| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹6.3 L+₹8,933 (1.44%)Rejected-Finance | L2 | Rejected-Finance Highest amount quoted | |
| 3 | L3₹6.9 L+₹64,862 (10.4%)Rejected-Finance | L3 | Rejected-Finance Highest amount quoted |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
21 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIR AND MAINTENANCE OF SUMMER AND WINTER APPLIANCES IN ARMY AREA MOUNT ABU UNDER AGE (I) UDAIPUR
2023_MES_604357_1
8817/E8/AGE (I) UDAIPUR
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA MOUNT ABU
as per tender documents
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹15,000
Yes
2 Aug 2023
20 Jun 2023
26 Jul 2023
20 Jun 2023
21 Jul 2023
6 Jul 2023
Amount
Material & Labour for taking down geyser of capacity-50 ltrs of any type/make cleaning & descaling inner vessel assy, proper refixing and carry out following test, i.e. leakage, water heating, preset temperature cutoff/restart etc complete all as specified and directed by Engr-in-Charge
-Ditto- All as per above item No 1 but for 25 ltrs geyser.
Supply and replace PVC connection heavy duty, nylon braided, suitable for hot water, with brass alloy chromium plated, nuts and nylon washers complete of size 15mm dia x 450mm long complete all as specified and directed by Engr-in-Charge.
-Ditto- All as per above item No 3 but 600mm long. (Make : Prayag/Polytuf/Jaquar).
Supply, repalce and connect in repairs PVC insulated and sheated 1100 Volts grade flexible three core insulated and sheated multistranded copper conductor cable of size 40/.0076mm complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs SP metal clad pulg outlet with sheet metal enclusure with plug top and MCB SP-20Amp complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs SPN metal clad pulg outlet with sheet metal enclosure complete with plug top and MCB SPN-25Amp all as specified and directed by Engr-in-Charge.
Supply & replace in repairs heating element ISI marked of suitable type as per existing including rubber ring clamping screws etc complete of 1.5KW complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs heating element ISI marked of suitable type as per existing including rubber ring clamping screws etc complete of 2.0KW complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs thermostatic switch ISI marked for geyser as per existing range 15-65 degree temparature complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs brass chromium plated horizontal / vertical non return valve of size 15mm dia bore ISI marked on inlet side of geyser complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs pressure release valve of size 15mm ISI marked for geyser complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs brass nut fusible plug for geyser complete all as specified and directed by Engr-in-Charge.
Material & Labour for drilling hole in wall, grounting rack bolt not less than 100mmm long for holding geyser upto 50 ltrs in wall including making good and matching existng surface and finish all as directed.
Supply & replace in repairs indicating lamp of red and green colour ISI marked for geyser complete all as specified and directed by Engr-in-Charge.
Supply & replace in repairs botton cover including bottom split inspection cover for geyser cap - 25/50 ltrs of any make ISI marked complete all as specified and directed by Engr-in-Charge
Material & Labour for scrapping old paint, painting one coat of synthetic enamelled paint of approved quality for geyser cap. - 25/50 ltrs of any make & type. Note : Rates are deemed to be included for taking down geyser in location and position with nut & bolts, disconnecting and reconecting electrical/water connection complete all as specified and directed by Engr-in-Charge.
Material & Labour for writing MES Number on geyser, water cooler and fan etc. in letters of size 25mm width with synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Supply & replace three pin metal top for AC box complete all as specified and directed by Engr-in-Charge.
Material & Labour for replacement of unsv hot water tank capacity 1000 Ltrs in repair with properly sealing the joint complete with fitting and fixtures/accessories and connect with solar panel ISI marked and complete all as specified and directed by Engr-in-Charge.
Taking down old unsv GI pipe and supply and laying new GI pipe med grade incl all GI fittings, on wall/floor or following sizes:-
15mm dia
20 mm dia
25 mm dia
Supply & Fixing in repair for providing 50mm thick insulation with glass wool, chicken mesh & aluminum sheet (26 guage) thick on existing GI pipe for solar heating system of following sizes of GI pipe:-
20 mm dia
25 mm dia
Taking out lod unserviceable valve and Supply & Fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of following sizes:-
20 mm dia
25 mm dia
Taking down & supply and fixing of Copper Absorber of follwing specification :No. of Fins & Tubes : 09 Nos. Absorber Area : 2 Sqm Copper Riser : Dia. 12.7mm x 0.45mm thik Copper Absorber sheet : 0.10 Thk 2 No. Copper Header : Dia. 25.4 mm x 0.60 mm thik Header Inlet / Outlet : Brass Flange with necessary asbestos gasket & rubber grommet complete all as specified and directed by Engr-in-Charge.
Taking down and Supply & Fixing rubber U-channel for solar collector, complete as per required at site complete all as specified and directed by Engr-in-Charge.
Taking down and Supply & Fixing inter connection GI tee, of 25mm bore, complete as per required at site complete all as specified and directed by Engr-in-Charge.
Taking down solar galss and Supply & Fixing new solar glass 4mm thick, toughened having transmitivity 85% and seated with U-type EPDM rubber complete all as specified and directed by Engr-in-Charge.
Material & Labour for flushing, pressurising the system, leakage, testing vacuumisation & gas charging and replacement of filter/stainer including testing at site for refrigerator of cap 210-310Ltrs complete all as specified and directed by Engr-in-Charge.
Material & Labour for flushing, pressurising the system, leakage testing vacuumisation & gas charging and replacement of fiter/stainer including testing at site for deep freezer of cap 320 ltrs complete all as specified and directed by Engr-in-Charge.
Repair of voltage stabilizer upto 5 KVA single phase 240 volt by replacing electronic circuit and unsv accessories for use in Ac and refrigerator and testing complete all as specified and directed by Engr-in-Charge.
Supply & replace fan suitable for frost free double door refrigerator complete all as specified and directed by Engr-in-Charge.
Supply & replace STAR RELAY for regrigerator of any make or model complete all as specified and directed by Engr-in-Charge.
Supply and replace OVERLOAD PROTECTOR for regrigerator of any make model complete all as specified and directed by Engr-in-Charge.
Supply and replace HERMATIC SEALED UNIT suitablefor regfrigerator of cap 286/310 ltrs complete all as specified and directed by Engr-in-Charge.
Supply and replace THERMOSTAT suitable for refgrigerator complete all as specified and directed by Engr-in-Charge.
Taking down of window/split type A/C, washing and cleaning of cooling coil, condenser with caustic soda. Replacement of air filter, oiling of fan motor, checking, testing and refixing the same after replacing the air filter at site complete all as specified and directed by Engr-in-Charge.
Material & Labour for flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure including testing at site for window type AC cap 1.5 ton complete all as specified and directed by Engr-in-Charge.
Material & Labour for flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure including testing at site for split type AC cap 1.5/2.0 ton complete all as specified and directed by Engr-in-Charge.
Supply & replace HERMATIC SEALED UNIT suitable for window type AC, flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropiate pressure including testing at site complete all as specified and directed by Engr-in-Charge.
Supply and replace HERMATIC SEALED UNIT suitable for deep freezer/Chiller RO Aquapura, flushing, pressuring the system, leakage testing vacuumisation and gas charging at appropriate pressure includiing testing at site complete all as specified and directed by Engr-in-Charge.
Supply & replace condenser fan motor suitable for deep freezer cap. 320 ltrs complete all as specified and directed by Engr-in-Charge.
Supply and replace running capacitor 36 mfd suitable for window type AC cap 1.5 ton complete all as specified and directed by Engr-in-Charge.
Supply & replace starting capacitor 60/80 mfd suitable for window type AC cap 1.5 ton complete all as specified and directed by Engr-in-Charge.
Supply & replace THERMOSTAT suitable for window type AC cap 1.5 ton of Make : Indfoss / denfoss complete all as specified and directed by Engr-in-Charge.
Supply & replace RELAY WITH OVERLOAD suitable for window type AC cap 1.5 ton complete all as specified and directed by Engr-in-Charge.
Supply & replace BLOWER FAN MOTOR 1/8 HP suitable for window type AC cap 1.5 ton complete all as specified and directed by Engr-in-Charge.
Supply & replace of universal PCB & remote for window/split type AC and testing complete all as specified and directed by Engr-in-Charge.
Supply & replace SPS candle for chiler cum RO unit complete all as specified and directed by Engr-in-Charge.
Supply & replace carbon candle for chiller cum RO unit complete all as specified and directed by Engr-in-Charge.
Repair of solar panel structure by scraping, smootning surface and painting two coat of rubber paint over angles frame structure of approved paint complete all as specified and directed by Engr-in-Charge.
Taking down old U/S water heater storage type & deposite to MES store and Supply & fix Water heater storage type, electric, capacity 25 litres 5 star rating complete all as specified and directed by Engr-in-Charge.
Dismantling carefully and taking out/ removing of old copper winding of ceiling fans of size 1200 mm sweep any type of model or any vintage of any make and rewinding with New super enameled copper winding wire of existing gauge as per old copper winding including proving insulation and vamishing (Golden), Cleaning, Oiling, Greasing etc and refixing all the parts such as capacitor, bush, bearing, shaft, etc complete and Painting of required fan with blade set of any size complete, with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dust etc & refitting at the same building/point all as directed. Make of winding wire-Devidayal/ USHA/Chetak of appropriate gauge as directed by EIC.
Supply & replace on line booster pump single phase with automatic pressure regulation upto 4.0 kg/Cm sq.
Taking out old unsv syphon assembly complete from 25/50 ltrs geyser from site and Supply & Fixing new syphon assembly complete as per existing size and type complete all as specified and directed by Engr-in-Charge.
Taking down old U/S exhaust fan, deposited to MES store and fixing only Metal body exhaust fan of size upto 380 mm sweep with louver single phase 240 Volts connected complete all as directed. Note : Exhaust Fan with accessories will be issued under Sch 'B'. Contractor will provide fixing material such as nut, bolts, fasteners etc to fix the exhaust fan and making good the disturbed surface where minor masonery work will carried out to match the existing surface.
Material and labour for making hole on wall to fix the exhaust fan of size upto 380 mm sweep complete all as specified and directed by Engr-in-Charge.
Dismantling carefully and taking out/ removing of old copper winding of exhaust fans of size 380/400 mm sweep any type of model or any vintage of any make and rewinding with New super enameled copper winding wire of existing gauge as per old copper winding including proving insulation and vamishing (Golden), Cleaning, Oiling, Greasing etc and refixing all the parts such as capacitor, bearing, shaft, etc complete and Painting of required fan with blade set of any size complete, with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dust etc & refitting at the same building/point all as directed. Make of winding wire-Devidayal/ USHA/Chetak of appropriate gauge as directed by EIC.
Supply and replacement of ceiling fan blade aluminium metal white colour for 1200 mm sweep ceilling fan complete all as specified and directed by Engr-in-Charge.
Supply only capacitor of 2.5 MFD all as specified.
Supply only heating element ISI marked of suitable type as per existing including rubber ring clamping screws etc complete of 1.5KW.
Supply only heating element ISI marked of suitable type as per existing including rubber ring clamping screws etc complete of 2.0KW.
Supply only thermostatic switch ISI marked for geyser as per existing range 15-65 degree temparature.
naveen enterprises
KAVYA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .