| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC | ₹24.5 L Quoted ₹25.4 L | L1 | Accepted-AOC SINCE L1 |
| 2 | L2₹26.3 L+₹90,446.52 (3.56%)Rejected-Finance | ₹26.3 L+₹90,446.52 (3.56%) | L2 | Rejected-Finance SINCE NOT L1 |
| 3 | L3₹28.0 L+₹2.6 L (10.3%)Rejected-Finance | ₹28.0 L+₹2.6 L (10.3%) | L3 | Rejected-Finance SINCE NOT L1 |
| 4 | L4₹28.4 L+₹3.0 L (11.9%)Rejected-Finance PLOT NO 106 MIDC SATPUR SATPUR MIDC AREA SATPUR NASHIK MAHARASHTRA 422007 UDYAM MH 23 0018515 | NASHIK | MAHARASHTRA | 422007 | ₹28.4 L+₹3.0 L (11.9%) | L4 | Rejected-Finance SINCE NOT L1 |
| 5 | L5₹32.4 L+₹7.0 L (27.7%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹32.4 L+₹7.0 L (27.7%) | L5 | Rejected-Finance SINCE NOT L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
18 Sept 2021, 5:00 pmClosed
GE DEOLALI
GE DEOLALI, 422401
REPAIRS AND MAINT OF EXTERNAL ELECTRIC NETWORK, FEEDER PILLAR, LT SWITCH GEAR AT SECTOR I UNDER THE AOR OF GE DEVLALI
2021_MES_469954_1
8005/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE DEOLALI
CLASS D cat b i
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹70,000
Yes
1 Nov 2021
23 Aug 2021
20 Sept 2021
23 Aug 2021
18 Sept 2021
6 Sept 2021
Amount
Excavation in trenches in soft/ loose soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for lying of electric cable, pole foundation and stays etc and getting out, trimming the sides, forming bottom surfaces to required level complete all as specified and directed by Engr-in-charge.
All as per item No. 1 above but exceeding 1.5 mtr and not exc.3.0 mtr deep
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 250mm thick after cable are laid and tested all as specified and directed.
Removing excavated material (Surplus soil) to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point all as specified and directed.
M&L for sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, total 23 CM complete all as specified. Note - for measurement purpose punned thickeness 18 CM shall be considered
S &L sub class B bricks having minimum compressive strength 75 Kg/Sqcm2 laid in trenches for cable protection etc complete all as directed by Engineer -in-Charge.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, complete all as specified.
M&L for cement concrete 1 : 4 : 8 type D-2 using 40 mm graded stone aggregate as in foundtion for pole including necessary form work all as specified and directed
M & L for cement concrete 1 :3 :6 type C-1 using 20 mm graded stone aggregate including necessary form work all as specified and directed
M&L for XLPE insulated armoured heavy duty electric cable with multi stranded aluminium conductor, 1100V grade, cross sectional area as given below:-
150 Sqmm 3.5 Core
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 3.5 Core
25 Sqmm 4 core
16 sq mm 4 core
10 Sqmm 4 core
2 core 10sqmm
S&F in repairs 'Tubes "light grade" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes complete all as specified and directed of following bore dia:-
100 mm dia
80 mm dia
50 mm dia
40 mm dia
Dismantling and taking down any type of LT poles from any location all as specified and directed
Supply, Install and errect in true vertical position steel tubular swaged poles in replacement complete with MS base plate of 6mm of size 300mm X300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer and two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete complete all as specified and as directed Note: Excavation and earth work ,PCC in foundation /plinth block/coping shall be measured and paid for separately
Dismantling cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
Supply and fixing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including a coat of red oxide primer one underand & one finishing coat complete all as specified and directed.
Supply and fix in replacement HT 11 KV outdoor non-linear type lightening arrestor, expulsion type with mountings, accessories complete fixed on cross arms of two polestructure/GI flat strip and connect with same size of ACSR conductor encased in PVC alkathine pipe with all fittings connected to earth stripwith nut, bolt, washer transmission class having discharge capacity of 65kilo Amps and suitable for working pressure 11 KV complete all asspecified and directed complete.
Dismantling and Taking down of Gang operating Device including Drop Out Fuse from Two/ Four pole structure All as specified
Supply, installation and testing of gang operated air break switch in replacement 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism having 11 KV and 12 insulators suitable for 11 KV, 50 C/s, 200 amps capacity including mounting on HT poles and necessary electrical connections complete all as specified and directed.
S&F drop-out fuse unit, in replacement expulsion type for out door air break gang operated switch, single pole mounted on and including insulators and jumpers for 11kv working pressure fixed to and including MS channel with nuts, bolts and washers etc, systhetic bounded fuse tube complete with line cap suitable for current carrying capacity upto 100Amps all as directed.
repairs/overhauling of air break switch complete by replacing stationary, and moving contacts, fexible copper cord, GI nuts, bolts, etc incl alingment for smooth functioning from ground level all as req uired at site and as directed by E-in -charge.
Supply and fixing cable termination end joint Heat shrinkable out door type suitable for 11 KV cable XLPE aluminium conductor of size 120 sqmm x 3 core and including taking out cable from faulty portion in any situation/position complete all as directed. Make : Denson/Raychem/Cabseal
Supply and fixing cable jointing kit 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sq mm
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm.
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 150 to 185 sqmm x 3.5 core in any situation/position complete all as directed. Make : Denson/Raychem/Cabseal
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 70 to 120 sqmm x 3.5 core in any situation/position complete all as directed. Make : Denson/Raychem/Cabseal
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 25 to 50 sqmm x 3.5 core in any situation/position complete all as directed. Make : Denson/Raychem/Cabseal
Re stringing, streaching and binding with insulator, ACSR conductor ( for single conductorWeasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc all as specified & directed.
Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade (E), of size 3 Core 120 sqmm including taking down old unserviceable cable, complete all as specified.
Supply and fix in replacement disc insulator porcelain viterous, 145 mm high and 255 mm dia ball and socket type, white /brown single disc assembly for tension with tension clamps for conductor working pressure 11000 volts
Supply and fix in replacement Pin type porcelain viterous,white , brown or green insulator including one galvanised mild steel spindle, two galvanised iron wahsers and one galvanised iron nut, 150mm height, 150 mm dia for 11000 volts grade complete all as specified
M&L in replacement of u/s MCCB of 4 pole of capacity 63 to 100 Amps 415 Volts with breking capacity 18 KA complete all as specified and directed by Engr-in-charge. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB of 4 pole 200 Amps adjustable type, 415 Volts, with breking capacity 25 KA complete all as specified and directed by Engr-in-charge. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB of 4 pole 250 Amps adjustable type, 415 Volts, with breking capacity 25 KA complete all as specified and directed by Engr-in-charge. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breking capacity 50 KA complete all as specified and directed by Engr-in-charge. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L for earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.(set of two) NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box in replacement, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars 600Amps capacity for looping & branch connection system .The chamber shall be painted with powder coated paint. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 (a) The bus bar chamber shall be made out of 3.0mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and angle iron padastal frame 600mm high above ground level. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 600mm height (without base frame & canopy), 600mm width and 500mm depth).
Supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box in replacement, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars 400Amps capacity for looping & branch connection system .The chamber shall be painted with powder coated paint. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 (a) The bus bar chamber shall be made out of 3.0mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and angle iron padastal frame 600mm high above ground level. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : For Ser Item No- 36 &37. The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 600mm height (without base frame & canopy), 600mm width and 500mm depth).
M&L for scrubbing out old paint, rust etc from LT Steel tubular pole of any size and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of pole structure and writing Abbreviated feeder name in 2 " size with white paint on black base all as directed at site(work shall be completed in the stipulated period as directed by Engineer -in-charge other wise compensation @ Rs 2000/hour will be charged for extra time for the completion of work ).
M&L for scrubbing out old paint, rust etc from HT two pole structure and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of two pole structure and writing feeder name 2 " size with white paint on black base all as directed at site
All as item No 39 above but four pole structure as directed at site
Note: Amount of sch of credit of Rs.88,792/-will be deducted from total amount of BOQ.
Maruti Abhiyantriki
M/S S T KUNDARIYA
KOYNA ENGINEERS PVT LTD
sapana enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .