CWE Ranchi
Headquarters Commander Works Engineers Ranchi Military Engineer Services Dipatoli Mil Station Hotwar, Ranchi-834009
AUGMENTATION OF HT DISTRIBUTION NETWORK AT CERTAIN POCKETS AND PROVN OF 03 X RMU (RING MAINT UNIT) AND CONNECTED ITEMS AT DIPATOLI MIL STN UNDER GE DIPATOLI
2026_MES_789917_1
80599/1744/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE Dipatoli
As per tender documents
6 documents required · 6 mandatory
₹1,000
GE Dipatoli
₹1.5 L
Yes
HQ CWE Ranchi
17 Sept 2026
17 Sept 2026
22 Oct 2026
17 Sept 2026
15 Oct 2026
8 Oct 2026
17 Sept 2026 - 24 Sept 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and Labour XLPE insulated, screened, PVC edded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,11000 volts(Earthed), grade cross sectional area 95 sqmm 3 core complete all as specified and directed. | 2,530 | RM | - | - |
| 2 | Material and Labour cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and directed. | 12 | Each | - | - |
| 3 | Material and Labour cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and directed. | 2 | Each | - | - |
| 4 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr in deep for foundation etc. or for shafts, wells, cesspits, mainholes, pierholes etc. in hard dense soil for foundation and getting out and levelling of bottom surface to required level complete all as specified and directed. | 722.24 | Cum | - | - |
| 5 | Material and Labour for river washed and screened, dry sand for filling in trenches/ sub stations below and around underground cables for cushioning of cables etc complete all as specified and as directed. | 162.5 | Cum | - | - |
| 6 | Supplying and laying unreinforced precast cement concrete cable covers, Class HV, Type- 1, Flat, size 300 mm x 180 mm x 40 mm in trenches for cable protection, embossed with "MES 11 kV HT ELECTRIC" on the top surface complete all as specified and directed. | 11,285 | Each | - | - |
| 7 | Returning filling including leveling, watering and well ramming soil in layers not exceeding 1.5 m above the starting level complete all as specified and directed. | 481.83 | Cum | - | - |
| 8 | Removing the excavated materials not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level complete all as specified and directed at site. | 186.88 | Cum | - | - |
| 9 | S & F Cable route indicator/ Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with "MES 11 KV CABLE /MES 11 KV HT JOINT" embossing on cable route Indicator/ Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and directed. | 14 | Each | - | - |
| 10 | Taking down/ dismantling 11 kV insulators of any size complete all as specified and directed. | 30 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
1744Tender.pdf
Tender Documents • 0.63 MB
BOQ_885495.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .