Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | ₹8.8 L Quoted ₹7.3 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹8.0 LRejected-AOC | ₹8.0 L | L2 | Rejected-AOC REJECTED |
| 3 | L3₹8.1 LRejected-AOC | ₹8.1 L | L3 | Rejected-AOC REJECTED |
| 4 | L4₹8.4 LRejected-AOC | ₹8.4 L | L4 | Rejected-AOC REJECTED |
| 5 | L5₹9.2 LRejected-AOC | ₹9.2 L | L5 | Rejected-AOC REJECTED |
Tender Value
₹9.4 L
EMD Value
₹10,000
Closing Date
14 Jan 2026, 5:00 pmClosed
EXECUTIVE ENGINEER B AND C ZILLA PARISHAD SANGLI
EXECUTIVE ENGINEER B AND C ZILLA PARISHAD SANGLI
23 Repairs to Z.P.School Ashta No.13 Tal Walwa
2026_SANGL_1266529_23
33/2025-2026
Open Tender
Civil Works
120 days
Ashta Tal Walwa
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹10,000
7 May 2026
6 Jan 2026
19 Jan 2026
6 Jan 2026
14 Jan 2026
6 Jan 2026
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and Fixing matt finish stainless steel of 302 grade railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter excetra complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor) Item / Page No : 8 / 265 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 34 / 216 Specification No : Bd.M.3 B Spec. Page No : 380 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to corrosponding Indian standared for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 25 / 215 Specification No : Bd.M.13 Spec. Page No : 386 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.)with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 10 / 176 Specification No : Bd.E.4, B-7 Spec. Page No : 289-290, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fiber glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 square metre per kilogram with two coats Using approved chemicals for masonry and concrete surface by brush, covering seven years gaurantee on stamp paper, excetra complete. (For Ground Floor) Item / Page No : 9 / 206 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and fixing Orissa type white glazed earrthenware 575 milimetre water closet pan including "S" trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall, 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories excetra complete. (For Ground Floor) Item / Page No : 30 / 277 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 2 / 264 Specification No : Bd.U.1 Spec. Page No : 537
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor) Item / Page No : 9 / 246 Specification No : Bd.T.34 Spec. Page No : 499
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 2 / 153 Specification No : Bd.A.1 Spec. Page No : 259
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 6 / 153 Specification No : Bd.A.2 Spec. Page No : 259
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 11 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 25 / 225 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface (excluding the primer coat), excetra complete. (For Ground Floor) Item / Page No : 12 / 227 Specification No : Bd.P.6 Spec. Page No : 414
Providing and laying cast in situ / Ready Mix cement concrete in M-15 of trap / granite / quartzite / gneiss metal for coping to plinth or parapet moulded or chamfered as per drawing or as directed including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra complete. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 16 / 177 Specification No : Bd.E.3, Spec. Page No : 288-289 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade, excetra complete. Weight 18 to 20 kilogram per Square metre. (For Ground Floor) Item / Page No : 9 / 174 Specification No : Bd.W.6 Spec. Page No : 585-586
Providing and fixing heavy duty inter locking concrete rubber mould glossy paving blocks of 80 milimetre thickness of having a strength of 400 kilogramme per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning, excetra complete.(using 100 percent crushed sand) Item / Page No : 54 / 219 Specification No : Bd.M Spec. Page No : --- Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 8 / 176 Specification No : Bd.E.4, B-7 Spec. Page No : 289-290, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 8.24 MB
Tendernotice_2.pdf
PDF • 1.54 MB
BOQ_2182006.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid