| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.8 LAdmitted-Finance NO 262 MOOVENDER NAGAR B B KULAM MADURAI 625 002 | MADURAI | MADURAI | TAMIL NADU | 625002 | ₹75.8 L | L1 | Admitted-Finance |
| 2 | L2₹79.3 LAdmitted-Finance 2 316 B MAGIZHAMPOO STREET GOMATHIPURAM 3RD MAIN ROAD MADURAI 20 | MADURAI | TAMIL NADU | 625020 | ₹79.3 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | JF JAVIDHUSSAIN L2 | P RAMAR PANDI L1 |
|---|---|---|---|---|---|
| 1.01 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls Brick / Stone Masonry in cement mortar walls under 3m high | 5.5 | M³ | 295.9 ₹1,627.45 | 282.9 ₹1,555.95 |
| 2.01 | Dismantling Pressed tiles & weathering course Etc,complete. | 317 | M² | 48 ₹15,216 | 45.9 ₹14,550.30 |
| 3.01 | Picking the damaged cement plastering Area for Wall take away from site etc.complete etc. | 54 | M² | 7.6 ₹410.40 | 7.3 ₹394.20 |
| 4.01 | Earth work excavation for foundation in Hard stiffclay, stiff black cotton, hard red earth, shales murram,gravel,stoney earth and earth mixed with small sizeboulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil,sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc., complete 10 cum. The Rate inclusive of all charges such as Earth work and remove the same away from the site etc, complete as per standard specifications. | 45.5 | M³ | 303.2 ₹13,795.60 | 289.9 ₹13,190.45 |
| 5.01 | Supplying and filling in foundation and basement withfilling Quarry Dust in layers of not more than15cm.thick well rammed watered and compacted etc., complete complying with standard specification. | 3 | M³ | 457.3 ₹1,371.90 | 437.2 ₹1,311.60 |
| 6.01 | Cement concrete 1:4:8 (one cement four sand and eight aggregates) Using 40mm gauge hard broken granite jelly for foundation inc. consolidation and dewatering for foundation wherever necessary etc.complete. | 3 | M³ | 6,786.7 ₹20,360.10 | 6,488.2 ₹19,464.60 |
| 7.01 | Supplying and erecting shuttering with necessary supports for plith beam with all cross brancings etc..,complete(Rcc coloumn footing plinth beam and lintel sides) | 71.5 | M² | 117.9 ₹8,429.85 | 112.7 ₹8,058.05 |
| 8.01 | Supplying and erecting shuttering with necessary supports for plain surface such as RCC boxing side slab, and similar,RCC Slab with all cross bracings etc., complete in all floors of any height (The retrieved materials should be taken back by the contractor). The payment for centering shall be given after the concrete is laid. (Bottom Only) using steel plates10m2. | 24 | M² | 1,240.1 ₹29,762.40 | 1,185.6 ₹28,454.40 |
| 9.01 | Reinforced cement concrete 1:1 1/2 :3 (One cement One and half sand and three aggregate) using 20mm machine broken gauge bard granite jelly for RCC worksthe rate excluding the cost of reinforcement grills,centering and shuttering etc., complete in G.F | 12.5 | M³ | 10,421.8 ₹1.3 L | 9,963.5 ₹1.2 L |
| 10.01 | Supplying fabricating and placing in position of MS grills for reinforcement rate inc. the cost of steel for all works (the rate to include cost of binding wire also). Below 16mm Dia | 1,250 | kg | 99.7 ₹1.2 L | 95.3 ₹1.2 L |
Tender Value
₹75.9 L
EMD Value
₹75,897
Closing Date
13 Jan 2026, 3:00 pmClosed
The Commissioner Madurai Corporation
Aringar Anna Maligai , Thallakulam , Madurai
Proposal for dialysis unit at old pharmacy store operation health (Maintenance work) near existing new UPHC centre Ansari nagar in ward 59
2026_MAWS_639011_1
Z3 / E7 / EST. 386 / 25-26
Open Tender
Civil Works
Madurai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹75,897
3 Feb 2026
3 Jan 2026
13 Jan 2026
3 Jan 2026
13 Jan 2026
3 Jan 2026
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls Brick / Stone Masonry in cement mortar walls under 3m high
Dismantling Pressed tiles & weathering course Etc,complete.
Picking the damaged cement plastering Area for Wall take away from site etc.complete etc.
Earth work excavation for foundation in Hard stiffclay, stiff black cotton, hard red earth, shales murram,gravel,stoney earth and earth mixed with small sizeboulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil,sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc., complete 10 cum. The Rate inclusive of all charges such as Earth work and remove the same away from the site etc, complete as per standard specifications.
Supplying and filling in foundation and basement withfilling Quarry Dust in layers of not more than15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
Cement concrete 1:4:8 (one cement four sand and eight aggregates) Using 40mm gauge hard broken granite jelly for foundation inc. consolidation and dewatering for foundation wherever necessary etc.complete.
Supplying and erecting shuttering with necessary supports for plith beam with all cross brancings etc..,complete(Rcc coloumn footing plinth beam and lintel sides)
Supplying and erecting shuttering with necessary supports for plain surface such as RCC boxing side slab, and similar,RCC Slab with all cross bracings etc., complete in all floors of any height (The retrieved materials should be taken back by the contractor). The payment for centering shall be given after the concrete is laid. (Bottom Only) using steel plates10m2.
Reinforced cement concrete 1:1 1/2 :3 (One cement One and half sand and three aggregate) using 20mm machine broken gauge bard granite jelly for RCC worksthe rate excluding the cost of reinforcement grills,centering and shuttering etc., complete in G.F
Supplying fabricating and placing in position of MS grills for reinforcement rate inc. the cost of steel for all works (the rate to include cost of binding wire also). Below 16mm Dia
Brick work in CM1:3 (one cement & five sand) using ground moulded chamber bricks of size 9"X43/8"X23/4" standard specification including finishing, curing, etc., complete complying with standard specification -100cft
Plastering with cement mortar 1:3, 12mm, thick in all floors including cost and conveyance of all materilals at site and labour charges etc, complete as per standard specifications
Plastering with cement mortar (1:5) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc, complete as per standard specifications (S.I.306)
Plastering with cement mortar 1:3, 20mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc, complete as per standard specifications
Old Terrace Screed Repair with UV Resistant Hybrid PU Waterproof coating above 500 Sq.m - Providing and Applying high strength, hybrid polyurethane Waterproofing coating which is two component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof screed surface applied @ 1.6 L/m2 in 3 coats to achieve 1mm DFT, having tensile strength with 45 gsm glass fibre mesh 10N/mm2 , Elongation ≥ 200%, confirming to ASTM D2370; Abrasion resistance 15mg confirming to ASTM D 4060 and Crack bridging ability up to 3 mm, including surface preparation, ensure surface in SSD condition for first coat and spreading 45 gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification.
Finishing the top of floor with Granolithic Finish with CC 1:2:4 (onecement, twosand & four HBG jelly) using chips of grade 10mm and below for 25mm thickness and rubbed smooth etc,completeasperstandard specification - For 50 mm thick
Paving the top of roof with solar refelective ceramic tiles of approved quality and colour laid in cement mortar bed in 1:3 (one cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the executive engineer before use on works)
Roofing with culvanized corrugated iron sheets of thickness 0.80mm including cost of GI sheets including cost of bolts and nuts and washers Including Cost tress work at angle,channel,pipes work welding and eriction work etc, complete.
Fabriction supply and erection of tobul or post with Truss (100mm,80mm,75mm) The Rate shall be include the cost of tobul or post Truss members, labour charges for manufacturing and erection and Painting etc., complete.as per departmental specification and drawings.
Supplying and fixing in position of Alu.Anodised partition with 62x38x2mm extructed box section at bottom vertical and horizontal members. The vertical member are spaced at 90cm c/c and to horizontal members are spaced at 1.2M, 2.1M and 2.4M height the bottom panels should be covered with 12mm thick PLB exterior grade and the top and middle panels should be fixed at 4mm thick glass thick glass with necessary dismantling holes in RCC Columns, beams masonary wherever necessary with power drill the extent required and made good to the original conditions after fixing as directed by the departmental officers. All the aluminium sections should be anodised to 1.5 microns as per ISI specification 1868/1962.
Supplying and fixing in position of Alu.Anodised natural colour matt finish sliding window in two track in all floors with following sizes. All the three shutters with sliding arrangements, the bottom section should have gutter arrangement so as to drain the water entering and made with extruded aluminium section for outher frame as shown below with necessary accessories such rubber beading. Al.clips, rubber beading, handle and fixing 4mm thick clear sheet glass including all required for fabrication etc., complete. Necessary chipping, dismantling making necessary holes in RCC columns,beams or masonary wherever necessary with power drill to the extent required and made good to the original conditions after fixing etc., complete. the alumi.surface must be anodised with matt finish under electrically controlled condition in accordance with IS specification 1868/1962 for an average anodic film thick of not less than 15 microns.
Supplying and fixing in position of Alu.Anodised natural colour matt finish door half glazed and half glazed and half PLB board using 12mm thick PLB board and 5.5mm thick glazed door using rectangular Alu.Box section of following sizes for frame and shutter with necessary accessories such as rubber beading, Al.clips, best double action floor springs, Aluminium handles on both sides, floor stopper, tower bolt, locks and glass including all materials, labour, power consemption charges required for fabrication if necessary chipping, dismantling making necessary holes in RCC columns,beams or masonary wherever necessary with power drill to the extent required and made good to the original conditions after fixing etc., complete. the alumi.surface must be anodised with matt finish under electrically controlled condition in accordance with IS specification 1868/1962 of anodic filthickeness of not less than 15 microns (Fifteen) for all sections.
Supplying, fabricating, erecting and fixing Calcium Silicate Board False Ceiling upto a ceiling height of 4.5m from floor level - Using Calcium Silicate Board Plain Sheets (10mm thick)
Providing Cup-board Shutter with frame using termite /water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using adhesive along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter.
Supplying P.V.C pipe and C.P.V.C, G.I special etc., complete a) 1" CPVC Pipe (PWD 24-25 Pg-158)
b) 3/4" CPVC Pipe (PWD 24-25 Pg-158)
c) 4" PVC Pipe (TWAD 24-25 Pg-5)
d) 1" CPVC Elbow (PWD 24-25 Pg-161)
e) 1" CPVC Tee (PWD 24-25 Pg-161)
f) 3/4" CPVC Elbow (PWD 24-25 Pg-161)
g) 3/4" CPVC Tee (PWD 24-25 Pg-161)
h) 1/2" SS Tap (PWD 24-25 Pg-89)
i) 4" PVC Tee
j) 4" PVC end cap (TWAD 24-25 Pg-10)
k) 4" PVC Elbow (TWAD 24-25 Pg-10)
l) 4" PVC shoe (TWAD 24-25 Pg-10)
THREE PHASE SUBMERSIBLE PUMPSET SUITABLE FOR 150MM DIA BOREWELL AS PER IS 8034/2002 WITHOUT PANEL BOARD Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % - 50X75 lpm x m
CENTRIFUGAL MONOBLOC PUMPSET AS PER IS 9079/2002 WITHOUT PANEL BOARD THREE PHASE Supply and delivery of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing, hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively - 50x35 - lpmxm
Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents /Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20 Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact-1000 Lit R.O Plant
Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm 'P' os 'S'' trap with Double flapped rigit P.V.C. seat cover with C.P. brasshing with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications, labor inclusive of fixing low level flushing tank. Cost of European water closet, Cost of 'P' or 'S' trap, Cost of seat cover, Cost of C.P. brass hinges, Low Level Flushing Tank White
Supply and fixing of PVC Nahini / Floor Trap with stainless Steel Gratings-100mm x 75mm including all charges etc, complete as per standard specification.
Supplying and fixing in position best quality approved make white glazed earthen ware wash hand basin of size 550 X 400mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape, 32mm diametre C.P. Waste union, 32mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M. wheelvalve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with apair of C.I .brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anti corrosive painting cluding testing for leackage etc., complete complying with standard specifications. Cost of Wash Hand Basin, Cost of 15mm dia G.M. Wheel valve, Cost of 32mm dia C.P. waste union, Cost of 32mm dia P.V.C. wastepipe, Cost of 15mm dia brass nipple, Cost of 12/15 mm dia C.P. piller tape, Cost of 15mm dianylon connection, Cost of Plug and Chain, Cost of C.I. brackets
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., (5000 Lit)
Stainless steel (Grade 304) water tank of 1000 litres capacity with shell thickness 0.60 mm
3 layer PVC Readymade Underground water tank of 1000 litres capacity
Supply and providing 1000 litres capacity Priming Tank made up of PVC.
Priming Tank mounted with the supporting arrangement fabricated using MS angle for the height of 3 metres from the floor level, inlet, outlet, and drain arrangements inside the fire fighting pump room, as directed by the Departmental Officers.
SUPPLY & INSTALLATION OF AIR-CONDITIONER WITH COPPER COIL - 1.5 TR Split Type AC Unit - 5 Star Rated
Supply and installation of 4 KVA capacity Automatic Voltage Stabilizer with time delay relay
1 PHASE UPS (Single Phase In & Single Phase Out) CAPACITY - SYSTEM WITH BATTERY - 2 HOURS BACK-UP - 1 KVA
Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications With Standard Control Panel - 58.5 Kva
Painting old wall surface with two coat of Plastic Emulsion paint of approved quality including cleaning of plaster surface with soap soda and water by manual labour.
Painting old wood work with one coat of Synthetic Enamal paint of approved quality including cleaning the old surface by mannual labour.
Flooring with cuddapah slabs of 40mm thick over a base mortar in CM 1:3 (one cement and three plastering sand ) 20mm thick and pointed with cement mortar 1:3 (one cement and three plastering sand ) using black oxide complying with standard specification
Dadooing the Wall with Cement based hydrualic all pressed Anti-Skid tiles (patterndesign) 20mm thick in cement mortar 1:2-20mm thick & pointed with same colour of cementetc., complete as per standard specification
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Supply and fixing of single box type 4'36W fluorescent fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS Copper leads from terminals to the fitting
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRL Scopper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5AFT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (5 points per coil)
Wiring with 2x4sq.mm. PVC insulated SC unsheathed FRL Scopper conductor cable of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mmx100mmx113mm TW switch box inflush with wall with 3mm thick hylem sheet cover for 15A 3pin flush type non interlocking wall socket with 15A flush type switch with painting of suitable colour with continuous earth wire connection of 4sq.mm copper wire for open PVCpower plug point
Supply and run of 2of1.5sq.mm. PVC insulated SC unsheathed FRLS copper conduct or of 1100V grade insuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection of 1.5sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and run of 2of4sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4sq.mm copper wire and making good of the concealed portion wiith suitable colour
Supply and run of 4 of 6sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable heavy gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 6sq.mm copper wire with painting of suitable colour
Supply and fixing of ceiling fixture 250/300mm complete with gallery etc clear glass Opac/Crystal suitable for 7W/9 W LED bulb with bulb
Supply and fixing of 450mm (18") sweep (light duty) AC exhaust fan complete without provision of hole in the wall
Supply and fixing of 100 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing.
Supply and fixing of 4 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB incomer) with double door (metal door) with 1 no.250A 4P MCCB switch as incoming and 3 nos.63A 3P MCB , 3 nos. 6A to 32A SP MCB as outgoing with suitable cable end box in flush with wall with earth connection only. Higher End
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dianot less than 40mm with copper earth plate of size 125mmx 50mmx 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3feet x 2feet using angle iron of size 1-1/2"x1-1/2"x1/4" rigidly fixed on wall covered with hylem sheet of size 3feet x 2feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos .200A fuse units (500V), 1No. neutral link, copper earth flat of size 1"x1/4" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete
Supply of 5 KVA single phase Servo stabilizer.
Fabricating, Supplying and fixing in position Mosquito net arrangements of Sliding type. The Outer Sliding frame shall be made with Powder coated Aluminium Natural colour matt finish Aluminium Hollow section of size 40mmx38mmx1.55mm. The Horizontal and Vertical Aluminium Hollow section Slidingtrack shutter frame of size 20mmx44mmx1.55mm. The Mid Horizontal Aluminium Hollow section frame provided in the sliding track shutter with a size of 10mmx11mmx1.55mm. The Epoxy coated Stainless Steel 304 grade wire mesh with dia of 0.19mm shall be provided for Net. The Mosquito net arrangement should be fixed to the window with 100% packing with Screws, Silicon packing all around the frames with including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column/wall, masonry walls, Window frames, wherever necessary with drills to the required extent and make good to the original conditions after fixing and also as directed. All the Aluminium sections are to the powder coated with matt finish under electrically controlled conditions in accordance with relevant IS Code etc. complete complying with standard specification and as directed by the departmental officers.
Add GST 18%
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.25 MB
386D.pdf
Tender Documents • 1.97 MB
BOQ_764799.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid