| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹33.0 L+₹3.2 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L4₹33.3 L+₹3.6 L (12.1%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L4 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹42.1 L+₹12.4 L (41.6%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | Rejected-Technical HOUSE NO 02B 2266 SHIVAJI NAGAR DELHI ROAD SAHARANPUR UTTAR PRADESH 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | - | Rejected-Technical Firm not admitted being not enlisted in appropriate categories. |
| Sl No | Description | Qty | Unit | PANWAR CONSTRUCTIONS L4 | HARI SINGH CONTRACTOR L1 | M/S GURENDER SINGH L2 | SUBHASH CHAND CONTRACTOR L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Deployment of T&P and Labour for Cutting/trimming of grass/ shrub/ weeds/ bushes/ vegetation growth etc at ground level including removal of small undulations in natural ground, stacking of spoil into heaps removing surplus spoil to a distance exceeding 50 metres and not exceeding 100 metres and depositing at a place complete all as specified and directed.
Note: The rate quoted by tenderer is deemed to included in item for cutting of grass by manual labour or by bush cutter (incl POL) operated by trained operator as required & directed. | 97,000 | 10 Sqm | 8 ₹7,76,000 | 4 ₹3,88,000 Lowest | 7 ₹6,79,000 | 6 ₹5,82,000 |
| 2.00 | Deployment of T&P and Labour for Cutting of grass grass/ shrub/ weeds/ bushes/ vegetation growth etc from shoulders of runway and from parallel taxi track by jungle jim/Harrow driven by tractor operated by trained operator by providing tractor and jungle jim/Harrow including POL complete all as specified and directed.
Note: Any break down of tractor and jungle jim harrow or tractor shall be made good by contractor without any extra cost to the Govt. | 90,500 | 100 Sqm | 8 ₹7,24,000 | 4 ₹3,62,000 Lowest | 7 ₹6,33,500 | 6 ₹5,43,000 |
| 3.00 | M & L for cleaning of storm water drains, inside/outside cleaning by rough excavation not exceeding 1.5 M deep and getting out in soft/loose soil including cleaning away all grass vegetation, saplings, shrubs bush wood of under growth roots removing excavated material and obtained from cleaning to a distance not exceeding 50 Meter from outside the periphery of the area under clearance depsoiting the same in low laying area complete all as specified and directed. | 1,188 | Cum | 200 ₹2,37,600 | 180 ₹2,13,840 | 90 ₹1,06,920 | 70 ₹83,160 Lowest |
| 4.00 | Demolition of brick work built in cement mortor including all quoins dismantling, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. | 12 | Cum | 800 ₹9,600 | 1,200 ₹14,400 | 200 ₹2,400 Lowest | 200 ₹2,400 Lowest |
| 5.00 | M & L for brick work with sub class `B' bricks old size in cement mortar (1:6) straight or curved on plan exceeding 6m mean redius etc complete all as specified and directed. | 12 | Cum | 4,200 ₹50,400 | 3,800 ₹45,600 | 3,200 ₹38,400 | 2,500 ₹30,000 Lowest |
| 6.00 | Taking down Cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. | 340 | Sqm | 15 ₹5,100 | 70 ₹23,800 | 10 ₹3,400 Lowest | 10 ₹3,400 Lowest |
| 7.00 | M & L for rendering 15mm thick on fair faces of brick work or concrete inner surfaces of drain in cement mortar (1:4) and finished the surfaces fair and even smooth without using extra cement complete all as specified and directed. | 440 | Sqm | 200 ₹88,000 | 180 ₹79,200 | 135 ₹59,400 | 115 ₹50,600 Lowest |
| 8.00 | M & L for PCC Type C2 (1:3:6) (using 40 mm graded aggregate) Cement concrete in foundations, filling and mass-concrete complete all as specified and directed. | 15.75 | Cum | 3,500 ₹55,125 | 2,800 ₹44,100 | 3,500 ₹55,125 | 2,600 ₹40,950 Lowest |
| 9.00 | M & L for PCC (1:2:4) type B-1 (using 20 mm gradded stone aggregates) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings, parapets copings, water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and directed. | 2 | Cum | 5,500 ₹11,000 | 6,900 ₹13,800 | 5,000 ₹10,000 | 4,000 ₹8,000 Lowest |
| 10.00 | Demolition of cement concrete (un-renforced) in ground floor and paving. exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as specified and directed. | 24.75 | Cum | 700 ₹17,325 | 900 ₹22,275 | 250 ₹6,187.5 | 100 ₹2,475 Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
11 Oct 2025, 6:00 pmClosed
SHRI PRASANTA KACHARI GE (AF) SARSAWA
SHRI PRASANTA KACHARI GE (AF) SARSAWA
REPAIR/CLEANING OF MONSOON DRAIN AND BRICK MASONARY, COPING, PLASTERING, GRASS CUTTING AND MISC ITEMS OF AIRFIELD AREA AND REPAIR/MAINT TO E/M INSTALLATION AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2025_MES_730787_1
8125/SAR-T-49/2025-26
Open Tender
Civil Works
Item Rate
330 days
GE(AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹96,000
Yes
9 Dec 2025
13 Sept 2025
18 Oct 2025
13 Sept 2025
11 Oct 2025
27 Sept 2025
13 Sept 2025 - 27 Sept 2025
Amount
Deployment of T&P and Labour for Cutting/trimming of grass/ shrub/ weeds/ bushes/ vegetation growth etc at ground level including removal of small undulations in natural ground, stacking of spoil into heaps removing surplus spoil to a distance exceeding 50 metres and not exceeding 100 metres and depositing at a place complete all as specified and directed. Note: The rate quoted by tenderer is deemed to included in item for cutting of grass by manual labour or by bush cutter (incl POL) operated by trained operator as required & directed.
Deployment of T&P and Labour for Cutting of grass grass/ shrub/ weeds/ bushes/ vegetation growth etc from shoulders of runway and from parallel taxi track by jungle jim/Harrow driven by tractor operated by trained operator by providing tractor and jungle jim/Harrow including POL complete all as specified and directed. Note: Any break down of tractor and jungle jim harrow or tractor shall be made good by contractor without any extra cost to the Govt.
M & L for cleaning of storm water drains, inside/outside cleaning by rough excavation not exceeding 1.5 M deep and getting out in soft/loose soil including cleaning away all grass vegetation, saplings, shrubs bush wood of under growth roots removing excavated material and obtained from cleaning to a distance not exceeding 50 Meter from outside the periphery of the area under clearance depsoiting the same in low laying area complete all as specified and directed.
Demolition of brick work built in cement mortor including all quoins dismantling, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M & L for brick work with sub class `B' bricks old size in cement mortar (1:6) straight or curved on plan exceeding 6m mean redius etc complete all as specified and directed.
Taking down Cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L for rendering 15mm thick on fair faces of brick work or concrete inner surfaces of drain in cement mortar (1:4) and finished the surfaces fair and even smooth without using extra cement complete all as specified and directed.
M & L for PCC Type C2 (1:3:6) (using 40 mm graded aggregate) Cement concrete in foundations, filling and mass-concrete complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 (using 20 mm gradded stone aggregates) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings, parapets copings, water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and directed.
Demolition of cement concrete (un-renforced) in ground floor and paving. exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as specified and directed.
M & L for 75 mm thick PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M & L for 75mm thick PCC Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in flooring & alternate panel with filling bitumen etc. including necessary form work complete all as specified and directed. Note:- (i) Rate for joint filling with Bitumen, with 80/25 bitumen and coarse sand mortar (1:3) shall be included in quoted rate. (ii) Size of pannel will be 2.5mx2.5m all as directed by Engr-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixturesand making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed.
M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan/exhaust point controlled by one way switch
All as per Item No 14.00 here-in-above but for one 5 Amp socket outlet on independent board complete all as specified and directed.
All as per Item No 14.00 here-in-above but for one 5 Amp socket outlet on same board complete all as specified and directed.
All as per above Item No 16.00 here-in-before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed.
S & F switch piano type 5 amp one way ISI Marked complete all as specified and directed.
S & F switch piano type15 Amps one way ISI Marked complete all as specified and directed.
S & F socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S & F socket outlet 2-in-1, 6 pin 5 amp and 15 amps all as specified and directed.
S & F electronic fan regulator step type and flugh type complete all as specified and directed.
S & F ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and directed.
S & F Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified directed.
S & F sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) New conduit/ casing- caping and accessories shall be measured separately. (ii) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor shall be a unit length.
S & F in replacement sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn into existing / new conduit of any size and type / casing-caping with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor shall be a unit length.
S & F in replacement of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule Pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
All as per Item No 27.00 here-in-above but using GI strip of size 32 x 6 mm as earthing lead complete all as specified and directed.
M & L in repair for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall complete all as specified and directed.
S & F in replacment of environment friendly indoor decorative 20 watt LED polycarbonate batten with opal difusse, operating voltage range 140V to 270V, driver effieciency 88%, lume efficiency = 100 Im/watt, THD < 20 CRI> 80, colour tempreture 6500 K, inbuolt surge protection = 2.5Kv, isolation 3.75 and with zero mercury content incl all accessories complete all as specified and directed.
M & L for taking out brunt coils of ceiling fan in replacement of all coils of ceiling fan motor AC 230 volts, of 1200/1400 mm with super enamel copper winding of proper guage weight etc (having same nos of turns) winding using insulating materials varnishing, heating, baking, replacment of bearing, bush, shafts etc re-assembling the fan after making it functional and testing, maintain the speed of fan complete all as specified and directed.
All as per Item No 31.00 here-in-above but exhaust fan upto size of 450mm sweep complete all as specified and directed.
S & F in replacment of unsv display board for showing details of E/M installation as provided made out of PVC sheet of size 1.5 mtr x 1 mtr incl GI angle frame and GI sheet cover to the frame and fixing of 2 Nos LED tube light fitings of 20 watt, connecting electric supply to the frame with copper wire two core 1.5 sqmm from nearby electric source incl round steel pole minimum 12 feet long of suitable dia for errection of ground with PCC complete all as specified and directed.
M & L for defect rectification of HT 11 KV/LT 1.1KV cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3/3.5core. The fault locating equipments will be brought to site within 24 hours of instruction from Engineer-in-Charge complete all as specified and directed. Note:- Cable joint and its fixing shall be measured and paid saperately under respective item of schedule.
S & F in replacement of sheet metal enclosure double door suitable for SPN distribution boards when MCBs to be used having 200Amp rated bus bar 8 ways 240 V complete all as specified and directed.
All as per Item No 35.00 here-in-above but for bus bar 6 ways 240 V complete all as specified and directed.
All as per Item No 35.00 here-in-above but for bus bar 4 ways 240 V complete all as specified and directed.
S & F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B', breaking capacity 10KA complete all as specified and directed.
S & F in replacement MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA complete all as specified and directed.
S & F 10 watt Three star rating LED bulb with B22 Base cap, 1200 lumens, colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
Excavation in trenches in soft/loose soil not exc 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for taking out/laying cable pole &stay etc complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M & L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and after punning down sand cushioning will be 18 cm complete all as specified and directed. Note : 18 cm thick only will be considered for pryment purpose.
M & L common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 25 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and directed.
All as per Item No 46.00 here-in-above but size of cable 35 Sqmm 4 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 50 Sqmm 4 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 70 Sqmm 3.5 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 95 Sqmm 3.5 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 120 Sqmm 3.5 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 150 Sqmm 3.5 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 185 Sqmm 3.5 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 240 Sqmm 3.5 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 300 Sqmm 3.5 core complete all as specified and as directed.
All as per Item No 46.00 here-in-above but size of cable 400 Sqmm 3.5 core complete all as specified and as directed.
M & L for Straight through heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor under ground cable 1100 Volts 3.5/ 4 core 6 sqmm to 16 sqmm and testing after jointing complete all as specified and directed.
All as per Item No 57.00 here-in-before but for cable 3.5/4 core 25 sqmm to 50 sqmm complete all as specified and directed.
All as per Item No 57.00 here-in-before but for cable 3.5/4 core 70 sqmm to 120 Sqmm complete all as specified and directed.
All as per Item No 57.00 here-in-before but for cable 3.5/4 core 150 sqmm to 185 Sqmm complete all as specified and directed.
M & L for End Termination joints heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor under ground cable 1100 Volts 3.5/ 4 core 06 sqmm to 16 sqmm and testing after jointing complete all as specified and directed.
All as per Item No 61.00 here-in-before but for cable 3.5/4 core 25 sqmm to 50 sqmm complete all as specified and directed.
All as per Item No 61.00 here-in-before but for cable 3.5/4 core 70 sqmm to 120 Sqmm complete all as specified and directed.
All as per Item No 61.00 here-in-before but for cable 3.5/4 core 150 sqmm to 185 Sqmm complete all as specified and directed.
All as per Item No 61.00 here-in-before but for cable 3.5/4 core 240 sqmm to 300 Sqmm complete all as specified and directed.
M & L for augering upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified and dirtected.
Supply and laying 63/50 mm outer dia/ inner dia, double walled, corrugated DWC duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and directed.
Supply and laying 90/76 mm outer dia/ inner dia, double walled, corrugated DWC duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 ( using 40 mm graded stone aggregate) for foundation of poles complete all as specified and directed.
M & L for pre polished chequered cement concrete tiles of size 300mm x 300mm x 25mm thick, parallelogram or in any shape of any tint, heavy duty , set jointed and pointed with grey cement slurry, laid over 15 mm thick bedding layer of cement mortar (1:4) complete all as specified and directed.
M & L for surface exacavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
All as per Item No 73.00 here-in-above but size of mats 3mm thick for voltage upto 33 KV complete all as specified and directed.
Supplying, fixing, connecting, testing and commissioning cable jointing Kit for 11 KV (E) grade cable for straight through heat shrinkable type joint with jointing material and accessories for 95 sqmm 3 core XLPE, HT cable including cutting after taking down/out joint kit as existing at site complete all as specified and directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S & F 45 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy , cast alluminium alloy housing IP 66 protection, input voltage range 140-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, including taking down existing light fittings complete all as directed and specified.
All as per Item No 78.00 here-in-above but capacity of LED 60 watt complete all as directed and specified.
All as per Item No 78.00 here-in-above but capacity of LED 100 watt complete all as directed and specified.
S & F 30 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings complete all as specified and directed.
All as per Item No 81.00 here-in-above but capacity of LED 60 watt complete all as directed and specified.
All as per Item No 81.00 here-in-above but capacity of LED 120 watt complete all as directed and specified.
All as per Item No 81.00 here-in-above but capacity of LED 150 watt complete all as directed and specified.
S & F 10 watt led bollard light system lumen output not less than 80 lumen per watt, total system lumens not less than 3200 lumens, PF not less than 0.90, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, ,input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution including taking out old any type light complete all as specified and directed.
S & F Decorative LED Post Top Lantern light fitting with max. system wattage 40 watt and system lumen output not less than 80 lumen per watt, total system lumens not less than 3200 lumens, PF not less than 0.90, THD less than 10%, CRI not less than 70, CCT 5700 TO 6500k, surge protection 5 Kv,input voltage range 140V to 270V AC 50 Hz, 50000 burning hours,IP 65 class 1 protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect, uniform, glare free light distribution including taking out old any type light complete all as specified and directed. Notes: Name of the MAKE of the luminaire should be embossed on the luminaire fittings.
S & F in replacement Non metallic Junction box made out of thermoplastic size not less than 18 cm x10cmx8cm hinged with lockable arrangement including aluminium bus bar SPN capacity 40Amp with one No MCB 2 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole /grouting in PCC muff complete all as specified and directed.
M & L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M & L for Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. of grade Fe-290 (Gde E-165) complete all as specified and directed.
S & F 35 watt LED Flood Light fitting with not less than 110 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings complete all as specified and directed.
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface broken stone or boulders complete all as specified and directed.
S & F Electric shock treatment chart in wodden frame box complete all as specified and directed.
S & F in replacement of mild steel chequered plates duly painted with two coat of black bituminous paint over one coat of red oxide primer and cut to shape for cable duct complete all as specified and directed.
S & F in replacement of Rewirable switch fuse unit 4 pole, 63Amps, 415 volts in sheet metal enclosure including taking down old unsv fuse unit complete all as specified and directed.
All as per Item No 94.00 here-in-above but for switch fuse unit 4 pole, 100 Amps, 415 volts complete all as specified and directed.
All as per Item No 94.00 here-in-above but for switch fuse unit 4 pole, 32 Amps, 415 volts complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil n.exc 50m and making good the surface in any type of soil complete all as specified and directed.
S & F in replacement of multi standarad copper cable PVC insulated unsheated 1100 volts grade of size 10 Sqmm 3 Core making connection and testing complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh size and type and type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed.
S & F in replacement of MS galvanished chain link fencing with 3 mm dia and desired size including line wires including strain bolts, binding wire incl taking down old damaged fencing complete all as specified and directed.
S & F in replacement of mild steel screw bolts (machine made) with hexagonal head at one end and screwed the other or screwed both ends each screwed and to be fitted with washers and with hexagonal nut of exc 5 cm length with dia of shanis 11 to 15 mm etc complete all as specified and directed.
S & F in replacement of mild steel work such as in fencing post, tie bars etc including embedding into concrete and making holes for screwing of nut, bolts, cutting top to shape as directed, drilling holes, notching for wire etc confirming Fe 410-0 or Fe 310-0 complete all as specified and directed.
M & L in replacement for framed work as in doors, gates of angle Fe -410 gde E 250 qureed section with gussed plates complete drilled or welded to be prepared for hanging or sliding with and including either hooks and hinges complete all as specified and directed.
M & L for two coats of synthetic enamel paint over a coat of red oxide on steel surfaces exc 10 cm width or girth etc complete all as specified and directed.
M & L in replacement for steel work in tubular truss, purline rafter columns etc including welding ,butt welded tubes conferming to IS-1161-1979 grade St-240, complete all as specified and directed.
S & F in replacement of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed with self tapping screwas as specified fixed etc complete all as specified and directed.
M & L in replacement for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 Gde E-165 etc complete all as specified and directed.
M & L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and as directed.
Supplying and topping up of transformer oil of dielectric strength not less than 45 BDV to comply IS-335 of 1993 here-in- before, complete all as specified and directed. Note:- Oil shall be in company sealed barrel having BDV not less than 45 KV and as per manufacturers instructions.
S & F in replacement of Fire safety Axe with wodden glass box as standard complete all as specified and directed.
S & F in replacement of Fire Beater with wooden handle complete all as specified and directed.
S & F in replacement of isolator TPN of capacity 100 A, 415V complete as speciefied and directed.
All as per Item No 112.00 here-in-above but TPN of capacity 63A, 415V complete all as specified and directed.
S & F in replacement of Ammeter of size 96 x 96 having range 0-250A digital type including taking out old unsv complete all as specified and directed.
M & L for cutting the worn out/unserviceable lugs from the cables upto 50 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end from HT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning filling etc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all as specified and directed.
All as per Item No 115.00 here-in-above but for cables of size 70 Sqmm complete all as specified and as directed.
All as per Item No 115.00 here-in-above but for cables of size 95 Sqmm complete all as specified and as directed.
All as per Item No 115.00 here-in-above but for cables of size 120 Sqmm complete all as specified and as directed.
All as per Item No 115.00 here-in-above but for cables of size 150 Sqmm complete all as specified and as directed.
All as per Item No 115.00 here-in-above but for cables of size 185 Sqmm complete all as specified and as directed.
All as per Item No 115.00 here-in-above but for cables of size 240 sqmm to 300 Sqmm complete all as specified and as directed.
S & F in replacement of adjustable thermal and fixed magnetic release 63 Amps 4 Pole MCCB breaking capacity Icu 10KA complete all as specified and directed.
All as per Item No 122.00 here-in-above but for 100 Amps 4 Pole MCCB breaking capacity Icu 10KA complete all as specified and directed.
All as per Item No 122.00 here-in-above but for 125 Amps 4 Pole MCCB breaking capacity Icu 16KA complete all as specified and directed.
All as per Item No 122.00 here-in-above but for 250 Amps 4 Pole MCCB breaking capacity Icu 36KA complete all as specified and directed.
S & F in replacement of adjustable thermal and fixed magnetic release 160 Amps 4 Pole MCCB Breaking capacity Icu 35/36KA complete all as specified and directed.
All as per Item No 126.00 here-in-above but for 400 Amps 4 Pole MCCB breaking capacity Icu 35/36 KA complete all as specified and directed.
M & L for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions complete all as specified and directed.
M & L for Prelaminated particle board having thicness 18 mm, interior grade, prelaminated both sides with decorative choice laminations complete all as specified and directed.
S & F aluminium (extruded section body )Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed with fastening element complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor having cover plate length 150 mm complete all as specified and directed.
S & F door hinges suitable for aluminium door complete all as specified and directed.
S & F aluminium door handle with all suitable fixing elements complete all as specified and directed.
S & F in replacement of SMF VRLA battery 12 V , 100 AH with suitable copper wire single core of size 10 Sqmm with copper lugs connector complete all as specified and directed.
S & F in replacement multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 1.5 sqmm 3 core, drawing through tubular pole and GI brackets etc upto choke/lamp and making connections and testing for functioning of light fittings complete all as specified and directed.
All as per Item No 135.00 here-in-above but size of cable 2.5 sqmm 3 core complete all as specified and directed.
S & F 60 watt LED street Light fitting with not less than 110 lumen / watt delivered lumen efficacy , cast aluminium alloy housing IP 66 protection, input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 4 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings complete all as specified and directed.
S & F in replacement of Voltmeter of size 96 x 96 having range 0-600V digital type including taking out old unsv complete all as specified and directed.
S & F in replacement danger notice board of 1.6 mm thick mild steel sheet, vitreous enamelled white,with letters ,figure and conventional skull and bones in signal red colour, fixed with MS clamps made out of FI 25 x 3 mm duly painted the two coat of aluminium and GI, bolts and nuts for HT of 25x20cm size complete all as specified and directed.
M/S GURENDER SINGH (BID ID -3448764)
SUBHASH CHAND CONTRACTOR (BID ID -3442232)
PANWAR CONSTRUCTIONS (BID ID -3442483)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .