Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC PANDABESWAR PASCHIM BURDWAN 713346 | PANDABESWAR | PASCHIM BURDWAN | WEST BENGAL | 713346 | L1 | Accepted-AOC AS PER TCR | |
| 2 | L2₹7.6 L+₹14,472.82 (1.94%)Rejected-Finance BARDHAMAN BARDHAMAN 713378 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713378 | L2 | Rejected-Finance REJECTED AS PER TCR | |
| 3 | L3₹7.7 L+₹25,401.55 (3.41%)Rejected-Finance LAUDOHA LAUDOHA P S FARIDPUR BARDHAMAN BARDHAMAN WEST BENGAL 713385 | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713385 | L3 | Rejected-Finance REJECTED AS PER TCR |
Tender Value
₹7.5 L
EMD Value
₹9,400
Closing Date
14 Jan 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER, JHANJRA AREA
OFFICE OF THE GENERAL MANAGER, JHANJRA AREA, PO-LAUDOHA, BO, DIST. - PASCHIM BARDHAMAN, PIN-713385
Trans, install, fabri, comm. trial run of one 1000mm width, 1x90kW 550V, single drive belt conveyor along- 11D from 73L to 76L for development of trunk Heading of sector-F in R-VIIA seam at 3n4 Incline, J.P.C.
2022_ECL_266344_1
ECL/GM/JNR/EnM/e-Tender/ 22-23/A2/66,Dt.30.12.2022
Open Tender
Miscellaneous Works
Item Rate
30 days
JHANJRA UNDERGROUND
PLEASE REFER TENDER DOCUMENT
4 documents required · 4 mandatory
₹9,400
9 Mar 2023
3 Jan 2023
16 Jan 2023
3 Jan 2023
14 Jan 2023
4 Jan 2023
3 Jan 2023 - 9 Jan 2023
Amount
Transportation & installation of one no. 1000mm width, 1x90kW, 550V, single drive belt conveyor for a length of 92mtr from 73L/-11D to 76L/-11D in R-VIIA seam at 3&4 Incline, J.P.Colly.
Transportation of the 1000mm width, 1x90kW, 550V Drive Head complete including gear box, motor(90kW/550V), base frame, couplings, bearing blocks, fencing etc from surface by haulages and installation at 74L/-11D (R-VIIA) with necessary fabrication job.
Transportation of Discharge Unit complete with girders, strike plate, chute plates, scrappers etc from surface by haulages and installation at 73L/-11D (R-VIIA) with necessary fabrication job.
Transportation of Tail End Unit complete with fencing from surface by haulages and installation at 76L/-11D (R-VIIA) with necessary fabrication job.
Transportation of 92mtr. 1000mm belt conveyor structure complete with stringer, foot stool, top bracket, top & bottom roller etc. from surface by haulages and installation from 73L/-11D to 76L/-11D in R-VIIA seam.
Loading, transportation and unloading of one breaker(550V/200A),starter(550V/90kW), LS unit from surface to 16XD/71L(R-VIIA) with help of haulages.
200 mtrs manual transportation of one breaker(550V/200A), starter(550V/90kW), LS Unit from 16XD/71L(R-VIIA) to 74L/-11D(R-VIIA) and placing them.
Transportation of 250mtr 3.3kV grade 70 sq.mm. PVCDWA cable from surface after loading it on trolley and transport by haulages to 16XD/71L(R-VIIA).
Laying-Hanging of 250 mtr 3.3kV grade 70 sq.mm PVCDWA cable from 16XD/71L (R-VIIA) ACB to 74L/-11D (R-VIIA) ACB.
Transportation of 190mtr. 1000mm width PVC belting from surface after loading it on trolley and transport by haulages to 16XD/71L(R-VIIA).
200 mtrs manual transportation of 190mtr. 1000mm PVC belting from 16XD/71(R-VIIA) to proposed -11D(2nd) belt extension site.
Laying, lapping, jointing & tensioning of this 190mtr. 1000mm width PVC belting in proposed -11D(2nd) belt.
Transportation of 60 mtr belt sequence cable from surface to -11D tandem belt starter, then laying-placing them from 72L/-11D to 74L/-11D in R-VIIA seam.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) from surface to proposed -11D(2nd) belt installation site (R-VIIA) for 92mtr. belt and laying-placing them from 73L/-11D to 76L/-11D in R-VIIA seam
Testing, trial run, alignment & commissioning of this belt conveyor from 73L/-11D to 76L/-11D in R-VIIA seam.
Civil foundation works for installation of 1X90kW, 550V, 1000mm wide belt conveyer drive head, discharge unit,and platform for ACB, Starter at 74L/-11D IN R-VIIA seam of 3&4 incline, JPC. (with GST)
Recess cutting in stone.
Cleaning of debris.
Sand filling.
Brickwork with flyash bricks in foundation & plinth in cement mortar 1:6
Providing and lying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement :2 coarse sand (zone- III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources.
12mm cement plaster of mix 1:6
Loading material into tub and unloading at site.
Roof heightening by drilling blasting in stone, cleaning, roof bolting including cost of drill rod, drill bit for installation of proposed -11D(2nd) belt conveyor in R-VIIA seam of 3&4 incline under JPC.
Roof heightening by drilling, blasting in stone including dressing, cleaning with cost of drill rod and drill bit.( Excluding cost of explosive & detonator).
Roof bolting including carrying of materials from surface to u/g side, drilling, grouting & cost of drill rod and drill bit.
Supply of Materials
Supply of DA cylinder
Supply of oxygen cylinder
Supply of MS NUT BOLT 5/8”X2”
Supply of HT NUT BOLT of M20X75mm
Supply of HT NUT BOLT of M20X65mm
Total impact of GST for the purpose of CTC
BABLU SINHA
RINA ENTERPRISE
stage.html
html • 0.04 MB
techsummary_275519.pdf
PDF • 2.20 MB
finsummary_275519.pdf
PDF • 2.20 MB
WO66.pdf
PDF • 4.37 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .