valve and oil level gauge (c) Dehydrating breather first fill dehydrating agent (Silica Gel) (d) Explosive vent (e) Thermometer pocket on tank cover. (f) One No 100mm dia type thermometer vapour pressure type having range (0-120) degree Clesius with metal guard having maximum temperature indication with res sting device for transformer (g) Ring plate and terminal marking plate (h)Oil level Gauge (j) Oil drain filter valve (k) Lifting Lugs (l) Oil filling hole with cap/plug wit connection plate complete (m) Air release valve/plug (n) Four Nos Plain solid cast steel detachable rollers (o) Extra bushing for neutral outside the cable box providing independent earthing for neutral (p) First fil of fresh transformer of confirming to mounting IS tested upto 40 KV dielectric strength at 2.5 mm gap
(a) Loading platform height-1200mm approx from the ground (b) Ground clearance 1000MM (c) No of axles lines-2Nos (d) Types of wheels with flanges for movement of the rail (e) No of wheels - 04 Nos (f) wheel pitch = 2500mm Approx Rail system: Two parallel rails should be welded on ground channels in such a way that top surface of rails are the bolt to the floor level The two parallel channel (SMC 200 as per IS 808) embedded to the four to the floor with their neutral axes separated by a distance of 2500mm.
Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core all as specified.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade. of size 3 core 95 sq mm alongwith suitable lugs for input in LT Panel MCCBS
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 sqmim to 95 sqmm all as specified.
Supply and fix cable end jointing kit for 1 KV grade cable for end joint complete with Jointing material heat Shrink type and accessories suitable for 3.5/4 core XLPE armoured, Al conductor cable of size 300 sqmm, Indoor/Outdoor type
Rajindera Enterprises (BID ID -3159399)
G N Constructions (BID ID -3170129)
VEDA INFRASTRUCTURE (BID ID -3170321)
M/S Sky Engineers (BID ID -3157991)
M/S KULBIR SINGH SODHI AND CO (BID ID -3159230)
M/s Habib Electronics (BID ID -3153784)
Electromech Engineers (BID ID -3158501)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .