Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹46.5 L+₹22,410 (0.48%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹52.5 L+₹6.2 L (13.4%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹55.3 L+₹9.0 L (19.5%)Rejected-Finance 2549 NATHA SINGH STREET MEHNA MOHALLA BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹57.4 L+₹11.1 L (24.0%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
26 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Vipin Chandra Rai
GE Utility Bathinda
REPAIRS /MAINTENANCE OF STPs AT DIFFERENT LOCATIONS UNDER GE (U) BATHINDA.
2023_MES_630839_1
8761/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
Class D cat a ii
9 documents required · 9 mandatory
₹500
Garrison Engineer (U) Bathinda
₹1 L
Yes
19 Jan 2024
2 Dec 2023
28 Dec 2023
2 Dec 2023
26 Dec 2023
18 Dec 2023
Amount
Dewatering/bailing out raw sewage and scraching the inner surface of the open sewage collection tank of any sizes, with the help of pressure jet pump & other required equipments and removing any silt, sludge, raw material of sewage from the well with the help of any T & P as required and throwing it away 100 mtr from the STP complete all as directed by Engineer-in-Charge. (All STPs).
Cleaning and removing sludge from walls /floor of one Nos Equilization tank off sizes, with the help of pressure jet pump & other required equipments and depositing where directed at a distance 100 mtr away from outer wall of STP including white wash to walls complete all as directed by Engineer-in-Charge. (All STPs)
Cleaning and removing sludge from walls /floor of one Nos Treated water tank with the help of pressure jet pump & other required equipments and depositing where directed by Engineer - in - Charge at a distance 100 mtr away from outer wall of STP including white wash to walls complete all as directed by Engineer-in-Charge. (All STPs)
Cleaning,removing and bailing out stagnated sewage or sludge from walls/floor and any light particle with the help of pressure jet pump & other required equipments from two Nos MBBR/FAB Reactor reactor inner surface off sizes and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge. (All STPs) Note : New media for topping up will be paid and measured separately under respective item of BOQ.
Cleaning and removing of sludge from walls/floor of tube settler tank off sizes after taking out the tube settler media with the help of pressure jet pump & other required equipments and depositing where directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of any sizes from tube settler media and cleaning the tube settler after all cleaning fixing new wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed (All STPs).
Cleaning of existing DMF by opening the lid of any sizes and removing deposition complete, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity of sizes complete all as directed. (All STPs)
Cleaning of existing ACF by opening the lid of any sizes and removing deposition complete, remove water strainer and refix the same after necessary modification, cleaning and topping of media as required quantity off sizes complete all as directed. (All STPs)
Cleaning and removing of sludge from walls/floor of Raw Water Collection Tank located at various places with the help of pressure jet pump & other required equipments and depositing where directed at a distance 100 mtr away from outer wall of Raw Sewage Collection Tank including bailing out all material from inside the tank complete all as directed. (Shivaji Pump house No 01, 02 & 03, Ranjit/Gobind Raw Sewage Tank, Jadunath Raw Sewage PH, Gurnam Enclave Raw sewage collection tank).
Cleaning and removing sludge from walls /floor of Treated water tank (located at 11 different locations for arboriculture) with the help of pressure jet pump & other required equipments and depositing where directed at a distance 100 mtr away from outer wall of STP including white wash to walls complete all as directed by Engineer-in-Charge.
Taking out solid dry sewage waste from 06 x sludge beds (except shivaji STPs where only three beds) off sizes and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed.(All STPs)
M&L for area cleaning under pumphouse premises by cutting/scraping of grass, unwanted trees, plant, levelling of earth surfaces, filling of digs complete all as directed.
Dismantling motor of capacity upto 7.5 HP, any make and types from the foundation and disconnection of motor electric cable connection and earthing etc. and transportating to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding including rewinding the motor after cleaning the rotor and stator with super enameled copper winding wire of suitable turn and gauge as per IS Code-13730 including varnishing, re-assembling the complete motor and installing at site with electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge (Air Blower motor). Note:- (i) Cost of copper wire, T&P, minor repair including minor spare are included in the quoted rate of this item.
All as per serial item No. 12 above but for motor of capacity 8.50 HP to 11.90 HP.
All as per serial item No. 12 above but for motor of capacity 25 HP.
All as per serial item No. 12 above but for electric induction motor AC 3 Phase, capacity upto 7.5 HP.
All as per serial item No. 12 above but for electric induction motor AC 3 Phase, capacity 20 and 25 HP
All as per serial item No. 12 above but for electric induction motor AC 3 Phase, capacity 10 HP. Note for serial item No. 12 to 17.: Cost of copper wire, T&P, minor repair including minor spare are included in the quoted rate of this item.
Disconnecting the centrifugal/monoblock pumping sets off sizes & any make from motor and all water connections and removing/taking up from foundation and transporting to civil workshop for repair/strip opening and repairing of pumping sets by changing defective/unserviceable parts such as bearing,shaft,impeller,bush,gland plate and re-assembling including oiling greasing replacement of worn out nuts,bolts gasket etc,and installing in its original position at site making all connection ,commissioning and testing etc complete all as directed. Note: The spare parts required shall be measured and paid separately under respective item as supply only.
Supply only steel distance pieces suitable upto 40 HP centrifugal/monoblock pumping sets complete all as directed. Make :- Kirloskar / As per Sample
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set off any sizes pumping set of any make complete all as directed.
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping set of any sizes as per site requirement complete all as directed. Make- Kirloskar or as per existing.
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set off any capacity as per site requirement. complete all as directed by Engineer-in-charge. Make- Kirloskar or as per existing.
Supply and fixing in repair of MCCB 63 Amps to 100 Amp, 3 pole, 415 Volts , 36KA, Ics=100% Icu conforming to IEC-60947-2, Adjustable Thermal (0.7 to 1 x In) and Fixed Magnetic Release, complete all as directed by the Engineer in Charge.
All as per serial item No. 23 above but for MCCB 125 Amp 3 pole, 415 Volts , 36KA.
All as per serial item No. 23 above but for MCCB 200 Amp 4 pole, 415 Volts , 36KA.
All as per serial item No. 23 above but for MCCB 250 Amp 4 pole, 415 Volts , 36KA. Makes for serial item No. 23 to 26: LEGRAND / L&T / SCHNEIDER / HAVELLS INDIA LTD / SIEMENS.
M & L for removing of all items like MCCB, Contactor, relays etc and refix the same duly cleaning/removing carbon etc scaling from LT Panel existed at Various STPs under GE Utility Bathinda complete all as directed. Note : (i) MCCB, Contactor etc measured and paid separately. cost of minor parts like thimble, MCBs upto 32A and labour charges are included in this item. No extra cost to be paid on this account.
Supply and fix in repair ball bearing of DE & NDE for electric motor of any capacity upto 40 HP complete all as directed.
Lifting the submersible pump and motor of capacity up to 7.5 HP after disconnecting electric cable connection and transportating to civil workshop for repair and rewinding the submersible electric motor of any sizes by using PVC insulated copper conductor winding wire of suitable turn and gauge as per the original, reassembling the complete submersible pump and motor lowering including reconnecting the electric cable connection and testing complete all as directed by Engineer-in-Charge.
All as per serial item No. 29 above but for submersible pump and motor of capacity 20 HP to 25 HP
All as per serial item No. 29 above but for submersible pump and motor of capacity 60 HP. Note for serial item No. 29 & 31: (i) PVC insulated copper winding wire is included in this item and nothing extra shall be paid on this account. (ii) The rate of minor repair like shaft grinding including filling material ,seals,brass bush are included in quoted rates of this item and nothing extra shall be paid on this account. (iii) The T & P and vehicles will be arranged by contractor at his own cost and arrangement for transportation of submersible pump and motor to civil workshop for repair and back and the cost of this aspect is included in this item and nothing extra shall be paid on this account.
Supply and fixing in repair mechanical seal & oil seal for pumping set of any capacity complete all as directed.
Supply and fixing in repair Relay of upto 23 Amp ranges and suitable for upto 7.5 HP starter (Dol/Star delta) complete all as directed.
Supply and fixing in repair Relay range (above 23 Amp) for 12.5 HP to 40 HP starter(Dol/Star delta) ocomplete all as directed. Makes for serial item No. 30 & 31: LEGRAND / L&T / SCHNEIDER / HAVELLS INDIA LTD / SIEMENS.
Supply and fixing in repair blower belts of suitable size of any size (as per site requirement) for Air Blower electric motor complete all as directed.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase, MNX-A2 or MNX A1 complete all as directed.
Supply and fixing in repair power Contactors 415 volts ,50 cycles,3 phase MCX 33 complete all as directed. Make for serial item No. 35 to 36:- L & T/ Havells/ Siemens/Legrand
Supply and fixing in repair ball bearing of any sizes suitable for Air blower off any capacity complete all as directed.
Supply and mixing chlorine dioxide powder (SCS 10K) chemical or equivalent for treatment of raw sewage treated water complete all as directed.
Taking out CI foot valve/Non return valve of any size from jack well approximate 3 mtr deep and refixing the same in original positions after fixing leather buffalow complete all as required at site and as directed. Note : Leather buffalow /nut bolts and rubber sheet will be measured and paid seperately under appropriate item of BOQ as supply only.
Supply only leather buffalow superior quality as per sample complete all as directed.
Supply only oil imeressed graphite gland packing off sizes of superior quality along with grease and cotton waste complete all as directed.
Supply and fix in repair submersible flat copper cable multi stranded 16 Sqmm, 3 core including connection and testing complete all as directed. Make: Havells / Finolex / Polycab
Supply only air compressor oil for air blower complete all as directed.
Material and labour for detecting and repairing the sewage leakage in already laid GI pipeline of any upto 80 mm bore (Treated Sewage water pipeline) including necessary excavation and earth work, bailing out stagnated /muddy sewage water complete all as directed by Engineer-in-Charge.
Material and labour for detecting and repairing the sewage leakage in already laid CI/MS pipeline of 100/150/200mm bore from last manhole to Raw Sewage Pump House, including necessary excavation and earth work, bailing out stagnated /muddy sewage water complete all as directed by Engineer-in-Charge.
Supply, fixing in repair commissioning and testing of Digital Chlorine testing Kit for all existing STPs complete all as directed by Engineer-in-Charge.
M&L for preparation of old steel and iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Cast Iron butterfly valves of size 150 mm dia complete all as directed.
All as per serial item No. 49 above but for 125 mm dia cast iron butterfly valve.
All as per serial item No. 49 above but for 100 mm dia cast iron butterfly valve.
All as per serial item No. 49 above but for 80 mm dia cast iron butterfly valve.
All as per serial item No. 49 above but for 50 mm dia cast iron butterfly valve.
S&F in repair 80 mm dia sluice valve, ISI marked PN 1.6 confirming to IS-14846-2000, both end flanged ,drilled , steel spindle and iron wheel handle , CI gate with MS ring including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed.
All as per serial item No. 54 above but for 100 mm dia sluice valve.
All as per serial item No. 54 above but for 150 mm dia sluice valve.
S&F in repair 100 mm dia NRV, ISI marked PN 1.6 both end flanged ,drilled, including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed. Make for serial item No. 49 to 57: KIRLOSKAR / LEADER / L&T /UPADHYA / ZOLOTO
S & F in repair energy efficient LED street light fitting of 60 Watt capacity with toughened clear glass , LED chip efficacy > 130 lumen / watt, system efficacy > 120 lumen / watt, luminarie shall be mandatory brand embossed on luminaries, potted antivibration driver. The driver shall be able to withstand for indoor at 440V for 8 hours . The driver should have fascility and cut off voltage. Input over voltage protection will be > 300 Volt AC and for cut off the luminaires should withstand for 48 hours at 100 Volt AC. The LED efficacy shall be more than 85% at a junction temperature of 85 degree centigrade. All screws of the luminaires should be SS304. Luminaires pressure dicast aluminium housing with mendatory secondary optics, CCT: 5700K ANSIBIN, CRI > 70, LED source : 1-5 Watt high power type , driver of luminaire shall be preferably in separate compartment another optical compartment .The LED driver shall be constant current type fully potted. Driver shall be provided for all luminaires. It should be moiture resistant and fire reterdant. At least industrial grade or higher grade component should be used for manufacturing of driver. The driver shall be able to withstand surge (EFT+ESD interference) of minimum 4 KV. Luminaire shall have surge protection device of minimum 10 KV inside the driver compertment. The driver shall have under voltage, over voltage and short circuit protection and auto recovery mode. Total harmonic distortion shall be < 10% with power factor minimum 0.95. It should give consistent performance in the input voltage range of 120 V - 270 V at 50 Hz. Luminaires shall be mandatory brand embossed of luminaries and including all electric connection and accessories complete all as directed. Make- Crompton / Phillips / Wipro / Havells/Bajaj/Jaquar
Material and labour for aluminum work to prepare steps for usage of STPs of weight 9 Kgs with fitting of steps at every 0.60 m including taking down existing one complete all as directed by Engineer-in-Charge.
Material and labour for MS frame work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering. doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165 complete all as specified and dirtected by Engineer-in-Charge.
Taking out old unservicable rusted / corroded existing GI pipe 100 mm bore and connections including all fittings from raw sewage tank complete all as directed.
All as per serial item No. 61 above but for GI pipe of 80 mm bore
All as per serial item No. 61 above but for GI pipe of 50 mm bore.
All as per serial item No. 61 above but for GI pipe of 25 mm bore.
Supplying, Laying, jointing and testing of GI steel water tubing 100 mm bore ISI marked heavy grade galvanised including flanged ended & including tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed joint laid in trenches/under road complete all as specified and directed.
All as per serial item No. 65 above but for GI pipe of 80 mm bore.
All as per serial item No. 65 above but for GI pipe of 50 mm bore.
All as per serial item No. 65 above but for GI pipe of 25 mm bore.
Supplying, laying, jointing, commissioning & testing MS pipes flanged ended conforming to IS-8329 -2000 in any length of size 300mm bore laid in trenches or on wall mounting or any places including taking out of old pipe complete all as specified.
All as per serial item No. 69 above but for MS pipe of 200 mm bore.
All as per serial item No. 69 above but for MS pipe of 150 mm bore. Make for serial item No. 65 to 71 TATA / JINDAL / SWASTIK / SURYA PRAKASH
Supply and fixing in repair CI fittings and specials up to 300 mm dia (any type, radius and angle) like bends, tee, tail piece elbow single branch ‘Y’ junction, double branch, or taper and flanged, straight bend, increasing decreasing or double socket, reducer complete all as specified and as directed.
Testing of Raw Sewage Water (Inlet) parameters like BOD, COD, TSS, FC, pH, Total N, from Government approved Lab including proper collection sample in presence of all concerned complete all as directed. Note: The transportation charges and all other expenses are deemed to be included in this rate. No extra claim shall be entertained in this regard.
Testing of Treated Sewage Water (outlet) parameters like BOD, COD, TSS, FC, pH, Total N, from Government approved Lab including proper collection sample in presence of all concerned complete all as directed. Note: The transportation charges and all other expenses are deemed to be included in this rate. No extra claim shall be entertained in this regard.
Supply, install, testing and commissioning in replacement flowmeter installed at all the STPs, complete all as directed. Make SIEMENS model No FM 5000 or as per existing at site.
Construction of pit chamber at the face of sewage inlet water with cover of stainless steel strainer with opening face gate for cleaning, to prevent garbage or large suspended solid coming through inlet water including demolishing the existing one complete all as directed.
Materials and labour of construction of Fire Fighting Point of size 2.70 m x 2.20 m x 0.75 m made out of angle iron of size 50 mm x 50 mm x 6 mm with 2 mm thick MS sheet covered at top including two coats of synthetic enamel paint over a coat of primer in all iron surface both external and internally including construction of foundation with brick work in cement mortear (1:4) and other as per existing shed at Jadunath Enclave STPs including demolishing the existing one complete all as directed by Engineer-in-Charge.
M/s badrinath Traders
RS ENTERPRISES
VISHAV CONSTRUCTIONS
SS CONSTRUCTION
SWARN SINGH AND CO.
PREM ENTERPRISES
GILL ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .